상업용 주방후드의 배기성능 개선방안에 관한 연구 (A Study on the Improvement Strategies for Exhaust Performance in Commercial Kitchen Hoods)

  • 박진철
    • 설비공학논문집
    • /
    • 제15권5호
    • /
    • pp.439-445
    • /
    • 2003
  • The purpose of this study is to suggest the improvement strategies for exhaust performance in composite kitchen hoods. The Exhaust only hood, the 2-way compensating hood and the 3-way compensating hood were selected, and the laboratory experiments were performed to compare the local exhaust efficiency and the indoor temperature distributions according to the variations of the hood type and supply/exhaust air velocity. The results of this study can be summarized as follows. The compensating hood has better performance than exhaust only hood in the aspect of local exhaust efficiency and temperature distribution. The 3-way compensating hood shows the best performance when the supply air velocity is about 2.7 m/s, and the 2-way compensating hood at the supply air velocity of 3.5 w/s. In the same exhaust rate condition, if the exhaust area of the hood is increased and therefore the exhaust velocity is lowered, the supply air velocity is also lowered to get the optimum performance. The optimum exhaust velocity range of the commercial kitchen hood which derived from this study is 0.48 ∼ 0.55 m/s.

실험동물 사육실용 바이오 크린룸(BCR)의 급기 온도 및 풍속 변화 특성에 관한 수치해석적 연구 (A Study on the Variation of Airflow Velocity and Temperature upon the Design of Bio Clean Room(BCR) for Laboratory Animal Facilities by Numerical Simulation)

  • 박동일;정광섭;김영일;김성민
    • 설비공학논문집
    • /
    • 제24권7호
    • /
    • pp.578-584
    • /
    • 2012
  • In this study, the analysis on the distribution of indoor airflow velocity and temperature by using numerical simulation has carried out to make fundamental data for establishing the optimum design of laboratory animal facilities. From the results, it was found that replacement of cage lacks, air supply and exhaust system, supply air temperature, supply air velocity affect to the optimum design of laboratory animal facilities as a important element.

공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구 (Numerical Study on Air Egress Velocity of Ancillary Room Pressurization Systems in Apartment Fires)

  • 김병준;양영;신원규
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.78-86
    • /
    • 2020
  • 본 연구에서는 공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관하여 수치해석을 수행하였다. 수치해석을 통해 댐퍼의 급기량과 방화문에서의 방연풍속의 관계식을 선형적으로 나타내었고 국가화재안전기준인 방연풍속 0.7 m/s를 만족하는 댐퍼의 최소유량을 선정할 수 있었다. 댐퍼의 최소유량을 적용하여 댐퍼의 급기 방향과 설치 높이에 따라 방연속도를 분석하였다. 댐퍼의 급기 방향이 상향인 경우와 댐퍼가 높게 설치되었을 때 댐퍼의 급기 방향이 하향인 경우보다 방화문 상부에서 더 큰 방연풍속을 나타내었고 누출된 연기 농도가 더 낮은 것을 확인할 수 있었다. 따라서 방화문 상부에서 큰 방연풍속을 확보하는 것이 제연에 더 효율적일 것으로 판단된다.

공기유입구 위치에 따른 유입공기의 풍속이 배연시스템 성능효율에 미치는 영향 연구 (The Analysis on the Effect of Supply Air Velocities by Location of Supply Air Damper on the Performance Efficiency of the Smoke Exhaust Systems)

  • 여용주;임채현;김학중;김범규;박용환
    • 한국화재소방학회논문지
    • /
    • 제24권6호
    • /
    • pp.20-27
    • /
    • 2010
  • 배연설비는 연기를 배출한 만큼 공기가 유입되도록 계획된다. 이때 유입공기의 속도가 배연에 어떠한 영향을 미치는지를 FDS를 통하여 분석하였다. 그 결과 화재의 위치로부터 급기구가 가까이 설치된 경우 화재 플럼으로 유입되는 기류속도가 빨라져 상승하는 화재 플럼을 흩트려 버리는 현상이 일어남을 발견하였다. 그로인해 배연성능이 저하되어 연기층의 강하가 더욱 빠르게 촉진되었으며 흐트러진 화재 플럼은 연기층을 교란시켜 가시거리를 더욱 나쁘게 하였다. 따라서 공기유입구의 위치는 화재의 위치로부터 충분히 이격된 위치에 설치하여 화재 플럼으로의 유입공기속도를 낮추도록 하여야 배연효율이 좋아진다는 것을 확인하였다.

사무실 공간의 냉방시 천장 및 바닥 급기 공조 방식에 따른 열환경 평가 실험 (Experimental Analysis of Thermal Comfort of an Office Space for Ceiling and Floor Supply Air Conditioning Systems)

  • 조용;권혁승;김성현;김영일
    • 설비공학논문집
    • /
    • 제12권9호
    • /
    • pp.810-816
    • /
    • 2000
  • Thermal comfort plays an important role in modern office buildings. Four major factors affecting thermal comfort are air temperature, velocity, humidity and radiation temperature. Distribution of these thermal factors in indoor space depends largely on the air flow which is related to the method of supplying and extracting air. In this study, an experimental analysis on indoor thermal comfort is conducted to study the difference between a ceiling supply cooling system and a floor supply one. The two cooling systems are applied to an office space during summer season and the distributions of temperature, velocity, radiation temperature and PMV are measured. Results show that the floor supply cooling system is superior in terms of thermal comfort and energy saving. Studies need to be done, however, to reduce the vertical temperature difference of a floor supply air conditioning system.

  • PDF

바닥취출 공조공간에서 급기온도 및 급기풍속이 환기효율에 미치는 영향 (Effect of supply air temperature and airflow rate on ventilation effectiveness in an underfloor air conditioning space)

  • 정광섭;한화택;홍승재
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.640-648
    • /
    • 1998
  • A numerical study has been conducted to investigate the effect of inflow supply air temperature and velocity on ventilation effectiveness in an underfloor air conditioning space. A low Reynolds number k-$\varepsilon$ model is implemented to calculate steady state turbulent velocity distributions. A step-down injection method is used to calculate local and room mean ages from transient concentrations based on the concept of the age of air. Results show that there is a significant effect of Archimedes number on ventilation effectiveness especially for cooling conditions. Reynolds number shows relatively minor effect on velocity distribution and ventilation effectiveness especially for isothermal and heating conditions. It can be concluded that underfloor air conditioning system provides good ventilation characteristics for cooling conditions because of temperature stratification in the space.

  • PDF

돔경기장의 급배기방식에 따른 기류분포 및 실내온도 특성 (The Characteristics of Indoor Temperature and Airflow Distribution for Air Supply and Return System in Dome Stadium)

  • 채문병;양정훈;석호태
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.434-439
    • /
    • 2008
  • Dome stadiums give thermal unpleasant feeling to occupants because of the radiant heat and the indoor and outdoor haet exchange from roogs or lightweight building envelopes of sidewalls. This study analyzed the indoor temperature and velocity distribution according to various air supply and return sustems in dome stadiums in summer.

  • PDF

발사체 탑재물 페어링 내부 공기 공급을 위한 탑재 시스템 유동 해석 (FLOW ANALYSIS OF THE ON-BOARD SYSTEM FOR THE AIR SUPPLY TO THE PAYLOAD FAIRING OF A LAUNCH VEHICLE)

  • 옥호남;김영훈;김인선
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.269-273
    • /
    • 2005
  • The on-board system for the air supply to the payload fairing(PLF) of a launch vehicle using both high and low pressure air was designed. The design concept was obtained from the CFD analysis of a Russian interstage air supply system, and a collector was adopted to expand the high pressure air. To verify that the on-board system would work as designed, a simplified axisymmetric computational model was made and a CFD analysis was also performed. It was found that the flow ejected from the hole of the collector expands to the Mach number of 4 and is soon retarded due to the action of viscosity. It was also found that a small gap between the low pressure duct and equipment bay wall can cause large velocity in PLF over the velocity requirement and no gap should be allowed in the design.

  • PDF

핀 부착 열교환기에서 습증기(mist)발생 메커니즘의 파악을 위한 실험적 고찰 (An Experimental Study on Understanding of Production Mechanism of a Mist from Fin Adhesion heat Exchanger)

  • 최권삼
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2000년도 춘계학술대회 논문집(Proceeding of the KOSME 2000 Spring Annual Meeting)
    • /
    • pp.146-152
    • /
    • 2000
  • As an improvement in the standard of living and economic growth the demand for air conditioning equipment is increasing rapidly. Nowadays air conditioning equipments are being used for industry large building house and car. Thess equipments was concentrated on improving heat efficiency of economic aspects while they design heat exchanger for cooling and heating,. These air conditioning equipments using heat exchanger cause a discomfort to user due to generating mist at the beginning of operating. Therefore the user demand air of high class and quality. In this experimental study to acquire elementary data for development of heat exchanger which be able to supply air of high quality that is to say possess a restraint effect of mist generation. We estimate an effect on cooling plate kind supply air velocity supply air temperature cooled plate temperature and supply air relative humidity which have an influence on outlet air condition of heat exchanger.

  • PDF

모델실험 및 수치해석을 통한 페리미터존 에어배리어 공조방식웨 열성능 평가 (Evaluation of Thermal Performance for Air-Barrier Air-conditioning System in Perimeter Zone by Scale Model Experiment and Simulation)

  • 함흥돈;박병윤;손장열
    • 설비공학논문집
    • /
    • 제17권10호
    • /
    • pp.947-955
    • /
    • 2005
  • For the purpose of evaluating the thermal performance for air-barrier air conditioning system in perimeter zone, two air-conditioning systems, conventional perimeter air-conditioning system and air-barrier system, are evaluated and compared by scale model experiment and simulation during cooling season. As a result, measurement shows that supply air velocity of 1 m/s in the upstream direction at perimeter is more effective. Air-barrier system could reduce the cooling energy by $10\sim20\%$ compared with conventional system. Numerical simulation was carried out considering solar effect for reliable result. This method has improved the accuracy of numerical simulation for the space affected by the solar radiation. Both measurement and simulation results show that supply air velocity of 1 m/s at perimeter is the most effective.