• 제목/요약/키워드: Super premium

검색결과 9건 처리시간 0.019초

Status of High-efficiency Motor Technology and MEPS

  • Jang, Kibong
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.803-808
    • /
    • 2017
  • Minimum Energy Performance Standard(MEPS) has been adapted in Korea since 2008. The efficiency standard of variable speed motors is scheduled for publication shortly. In this paper, author reviews the technical trends associated with a high efficient electric motors by reference to research papers, and reviews the research direction to prepare for IE5. This paper provides an overview of high efficiency motors. Various applications have been covered.

의치상 레진에 대한 개상용 레진의 결합 강도에 관한 연구 (THE BOND STRENGTH OF REBASE RESIN TO DENTURE BASE RESIN)

  • 김일평;조혜원;진태호
    • 대한치과보철학회지
    • /
    • 제31권4호
    • /
    • pp.515-522
    • /
    • 1993
  • The purpose of this study was to evaluate the bond strength of rebase resin to denture base resin. The denture base resins in this study were Premium Super-20(Lang Dental Mfg. Co. Inc., Wheeling, USA) and Lucitone 199(Dentsply International Inc., York, USA). And the rebase resins were Repair Acrylic(Lang Dental Mfg. Co. Inc., Wheeling USA). Toughron Rebase(Miki Chemical Product Co. Ltd., Japan) , Tokuso Rebase(Tokuyama Soda. Co. Ltd., Japan) and Triad VLC Reline Material(Dentsply International Inc., York, USA). The obtained results were as follows : 1. The bond strength of Repair Acrylic to Premium Super-20, and that of Toughron Rebase to Lucitone 199 were the highest. 2. In Premium Super-20 and Lucitone 199, bond strength of all rebase resins had significant differences. 3. The bond strength of Triad VLC Reline Material was inclined to the lowset.

  • PDF

A Performance Investigation and Comparison of Line Start-up Permanent Magnet Synchronous Motor with Super Premium Efficiency

  • Feng, Xueqing;Bao, Yaxin;Liu, Lijun;Huang, Lizhong;Zhang, Yingming
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제1권2호
    • /
    • pp.30-37
    • /
    • 2012
  • This paper presents the performance investigation and design technology of a Line Start-up Permanent Magnet Synchronous Motor (LSPMSM) with super premium efficiency, including a design consideration and evaluation for motor start-up, key performance, and advanced finite element analysis FEA) for the design, improvement and verification, prototype build and test, design and test data comparison with a $Premium^{(R)}$ Efficient Induction Motor (PEIM). To assess the design technology, the LSPMSM prototype was built amended from a PEIM with the same frame, stator punching and rated output. Based on the prototype test, two novel design improvements and analyses have been done to eliminate noise and vibration. Additionally, the comparisons with the PEIM on the power factor, efficiency, frame size and active material consumption indicated that a significant performance improvement and active material cost reduction can be achieved by the LSPMSM.

슈퍼프리미엄(IE4)급 유도전동기 대체용 동기 릴럭턴스 전동기 고효율 설계연구 (High Efficiency Design of Ie4 Class Synrm Subsituting for Induction Motor)

  • 유광현;이주
    • 조명전기설비학회논문지
    • /
    • 제29권11호
    • /
    • pp.35-40
    • /
    • 2015
  • In accordance with global energy conservation policies such as MEPS (Minimum Energy Performance Standard), electric motor industry is moving to super-high-efficiency machines and research to develop IE4 (International Energy Efficiency Class 4) motors has been launched. In this situation, SynRM (Synchronous Reluctance Motor) has been attracting attention in place of induction motor which hardly provides super premium efficiency. As a result, much research on SynRM is being performed at home and abroad. Also, some products have already been appearing in the market. Compared to induction motor, SynRM has better efficiency per unit area and wider operating range. Although the utilization of control system in synchronous motor results in higher prices, we still need to concentrate on developments of SynRM so as to comply with the new policies. This study demonstrated the electromagnetic design methods of super premium SynRM while maintaining the frame of existing IE3 induction motor. We documented the design procedures for generating high saliency which is the most essential and mechanical stress anlaysis is also treated. In conclusion, we proved the validity of our design by manufacturing and testing our 3 models.

블로워용 IE3 유도전동기 대체 IE4 동기 릴럭턴스 전동기 고효율 설계 연구 (Study on the High Efficiency Design of IE4 Synchronous Reluctance Motor Replacing IE3 Induction Motor)

  • 유회총;김인건;정제명;이주
    • 전기학회논문지
    • /
    • 제65권3호
    • /
    • pp.411-418
    • /
    • 2016
  • In accordance with global energy conservation policies such as MEPS(Minimum Energy Performance Standard), electric motor industry is moving to super-high-efficiency machines and research to develop IE4 (International Energy Efficiency Class4) motors has been launched. In this situation, SynRM (Synchronous Reluctance Motor) has been attracting attention in place of induction motor which hardly provides super premium efficiency. As a result, much research on SynRM is being performed at home and abroad. Also, some products have already been appearing in the market. Compared to induction motor, SynRM has better efficiency per unit area and wider operating range. Although the utilization of control system in synchronous motor results in higher prices, we still need to concentrate on developments of SynRM so as to comply with the new policies. This study demonstrated the electromagnetic design methods of super-premium SynRM while maintaining the frame of existing IE3 induction motor for blower. We documented the design procedures for generating high saliency which is the most essential and mechanical stress analysis is also treated. In conclusion, we proved the validity of our design by manufacturing and testing our SynRM models.

금속 표면처리방법이 니켈-크롬 합금 의치상과 첨상레진간의 결합강도에 미치는 영향 (EFFECTS OF METAL SURFACE TREATMENTS ON THE SHEAR BOND STRENGTH BETWEEN NI-CR DENTURE BASE AND RELINE RESINS)

  • 김영일;정창모;전영찬
    • 대한치과보철학회지
    • /
    • 제40권4호
    • /
    • pp.396-405
    • /
    • 2002
  • The purpose of this study was to evaluate the effects of four metal surface treatments on the shear bond strength of reline resin to Ni-Cr alloy. The denture base metal used in this study was Ni-Cr alloy(Ticonium Premium 100. Ticonium Co., U.S.A.). 120 specimens were divided into five metal surface treatments: sandblasting only, MR. BOND(Tokuyama Corp.. Japan), Cesead Opaque Primer(Kuraray Co., Japan), METALPRIMER II(GC Corp., Japan) and Super-Bond C&B(Sun Medical Co., Japan) after sandblasting. They were bonded with one of three reline resins Mild Rebaron(GC Corp., Japan), Mild Rebaron LC(GC Corp., Japan) and Meta Base M(Sun Medical Co., Japan). Then they were thermocycled 1,000 times at temperature of $4^{\circ}C$ and $60^{\circ}C$. The shear bond strengths were measured using the universal testing machine(Instron, Model 4301, England) with a cross-head speed of 2 mm/min. The results were as follows : 1. All metal primers and adhesive cement significantly improved the bond strength of reline resin to Ni-Cr alloy compared with sandblasted specimens. 2. In Mild Rebaron and Mild Rebaron LC. Cesead Opaque Primer showed the highest bond strength, but the differences among Cesead Opaque Primer, MR. BOND and METALPRIMER II were not significant. The bond strength of Cesead Opaque Primer was significantly different with that of Super-Bond C&B. 3. In Meta Base M, Super-Bond C&B showed the highest bond strength, but there was no difference between Super-Bond C&B and three metal primers. 4. There was no difference in the bond strength between Mild Rebaron and Mild Rebaron LC when metal surface was treated with the same method. 5. The bond strengths of Mild Rebaron and Mild Rebaron LC treated with Cesead Opaque Primer were higher than that of Meta Base M. The bond strengths of Mild Rebaron treated with MR. BOND and METALPRIMER II was higher than that of Meta Base M, However, there was no difference among three reline resins treated with Super-Bond C&B.

커피에 의한 의치상 레진의 색 변화에 관한 연구 (THE COLOR CHANCE OF DENTURE BASE RESINS BY COFFEE)

  • 한상훈;동진근;진태호
    • 대한치과보철학회지
    • /
    • 제31권4호
    • /
    • pp.523-531
    • /
    • 1993
  • The purpose of this study was to investigate the color change of denture base resins by coffee. Denture base resins for this study were Triad VLG Denture Base (Dentsply, York Div. U.S.A.), Premium Super-20 (Lang Dental Mfg. Co., Inc., U.S.A.) for denture base, Toughron Rebase (Miki Chemical Prod., Kyoto, Japan), Jet Repair Acrylic (Lang Dental Mfg. Co., Inc., U.S.A.), Triad Reline (Dentsply, fork Div. U.S.A.) and Tokuso Rebase (Tokuyama Soda Co., Ltd., Japan) for denture rebase. Twenty specimens of each denture base resin were made and polished. The color of specimens was measured by colorimeter (Model Tc-6FX, Tokyo Denshoku Co. Japan), and they were stored in coffee for three weeks and then color changes were measured. The obtained results were as follows : 1. The L*, a*, b* and the E*ab values of all denture base resins were changed after three weeks. 2. The amount of color change on L*, a*, b* and the E*ab value of each specimens showed different patterns. 3. The b* values of Triad Reline materials were changed more than the other materials. 4. The E*ab values of Triad Denture Base materials were changed more than the other materials.

  • PDF

의치 수리용 레진의 색안정성과 결합강도에 관한 연구 (A STUDY ON THE COLOR STABILITY AND SHEAR BOND STRENGTH OF DENTURE REPAIR RESINS)

  • 진태호
    • 대한치과보철학회지
    • /
    • 제33권1호
    • /
    • pp.24-31
    • /
    • 1995
  • This study was performed to investigate the color stability and shear bond strength of denture repair resins. The denture base resins used in this study were Premium Super-20(Lang Dental Mfg. Co., Inc.,.U.S.A.) as heat curing resin, Triad VLC Denture Base(Dentsply/York Division, U.S.A.), Triad Reline Material(Dentsply/York Division, U.S.A.), Repair Acrylic(Lang Dental Mfg. Co., Inc.,. U.S.A.), Toughron Rebase (MikiChemical Product, Kyoto, Japan), and Tokuso Rebase(Tokuyama Soda Co., Ltd., Japan) as denture repair resin. After fabrication of specimens, they stored for 20 months, then color changes and shear bond strength were measured by colorimeter(Model TC-6FX, Tokyo Denshoku Co.) and Instron Universial Test Machine. The results were as follows : 1. There were changes of $L^{\ast},\;a^{\ast},\;b^{\ast}$ and $DE^{\ast}$ in Triad VLC Denture Base after 20 months. 2. There were changes of $a^{\ast}$ in Toughron Rebase and Tokuso Rebase, and $b^{\ast}$ in Tokuso Rebase after 20 months. 3. The shear bond strength of Repair Acrylic and Toughron Rebase were higher than that of Tokuso Rebase and Triad Reline Material.

  • PDF

Holographic interferometry를 이용한 열중합 애크릴릭 레진의 변형에 관한 연구 (A STUDY ON THE DIMENSIONAL CHANGES OF HEAT CURING ACRYLIC RESINS USING HOLOGRAPHIC INTERFEROMETRY)

  • 박동관;장익태;김광남
    • 대한치과보철학회지
    • /
    • 제33권1호
    • /
    • pp.48-74
    • /
    • 1995
  • Since heat curing acrylic resins undergo unavoidable dimensional changes following polymerization, adaptation can be altered. Until recently, although numerous studies on the dimensional changes of denture base were based on a microscopic technic that measures the relative displacement of a limited reference points on the denture base, but there have been few studies on the distortions of resins using holographic interferometry. Purpose of this study was to determine and compare the dimensional changes and fringe patterns of 4 heat curing acrylic resins, and observe the distortions of acrylic resin denture base by temperature change with the aid of the holographic interferometry. Holographic interferograms were taken on the resin specimens and acrylic resin denture base with the 10mW He-Ne laser and double exposure method. Comparison and analysis of fringe pattern on the recorded object surface was performed. The following results were obtained. 1. The dimensional changes for the high impact resin Lucitone 199 were statistically the greatest of all resins, and the rapid heat curing resin Premium super 20 were the least. 2. The most polymerization shrinkage of all materials occured in initial period of measurements, at this time the difference of polymerization shrinkage properties between resins was founded. 3. The stress distribution of specimens was seen by various type of fringe pattern which had directionality. 4. The polymerization shrinkage of resins was greatly influenced by temperature change. 5. The partial deformations of resin denture base were observed in 70 C and 90 C water.

  • PDF