• Title/Summary/Keyword: Supervisory Control and Data Acquisition System

Search Result 94, Processing Time 0.051 seconds

Implementation of Intelligent Container System and Information Processing Using Fuzzy Logic (지능형 컨테이너 시스템의 구현과 퍼지 논리를 이용한 정보처리)

  • Son, Sang-Hyuk;Kang, Geun-Taek;Lee, Won-Chang
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.3
    • /
    • pp.398-403
    • /
    • 2009
  • The recent trend of logistics demands for improved monitoring system of the inside of containers including current temperature and other environmental conditions. This paper presents an information processing technique with fuzzy logic that recognizes the current situations inside the target container and can be implemented on intelligent container systems. The ZigBee modules are used to collect information such as temperature, humidity, and shock inside the container in ubiquitous environment. The information processing system using fuzzy logic and the InTouch, one of SCADA(Supervisory Control and Data Acquisition) systems, is implemented to monitor the inside of the container and predict the emergency state.

A Design of MIB for Power System Using XML Web Service (XML 웹서비스를 이용한 전력시스템 MIB 설계)

  • Jung, Nam-Joon;Yang, Il-Gwon;Song, Jae-Ju;Ko, Jong-Min;Oho, Do-Eun
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2008.06b
    • /
    • pp.473-478
    • /
    • 2008
  • 산업계에서의 제어시스템(Control System)은 크게 SCADA(Supervisory Control And Data Acquisition) 시스템, 분산 제어시스템(Distributed Control System, DCS), PLC 시스템 (Programmable Logic Controller System)으로 분류할 수 있다. 특히 전력분야의 SCADA 시스템은 목적상 실시간의 대규모 측정 정보 취득을 목적으로 운영되며, 실시간 및 이력 데이터베이스, 원격 데이터 취득, 다양한 데이터 처리, Supervisory Control 등 복잡한 기능과 다양한 전력시스템과의 정보교환이 요구된다. 다양한 전력시스템과의 정보 교환을 위한 표준화 요구에 부응하여, 향후 전력시스템은 표준화되고 공개된 정보모델을 활용한 통합시스템 개발이 요구된다. 본 논문에서는 전력 공통정보모델(CIM)과 애플리케이션 통합 정보기술을 이용한 전력시스템의 메시지 통합버스 설계에 대하여 기술하고자 한다.

  • PDF

A study on vulnerabilities of serial based DNP in power control fields (전력 제어시스템의 시리얼 기반 DNP통신 취약점에 관한 연구)

  • Jang, Ji Woong;Kim, Huy Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.23 no.6
    • /
    • pp.1143-1156
    • /
    • 2013
  • Power control system like SCADA(Supervisory Control And Data Acquisition) is gathering information using RS232C and low-speed analog communication network. In general, these methods are known as secure because of the secure characteristics from the analog based communication network and serial communication. In this study, first we build DNP communication environment using commercial power control simulator and find some vulnerabilities by testing from the viewpoint of confidentiality, integrity and availability. Consequently, we see the necessity of a valid method for authentication and data encryption when gathering information, even though that is known as secure so far. Discussion of needs of DNP authentication and data encryption is started about several years ago, but there is still nowhere applied that on real environment because the current methods can not fully meet the security requirements of the real environment. This paper suggests a solution to the vulnerabilities, and propose some considerations for enhancing power control system's security level by applying DNP authentication and data encryption.

The Development of Interoperability Tester for the IEC 61850 based on TTCN-3 (TTCN-3 적합성 시험 언어를 이용한 IEC61850 상호 연동성 시험기 개발)

  • Song, Byung-Kwen;Lee, Suk-Hee
    • Journal of IKEEE
    • /
    • v.14 no.3
    • /
    • pp.210-218
    • /
    • 2010
  • TTCN-3(Testing & Test Control Notation Version 3) is the international standard testing language defined by ETSI in 2001. TTCN-3 is generally used for protocol conformance test, but it is also possible to be applied to the platform and API tests based on CORBA. Moreover, it can be also applied to the various testings such as interworking testing, repetition testing, platform testing, etc. IEC 61850 is the protocol proposed for SAS(Substation Automation System) of SCADA(Supervisory Control And Data Acquisition) system. In this paper, a IEC 61850 interoperability Tester based TTCN-3 is developed under the Window environment. IEC 61850 Server Simulator of Linux operating system is used as SUT(System Under Test). Conformance testing items in this paper are the Positive test case_Srv5 of "Server, Logical device, Logical node, and data model" in the testing group of "IEC 61850 - Part10" document.

The study of linkage between systems to make the database of distribution automation system (대규모 배전자동화 시스템의 데이터베이스 구축을 위한 시스템 연계 연구)

  • Ha, B.N.;Kang, M.H.;Cho, N.H.;Jeong, C.S.;Kim, J.S.;Lee, H.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.419-421
    • /
    • 2001
  • The large distribution automation system for metropolitan city was developed in KEPCO just recently. This system has many functions for remote control and data acquisition, and it will be linked the other computer aided system such as NDIS(new distribution automation system) and SCADA(supervisory control and data acquisition) to construct the database of DAS(distribution automation system).

  • PDF

Symmetric Encryption Application to Cyber Security of KEPCO SCADA Network (SCADA 시스템 정보보안들 위한 대칭키 암호 적용)

  • Kang, Dong-Joo;Kim, Hak-Man
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.291-293
    • /
    • 2007
  • SCADA (Supervisory Control and Data Acquisition) SCADA refers to the combination of telemetry and data acquisition [1]. SCADA system has been used for remote measurement and control on the critical infrastructures as well as modem industrial facilities. Electric Power system is a representative system using SCADA network for its communication. Integration between many networks and increasing threatens of terrorism have made the potential risk by cyber attacks real and bigger in power system. Recently, many researching efforts have been made on SCADA network for improving its security. In general aspect, there are already several ways to secure the system like encryption, firewall, authentication, etc. In this paper, we focus on symmetric encryption method and propose the proper key distribution method to reflect the unique characteristics of SCADA network communication.

  • PDF

Security Technology for SCADA Communication Data (SCADA 통신 데이터 보호 기술)

  • Kim, Hak-Man
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.10a
    • /
    • pp.217-219
    • /
    • 2008
  • SCADA(Supervisory Control and Data Acquisition) is popular control and monitor areas not only in critical infrastructures such as electric power, gas, oil but also industrial applications. Increasement of cyber attack technique and frequency threats secure operation of SCADA systems. Recently many researches have been studied for protecting SCADA system against cyber attacks. This paper introduces overall security technologies in SCADA systems.

  • PDF

A study on the optimal stratege of SCADA (Supervisory Control And Data Acquisition) System in electric railway power system (전기철도 전력 원방 감시제어 시스템 최적 구성방안 연구)

  • Byun Jae-Young;Chang Sang-Hoon;Kim wang-Gon
    • Proceedings of the KSR Conference
    • /
    • 2005.11a
    • /
    • pp.990-996
    • /
    • 2005
  • This paper is countermeasure against the problem point it will be able to occur with infiltration of the hardware and software. And, we proposed the optimum integrated of system construction plan for the SCADA system function set and a system design.

  • PDF

Analysis for Frame Error Rate of a Data Transmission Protocol between CTC and SCADA (CTC와 SCADA간 정보전송 프로토콜에 대한 프레임 에러율 분석)

  • 강문호;이재호;황종규;박영수
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.4
    • /
    • pp.296-301
    • /
    • 2004
  • This paper addresses an analysis for a railway data transmission protocol-Ethernet based data transmission between the CTC(Centralized Traffic Control System) and the SCADA(Supervisory Control and Data Acquisition) system. Fame error rates of the data transmissions are calculated and compared for the two cases that the CTC/SCADA has an extra data transmission error control(CRCI6) besides the inherent error control of the Ethernet(CRC32), and that the CTC/SCADA has no extra data transmission error control. With simulation results it has been verified that the extra data transmission error control(CRC16) contributes to lowering the frame error rate.

IEC 61970 CIM based Study on the application of model for Wide Area Monitoring And Control System (IEC 61970 CIM을 기반으로 한 Wide Area Monitoring And Control system 모델 적용 연구)

  • Cho, Jun-Hee;Oh, Young-Suk;Choi, Mi-Hwa;Shin, Seung-Hee;Kim, Ji-Young
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.178-179
    • /
    • 2011
  • The exchange of information with legacy systems is a main issue in the era of SMARTGRID. Because WAMAC(Wide Area Monitoring and Control) system has monitoring function, as well as control function, it is very necessary for WAMAC to exchange data and information with SCADA(Supervisory Control and Data Acquisition) / EMS(Energy Management System). IEC 61970 CIM(Common Information Model) is an abstract model that represents all the major objects in an electric utility enterprise typically involved in utility operations. In this paper, a proposal that adopting CIM to WAMAC model be submitted so that the integration of various legacy system and application for itself be able to be flexible.

  • PDF