• Title/Summary/Keyword: Sulfur poisoning

Search Result 38, Processing Time 0.047 seconds

The performance of PEMFC during exposure to simultaneous sulfur impurity poisoning on cathode and anode (공기극과 연료극의 복합 황불순물에 의한 고분자 전해질막 연료전지의 성능에 미치는 영향)

  • Lee, Soo;Jin, Seok-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.4
    • /
    • pp.594-598
    • /
    • 2012
  • Polymer electrolyte membrane fuel cell(PEMFC) performance degrades seriously when sulfur dioxide and hydrogen sulfide are contaminated in the fuel gas at anode and air source at cathode, respectively. This paper reveals the effect of the combined sulfur impurity poisoning on both PEMFC cathode and anode parts through measuring electrical performance on single FC operated under 1 ppm to 10 ppm impurity gases. The severity of $SO_2$ and $H_2S$ poisoning depended on concentrations of impurity gases under optimum operating conditions($65^{\circ}C$ of cell temperature and 100 % relative humidity). Sulfur adsorption occured on the surface of Pt catalyst layer on MEA. In addition, MEA poisoning by impurity gases were cumulative. After four consecutive poisonings with 1, 3, 5 to 10 ppm, the fuel cell performance of PEMFC was decrease upto 0.54 V(76 %) from 0.71 V.

Sulfur Poisoning of Ni Anode as a Function of Operating Conditions in Solid Oxide Fuel Cells (고체산화물 연료전지의 운전 조건에 따른 니켈 전극 황 피독 현상)

  • Lee, Ho Seong;Lee, Hyun Mi;Lim, Hyung-Tae
    • Korean Journal of Metals and Materials
    • /
    • v.56 no.12
    • /
    • pp.893-899
    • /
    • 2018
  • In the present study, we investigated the sulfur poisoning of the Ni anode in solid oxide fuel cells (SOFCs) as a function of operating conditions. Anode supported cells were fabricated, and sulfur poising tests were conducted as a function of current density, $H_2S$ concentration and humidity in the anode gas. The voltage drop was significant under the higher current density (${\sim}714mA/cm^2$) condition, while it was much reduced under the lower current density (${\sim}389mA/cm^2$) condition, at 100 ppm of $H_2S$. A secondary voltage drop, which occurred only at the high current density, was attributed to Ni oxidation in the anode. Thus, operation at high current density with high $H_2S$ concentration may lead to permanent deterioration in the anode. The effect of water content (10%) on the sulfur poisoning was also investigated through a constant current test (${\sim}500mA/cm^2$) at 10 ppm of $H_2S$. The cell operating with 10% wet anode gas showed a much smaller initial voltage drop, in comparison with a dry anode gas. The present study indicates that operating conditions, such as gas humidity and current density, should be carefully taken into account, especially when fuel cells are operated with $H_2S$ containing fuel.

The Performance Degradation of PEMFCs Fabricated with Different GDLs During Exposure to Simultaneous Sulfur Impurity Poisoning Condition (서로 다른 GDL을 이용한 고분자전해질 막 연료전지의 황불순물 복합피독에 의한 성능 저하)

  • Lee, Soo;Kim, Jae-Hyun;Jin, Seok-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.30 no.1
    • /
    • pp.146-151
    • /
    • 2013
  • This paper reveals the performance decrease and recovery of PEMFC when the contaminated fuel gas and air source with sulfur impurities such as hydrogen sulfide and sulfur dioxide were simultaneously introduced to anode and cathode, respectively. Three different GDLs were fabricated with different carbon black and activated carbon to prevent an introduction of sulfur compound impurities into MEA. components. The severity of $SO_2$ and $H_2S$ poisoning was depended on concentrations(3 ppm - 10 ppm) of sulfur impurities. Especially, cell performance degradation rate was rapid when MEA fabricated with CN-2 GDL because it had little porosity on GDL surface. Moreover, the cell performance can be recovered up to 90%-95% only with neat hydrogen and fresh air feeding.. Conclusively, MEA fabricated with porous CN-1 GDL showed the best cell performance and recovery efficiency during exposure to poisoning condition by simultaneous sulfur impurities.

The Effect of Simultaneous Application with Biodiesel and ULSD on Exhaust Emissions and DOC (배출가스 및 DOC에 대한 바이오디젤과 ULSD의 동시 적용효과)

  • 박만재;백두성
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.2
    • /
    • pp.62-68
    • /
    • 2004
  • To comply with stringent exhaust emission standards, it is necessary to reserch on some better quality of automotive fuels. Sulfur in fuels is sulfur compound by DOC and then it caused to the increase of PM on the surface of the catalyst. This research is focused on diesel emission characteristics and poisoning effect on Diesel Oxidation Catalyst when Ultra Low Sulfur Diesel(ULSD) and biodiesel are applied simultaneously. The biodiesel is used to improve viscosity of fuel specially in fuel injection system of engine since the introduction of ULSD may degrade viscosity in the process of desulfurization. Furthermore, this study may provide some basic data for the design of emissions reduction technology.

A study of NOx performance for Cu-chabazite SCR catalysts by Sulfur poisoning and desulfation (Cu-Chabazite SCR Catalysts의 황 피독 및 탈황에 의한 NOx 저감 성능에 관한 연구)

  • Nam, Jeong-Gil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.8
    • /
    • pp.855-861
    • /
    • 2013
  • Small-pore Cu-chabazite SCR catalysts with high NOx conversion at low temperatures are of interest for marine diesel engines with exhaust temperatures in the range of 150 to $300^{\circ}C$. Unfortunately, fuels for marine diesel engines can contain a high level of sulfur of up to 1.5% by volume, which corresponds to a $SO_2$ level of 500 ppm in the exhaust gases for an engine operating with an A/F ratio of 50:1. This high level of $SO_2$ in the exhaust may have detrimental effects on the NOx performance of the Cu-chabazite SCR catalysts. In the present study, a bench-flow reactor is used to investigate the effects of sulfur poisoning on the NOx performance of Cu-chabazite SCR catalysts. The SCR catalysts were exposed to simulated diesel exhaust gas stream consisted of 500 ppm $SO_2$, 5% $CO_2$, 14% $O_2$, 5% $H_2O$ with $N_2$ as the balance gas at 150, 200, 250 and $300^{\circ}C$ for 2 hours at a GHSV of 30,000 $h^{-1}$. After sulfur poisoning the low-temperature NOx performance of the SCR catalyst is evaluated over a temperature range of 150-$300^{\circ}C$ to determine the extent of the catalyst deactivation. Desulfation is also carried out at 600 and $700^{\circ}C$ for 30 minutes to determine whether it is possible to recover the NOx performance of the sulfur-poisoned SCR Catalysts.

A Study on the Exhaust Emissions Characteristics of LPG Vehicle using LPG Fuel with Sulfur Free Odorant (비황분계 부취제를 혼합한 LPG 연료의 차량 배출가스 특성에 관한 연구)

  • Kim, Jae-Kon;Lee, Ho-Kil;Yim, Eui Soon;Jung, Choong-Sub
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.6
    • /
    • pp.545-554
    • /
    • 2014
  • In general, odorant was added to fuel gases, such as LPG, LNG and city gas, to prevent gas poisoning, ignition, explosion, or other accident caused by fuel gases, and to enable immediate and easy detection of fuel-gas leakage by emitting an offensive smell. This study describes a study on the exhaust emissions characteristics and fuel economy of liquefied petroleum gas (LPG) vehicle using LPG fuel with new sulfur free odorant. New sulfur free odorant was added to LPG to reduce sulfur content of the LPG. Its performance and exhaust emission were compared to those of LPG with sulfur containing odorant (EM, ethyl mercaptan). Engine performance using LPG with sulfur free odorant was similar to that with sulfur-containing odorant. Exhaust emissions from the LPG vehicle with LPG including sulfur free odorant were also similar to those with LPG including sulfur containing odorant in the FTP 75 and NEDC mode. There experimental results suggest that the sulfur free odorant may substitute for the sulfur containing odorant in LPG fuel.

Single Cell Performance Recovery of $SO_2$ Poisioned PEMFC using Cyclic Voltametry (순환전류 전압법을 이용한 이산화황 피독 PEMFC 단위전지의 성능 회복)

  • Lee, Soo;Jin, Seok-Hwan
    • Journal of the Korean Applied Science and Technology
    • /
    • v.28 no.4
    • /
    • pp.497-501
    • /
    • 2011
  • Polymer electrolyte membrane fuel cell (PEMFC) performance degrade when sulfur dioxide is present in the fuel hydrogen gas, this is referred as $SO_2$ poisoning. This paper reveals $SO_2$ poisoning on PEMFC cathode part by measuring electrical performance of single cell under 1 ppm and 5 ppm on $SO_2$ gas operating. The security of $SO_2$ poisoning depended on $SO_2$ concentration under the best operating conditions($65^{\circ}C$ of cell temperature and 100% of relative humidity between anode and cathode). $SO_2$ adsorption occured on the surface of catalyst layer on membrane electrode assembly (MEA), In addition, MEA poisoning by $SO_2$ was cumulative but reversible. After poisoning within 5 ppm $SO_2$ for 1hr, the electrical performance of PEMFC was found to recover up to about 93% by cyclic voltametry scan.

Emission Characteristics in The Application of ULSD, Biodiesel and DOC in Heavy Duty Diesel Engine (대형 디젤기관에서 초저유황경유, 바이오디젤 및 디젤산화촉매 적용시의 배기가스 특성)

  • Baik, Doo-Sung;Park, Man-Jae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.1
    • /
    • pp.52-58
    • /
    • 2004
  • To develop a low emission engine, it is necessary to obtain some better quality of automotive fuels. Sulfur in fuel is transformed to sulfate-laden PM as DOC is applied. Therefore, it necessary to provide low sulfur fuels before DOC is applied. According to the specification of test fuels, flash point, distillation 90%, cetane index are improved but viscosity is decreased in the process of desulfurization. Excessively reduced sulfur may cause to decrease lubricity of fuel and engine performance in fuel injection system. Therefore, this research was emphasized how the application of Bio-diesel affects on the emission characteristics and engine performance under the circumstance of ULSD and DOC.

Effect of Sulfur Dioxide on Crops - Physiology of Lesion, Yield Loss, and Preventive Measures (아황산(亞黃酸)가스에 의(依)한 농작물(農作物)의 피해생리(被害生理) 감수율(減收率) 및 피해경감(被害輕減)에 관(關)한 연구(硏究))

  • Han, Ki-Hak
    • Applied Biological Chemistry
    • /
    • v.16 no.3
    • /
    • pp.146-165
    • /
    • 1973
  • Crop damages caused by sulfur dioxide poisoning were studied with respect to physiology of lesion, yield loss and prevention measures. The results are summarized as follows; 1. On the physiology of injury: The sulfur dioxide gas did no: affect the pH and $E_h$ values of the tested leaf juice of plants. Peroxidase activity was inhibited just after sulfur dioxide treatment but gradually recovered to normal after 10 hours. Methanolic chlorophyll solution was instantaneously and irreversibly bleached by the addition of sulfur dioxide gas with no evidence of pheophytin formation. It seems that chlorophyll forms colourless addition product or is reduced to colourless form with either sulfur dioxide gas or sulfurous acid. Chlorophyll in the chloroplast was also bleached by the sulfur dioxide treatment, as in the case of methanolic solution of chlorophyll, except that the rate of bleaching was rather slow, requiring 1-2 hours. It appears that the most inflicting cause of sulfur dioxide gas to plants may be the destruction of chlorophyll by the poisoning gas. 2. On the effects to crop yield: The crop yield losses were proportional to the concentration of inflicting sulfur dioxide gas. The order of tolerence of the crops to the sulfur dioxide gas was as follows - chinese cabbage being the most susceptible; wheat, paddy rice, barley, soybean, welsh onion, radish and chinese cabbage. The crucifer crops were generally found more susceptible than other crops studied. With respect to the growing stages of crops exposed to sulfur dioxide gas, it was found that the flowering stage was the most susceptible fellowed by panicle forming, milky and tillering in the decreasing order of susceptibility. 3. On the preventive measures of yield losses: Soil applications of potassium, wollastonite, lime or spray of lime water were effective to prevent yield losses from sulfur dioxide fumigation of paddy rice, barley, and soybeans. The most responsive treatment was lime water spray for all crops tested. In case of sulfur dioxide fumigated paddy rice, the lime water spray also increased carbon assimilation.

  • PDF

Successful treatment by exchange transfusion of a young infant with sodium nitroprusside poisoning

  • Baek, Jong-Geun;Jeong, Hoar-Lim;Park, Ji-Sook;Seo, Ji-Hyun;Park, Eun-Sil;Lim, Jae-Young;Park, Chan-Hoo;Woo, Hyang-Ok;Youn, Hee-Shang;Yeom, Jung-Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.53 no.8
    • /
    • pp.805-808
    • /
    • 2010
  • Although sodium nitroprusside (SNP) is often used in pediatric intensive care units, cyanide toxicity can occur after SNP treatment. To treat SNP-induced cyanide poisoning, antidotes such as amyl nitrite, sodium nitrite, sodium thiosulfate, and hydroxycobalamin should be administered immediately after diagnosis. Here, we report the first case of a very young infant whose SNP-induced cyanide poisoning was successfully treated by exchange transfusion. The success of this alternative method may be related to the fact that exchange transfusion not only removes the cyanide from the blood but also activates detoxification systems by supplying sulfur-rich plasma. Moreover, exchange transfusion replaces cyanide-contaminated erythrocytes with fresh erythrocytes, thereby improving the blood's oxygen carrying capacity more rapidly than antidote therapy. Therefore, we believe that exchange transfusion might be an effective therapeutic modality for critical cases of cyanide poisoning.