• 제목/요약/키워드: Superconducting Fault Current Limiters

검색결과 117건 처리시간 0.025초

송.배전급 저항형 초전도 한류기 설계 요소 검출을 위한 고온 초전도 선재의 특성 연구 (Experimental Study on the High Temperature Superconductor for Investigated Design Factors of Distribution and Transmission Level Resistive Type Superconductor Fault Current Limiter)

  • 나진배;장재영;조현철;황영진;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권3호
    • /
    • pp.10-13
    • /
    • 2011
  • The power demand is steadily increasing due to rapidly develop of industrial field. The ratio of prospected increment of power consumption is over 2.2 % per year from 2007 to 2020 year. The superconducting fault current limiters(SFCLs) should be suggested to be one of promising machines to protect power grid. Four basis tests such as resistivity, short-circuit tests, ac losses and recovery time were investigated according to various reached maximum temperature, operating temperature. This paper deals with investigation of the various commercial high temperature superconductor for applying resistive type SFCLs.

직렬연결된 저항형 한류기의 동시퀜치 현상 (Simultaneous quenching phenomena of resistive superconducting fault current limiter connected in series)

  • 최효상;김혜림;임해용;김인선;현옥배
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.91-94
    • /
    • 2000
  • We fabricated resistive super- conducting fault current limiters (SFCL) based on YBCO thin films grown on 2" diameter $Al_{2}O_{3}$ substrates. Two SFCLs with nearly identical properties. two SFCLs with nearly identical properties were connected in series to investigate simultaneous quenching. There was a difference of several half cycles in their quench starting time, although the difference was not more than 0.1 msec when they were operated separately. This imbalance was removed by connecting a shunt resistor to an SFCL in parallel. Increased power input at high voltages also reduced the initial imbalance in power dissipation. Further efforts on the simultaneous quench in SFCLs connected in series are on the way through methods such as the artificial control of quench speed.peed.

  • PDF

고온초전도 한류기의 절연설계를 위한 과냉각 액체질소의 절연내력 특성 (Dielectric Characteristics of Subcooled $LN_2$ for Insulation Design of HTS Fault Current Limiters)

  • 백승명;정종만;김상현
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제5권2호
    • /
    • pp.46-50
    • /
    • 2003
  • In the dielectric insulation design of any high temperature superconducting (HTS) apparatus as well as HTS fault current limiter in the electrical power systems, the breakdown characteristics of cryogenic coolants such as liquid nitrogen ($LN_2$) are an important factor of the insulating engineering. Previous reports concerned with the breakdown characteristics of liquid nitrogen have pointed out that bubbles and gaseous nitrogen have a treat influence on their breakdown phenomena, However, useful data for practical insulation design of HTS fault CUITent limiter operating at subcooled L$N_2$ have not been obtained enough. Therefore, this paper presents an experimental investigate of breakdown phenomena in liquid nitrogen under AC voltage, And, we observed the breakdown voltage (BDV) of liquid nitrogen with lowering temperature. The Weibull plots of the breakdown voltage of subcooled $LN_2$ for the needle-plane electrode with d= 10 mm are studied, The dependence of breakdown voltage for needle-plane and pancake coil-pancake coil electrode on temperature is illustrated, The relationship between the AC breakdown characteristics and the temperature were clarified.

Quench characteristics of YBCO thin films using magnetic field source for superconducting fault current limiters

  • Lee, B.W.;Park, K.B.;Kang, J.S.;Oh, I.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제6권2호
    • /
    • pp.11-14
    • /
    • 2004
  • YBCO thin films have good characteristics for current limiting materials due to compact size and high current carrying capability. But the irregularities and the extreme thin thickness of YBCO films cause some difficulties in simultaneous quench and thermal shock protection. In order to solve these problems, vertical magnetic field generated from solenoid coil was applied to the YBCO element. And also to minimize the inductance caused by the serial connection of magnetic field source with superconducting elements, magnetic field source was separated from the power lines adapting protective current transformer. In this study, electric field-current (E-I) and quench characteristics of YBCO films were analyzed both by electrical measuring method and observations of bubble propagation. From the experiment results, it was revealed that the magnetic fields generated by surrounding coil could induce the uniform quench distribution for all stripes of current limiting units and finally simultaneous quenches were realized in all serial connection of YBCO elements. In addition, the separation of magnetic field source form electrical network could be good solution for simultaneous quench of YBCO films without any unnecessary effect caused by serial connection.

과냉질소 냉각시스템 가압용 기체의 절연내력특성 분석 (Analysis on the Dielectric Characteristics of Various Insulation Gases for Developing a Sub-cooled Liquid Nitrogen Cooling System)

  • 강형구;고태국
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권1호
    • /
    • pp.27-30
    • /
    • 2011
  • A sub-cooled liquid nitrogen cooling system is known as a most promising method to develop large scale superconducting apparatuses such as superconducting fault current limiters and superconducting cables [1]. Gaseous helium (GHe), gaseous nitrogen ($GN_2$) and sulfur hexafluoride ($SF_6$) are commonly used for designing an high voltage applied superconducting device as an injection gaseous medium [2, 3]. In this paper, the analysis on the dielectric characteristics of GHe, $GN_2$ and $SF_6$ are conducted by designing and manufacturing sphere-to-plane electrode systems. The AC withstand voltage experiments on the various gaseous insulation media are carried out and the results are analyzed by using finite element method (FEM) considering field utilization factors (${\xi}$). It is found that the electric field intensity at sparkover ($E_{MAX}$) of insulation media exponentially decreases according to ${\xi}$ increases. Also, the empirical expressions of the functional relations between $E_{MAX}$ and ${\xi}$ of insulation media are deduced by dielectric experiments and computational analyses. It is expected that the electrical insulation design of applied superconducting devices could be performed by using the deduced empirical formulae without dielectric experiments.

액체질소 내에서 뇌 임펄스전압에 대한 압력별 GFRP의 절연파괴 특성 분석 (A Study on the Dielectric Characteristics of GFRP in LN2 under Lightning Impulse Voltage According to Pressure)

  • 홍종기;허정일;남석호;강형구
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1471-1476
    • /
    • 2012
  • A study on the dielectric characteristics of the Glass Fiber Reinforced Plastic (GFRP) is important for designing a reliable high voltage superconducting machines such as transmission superconducting fault current limiters, superconducting cables, and superconducting transformers. In this paper, dielectric experiments of the GFRP under lightning impulse voltage are conducted in liquid nitrogen($LN_2$) according to various experimental conditions such as the thicknesses of the GFRP, the diameters of electrode systems and the pressures. The dielectric characteristics of the GFRP are analyzed by using a Finite Elements Method(FEM) according to various field utilization factors. It has been reported that the electrical insulation design of the GFRP would be conducted by considering the mean electric field intensity($E_{mean}$) distributed inside the GFRP. In this study, it is found that the dielectric performance of the GFRP could be explained by not only $E_{mean}$ but also the maximum electric field intensity ($E_{max}$). Finally, the empirical formulae of the GFRP to estimate an electrical breakdown voltage at sparkover under the lightning impulse condition are deduced. It is expected that the presented experimental results in this paper are helpful to design electrically reliable high voltage superconducting machines using the GFRP as an insulation material.

몰드 디자인과 냉각조건이 Bi2212 초전도튜브에 미치는 영향 (Effect of Bi2212 Tubes Depending on Mold-design and Cooling Conditions)

  • 이남일;장건익;오일성;박권배
    • Progress in Superconductivity
    • /
    • 제8권1호
    • /
    • pp.104-107
    • /
    • 2006
  • For the practical application on SCFCL(Superconducting fault current limiters), Bi-2212 tubes were fabricated by Centrifugal Forming Process(CFP). The tubes were annealed at 830, 840, $850^{\circ}C$, respectively for 80 hours in oxygen atmosphere. The tubes heat treated at $840^{\circ}C$ demonstrated better electric characteristics than the tubes heat treated at 830 and $850^{\circ}C$. The typical value measured at 77 K in the self field was around 556 A. In terms of cooling effect on superconducting properties, it was found the electrical properties were quite dependent on the mold design and shapes. In order to check uniformity along the tube, EFDLab fur heat and fluid analysis of NIKA was adopted. It was found out that the simulation data was quite well matched with experimental results.

  • PDF

자속구속형 고온초전도 전류제한기의 퀜치특성 (Quench characteristic of flux-lock type HTSC FCL)

  • 임성훈;최효상;강형곤;고석철;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2003년도 춘계학술대회 논문집 초전도 자성체 연구회
    • /
    • pp.77-79
    • /
    • 2003
  • The quench characteristics of flux-lock type high-Tc superconducting fault current limiters(SFCL) was investigated. $YBa_2Cu_3O_{7-x}$(YBCO) thin film was used as the current limiting elements of the flux-lock type SFCL. The quench characteristics of current limiting elements consisting of the flux-lock type SFCL was more improved than that of the resistive type SFCL.

  • PDF

박막형 대면적 초전도 한류소자에서의 저항 분포 (Resistance distribution in large area thin film type SFCLS)

  • 김혜림;최효상;현옥배
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.89-93
    • /
    • 2002
  • We investigated the resistance distribution n 4"diameter SFCLS. $YBa_2CU_3O_7$ films coated in-situ with a gold layer were patterned into 3 mm wide 142 cm long meander lines by Photolithography. The limiters were tested with simulated fault currents. The resistance was uniform all over the film except at the edge. At lower source voltages, CFCLs did not quench simultaneously and the resistance distribution was less uniform. Compared with 2" diameter SFCLS 4" SFCLS had similar values and time dependence of resistivity at similar electric fields The resistance distribution was more uniform in 4" SFCLS. The area at the edge where the distribution was not uniform was around 3 mm wide in SFCLs of both sizes. The experimental results were quantitatively explained with a heat transfer concept.

Electromagnetic Behavior of High -$T_c$ Superconductors underthequenchstate -

  • 정동철;최효상;황종선;윤기웅;한병성
    • Progress in Superconductivity
    • /
    • 제3권2호
    • /
    • pp.183-187
    • /
    • 2002
  • In this paper we analyzed the electromagnetic behavior of high $-T_{c}$ superconductor under the quench state using finite element method. Poisson equation was used in finite element analysis as a governing equation and was solved using algebra equation using Gallerkin method. We first investigate d the electromagnetic behavior of U-type superconductor. Finally we applied our analysis techniques to 5.5 kVA meander-line superconducting fault current limiters (SFCL) which are currently developed by many power-system researcher in the world. Meshes of 14,600 elements were used in analysis of this SFCL. Analysis results show that the distribution of current density was concentrated to inner curvature in meander-line type-superconductors and maximum current density 14.61 $A/\m^2$ and also maximum Joule heat was 6,420 W/㎥. We concluded that this meander line-type SFCL was not pertinet fur uniform electromagnetic field distribution.n.

  • PDF