• Title/Summary/Keyword: Supply Side

Search Result 703, Processing Time 0.025 seconds

A transient CFD simulation of ventilation system operation for smoke control in a subway station equipped with a Platform Screen Door(PSD) when a train under fire is approaching the station (화재열차의 역사 접근 시 PSD가 설치된 역사 제연을 위한 환기장치 운전 비정상상태 해석)

  • Shin, Kyu-Ho;Hur, Nahm-Keon;Won, Chan-Shik
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.269-272
    • /
    • 2006
  • The heat and smoke which generated by subway under fire is one of the most harmful factor in air tighten underground station. To prevent this, Trackway Exhaust System(TES) can be used. The heat released from the train running in the tunnel raises the temperature at the platform and the trackway, and thus proper ventilation system is required for comfortable underground environment. When the fire is occurred, TES is operated as smoke exhaust mode from normal ventilation mode. In the present study, the subway station which is one of the line number 9 in Seoul subway is modeled, and fired situation is simulated with several ventilation mode of ventilation system in trackway. For this simulation whole station is modeled. Non steady state 3D simulation which considered train under fire is entering to the station is performed. Temperature and smoke distribution in platform and trackway are compared. To represent heat by fire, heat flux was given to the fired carriage, also to describe smoke by fire, concentration of CO is represented. As the result of present study, temperature and smoke distribution is different as the method of ventilation in trackway and platform is changed. In over side of trackway, the fan must be operated as exhaust mode for efficient elimination of heat and smoke, and supply mode of fan operation in under side shows better distribution of heat and smoke. The ventilation system which is changed from ventilation mode to exhaust mode can be applied to control heat and smoke under fire.

  • PDF

Uranium-Series Growth Rates of Two Manganese Nodules from the KODOS-89 site, Clarion-Clipperton Fracture Zones of the Central Equatorial Pacific (우라늄 계열 기법으로 측정된 클라리온-클리퍼톤 균열대 KODOS-89 지역 망간단괴 2개의 성장속도)

  • MOON, DEOK SOO;KIM, KEE HYUN;KANG, JUNG KEUK
    • 한국해양학회지
    • /
    • v.29 no.3
    • /
    • pp.248-257
    • /
    • 1994
  • Growth rates of two manganese nodules collected in the Korea Deep Ocean Study (KODOS-89) site in the Clarion-Clipperton Fracture Zones in the central Equatorial Pacific have been estimated by employing uranium-series disequilibrium techniques to investigate the geochemical processes leading to the formation of deep-sea nodules. the growth rates estimated from the profiles of excess /SUP 230/Th activities and ratios of excess /SUP 230/Th to /SUP 232/Th to /SUP 232/Th are in the order of a few millimeters per million years. Growth rates at bottom-side of nodules are 2-3 times faster than those at top-sides. Diagenetic supply of manganese could explain the faster growth at the bottom-side of nodules.

  • PDF

Experimental Study on Liquid Desiccant Distribution Characteristics at a Dehumidifier with Extended Surface (확장표면을 적용한 액체식 제습기에서 제습액 분배 특성에 관한 실험적 연구)

  • Lee, Min-Su;Chang, Young-Soo;Lee, Dae-Young
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.645-649
    • /
    • 2009
  • Liquid desiccant cooling technology can supply cooling by using waste heat and solar heat which are hard to use effectively. For compact and efficient design of a dehumidifier, it is important to sustain sufficient heat and mass transfer surface area for water vapor diffusion from air to liquid desiccant on heat exchanger. In this study, the plate type heat exchanger is adopted which has extended surface, and hydrophilic coating and porous layer coating are adopted to enhance surface wettedness. PP(polypropylene) plate is coated by porous layer and PET(polyethylene terephthalate) non-woven fabric is coated by hydrophilic polymer. These coated surfaces have porous structure, so that falling liquid film spreads widely on the coated surface foaming thin liquid film by capillary force. The temperature of liquid desiccant increases during dehumidification process by latent heat absorption, which leads to loss of dehumidification capacity. Liquid desiccant is cooled by cooling water flowing in plate heat exchanger. On the plate side, the liquid desiccant can be cooled by internal cooling. However the liquid desiccant on extended surface should be moved and cooled at heat exchanger surface. Optimal mixing and distribution of liquid desiccant between extended surface and plate heat exchanger surface is essential design parameter. The experiment has been conducted to verify effective surface treatment and distribution characteristics by measuring wall side flow rate and visualization test. It is observed that hydrophilic and porous layer coating have excellent wettedness, and the distribution can be regulated by adopting holes on extended surface.

  • PDF

A Study on the Evaluation of Design of Road Horizontal Alignments Based on the Operating Speed (주행속도 기반 도로 평면선형 설계 안전성 평가연구)

  • Kim, Yong-Seok;Cho, Won-Bum
    • Journal of Korean Society of Transportation
    • /
    • v.22 no.7 s.78
    • /
    • pp.25-32
    • /
    • 2004
  • It is implicated in the current road design manual that design speed is well representing the operating speed of drivers. On the contrary, the disparity between the design speed and operating speed means that current road design cannot guarantee the safety and comfort of driving. In this context, operating speed was observed at the two lane rural roadways to find out the relation of operating speed and design speed. In addition to this, the friction factor from supply and demand which was derived from the operating speed was compared in terms of the dynamics in driving safety factor. It was concluded that the actual speed was consistently exceeding the design speed at the horizontal curves having the radius less than or equal to 200 m. Similarly, the demanded side friction was also consistently exceeding the supplied side friction at the horizontal curves having the radius less than or equal to 200 m and the amount of difference was also inversely proportional to the radius of the horizontal curves.

Dietary Quality and Foodservice Menu Pattern of American International Schools in Seoul and Gyeonggi Area (서울.경기지역 외국인학교 급식 메뉴패턴과 식사의 질 평가)

  • Kim, Ok-Sun;Lee, Young-Eun
    • Korean journal of food and cookery science
    • /
    • v.31 no.2
    • /
    • pp.214-224
    • /
    • 2015
  • This study was conducted to identify the combination of foods and foodservice menu patterns, food supply rankings and dietary quality through the a collection of school menus from the fifth week of October 2009, up to the fourth week of November 2009, in three American international schools in Korea. The results of analysis were as follows. For the basic pattern of American international school foodservice menu, dietary patterns comprised of rice, soup, five side dishes, Kimchi and snacks were 23.19%, while menu pattern comprised of rice, soup, four side dishes, Kimchi and snacks were 18.84%. The two dietary patterns accounted for 42.03%. For the foodservice frequency and food rankings from No. 1 to No. 5, vegetables and seasoned vegetables were the highest, followed by cooked rice, Kimchi, soup, and stir-fried foods. For nutrients, the intake ratio of carbohydrates, protein and fat for the calories provided at the three schools was 57:18:24, 53:18:29, and 55:18:27. Compared with 55~70:7~20:15~25 according to by Korean nutrition standards, carbohydrates and protein were adequate, but fat was high. For the recommended nutrient intake (RNI), the provided nutrient ratio was higher than the RI of nutrition standards in schools. For the average nutrient adequacy ratio (NAR), all three schools were above 1. School C had an above-average ratio for vitamin B-complex and vitamin A. Phosphorus showed a significant difference in the nutrient density. For DDS, school C provided all five main food groups every day.

Surface Safety Characteristics of Polypropylene Surface Treatment by Variation of Rolling Speed and The Electric Power of Corona Discharge (코로나방전 표면 처리시 이동속도 및 공급전력 변화에 따른 폴리프로필렌 표면 안전성 특성)

  • Lee, Su Hwan;Lee, Dong Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.41-46
    • /
    • 2018
  • Experiments were carried out the phenomenal observation on effect of corona treated hotmelt laminating film in process of manufacture by 2 kinds of rolling speed and electric power variatons. Surface treatment by corona which is exposure of film surface to electron of ion bombardment, rather than mere exposure to active species, like atomic oxygen or ozone, can enhance adhesion by removing contaminant, electret, roughening surface, and introducing reactive chemical group. Reactive neutrals, ions, electron and photons generated during the corona treatment interact simultaneously with polymers to alter surface chemical composition, wettability, and thus film adhesion. However, it is highly recommended that extensive chains scission is avoided because it can lead to side-effect by forming sticky matter, resulting in dropouts. This paper reviews principles of surface preparation of polypropylene substrate by corona discharging. In addition, the experimental section provides a description of parameter optimization on corona discharging treatment and its side-effect. Experimental results are discussed in terms of surface wetting as determined by contact angle and SEM measurements. When the rolling speed of the film decreased from 1.666 [m / sec] to 0.083 [m / sec], contact angle decreased from $80[^{\circ}]$ to $64[^{\circ}]$, and the wettability was greatly improved. As the supply power increased from 0.4 [kVA] to 2 [kVA] at the corona discharge surface treatment, the contact angle decreased from $77[^{\circ}]$ to $65[^{\circ}]$, and the wettability was greatly improved.

The Model Development of Satisfaction Measurement Index of Education Service and the Improvement Plan of IPA (교육서비스의 만족도지수 모형개발 및 IPA를 통한 개선방안)

  • Lee, Sang-Jun;Yoon, Kwan-Ho;Kim, Seong-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.11
    • /
    • pp.510-521
    • /
    • 2013
  • The awareness of education service is undergoing a transition from demand side to supply side. This study 1) develops an evaluation model of education service composed of three core factors(curriculum content, professor activities, job search activity) and additional factors(public welfare, education environment, campus life), 2) verifies a model using the structural equation model, 3) calculates the satisfaction measurement index of education service, and 4) proposes the results of IPA for evaluating the satisfaction measurement of education service. The results show significant notions that core factors(curriculum content, professor activities, job search activities) and additional factors(public welfare, education environment, campus life) determine students satisfaction, and that student satisfaction effects the recommend purpose significantly. Especially, student satisfaction influenced curriculum content, job search activity, campus life, public welfare, professor activities, education environment in order. This study provides improved strategic implications based on the calculated results of component satisfaction measurement index, and the results of IPA.

Effects of Network Externality on Perceived Value and Adoption of High-tech Products : Focusing on Convergence Products (네트워크 외부성이 첨단기술제품에 대한 가치와 채택의도에 미치는 영향: 컨버전스제품을 중심으로)

  • Park, Kyung Ja
    • The Journal of Information Systems
    • /
    • v.24 no.4
    • /
    • pp.21-42
    • /
    • 2015
  • Purpose The high-technology market shows characteristics of a highly interdependent network market in both supply-side and demand-side, compared to other markets. Particularly, for convergence products, connectivity with related elements, as well as characteristics of innovation itself, is relatively important to the extent that they combine functions provided by several devices into a single device. Therefore, this study aims to identify whether network externality exists in value and adoption of a convergence product and discover a source of network externality, if any. Design/methodology/approach: Through a preceding research analysis and a literature review, 'social influence' and 'network size' have been drawn as direct network elements. On the other hand, general (comprehensive) concept compatibilities including 'intra-technology compatibility', 'inter-technology compatibility' and 'complementary-technology compatibility' are regarded as indirect network elements. Findings: Major findings are as followed;- First, it is shown that the factors influencing on perceived value of a convergence products are 'social influence' and 'network size' as the direct network elements and 'complementary-compatibility' among indirect network elements. Second, it is also found that 'intra-technology compatibility', 'inter-technology compatibility', 'complementary-compatibility' and 'perceived value' have significant effects on adoption of a convergence product. Particularly, it is known that 'complementary-compatibility' is an important source of network externality as it plays a decisive role in value judgment and has significant effects on perceived value. It is worthwhile to notice that this study comprehensively explains effects of network on high-tech products by structuring comparability as a multi-dimensional concept, as well as direct network elements.

Abnormal High-Temperature Behavior Troubleshooting of Process Compressor Tilting Pad Journal Bearing (프로세스 압축기 틸팅패드 저널베어링의 비정상 고온거동 트러블슈팅)

  • Lee, An Sung;Lee, Woonsil;Choi, Dong-Hoon
    • Tribology and Lubricants
    • /
    • v.33 no.2
    • /
    • pp.37-44
    • /
    • 2017
  • A DE-side LBP tilting pad journal bearing of a 1-stage overhung heat-pump compressor in a propylene process exhibited abnormal high-temperature behavior. Its temperature had been relatively high at $78^{\circ}C$ from the beginning of operation. In 2014, after three years of operation, it increased suddenly and reached $103^{\circ}C$. Installing a varnish removal equipment and others managed to stabilize the temperature at $95^{\circ}C$. We undertook a troubleshooting approach for reviewing the comprehensive status and integrity of the temperature design of the bearing. We performed lubrication and heat-balance analysis, based on the design engineering data and documents supplied by the OEM. For the base design data of DE-side TPJB, evaluating the effects of key design variables on bearing metal temperature showed that firstly, increasing the bearing clearance and supply oil flow-rate, and next, changing the oil type, and finally, increasing the machined pad clearance and offset, are more effective in reducing the bearing metal temperature. Furthermore, a clarification meeting with the OEM revealed that an incorrect decision had been made to decrease the bearing clearance to eliminate the SSV harshness issue, while not maintaining a sufficient oil flow-rate. We conducted a detailed retrofit design analysis, wherein we increased the oil flow-rate and bearing clearance by decreasing the preload. We predicted that the bearing temperature would decrease to $63^{\circ}C$ from $75.7^{\circ}C$ even at the rerate condition. Finally, after installing and operating a retrofit replacement bearing in 2015, the bearing temperature stabilized at a low temperature of $65^{\circ}C$. Currently (January. 2017), two year later, the bearing metal temperature remains at $65^{\circ}C$. Therefore, we can conclude that the abnormal high-temperature behavior of the bearing has been resolved completely.

A Study on the Construction of IoT based System for District Heating Customer-side Energy Efficiency Management (지역난방 수용가측 효율관리를 위한 IoT 기반 시스템 구축에 관한 연구)

  • Yun, Jungmee;Lee, Sanghak;Ahn, Changkoo;Eom, Jaesik
    • Journal of Energy Engineering
    • /
    • v.26 no.3
    • /
    • pp.113-122
    • /
    • 2017
  • The district heating system, which is the main axis of Korea's collective energy business, contributes to the national benefit and safety with the economical heat energy supply system.However, due to the uncertainty of management subjects and the shortage of professional technical personnel, there are many problems such as deterioration of thermal efficiency and unfairness of the price of the apartment houses. In this paper, we propose the monitoring points necessary for the efficiency and fault management of the district heating customer-side. And we propose a standard reference model to standardize it. We propose a technical methodology to improve the service quality and energy efficiency of the district heating facilities by applying IoT sensor technology, real-time monitoring and integrated management system.