• Title/Summary/Keyword: Super retarding agent

Search Result 40, Processing Time 0.021 seconds

Effect of pouring range of super retarding concrete using fly ash on water Permeability and splitting tensile strength of construction joints (플라이애시를 사용한 초지연 콘크리트의 타설범위가 시공줄눈의 수밀성 및 쪼갬인장강도에 미치는 영향)

  • Jeong, Jun-Taek;Park, Jae-Woong;Jeong, Yeong-Jin;Lim, Gun-Su;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.23-24
    • /
    • 2023
  • This study attempted to derive an appropriate application range by reviewing the integration performance of joints according to the application range of SRA concrete. As a result, it was confirmed that the integration performance was improved even if SRA concrete was placed only by 75mm, which is 0.5 times the thickness of the member.

  • PDF

Investigation on the Applicability for Method of Setting Time Difference by Super Retarding Agent for Reducing Hydration Heat of Transfer Girder Mass Concrete (전이보 매스콘크리트의 수화열저감을 위한 초지연제 응결시간차 공법의 적용가능성에 대한 검토)

  • Yoon Seob;Hwang Yin Seong;Baik Byung Hoon;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.128-131
    • /
    • 2004
  • This paper is to investigate the mock up test results of mass concrete for transfer girder using setting time difference with super retarding agent(SRA) to reduce hydration heat. According to test results, the temperature history of plain concrete without placing lift had a steep rising curvature, and plain concrete had a big temperature difference between surface and middle section of mass concrete, which may result in occurrence of temperature crack. However, considering placing method B, because setting time of middle section concrete was retarded with an increase in SRA contents, higher hydration heat temperature was observed at surface section concrete compared with that at middle section concrete at early age, which can lower the possibility of hydration heat crack. In case of placing method C, although peak temperature of hydration heat was much lower, at early age, high crack occurrence possibility of the hydration heat attributable to the big temperature difference between middle section and bottom section of concrete was expected at bottom section concrete. Therefore, the structure above the ground like transfer girder is not applicable to consider the placing method C.

  • PDF

Quantitative Analysis of Hydrate of Sugar-based Super Retardign Agent Mixed Cement Paste Using Rietveld Method (리트벨트법을 이용한 당류계 초지연성 혼화제 혼입 시멘트 페이스트의 수화생성물 정량 분석)

  • Hyun, Seung-Yong;Hu, Yun-yao;Kim, Su-Hoo;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.74-75
    • /
    • 2021
  • This study attempted to study the setting time and compressive strength according to the sugar type through XRD. Setting time was found to be delayed the most when mixing white sugar, and setting time was promoted when mixing Saccharin and Aspartame. It was found that when white sugar and Grosvener siraitia were mixed, the compressive strength was higher than that of Control. Aspartame the age passed, C3S decreased and Ca(OH)2 increased.

  • PDF

Setting and Micro-structures of the Cement Pastes Using Sugar-Based Super Retarding Agents (당류계 초지연성 혼화제를 사용한 시멘트 페이스트의 응결 및 미시구조 특성)

  • Jeong, Yeong-Jin;Hyun, Seung-Yong;Han, Jun-Hui;Kim, Jong;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.23 no.6
    • /
    • pp.703-714
    • /
    • 2023
  • This research conducts a series of tests to investigate the setting retarding properties and strength development in cement pastes incorporating various types and dosages of sugar-based super retarding agents. Six such agents, including Sucrose, Sugar powder, Saccharin, Aspartame, Stevioside, and Mogroside, commercially available, were selected for evaluation. The study also examines the micro-structural properties of these cement pastes. The test mixtures were prepared using a 27.5% water-to-cement ratio and ordinary Portland cement. Micro-structural analyses were conducted using Scanning Electron Microscopy(SEM), X-Ray Diffraction(XRD), and Energy Dispersive Spectroscopy(EDS). The findings reveal that the incorporation of sucrose, sugar powder, and stevioside significantly retards the setting time. Particularly, adding 0.1% sucrose extended the setting time by approximately two-fold compared to the control(Plain) mixture. Most mixtures, barring those with sugar powder and stevioside, exhibited compressive strength comparable to the Plain mixture. Notably, with 0.2% sucrose, strength measurements were not feasible at 1 day, but at 3 days, the strength gains aligned with the Plain mixture. XRD, SEM, and EDS analyses confirmed the hydration delay(set retarding) of C3S due to sucrose, with further quantitative corroboration provided by EDS. SEM was used to verify the presence or absence of hydration products. The study concludes that sucrose, as a sugar-based retarder, offers effective set retarding capabilities and compressive strength development in concrete.

Prediction of Setting Time of Concrete Using Fly Ash and Super Retarding Agent (초지연제 및 플라이애쉬를 사용한 콘크리트의 응결시간 예측)

  • Han, Min-Cheol
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.6 s.96
    • /
    • pp.759-767
    • /
    • 2006
  • This paper presents a method to estimate the setting time of concrete using super retarding agent(SRA) and fly ash(FA) under various curing temperature conditions by applying maturity based on equivalent age. To estimate setting time, the equivalent age using apparent activation energy($E_a$) was applied. Increasing SRA content and decreasing curing temperature leads to retard initial and final set markedly. $E_a$ at the initial set and final set obtained by Arrhenius function showed differences in response to mixture type. It is estimated to be from $24{\sim}35KJ/mol$ in all mixtures, which is smaller than that of conventional mixture ranging from $30{\sim}50KJ/mol$. Based on the application of $E_a$ to Freisleben-Hansen and Pederson's equivalent age function, equivalent age is nearly constant, regardless of curing temperature and SRA contents. This implies that the concept of maturity is applicable in estimating the setting time of concrete containing SRA. A high correlation between estimated setting time and measured setting time is observed. Multi-regression model to determine appropriate dosage of SRA reflecting FA contents and equivalent age was provided. Thus, the setting time estimation method studied herein can be applicable to the concrete containing SRA and FA in construction fields.

Prediction of Setting Time of Ternary Blended Mortar According to Super-Rretarding Aagents Dosages Applying Maturity Method (적산온도 방법에 의한 초지연제 혼입율에 따른 3성분계 모르타르의 응결시간 예측)

  • Han, Soo-Hwan;Jeong, Yeong-Jin;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.233-234
    • /
    • 2021
  • This study proposed a condensation prediction method for mortar mixed with super retardant using the additive temperature method. As a result, it is believed that the condensation prediction using the additive temperature method is highly plausible.

  • PDF

Mock-up Test on the Reduction of Hydration Heat of Mass Concrete for Transfer Girder (전이보 매스콘크리트의 수화열 저감에 관한 Mock-up 실험)

  • Yoon Seob;Hwang Yin Seong;Baik Byung Hoon;Han Cheon Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.707-710
    • /
    • 2004
  • This paper reported the results of mock-up test on mass concrete for transfer girder using setting time difference of super retarding agent(SRA). According to test results, two mock-up structures were made. Plain concrete without placing layer reached maximum temperature after 24hours since placement and caused surface hydration cracks at top section. However, concrete with placing layer reached maximum temperature after 72hours and surface temperature was higher than center temperature, which did not cause surface crack. After form removing, no crack was observed at side surface of plain concrete, while concrete using SRA at mid section had surface scaling and settling crack. According to coring results, concrete with placing layer had a penetration crack from top section to bottom section. Therefore, the setting time difference method to reduce hydration heat will have difficulty in applying the mass concrete for transfer girder.

  • PDF

Effect of Joint width of SRA Concrete on Integration Performance of Construction Joints (초지연 콘크리트의 타설 범위가 시공줄눈 일체화 성능에 미치는 영향)

  • Jeong, Jun-Taek;Kim, Soo-Ho;Jeong, Yeong-Jin;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.193-194
    • /
    • 2023
  • This study attempted to derive an appropriate application range by reviewing the integration performance of joints according to the application range of SRA concrete. As a result, it was confirmed that the integration performance was improved even if SRA concrete was placed only by 75mm, which is 0.5 times the thickness of the member.

  • PDF

Estimation of the Proper Placement Range of SRA Concrete for the Integration of Cold Joints (콜드조인트 일체화를 위한 초지연 콘크리트의 적정 타설 범위 도출)

  • Jeong, Jun-Taek;Kim, Soo-Ho;Jeong, Yeong-Jin;Hyun, Seung-Yong;Kim, Jong;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.259-260
    • /
    • 2023
  • This study attempted to derive an appropriate application range by reviewing the integration performance of joints according to the application range of SRA concrete. As a result, it was confirmed that the integration performance was improved even if SRA concrete was placed only by 75mm, which is 0.5 times the thickness of the member.

  • PDF

Properties of Retard Type Stabilizing Agent for Reuse of Sludge Water of Ready Mixed Concrete (레미콘 회수수의 재활용을 위한 지연형 안정화제의 특성)

  • Lee Mun-Hwan;Lee Sea-Hyun;Park Young-Shin;Park Jae-Myung
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.1 s.85
    • /
    • pp.105-112
    • /
    • 2005
  • Stabilizing and rousing sludge water generated from washing truck mixer and batcher plant can resolve inconsistency in quality and improve strength, therefore it is essential to review how to utilize it. This research conducted experiments and studied on solids of sludge water to find out the types of stabilizing agents available in conditions of producing ready mixed concretes in Korea. The result showed that oxy carboxylic acid retarder dedicated for stabilizing sludge water was most effective in decreasing solid. However, the setting time of cement paste was retarded due to surplus reactants, but it did not impede application of ready mixed concretes. When we left the sludge water mixed with stabilizing agent, it has been noted that initial retard effect recovered to the level using just service water in 7${\~}$8 days and that it is effective to use stabilized sludge water in 2${\~}$3 days. On the other hand, saccharic type super retarding agent was also outstanding in applicability by showing similar effect. The sludge water stabilizing agents currently marketed depend on imports, therefore it is necessary to locally manufacture usable stabilizing agents and to review its usability with multi-dimensional view.