• Title/Summary/Keyword: Sulfur Hexafluoride ($SF_6$)

Search Result 48, Processing Time 0.024 seconds

Atmospheric Sulfur Hexafluoride $(SF_6)$ near the Kwanak Mountain, Seoul (서울 관악산 대기 중의 $SF_6$에 관한 연구)

  • Lee, Junghyun;Kim, Kyung-Ryul
    • Atmosphere
    • /
    • v.18 no.3
    • /
    • pp.225-235
    • /
    • 2008
  • Sulfur hexafluoride ($SF_6$), man-made compound, has been paid attention as a potent greenhouse gas. After Kyoto Pototcol on Climate Change in 1997, nations established the policy aimed at minimizing release of $SF_6$ to atmosphere. We have developed and operated an automatic analytical system for monitoring atmospheric $SF_6$ using gas chromatography with electron capture detector (GC-ECD) and packed separate-column. Here, we report and discuss 4-month record of atmospheric $SF_6$ concentrations monitored at Seoul National University (SNU) pilot station near the Kwanak Mountain, Seoul. Most of observed $SF_6$ concentrations were excessively high compared with Northern Hemisphere (NH) background trend obtained from National Oceanic and Atmospheric Administration (NOAA) Earth System Research Laboratory (ESRL) monitoring stations. And the observed $SF_6$ showed extremely wide variability ranging from 4.6 pptv to $1.1{\times}10^3$ pptv, which may be affected by local sources placed nearby. Simultaneous wind data with $SF_6$ measurements show that relatively high values of $SF_6$ correspond to weak wind as well as southerly. There are many engineering installations to the south of the station. The regional value of the atmospheric $SF_6$ estimated from the data selection by wind conditions is about 6.8 pptv. This value, which is similar to concentrations of urban areas, is higher than NH background concentration.

Improved sulfur hexafluoride(SF6) gas analysis method for quality management of cryogenic refinement system (극저온 정제시스템의 품질관리를 위한 SF6 가스 분석방법 개선)

  • Lee, Jeong Eun;Cho, Min-ho;Lee, Won Seok
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.8 no.1
    • /
    • pp.37-41
    • /
    • 2022
  • Because sulfur hexafluoride(SF6) is classified as one of the six major greenhouse gases, SF6 handling in power plant such as recovery, purification, and reuse is considered to be important. KEPCO has focused to develop the advanced recovery and purification technology of SF6 reuse. SF6 analysis includes the on-site analyses and on-line analyzer; i.e., (1) on-site analysis has an error rate of ±0.5% and (2) on-line analysis has an error rate of ±0.1%, which is possible to adjust operating conditions and to make the work more conveniently by analyzing SF6 concentration before and after purification step. This paper presents an online analysis method in the SF6 purification and reuse system. In addition, the analysis results and quality guarantees for each section of the analysis system were presented.

A Study on Destruction Potential of Sulfur Hexafluoride (SF6) Using High Ionization Energy (고이온화에너지를 이용한 육불화황 (SF6) 분해가능성 연구)

  • Ryu, Jae-Yong;Kim, Jong-Bum;Choi, Chang-Yong;Lee, Sang-Joon;Kwak, Hee-Sung;Yun, Young-Min
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.28 no.4
    • /
    • pp.446-453
    • /
    • 2012
  • Destruction and removal efficiency (DRE) of $SF_6$ was tested with varying degrees of ionization and initial concentrations of $SF_6$. The applied dose of ionization energy varied from 0 to 400 kGy. The initial concentration of $SF_6$ gas also varied from 1,000 ppm to 2,500 ppm. In order to assess the effect of a residence time on DRE (Destruction and Removal Efficiency, %), experiments were also conducted at different irradiation times of 3, 5, 10, 15, and 20 sec, respectively. The DRE of $SF_6$ increased with an increasing amount of dose and current. Regardless of initial concentration of $SF_6$, 90% level of DRE was achieved by applying over 10 mA of electrical current.

Experimental Study on the Interference of Water Vapor on the Chemical Ionization of OH by Sulfur Hexafluoride Ion

  • Park, Jong-Ho
    • Mass Spectrometry Letters
    • /
    • v.5 no.4
    • /
    • pp.120-123
    • /
    • 2014
  • The interference of water vapor on the chemical ionization (CI) of hydroxyl radicals (OH) by sulfur hexafluoride ion ($SF_6{^-}$) was investigated using a flow tube system coupled to a high-pressure CI mass spectrometer. Water vapor, which is required to study heterogeneous reactions of OH under real tropospheric conditions, transforms the reagent ion $SF_6{^-}$ into $SF_4O^-$ and $F^-(HF)_n$, resulting in a substantial loss in CI sensitivity. Therefore, under humid conditions, peaks corresponding to OH are drastically diminished, while those corresponding to OH-water complex ions ($[OH(H_2O)_n]^-$) are enhanced. $[OH(H_2O)_3]^-$ was observed as the major OH species. The obsercation of $[OH(H_2O)_n]^-$ by isolating humid conditions to the CI region and preliminary ab initio calculations suggested that $[OH(H_2O)_n]^-$ ions were produced from reactions between OH ions ($OH^-$) and water molecules. An additional helium buffer flow introduced into the CI region reduced loss of the reagent ion and resulted in a partial recovery of OH peak intensities under humid conditions.

A Study on Increase of Sulfur Hexafluoride(SF6) Destruction and Removal Efficiency by Conditioning Agent(H2) (수소첨가에 의한 육불화황(SF6) 분해효율 향상 기초연구)

  • Ryu, Jae-Yong;Kim, Jong-Bum;Choi, Chang-Yong;Jang, Seong-Ho;Lee, Sang-Joon
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1163-1169
    • /
    • 2012
  • Destruction and removal efficiency (DRE) of $SF_6$ was tested with low degrees of ionization. The applied dose of ionization energy varied from 63.70 to 212.34 kGy. The initial concentration and flow rate of $SF_6$ gas were 1,000 ppm and 50L/min, respectively. In order to increase the DRE, injection of conditioning agent ($H_2$) were conducted. The DRE of $SF_6$ increased about 2 times with injection of $H_2$ gas.

Study on the Separation of N2/SF6 Mixture Gas Using Polyimide Hollow Fiber Membrane (폴리이미드 중공사 막을 이용한 N2/SF6 혼합기체 분리에 관한 연구)

  • Kim, Dae-Hoon;Kim, Guang-Lim;Jo, Hang-Dae;Park, Jong-Soo;Lee, Hyung-Keun
    • Korean Chemical Engineering Research
    • /
    • v.48 no.5
    • /
    • pp.660-667
    • /
    • 2010
  • In this research polyimide, Matrimid 5218, hollow fiber membrane was used to recover sulfur hexafluoride($SF_6$) which is one of the six greenhouse gases from $N_2/SF_6$ mixture gas. Fibers were spun from using dry-wet phase inversion method. The module was manufactured by fabricating fibers after surface coating with silicone elastomer. The scanning electron microscopy(SEM) studies showed that the produced fibers typically had an asymmetric structure; a dense top layer supported by a sponge-like substructure. The developed module had a permeance of 0.78-1.36 GPU for $N_2$ with $N_2/SF_6$ selectivity of 2.44-5.08 at various pressure and temperature. For recovery of $SF_6$, a membrane module and 10 vol.% $SF_6$ from $N_2/SF_6$ mixture gas was used. The effects of various operating condition such as pressure, temperature, and retentate side flow rate were tested. When pressure and temperature were increased and retentate flow rate was decreased, the $SF_6$ purity in recovered gas was increased up to 37.5 vol.% with decreasing recovery ratio. When retentate flow rate was increased pressure and temperature was decreased, the $SF_6$ recovery ratio in retentate side was increased up to 89% with decreasing the $SF_6$ purity in retentate side.

$SF_6$ Emission Characteristics at High Voltage Equipments in use-phase Stage (고압 전력기기에서의 $SF_6$ Gas 사용단계별 배출특성에 관한 연구)

  • Park, Jung-Ju;Cha, Yeun-Haeng
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2199-2201
    • /
    • 2008
  • Sulfur hexafluoride($SF_6$) is a gaseous dielectric used in high voltage electrical equipment such as an insultor or arc quenching medium in the transmission and distribution of electricity. however, $SF_6$ is one of the greenhouse gases(GHG) with a global warming potential that is 23,900 times greater than that of carbon dioxide($CO_2$). for this reason, $SF_6$ emissions in electric equipment shall be controlled to reduce GHG and improve cost-effective use of $SF_6$ for economical benefits. Until recently there has not been any investigation on $SF_6$ emission characteristics and inventory in Korea. To understand emission characteristics during the use-phase, the scope of this study was limited to the following closed pressure system equipment from 10 substations in Korea. This study highlights (1) the investigation of sampling/analysis methodology for $SF_6$ emissions in high voltage equipment, (2) the estimation of $SF_6$ emissions in the use-phase, and (3) the comparison between the emission ratio and the mass-balance applied to inventory study. According to this study, the majority of emissions were related to electric equipment nameplates and the rest of the emissions were related to the handling of $SF_6$ during operations. from this result, emission ratios estimated from this study were similar; GIS was 14% and GCB was 13%, as maintenance process conditions were the same as manual process conditions for both equipment.

Morphological study of $SF_6$ clathrate hydrate crystal ($SF_6$ 하이드레이트 결정 성장의 특성)

  • Lee, Yoon-Seok;Lee, Hyun-Ju;Lee, Eun-Kyung;Kim, Soo-Min;Lee, Ju-Dong;Kim, Yang-Do
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.711-711
    • /
    • 2009
  • Global warming has been widely recognized as a serious problem threatening the future of human beings. It is caused by the buildup in the atmosphere of greenhouse gases, such as carbon dioxide, methane, hydrofluorocarbons (HFCs), and sulfur hexafluoride (SF6). Particularly, SF6 has extremely high global warming potential compare to those of other global warming gases. One option for mitigating this greenhouse gas is the development of an effective process for capturing and separating these gases from anthropogenic sources. In general, gas hydrates can be formed under high pressure and low temperature. However, SF6 gas is known to form hydrate under relatively milder conditions. Therefore, technological and economical effects could be expected for the separation of SF6 gas from waste gas mixtures. In this study, we carried out morphological study for the SF6 hydrate crystals to understand its formation and growth mechanisms. The observations were made in high-pressure optical cell charged with liquid water and SF6 gas at constant pressure and temperature. Initially SF6 hydrate formed at the surface between gas and liquid regions, and then subsequent dendrite crystals grew at the wall above the gas/water interface. The visual observations of crystal nucleation, migration, growth and interference were reported. The detailed growth characteristics of SF6 hydrate crystals were discussed in this study.

  • PDF

A Study of $SF_6$ Treatment using Principles of Gas Hydrate Formation (가스 하이드레이트 형성 원리를 이용한 $SF_6$ 처리 기술에 관한 연구)

  • Lee, Bo-Ram;Lee, Hyun-Ju;Kim, Yang-Do;Ryu, Young-Bok;Lee, Man-Sik;Kim, Young-Seok;Lee, Ju-Dong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.485-488
    • /
    • 2007
  • $SF_6$(sulfur hexafluoride)는 뛰어난 단열 및 아크방지능력(arc-extinguishingproperty)으로 인해, 전력용 변압기의 절연가스와 반도체${\cdot}$액정용 플라즈마 CVD로의 cleaning gas, 주물공장 covering gas 등으로 사용되고 있다. 하지만, $SF_6$의 지구온난화지수(global warming potential)는 $CO_2$대비 23,900배가 높아 기후변화에 미치는 영향이 $CO_2$보다 훨씬 크고, 대기 중 분해되지 않고 잔존하는 기간이 $CH_4$ 10년, $CO_2$ 및 CFCs는 100년으로 추정되는데 반해, $SF_6$는 3,200년으로 연간방출양이 작더라도 오랜 기간 누적되면 그 파장이 클 것으로 사료된다. 대부분의 가스 하이드레이트(고상결정상태)는 고압, 저온에서 형성가능 하지만, 불화가스에 대해서는 쉽게 결정화가 일어난다. $SF_6$는 3$^{\circ}C$, 2기압에서 고밀도 고상화가 되기 때문에 여러 기체와 흔합되어 있는 경우 $SF_6$만을 압축된 고상 결정상태를 형성, $SF_6$를 회수, 정제할 수 있으므로 불화가스 분리${\cdot}$회수에 기술적, 경제적 효과를 기대할 수 있다. 본 연구에서는 하이드레이트 촉진제로서 계면활성제(promoter) 첨가에 따른 $SF_6$ 하이드레이트 형성 및 해리과정 실험을 통해 효율적인 $SF_6$ 저감에 관한 적용기술을 연구해 보았다.

  • PDF

Measurement and Characterization of Atmospheric SF6 at Korea GAW Center in 2007 (기후변화감시센터의 대기 중 2007년 육불화황 측정 결과 및 특성)

  • Yoo, Hee-Jung;Kim, Jeong-Sik;Lee, Jeong-Soon;Moon, Dong-Min;Lee, Jin-Bok;Kim, Jong-Ho;Kim, Sang-Hoon;Lee, Il-Yong
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.27 no.1
    • /
    • pp.1-15
    • /
    • 2011
  • Korea Global Atmosphere Watch Center (KGAWC), which is located in Anmyeondo and, belongs to the Korea Meteorological Administration (KMA), measures sulfur hexafluoride ($SF_6$) in every hour since 2007. In this study, $SF_6$ observed in 2007 are discussed. A gas chromatograph-electron capture detector (GC-ECD) with pre-cooled device is applied during the observation, and produced data are qualified by means of periodic calibration with $SF_6$ standard gas made by Korea Research Institute of Standard and Science (KRISS). $SF_6$ has been greatly paid attention since Kyoto protocol because of its high global warming potential(GWP) with 22,200 times of $CO_2$ in the period of 100 years. It is a man-made compound and has been usually used for gas insulation since 1970s and for etching process in the information technology-based industry since 1990. Average mixing ratio of $SF_6$ in 2007 was 6.65 pmol/mol at Anmyeondo. According to the GAW report published in 2008, average mixing ratio of $SF_6$ in the atmosphere is continuously growing. At present, the average mixing ratio of $SF_6$ in the atmosphere is known to be approximately 6.25 pmol/mol at global observatory. $SF_6$ value in Anmyeondo shows 0.40 pmol/mol greater than that of the Mauna Loa observatory in 2007.