• Title/Summary/Keyword: Summer Power

Search Result 400, Processing Time 0.028 seconds

Heating and Cooling Performance Analysis of Ground Source Heat Pump System in Low Energy House (저에너지주택의 지열히트펌프시스템 냉·난방 성능분석)

  • Baek, Namchoon;Kim, Sungbum;Shin, Ucheul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.10
    • /
    • pp.387-393
    • /
    • 2016
  • A ground source heat pump system maintains a constant efficiency due to its stable heat source and radiant heat temperature which provide a more effective thermal performance than that of the air source heat pump system. As an eco-friendly renewable energy source, it can reduce electric power and carbon dioxide. In this study, we analyzed one year of data from a web based remote monitoring system to estimate the thermal performance of GSHP with the capacity of 3RT, which is installed in a low energy house located in Daejeon, Korea. This GSHP system is a hybrid system connected to a solar hot water system. Cold and hot water stored in a buffer tank is supplied to six ceiling cassette type fan coil units and a floor panel heating system installed in each room. The results are as follows. First, the GSHP system was operated for ten minutes intermittently in summer in order to decrease the heat load caused by super-insulation. Second, the energy consumption in winter where the system was operated throughout the entire day was 7.5 times higher than that in summer. Moreover, the annual COP of the heating and cooling system was 4.1 in summer and 4.2 in winter, showing little difference. Third, the outlet temperature of the ground heat exchanger in winter decreased from $13^{\circ}C$ in November to $9^{\circ}C$ in February, while that in summer increased from $14^{\circ}C$ to $17^{\circ}C$ showing that the temperature change in winter is greater than that in summer.

Research on using the exhausted heat from subway tunnel as unused energy (미활용 에너지원으로서의 지하철 배열이용에 관한 연구)

  • 김종렬;금종수;최광환;윤정인;박준택;김동규;김보철;정용현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.6
    • /
    • pp.695-701
    • /
    • 1998
  • Researches on unused energy are being continued because of the limited fossil fuel and the destruction of environment. Therefore this study was peformed as follows. The collectable amount of exhausted heat for an air-conditioning was calculated by the subway thermal environment prediction program. And the electric power needed by conventional heat source equipments was compared with one by unused heat source equipments when the exhausted heat was used by heat pump in heating and hot water supplying. The results are summarized as follows; 1) Forced ventilation should be conducted to keep optimal temperature in subway tunnel in summer as well as in winter. According to the simulation, temperature in tunnel was higher than that on the ground in summer when the forced ventilation was conducted only in winter. 2) Ventilating time should be calculated out to the optimal condition for not only saving power of ventilation fan but reusing exhausted heat. By the simulation, it is certain that the exhausted heat should be eliminated in air-conditioning time. 3) The use of exhausted heat source heat pump could save 8% of electric power per hour in comparison with existing heat pump. It was based on a present heat generation and traffic for ventilating time of general air-conditioning, but could be different by ventilating time. 4) As the traffic increases up to 1.5 or 2 times, electric power consumption of the conventional heat pump increases to 11% or 13.5% per mean hour in comparison with that of the exhausted heat source heat pump, though all-day ventilation.

  • PDF

Analysis of 2006 Summer Peak Network Operation (06년 하계피크시 전력계통 운영실적 분석)

  • Joo, Joon-Young;Bae, Joo-Chun
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.314-316
    • /
    • 2006
  • 06년 하절기 최대부하시 EMS SE를 통한 최대부하 계통을 취득하여 PSS/E file로 변환하여 발전기 및 송변전선비 등 실제계통의 운전상황을 확보하였다. 이를 토대로 '06년도 하절기 실계통 전력계통의 특성을 도출하고, 조류계산 및 안정도 검토 등을 통해 금년 상반기에 수립된 하계운영방안의 적정성을 평가해 보았다. 이러한 분석을 통해 계획단계의 최적화된 방안도출을 도모하고 분석내용은 향후 전력계통 안정운영을 위한 자료로 활용할 수 있을 것이다.

  • PDF

Residential Solar Cell System by driving of High Efficiency Inverter

  • Kwak Dong-Kurl;Lee Hyun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.687-691
    • /
    • 2001
  • With today's global environmental and energy problems, high expectations exist for solar power generation to reduce carbon dioxide generated by the consumption of fossil fuels. On the other hand, power consumption in residential homes is increasing every year. Among the many household appliances, the power demand for air conditioners increases dramatically during the summer, particularly in the afternoons. As this pattern closely matches the output pattern of solar cells, it should be possible to combine a photovoltaic array with an air conditioner to decrease the energy consumption within the home. We have developed a residential solar-powered air conditioner that operates through a combination of photovoltaic array and commercial power. In this paper, the configuration and specification of the residential solar-powered system are described to a novel high efficiency inverter using a ZVCS boost converter. And the performance evaluations of the solar-powered air conditioner are examined by the analysis of a new tracking controller with a maximum power $P_{max}$ detection of solar cell.

  • PDF

Technical Trend of Receiver for Solar Power Tower (타워용 태양열발전 시스템 흡수기 기술동향)

  • Kim, Jong-Kyu;Kim, Jin-Soo;Lee, Sang-Nam;Kang, Yong-Heack
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.161-164
    • /
    • 2008
  • For the development of solar thermal power tower plant from the early 80' to today, various kinds of receiver have been tested and evaluated. Most of 1st generation receiver used water/steam as a working fluid to operate steam turbine and now the first commercial solar power tower PS-10 also makes saturated steam. However, to increase thermal efficiency of storage system and to obtain practical use of solar energy, molten salt system have been used from THEMIS project in France at 1984. The Solar Tres plant of 17 MWe power generation will be constructed in Spain and have plan to operate 24 hours in summer. The air volumetric receiver system can be integrated with combined cycle of gas turbine and HRSG and also with steam turbine easily. Therefore, related researches to develop higher efficient solar power tower plant and to operate with stable are widely performed in the world.

  • PDF

Preventive Control Algorithm Using Sensitivity Analysis in Voltage Stability Assessment. (감도 해석을 통한 전압안정도 예방제어 알고리듬 개발)

  • Han, Sang-Wook;Seo, Sang-Soo;Lee, Byong-Jun;Jang, Kyung-Chul;Kim, Tae-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.483-485
    • /
    • 2005
  • In 2003, there was a wide-area blackout in the United States and Canada. More than fifty million people underwent power failure and the estimated financial loss was about four billion dollars. By such wide-area blackouts, the interest in voltage stability has increased gradually. In order to maintain the voltage stability, the preventive control is essential for a contingency. In this paper, a proper preventive control is determined for defined severe contingencies. Among the preventive control methods (generation rescheduling, load curtailment, tap adjusting, injecting the shunt capacitor, and so on.), this paper presents the injection of shunt capacitors by the sensitivity analysis of the voltage stability assessment for preventive controls. The 2006-2010 KEPCO summer peak system is used in case studies.

  • PDF

The Challenges and Countermeasures of Korea Power System at 2015 Summer Peak Load (2015년 하계 최대부하시 우리나라 전력계통의 문제점 및 대책 방안)

  • Song, Tae Yong;Joo, Joon Young;Lee, Chang Gun;Kim, Sang Min;Hur, Sung Il
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.333-334
    • /
    • 2015
  • 2015년 발,송,배전 설비 신설, 변경과 최대부하82,000MW에 대비하여 우리나라 전력계통의 운영방안을 검토하였다. 고장전류를 차단기 정격 내에 유지할 수 있도록 모선분리, 선로분리 등을 적용하였고, 특히 765kV 송전선로 고장시 계통안정을 위해 수도권의 부하를 차단하는 장치를 정지하는 방안을 마련하여 수도권 계통안정에 기여하였다. 인천지역에서 나타난 과전압 및 안정도 약화에 대해 적절한 발전및 송전제약 한계값을 적용하여 인천지역의 안정 운영에도 기여하였다.

  • PDF

A study on the energy saving with load characteristic pattern analysis in Electric railway system (전기철도의 부하특성별 패턴 분석을 통한 에너지 절감방안 연구)

  • Jeon, Yong-Joo;Lee, You-Kyung;Lee, Sung-Uk
    • Proceedings of the KIEE Conference
    • /
    • 2006.07b
    • /
    • pp.1079-1080
    • /
    • 2006
  • This paper presents the methods to save energy by using load consumption pattern analysis. Base on the substation annual power usage data, the characteristic of the substation power consumption have investigated. With this investigation effective electrical billing condition and the control target load has been determined. Most of power usage comes from the motor car, so power system and load table of motor car were reviewed. And in the metropolitan area the peak power consumption occurs at summer or winter rush hours because of its typical characteristics. From this data control point of time are determined. Through the whole study the methode to control the power Peak consumption are proposed and prototype was designed.

  • PDF

Power-factor improvement of residential solar air-conditioner power system (가정용 태양광 에어컨 전원시스템의 역률 개선)

  • Park, Y.J.;Mun, S.P.;Park, J.W.;Suh, K.Y.;Kim, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.6-8
    • /
    • 2002
  • Generally in solar air conditioning system, the diode rectifier is used to build up DC link voltage from AC source. The diode rectifier is simple and cheap but it brings out the problems of low power factor and plentiful harmonics at the AC source. Also It can degrade the utilization rate of solar energy because the reverse of power flow cannot be made. Hence, in this paper to overcome the peak power problems in summer and to endure good AC input characteristics, solar air conditioning system using the PWM converter is proposed. A high input power factor of 97[%] and an efficiency of 98[%] are also obtained. The harmonic guide lines of proposed rectifier is no interfered with inverter switching, resulting in a simple, reliable and low cost ac to dc converters in comparison with the boost type current improving circuits.

  • PDF

Direct Load Control System for Air-conditioner (에어컨부하 직접 제어시스템 실용화 연구)

  • Ko, Sang-Cheon;Lee, Sang-Yun;Kim, Myong-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1999.07g
    • /
    • pp.3051-3053
    • /
    • 1999
  • In recent years, it becomes a worldwide trend that the power utilities focus their attention to Demand Side Management. Increasing Electric power consumption, they adopt a direct load management to accomplish low cost and stability of electric supply. Following this trend, KEPCO is researching a Direct Load Control System for Air Conditioner. This Paper presents the development results of the Direct Load Control System to Control electric power consumption of Conditioner in summer period this year.

  • PDF