• Title/Summary/Keyword: Summer Power

Search Result 400, Processing Time 0.026 seconds

The Maximum Demand Power Reduction of Small Industrial Factory based on Microgrid (마이크로그리드를 기반으로 한 중소 산업용수용가의 최대수요전력 저감방안)

  • Chang, Hong-Soon;Kim, Cherl-Jin;Park, Sang-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.1
    • /
    • pp.7-14
    • /
    • 2017
  • Recently, the power consumption of industrial consumer has increased rapidly, causing problems such as lack of power reserve margin in summer and winter, and therefore there is a growing need for maximum demand power management to consumers. In this paper, we studied small microgrid system consisting of battery ESS and photovoltaic power system, applied to small and medium sized factories to reduce the maximum demand power of daily industrial power load. To verify the validity of the study, we simulated a small microgrid system using Matlab/Simulink software. As a result of applying the simulation to small and medium sized plants that consume a lot of power, it is confirmed that there is a 13% reduction in demand compared to the existing maximum demand power. This result is expected to contribute to the improvement of the power reserve margin.

A Study on Power System Characteristics and Economic Benefit by Operating the New SIHWA Tidal Power Plant (시화호 조력발전소 신설에 따른 전력계통 특성 및 경제적 이득 분석)

  • Kim, Kyu-Ho;Song, Kyung-Bin;Kim, Sang-Min;Lee, Mu-Sung;Choi, Hong-Seok
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.6
    • /
    • pp.791-796
    • /
    • 2012
  • This paper presents the various analysis of the power system for operating the new SIHWA tidal power plant. In the analysis of the power system, summer load condition of 2011 is used. Especially, power flow, fault current, voltage and contingency of SIHWA tidal power plant area are analyzed by using PSS/E and there is no problem for the dynamic stability simulation. The new SIHWA tidal power plant is located in near metropolitan area where about 43% amount of the system load is consumed. Therefore, transmission losses are reduced. In addition, system marginal price can be lowered by generating the new SIHWA tidal power plant. The generation pattern of the SIHWA tidal plant is analyzed and the changes of generation are presented for various water levels by control of the rotor angle alpha and beta in water wheel generator.

Estimation of Electricity Price of the Imported Power via Interstate Electric Power System in North-East Asia (동북아 전력계통 연계를 통한 융통전력 도입 시 가격상한 수준에 대한 분석)

  • Kim, Hong-Heun;Chung, Koo-Hyung;Kim, Bal-Ho
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.55 no.3
    • /
    • pp.128-132
    • /
    • 2006
  • Interstate electric power system, as an alternative for energy cooperation under regional economic bloc, has been hotly debated before progressing the restructure in electric power industry and rapidly expanded in many regions after 1990s. Especially, since northeast asia has strong supplementation in resource, load shape, fuel mix etc., electric power system interconnection in this region may bring considerable economic benefits. Moreover, since Korean electric power system has a great difficulty in a geographical condition to interrupt electricity transaction with other countries, it has been expanded as an independent system to supply all demand domestically. As a result, Korean electric power system makes considerable payment for maintaining system security and reliability and expands costly facilities to supply a temporary summer peak demand. Under this inefficiency, if there are electricity transactions with Russia via the North Korea route then economic electric power system operation nay be achieved using seasonal and hourly differences in electricity price and/or load pattern among these countries. In this paper, we estimate price cap of transacted electricity via interstate electric power system in northeast asia. For this study, we perform quantitative economic analysis on various system interconnection scenarios.

A Study on the Load Management for the Stability of Power Supply in summer (하계전력수급 안정을 위한 부하관리 대책)

  • Cho, Kyou-Seung;Kang, Won-Koo;Lee, Youn-Seob
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.17-18
    • /
    • 1991
  • In electric Industry, the improvement of load factor by flattening load has been considered to be more important than any other tasks and has received wide concern and interest. Especially while annual peak load had occurred early evening in winter during past decades, but we found the trend has changed so that annual peak load occurred during the daytime in summer since 1981. In this paper we introduce various method for the load management.

  • PDF

Oceanography in the Waters Adjacent to Kamchatka and Kurile islands in the Northwestern Pacific - II (북서태평양 명태 어장의 해황 - 2 . 기후의 특성 -)

  • Han, Young-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.13 no.1
    • /
    • pp.17-25
    • /
    • 1977
  • For four calender years (1971-1974), daily observations of weather conditions (air temperature, humidity, wind speed, wind direction, cloud amount, fog, precipitation etc.) at six stations in the north western Pacific Ocean are used to calculate mean monthly values and to check extra-conditions. At Petropavlosk and Miko'skoe, where indicate the characteristics of modified continental climate, the temperature and humidity are high in summer, and Iow in winter. At A Dak and She Mya, where indicate the characteristics of warm current type maritime climate, humidity is high in all season and annual range of air temperature is nearly negligible. At Simusir and Vasi!' eva, where indicate the characteristics of cold current type maritime climate, humidity is high in all season and annual range of air temperature is $15^{\circ}C.$ As dry cooling power is relatively high in winter, working condition on deck is bad. Most of fogs are advection fog in the area of cold current type climate in summer.

  • PDF

The investigation of field condition on flood protection of substation and underground power equipment (pad-mounted transformers & switches) (수변전실 및 지중 배전기기의 침수 방지 관련 현장 조사 분석)

  • Kim, Gi-Hyun;Choi, Myeong-Il;Bae, Suk-Myong;Lee, Jae-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.327-331
    • /
    • 2007
  • Inundation of substation and underground power equipment(pad-mounted transformers & switches) breaks out every summer season in low-lying downtown and low-lying shore by localized heavy rain, typhoon and tidal wave. In case inundation of substation and underground power equipment, it occurs a great economic loss owing to recovery time and events of electric shock occur by inundation electrical facility. So we search the damage situation and installation situations. Therefore we propose the necessity of protection of flood at low-lying downtown and low-tying shore. This paper will be used to present a reform proposal of electrical related law about flood protection of existing power equipment.

  • PDF

Practical Analysys to enhance the Reliability of Power IT Systems during summer peak (하계피크 대비 전력IT 신뢰도 향상방안에 관한 실증분석)

  • Sa, Gwan-Joo;Kim, Chul-Sik;Lee, Soung-Eun
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.6-8
    • /
    • 2007
  • EMS, MOS, CBP시스템을 포괄하는 전력 IT시스템의 하절기 전력수요 피크대비 전력IT 신뢰도 향상방안에 대한 결과를 분석하였다. 먼저 신뢰도 향상을 위한 하절기 대비 운영계획을 수립하고 운영계획에 따라 정책과 운영 그리고 장애에 따른 유지보수를 시행하여 전력IT 종합신뢰도를 99.74%를 달성하였다. 향후에는 미흡한 점을 보완하여 2008년 하절기에는 운영기술을 향상시키고 기술축적을 통하여 전력계통운영 선진화 및 공정하고 투명한 전력거래시스템 운영에 만전을 기하고자 한다.

  • PDF

A Measurement of electricity power consumption of houses located at south coastal fishing village (남해안 어촌주거시설의 전력 소비량 실측)

  • Koo, Jae-Hyeok;Cho, Hyung-O;Hwang, Kwang-Il
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.06a
    • /
    • pp.50-51
    • /
    • 2012
  • The final purpose of this study is to develop a hybrid ocean power generation system which has innovate and very high efficiency performance, and which can be operated on both emergency and normal conditions. So, A survey on the electricity power consumption of residential areas at island on south coast.

  • PDF

Analysis of closing surge in static condenser bank using EMTP (EMTP를 이용한 스타콘뱅크의 투입써-지 해석)

  • Won, Young-Jin;Seo, Soon-Gyo;Jung, Tay-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1992.07b
    • /
    • pp.673-675
    • /
    • 1992
  • The operation of condenser-bank is now increasing around Kyoungin area. The operation of condenser-bank is used for the improvement of under voltage and expand of power demand. But the operation has the problem in itself as the switching over voltage. This report deals with the static-condenser fault caused by abnormal operation of circuit breaker which has occurred last summer. We have analyzed this fault using EMTP(electromagnetic transient program).

  • PDF

Investigation on the Wave Power Resources on the East Coast of Korea Based on Field Measurement Data (실측자료에 근거한 동해안 파력 부존량 검토)

  • Jeong, Weon-Mu;Oh, Sang-Ho;Lee, Dal-Soo;Lee, Dong-Young
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.630-634
    • /
    • 2007
  • In the past, the use of wave energy has mainly been focused on conversion of large wave energy resources in the far offshore areas. However, with the technological improvement of converting wave energy into electricity, the energy resources at much shallow waters are now considered as a site for possible installation of the devices that obtain energy from the waves. In this respect, the wave energy resources on the east coast of Korea, where the sea is milder than the open ocean, were investigated using the field measurement data obtained at three different locations along the coast. For all the locations, the wave power was greater in winter season, compared to summer season. The estimated wave power varied from 2 to 4.5 kW/m on average, depending on the measurement locations.

  • PDF