• Title/Summary/Keyword: Supply Side

Search Result 703, Processing Time 0.023 seconds

A Gate Drive IC for Power Modules with Shoot-through Immunity (상단락 방지용 모듈을 구동하기 위한 게이트 구동 IC)

  • Seo, Dae-Won;Kim, Jun-Sik;Park, Shi-Hong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.7
    • /
    • pp.580-583
    • /
    • 2009
  • This paper introduces a gate drive IC for power modules with shoot-through immunity. A new approach uses a bootstrap diode as a high-side voltage bias and a level shift function at the same time. Therefore, the gate drive circuit becomes a simple and low-cost without conventional level shift functions such as HVIC(High-Voltage IC), optocoupler and transformer. The proposed gate drive IC is designed and fabricated using the Dongbu-Hitek's 0.35um BD350BA process. It has been tested and verified with IGBT modules.

The study on noise reduction using the modulation of switching frequency (스위칭 주파수 변조를 통한 잡음 감소에 관한 연구)

  • Park, Seok-Ha;Kim, Jong-Bum;Ma, Keon-Soo;Lee, Jun-Koo;Kim, Jin-Sung;Kim, Yang-Mo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2106-2107
    • /
    • 1998
  • This paper analyzes the sources of EMI noise, and Presents the noise reduction method using the modulation of switching frequency. Modulating the switching frequency makes the noise of side bands by shattering emission spectrum, and then can reduce the size of EMI filter at input line of power supply.

  • PDF

A Study on Digital Fault Locator for Transmission Line (송전선로용 디지털 고장점 표정장치에 관한 연구)

  • Lee, Kyung-Min;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.291-296
    • /
    • 2015
  • Transmission line is exposed to a large area, and then faults are likely to occur than the other component of power system. When a fault occurs on a transmission line, fault locator helps fast recovery of power supply on power system. This paper deals with the design of a digital fault locator for improvement accuracy of the fault distance estimation and a fault occurrence position for transmission line. The algorithm of a fault locator uses a DC offset removal filter and DFT filter. The algorithm utilizes a fault data of GPS time synchronized. The computed fault information is transmitted to the other side substation through communication. The digital fault locator includes MPU module, ADPU module, SIU module, and a power module. The MMI firmware and software of the fault locator was implemented.

Optimal Microgrid Operation Considering Combined Heat and Power Generation with Variable Heat and Electric Ratio (가변 열전비를 갖는 열병합 발전설비가 포함된 마이크로그리드의 최적 운용)

  • Lee, Ji-Hye;Park, Je-Se
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1548-1553
    • /
    • 2012
  • The important requirement for microgrid operation is to meet the balance between supply and demand. To meet, Combined Heat and Power (CHP) generation should be considered in microgrid scheduling. CHP generation is economical on the side of a consumer because it products heat and power. Therefore, it is high efficient. This paper presents a mathematical model for optimal microgrid operation including CHP generation using the optimal ratio of heat and power due to demand. The objective function and constraints are modeled by linear program (LP). Through the case study, the validation of the proposed model is shown.

Threshold Voltage Dependence on Bias for FinFET using Analytical Potential Model

  • Jung, Hak-Kee
    • Journal of information and communication convergence engineering
    • /
    • v.8 no.1
    • /
    • pp.107-111
    • /
    • 2010
  • This paper has presented the dependence of the threshold voltage on back gate bias and drain voltage for FinFET. The FinFET has three gates such as the front gate, side and back gate. Threshold voltage is defined as the front gate bias when drain current is 1 micro ampere as the onset of the turn-on condition. In this paper threshold voltage is investigated into the analytical potential model derived from three dimensional Poisson's equation with the variation of the back gate bias and drain voltage. The threshold voltage of a transistor is one of the key parameters in the design of CMOS circuits. The threshold voltage, which described the degree of short channel effects, has been extensively investigated. As known from the down scaling rules, the threshold voltage has been presented in the case that drain voltage is the 1.0V above, which is set as the maximum supply voltage, and the drain induced barrier lowing(DIBL), drain bias dependent threshold voltage, is obtained using this model.

DP Formulation of Microgrid Operation with Heat and Electricity Constraints

  • Nguyen, Minh Y;Choi, Nack-Hyun;Yoon, Yong-Tae
    • Journal of Power Electronics
    • /
    • v.9 no.6
    • /
    • pp.919-928
    • /
    • 2009
  • Microgrids (MGs) are typically comprised of distributed generators (DGs) including renewable energy sources (RESs), storage devices and controllable loads, which can operate in either interconnected or isolated mode from the main distribution grid. This paper introduces a novel dynamic programming (DP) approach to MG optimization which takes into consideration the coordination of energy supply in terms of heat and electricity. The DP method has been applied successfully to several cases in power system operations. In this paper, a special emphasis is placed on the uncontrollability of RESs, the constraints of DGs, and the application of demand response (DR) programs such as directed load control (DLC), interruptible/curtaillable (I/C) service, and/or demand-side bidding (DSB) in the deregulated market. Finally, in order to illustrate the optimization results, this approach is applied to a couple of examples of MGs in a certain configuration. The results also show the maximum profit that can be achieved.

An e-Business Strategy for Small and Medium-sized Enterprises and Case Studies (중소기업 정보화 추진 전략과 적용 사례)

  • 김은홍;서정우;안성만;장성봉
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 2003.11a
    • /
    • pp.219-222
    • /
    • 2003
  • This paper is to propose e-business strategies for individual SME's(small and medium-sized enterprises). e-business maturity model is used to assess e-business maturity level of a target SME, and then corresponding e-business strategy is proposed based on the current maturity level. We studied two SME's to show how it works. Most SME's are small and do not have enough resources to invest on information systems. As it turns out, e-business strategies of SME should heavily depend on its relationship with customers and suppliers. One of the studied SME's is found to be in higher maturity level, because its manufacturing system is tightly related to its customer. One of major implications of this study is that e-business level of SME's should be upgraded considering how it is doing business with its customers and suppliers.

  • PDF

A Study on the Variation of Power Factor by Connection of the Induction Generator to the Distribution Line (배전선로에 유도발전기 연결시 역률 변동에 관한 연구)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.159-163
    • /
    • 2015
  • Recently squirrel cage induction generator has been steadily applied to many small hydro power plants. Induction generator needs a reactive power for magnetization. The reactive power of induction generator is being supplied from the supply side mostly. The use of induction generators in the power distribution grid can affect the power factor. The power factor of induction generator is fixed already during production. The power factor in the distribution system is due to the increase or decrease of the load rather than due to the induction generator. In this study, we analyzed that how the increase or decrease of D/L load impacts at the change of power factor and power flow.

A Study Regarding the Recognition and Use Actual Condition about the Western Style Furniture (입식가구에 관한 사용자 인식 및 이용실태에 관한 연구)

  • Yim, Jong-Hun;Kim, Kyung-Sook
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2006.11a
    • /
    • pp.86-90
    • /
    • 2006
  • Through this study, I conducted surveys on apartments with western style furniture to investigate perception on the western style furniture and its use. For the subject of survey, I selected three apartment complexes at Suji-gu, Yongin city which has been recently developed as a new town. Out of total 150 copies of survey sheets 142 fully answered copies were adopted as a final analysis data. Considering supply rate and application, sofa and chair of dining table were chosen to refer as western style furniture. As a result, most of the respondents had inconvenience in using western style furniture. Further study on side effects of adopting western style furniture should be followed.

  • PDF

Surgical Treatment of Pulmonary Atresia with VSD - A Report of 2 Cases - (심실중격결손증을 동반한 폐동맥 폐쇄증 [Pulmonary Atresia] 의 외과적 치료-2예 보고-)

  • 강면식
    • Journal of Chest Surgery
    • /
    • v.20 no.4
    • /
    • pp.780-785
    • /
    • 1987
  • Pulmonary atresia with VSD is uncommon congenital anomaly with high mortality in neonatal period. Recently we experienced surgical correction of 2 cases of pulmonary atresia with VSD. The first case was 7-year old female patient and diagnosed as pulmonary atresia with VSD combined PDA. So, total correction was undertaken which consisted of PDA ligation, patch repair of VSD, transannular enlargement of RVOT with woven Dacron vascular graft, and closure of PFO. Postoperative systemic Rt. ventricular and radial artery pressure ratio was 0.44 and her postoperative course was uneventful. The second case was 6-year old male patient diagnosed as pulmonary atresia with VSD and large systemic-pulmonary collateral arteries. There were two large systemic-pulmonary collaterals, one was simply controlled by ligation, but the other was considered to supply Rt. upper lung. So end to side anastomosis was performed to the RVOT patch. Postoperative systolic Rt. ventricular and radial artery pressure ratio was 0.54. During the follow up period he showed clinical picture of Rt. heart failure, which is relatively well controlled with anticongestive therapy.

  • PDF