• 제목/요약/키워드: Sump water

검색결과 42건 처리시간 0.022초

A Hydraulic Model Stydy of the Water-Intake Structure near River Mile 37 on the Missouri River

  • Byungman-Yoon
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 1992년도 수공학연구발표회논문집
    • /
    • pp.133-141
    • /
    • 1992
  • A three water-intake structure designed to built along the right bank of the Missouri River near Chesterfield, Missouri was model-tested at an undistorted scale of 1:5. Although the discharge capacity of each of six pumps to be installed is only 21,000 gpm, the model indicated strong flow circuation and unstable free-surface conditions as flow entered the two-pump bay through a narrow sluice opening at an angle. Strong free-surface vartices were also observed in the model. The sump modifications developed in the study included an array of baffle bars, a perforated plate, floor splitters, and floor-corner fillets. The solutions developed in this study could be applied to other pump sumps with multiple pump units.

  • PDF

수리실험을 이용한 발전소의 순환수 취수부 흡입수조의 와류저감에 관한 연구 (On Vortex Reduction Characteristics of Pump Sump Circulating Water Intake Basin of Power Plant Using Hydraulic Experiment)

  • 엄중현;이두한;김형수
    • 대한토목학회논문집
    • /
    • 제42권6호
    • /
    • pp.815-824
    • /
    • 2022
  • 발전소의 주요시설 중 발전 시스템 냉각용으로 사용되는 순환수는 순환수 취수부(Circulation Water Intake Basin)를 통해 공급된다. 순환수 취수부 중 흡입수조(Pump Sump)에서 발생하는 다양한 형태의 와류는 순환수펌프(Circulation Water Pump) 및 관로에 악영향을 미친다. 특히, 공기의 흡입을 동반한 자유표면 와류는 진동, 소음, 공동현상 등을 발생시켜 순환수펌프의 성능 저하, 관로의 손상을 일으키며 발전이 중단되는 주요 원인이 된다. 따라서 수리모형 실험을 통해 순환수 취수부에 대한 수리특성을 반드시 확인하고, 와류 발생 시 와류를 제어할 수 있는 적절한 와류제어장치(Anti Vortex Device)를 적용하여 원활한 발전소 운영이 가능하도록 해야 한다. 자유표면 와류 저감을 위해 와류제어장치 중커튼월(Curtain Wall)을 사용하는 것이 일반적이며, 자세한 내용은 American National Standard for Pump Intake Design에서 기술하고 있다. 본 연구에서는 리비아 Tripoli West 4×350 MW 발전소의 순환수 취수부를 대상으로 하였으며, 실제 운영조건을 적용하고, 수리모형 실험을 통해 순환수 취수부 중 흡입수조에서 발생하는 와류제어장치의 와류저감 효과를 분석하였다. 또한, 수중와류 제어를 위해 플로어 스플리터(floor splitter)는 기본적으로 적용하였고, 자유표면에서 발생하는 와류제어를 위해 새로운 형태인 컬럼 커튼월(Column Curtain Wall)을 추가적으로 적용하여 효과를 확인하였다. 본 연구에서는 일반적으로 적용되었던 커튼월에 새로 개발한 컬럼 커튼월을 추가적으로 적용하여 수리특성을 분석한 결과, 균일한 흐름이 형성되면서 와류가 제어되는 것을 확인하였다. 또한, 순환수펌프 관로 내에서 발생하는 와류각도는 ANSI/HI 9.8의 설계기준인 5° 이하로 나타나 흐름의 안정성을 확인하였다.

수리구조 개선을 통한 다중 펌프 흡수정에서 발생하는 보텍스 방지 대책 수립에 관한 연구 (Modifications to Hydraulic Structures for Anti-submerged Vortex in a Multi Pump Intake using CFD simulation Technique)

  • 박노석;김성수;정우창;김종오
    • 상하수도학회지
    • /
    • 제25권1호
    • /
    • pp.31-39
    • /
    • 2011
  • In order to suggest the methodology for achieving anti-vortex device within multi pump intake well, CFD(Computational Fluid Dynamics) simulation were conducted for two alternative suggestions. Multi-intake sump model with anti-vortex device basins were designed and the characteristics of submerged vortex were investigated in the flow field by numerical simulation. From the results of simulations, to install the horizontal plate and vertical cross plates within basins were effective for preventing air-induction vortex.

PIV를 이용한 흡수조 내 유속분포 및 와류강도 측정에 대한 연구 (A Study of the Velocity Distribution and Vorticity Measurement in the Pump Sump Using PIV)

  • 변현혁;김서준;윤병만
    • 대한토목학회논문집
    • /
    • 제40권2호
    • /
    • pp.145-156
    • /
    • 2020
  • 최근 도시지역의 불투수율 증가로 인해 내수침수 위험성이 증가하고 있다. 이에 도시침수 방지대책으로 빗물펌프장의 증설 및 신설에 대한 필요성이 부각되고 있다. 빗물펌프장의 효율을 증가시키기 위해서는 흡수조에서 발생하는 와류의 제어가 필요하다. 따라서 와류를 효과적으로 제어하기 위해서 펌프 흡수조 내 흐름특성 분석이 필요하다. 이에 본 연구에서는 입자영상유속측정법을 이용하여 흡수조 내 유속분포 및 와류강도를 측정하기 위한 촬영 및 분석 조건들에 대한 민감도 분석을 실시하여 흡수조 내 유속 및 와류강도 측정의 한계를 확인하고 최적 방법들을 제시하고자 한다. 이를 위해 우선 레이저를 이용하여 흡수조 내 흐름을 촬영하였고, 상관영역 크기와 촬영 시간간격 및 측점 간격의 변화에 따른 유속분포와 와도분포를 비교하여 민감도를 검토하였다. 본 연구에서 대상으로 한 흐름조건의 자유수면와류의 경우 상관영역 크기가 와류 크기의 약 13 % 이상에서는 유속 산정 정확도가 감소하는 것으로 나타났으며, 연속되는 두 장의 영상 간 입자의 변위가 1 mm 이상이 되면 연직방향의 흐름 때문에 이탈되는 입자들이 많아져 정확도가 감소하는 것으로 나타났다. 또한 자유수면와류가 차지하는 격자의 개수가 증가할수록 와도의 크기가 커지는 것으로 나타났다. 이와 같은 연구결과는 입자영상유속계를 활용한 흡수조 내 유속분포 및 와류강도 측정 시 촬영 및 영상분석 조건을 결정하는데 기초자료로 활용될 것으로 기대된다.

LOCA이후 환경에서 원자로건물집수조 여과기의 수두손실에 대한 화학적 영향 (Chemical Effects on Head Loss across Containment Sump Strainer under Post-LOCA Environment)

  • 구희권;정범영;홍광;정은선;정현준;박병기;이인형;박종운
    • 한국산학기술학회논문지
    • /
    • 제10권11호
    • /
    • pp.3260-3268
    • /
    • 2009
  • 냉각재상실사고이후 원전의 원자로건물집수조 여과기에서 화학적 영향을 고려한 수두손실을 종합적으로 평가하기 위한 시험장치를 개발하였다. 시험장치에서 원자로건물집수조와 시험장치에서 물 부피에 대한 여과기 면적의 비가 일치하도록 시험조건을 설정하고 시험을 수행하였다. TSP pH 조절제 조건에서 칼슘실리케이트는 시험 초기에 수두손실을 급격히 상승시켰기 때문에 원자로건물에서 모든 칼슘실리케이트를 제거하여야 함을 확인하였다. 비상노심냉각계통 살수지속시간의 차이에 따른 시험결과는 장기살수조건이 단기살수조건에 비해 12배 정도 높은 수두손실을 보였다. 살수조건 시험결과를 화학적 영향이 없는 수두손실과 비교하면 단기살수와 장기살수의 각 조건에서 5.6배 및 60.8배 수두손실이 증가하는 결과를 보였다. 화학적 영향은 재순환수에 노출된 물질의 양에 따라 초기의 일정기간 동안 알루미늄 및 아연도금 판의 부식에 의해 급격히 증가하고 이들이 부동피막을 형성한 이후에는 NUKONTM 및 콘크리트 등에서 침출된 화학종의 침전에 기인하여 증가율이 감소하는 경향을 보였다. 실험결과는 TSP에 의한 알루미늄의 부동피막 형성이 살수시간이 길어지고 알루미늄의 양이 많을 경우 효과적이지 않다는 것을 보였다.

Vortex-Disc형 유회수기의 성능평가 (Performance Test of Vortex-Disc Skimmers)

  • 유정석
    • 한국해양환경ㆍ에너지학회지
    • /
    • 제2권2호
    • /
    • pp.95-102
    • /
    • 1999
  • Various types of oil response equipments and oil recovery vessels are being developed in Korea from the 1990s to respond nil spill accidents. It should be considered prior to the selection of the oil skimmers to make the oil recovery system more efficient at early stage of oil spill accidents. Rotating baldes of vortex skimmer beneath the water surface concentrate oil and draw it into the weir, where it flows to a collection sump. In this study a recently developed Vortex-Disc skimmer(model : VDS-50) is introduced and the performance test results for the skimmer are discussed.

  • PDF

빔튜브파단 냉각재상실사고시 원자로냉각수 보충방법 변경이 리스크에 미치는 영향 (Effect of Change of Reactor Coolant Injection Method on Risk at Loss of Coolant Accident due to Beam Tube Rupture)

  • 이윤환;이병희;장승철
    • 한국안전학회지
    • /
    • 제37권4호
    • /
    • pp.129-138
    • /
    • 2022
  • A new method for injecting cooling water into the Korean research reactor (KRR) in the event of beam tube rupture is proposed in this paper. Moreover, the research evaluates the risk to the reactor core in terms of core damage frequency (CDF). The proposed method maintains the cooling water in the chimney at a certain level in the tank to prevent nuclear fuel damage solely by gravitational coolant feeding from the emergency water supply system (EWSS). This technique does not require sump recirculation operations described in the current procedure for resolving beam tube accidents. The reduction in the risk to the core in the event of beam tube rupture that can be achieved by the proposed change in the cooling water injection design is quantified as follows. 1) The total CDF of the KRR for the proposed design change is approximately 4.17E-06/yr, which is 8.4% lower than the CDF of the current design (4.55E-06/yr). 2) The CDF for beam tube rupture is 7.10E-08/yr, which represents an 84.1% decrease compared with that of the current design (4.49E-07/yr). In addition to this quantitative reduction in risk, the modified cooling water injection design maintains a supply of pure coolant to the EWSS tank. This means that the reactor does not require decontamination after an accident. Thermal hydraulic analysis proves that the water level in the reactor pool does not cause damage to the nuclear fuel cladding after beam tube rupture. This is because the amount of water in the chimney can be regulated by the EWSS function. The EWSS supplies emergency water to the reactor core to compensate for the evaporation of coolant in the core, thus allowing water to cover the fuel assemblies in the reactor core over a sufficient amount of time.

Analysis on Chemical Ingredients with Anti-microbial Activity in Water-based Metalworking Fluids

  • Park, Dong-Uk;Kim, Bok-Hwan;Lee, Kwon-Sup
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2004년도 International Conference Global Environmental Problems and their Health Consequences
    • /
    • pp.217-222
    • /
    • 2004
  • This study was conducted to estimate if the level of several chemical ingredients including alkanolamines or ethanolamines (EA) examined in the specific synthetic metalworking fluid (MWF) ‘A’ can cause anti-microbial activity and health effect. Three water-based MWF products (‘A’, ‘B’, and ‘C’) were studied every week for two months. Chemical ingredients such as formaldehyde, boron, EA, and copper were examined. In the sump where MWF ‘A’ was used, not only the total level of EA, monoethanolamine(MEA), diethanolamine(DEA) and triethanolamine(TEA), but also boron level were significantly higher than those of the other MWFs. ANOVA statistical tests indicated that levels of pH, alkalinity, boron, MEA, DEA and TEA in MWF ‘A’ were significantly higher than those in other MWF types. Correlation tests also found that levels of pH, alkalinity, boron, MEA, DEA and TEA in MWF ‘A’ are significantly correlated. We suggested the assumptions that excessive concentrations of EA, and borate at a high pH level, may cause anti-microbial resistance synergically. To demonstrate this assumption, additional study is needed to examine the relationship between the levels of microbes and excessive concentrations of EA, and borate at a high pH level.

  • PDF

기계가공 공정에서 금속가공유 관리에 대한 평가지침 -수용성 금속가공유를 중심으로- (Assessment guideline for the safe use of metalworking fluids - Focused on water-soluble metalworking fluids)

  • 박동욱
    • 한국산업보건학회지
    • /
    • 제20권2호
    • /
    • pp.131-138
    • /
    • 2010
  • This technical report was developed to suggest the guideline to assess the safe use and handling metalworking fluids (MWFs) in machining operation. The basis of this method developed in this study was based on self assessment procedure recommended by Organization Resources Counselors (ORC) of the United States (US). In addition, various MWF management elements obtained from the review on various articles, reports and author's experience regarding MWF were newly added to the evaluation guideline. A total of four areas were finally selected in order to control exposure to MWF used in machining operations. They are all related to the presence and efficiency of the control measures, exposure assessment, management on tank and sump, and safe treatment of chips and metal fines generated during machining operations. Each area is consisted of several related elements. Several evaluation areas and elements used in this study could be revised, replaced, added and deleted according to the process environment, evaluation objectives and evaluator's (manager) criteria etc. This evaluation guide manual could be used for safe management of MWF in metalworking operation. In addition, industrial hygienists can use this evaluation method for auditing and evaluating the management status on MWF.

Analysis on Chemical Ingredients with Anti-microbial Activity in Water-based Metalworking Fluids

  • Park, Donguk;Lee, Jonghang;Lee, Kwonsup
    • KSTLE International Journal
    • /
    • 제4권2호
    • /
    • pp.52-55
    • /
    • 2003
  • This study was conducted to estimate if the level of several chemical ingredients including alkanolamines or ethanolamines (EA) examined in the specific synthetic metalworking fluid (MWF) "A" can cause anti-microbial activity and health effect. Three water-based MWF products ("A", "B", and "C") were studied every week for two months (from June 1, 2002 to July 30, 2002). Chemical ingredients such as formaldehyde, boron, EA, and copper were examined. In the sump where MWF "A" was used, not only the total level of EA, monoethanolamine(MEA), diethanolamine(DEA) and triethanolamine(TEA), but also boron level were significantly higher than those of the other MWFs. ANOVA statistical tests indicated that levels of pH, alkalinity, boron, MEA, DEA and TEA in MWF "A" were significantly higher than those in other MWF types. Correlation tests also found that levels of pH, alkalinity, boron, MEA, DEA and TEA in MWF "A" are significantly correlated. We suggested the assumptions that excessive concentrations of EA, and borate at a high pH level, may cause anti-microbial resistance synergically. To demonstrate this assumption, additional study is needed to examine the relationship between the levels of microbes and excessive concentrations of EA, and borate at a high pH level.