• Title/Summary/Keyword: Suitable compression ratio

Search Result 84, Processing Time 0.029 seconds

Cyclic test for beam-to-column abnormal joints in steel moment-resisting frames

  • Liu, Zu Q.;Xue, Jian Y.;Peng, Xiu N.;Gao, Liang
    • Steel and Composite Structures
    • /
    • v.18 no.5
    • /
    • pp.1177-1195
    • /
    • 2015
  • Six specimens are tested to investigate the cyclic behavior of beam-to-column abnormal joints in steel moment-resisting frames, which are designed according to the principle of strong-member and weak-panel zone. Key parameters include the axial compression ratio of column and the section depth ratio of beams. Experimental results indicate that four types of failure patterns occurred during the loading process. The $P-{\Delta}$ hysteretic loops are stable and plentiful, but have different changing tendency at the positive and negative direction in the later of loading process due to mechanical behaviors of specimens. The ultimate strength tends to increase with the decrease of the section depth ratio of beams, but it is not apparent relationship to the axial compression ratio of column, which is less than 0.5. The top panel zone has good deformation capacity and the shear rotation can reach to 0.04 rad. The top panel zone and the bottom panel zone don't work as a whole. Based on the experimental results, the equation for shear strength of the abnormal joint panel zone is established by considering the restriction of the bottom panel zone to the top panel zone, which is suitable for the abnormal joint of H-shaped or box column and beams with different depths.

Shear wave velocity of sands subject to large strain triaxial loading

  • Teachavorasinskun, Supot;Pongvithayapanu, Pulpong
    • Geomechanics and Engineering
    • /
    • v.11 no.5
    • /
    • pp.713-723
    • /
    • 2016
  • Shear wave velocities of three selected sandy soils subject to drained triaxial compression test were continuously measured using the bender elements. The shear wave velocity during isotropic compression, as widely recognized, increased as confining pressure increased and they were correlated well. However, during drained shearing, the mean effective stress could no further provide a suitable correlation. The shear wave velocity during this stage was almost constant with respect to the mean effective stress. The vertical stress was found to be more favorable at this stage (since confining stress was kept constant). When sample was attained its peak stress, the shear wave velocity reduced and deviated from the previously existed trend line. This was probably caused by the non-uniformity induced by the formation of shear band. Subsequently, void ratios computed based on external measurements could not provide reasonable fitting to the initial stage of post-peak shear wave velocity. At very large strain levels after shear band formation, the digital images revealed that sample may internally re-arrange itself to be in a more uniform loose stage. This final stage void ratio estimated based on the proposed correlation derived during pre-peak state was close to the value of the maximum void ratio.

Soil Characteristics of soft clay in Nakdong-River Basin by considering Sample Disturbance (시료교란 정도를 고려한 낙동강 하구 유역 점토의 토질역학적 특성)

  • 이경은;정두회
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2002.03a
    • /
    • pp.111-118
    • /
    • 2002
  • Recent study of soft clay of Nakdong-River basin has been taken correlation between soil properties by regression analysis without distribution whether the sample is disturbed or not, or treated as a whole area without proposing local correlation equation to Jang-U or Dae-Joe which has a specific locality. Accordingly, Those tendency cause the reliability of correlation between compression index and void ratio low and then design underestimate and uncertain eventually. In this study, Distributing the soft clay of Nakdong-River basin with failure strain of 6%, the suggestion by Skempton(1957), TakeNaka(1966)-the more sample is undisturbed, the more the ratio of E$\_$50/ and q$\_$u/, ${\alpha}$ = E$\_$50//(q$\_$u//2) = 1/$\varepsilon$$\_$50/ is high-is satisfied with the value of which ${\alpha}$ is 50 and It could be taken enough data in the condition of domestic. Besides other indices also make the distribution suitable. In conclusion, This study is supposed to propose the locally subdivided regression equation between compression index and void ratio considering the sample disturbance.

  • PDF

Compression Algorithm of HDTV Video Signals for VTR Recording (VTR 기록을 위한 HDTV 영상신호의 압축 알고리즘)

  • 조돈민;박동권;원치선;박진우;여지희;구형서;이종화
    • Journal of Broadcast Engineering
    • /
    • v.1 no.2
    • /
    • pp.108-117
    • /
    • 1996
  • In this paper we propose a Wavelet- based compression algorithm of HDTV video signals for the purpose of recording HDTV signals in the digital VTR. Comparing to the DCT- based compression method, which only yields unrecognizable DCT coefficients, the low frequency components of Wavelet coefficients maintain recognizable spatial domain information. So, it is more suitable for various VTR operations such as editing and multi-speed mode operations. Also, the adopted Wavelet filter can be Implemented with simple shift operations, which can reduce the computational complexities substantially. The quality of reconstructed HDTV signals with a 4:1 compression ratio turns out to be good enough for the studio use.

  • PDF

Communication-Power Overhead Reduction Method Using Template-Based Linear Approximation in Lightweight ECG Measurement Embedded Device (경량화된 심전도 측정 임베디드 장비에서 템플릿 기반 직선근사화를 이용한 통신오버헤드 감소 기법)

  • Lee, Seungmin;Park, Kil-Houm;Park, Daejin
    • IEMEK Journal of Embedded Systems and Applications
    • /
    • v.15 no.5
    • /
    • pp.205-214
    • /
    • 2020
  • With the recent development of hardware and software technology, interest in the development of wearable devices is increasing. In particular, wearable devices require algorithms suitable for low-power and low-capacity embedded devices. Among them, there is an increasing demand for a signal compression algorithm that reduces communication overhead, in order to increase the efficiency of storage and transmission of electrocardiogram (ECG) signals requiring long-time measurement. Because normal beats occupy most of the signal with similar shapes, a high rate of signal compression is possible if normal beats are represented by a template. In this paper, we propose an algorithm for determining the normal beat template using the template cluster and Pearson similarity. Also, the template is expressed effectively as a few vertices through linear approximation algorithm. In experiment of Datum 234 of MIT-BIH arrhythmia database (MIT-BIH ADB) provided by Physionet, a compression ratio was 33.44:1, and an average distribution of root mean square error (RMSE) was 1.55%.

Domain Searching method using DCT-coefficient for Fractal Image Compression (Fractal 압축방법을 위한 DCT 계수를 사용한 도메인 탐색 방법)

  • Suh, Ki-Bum;Chong, Jong-Wha
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.37 no.2
    • /
    • pp.28-38
    • /
    • 2000
  • This paper proposes a fractal compression method using the domain classification and local searching, which utilize DCT coefficient characteristic Generally, the fractal Image encoding method has a time consuming process to search a domain to be matched with range block In order to reduce computation complexity, the domain and range regions are respectively classified into 4 category by using the characteristics of DCT coefficients and each range region is encoded by a method suitable for the property of its category Since the bit amount of the compressed image depends on the number of range blocks, the matching of domain block and range block is induced on the large range block by using local search, so that compression ratio is increased by reducing the number of range block In the local search, the searching complexity is reduced by determining the direction and distance of searching using the characteristics of DCT coefficients The experimental results shows that the proposed algorithm have 1 dB higher PSNR and 0 806 higher compression ratio than previous algorithm.

  • PDF

Development of telePACS using world-wide-web and satellite data communication system (WWW 기반과 위성 데이터 통신을 이용한 원격 PACS의 개발)

  • 황선철;정태섭;김희중;이명호
    • Proceedings of the IEEK Conference
    • /
    • 1998.06a
    • /
    • pp.557-560
    • /
    • 1998
  • In this paper, we presetn the WWW (world-wide-web) base dtelePACS, which uses the communication network as asymmetric satellite data communication system (ASDCS). Web-based telePACS is imple-mented with JAVA language. Through the internet, web-based TelePACS can make it possible for remote hospital or doctor to access PACS data and information easily and cheaply. The ASDCS uses receive-only satellite links for data delivery and PSTN (Public switched telephone Network) modem or N-ISDN (narrow band integrate services digital network) for communication. The satellite communication linking shows the very high-seed performance such as 10-30 times faster than the modem linking.To solve the speed limits of internet, JPEG and wavelet compression methods were adapted in WWW-based TelePACS and were evaluated by PSNR (peak signal-to-noise ratio) and by radiological experts that 10:1 or less JPEG and wavelet compression may be acceptable for diagnostic purposes. Consequently, we get the conslusion that our system is suitable for tele-radiology and telemedicine world widely.

  • PDF

Performance Analysis and Prior-Treatment of Heat Pump System with Low-Temperature Water Heat Source (저온수열원이용 열펌프시스템의 전처리 및 성능분석)

  • Park, Seong-Ryong;Chang, Ki-Chang;Lee, Sang-Nam;Ra, Ho-Sang;Park, Jun-Tack
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.258-263
    • /
    • 2000
  • River water is higher in temperature than the surrounding environment during the winter. It is highly suitable a heat source for heat pump system. Despite its suitability, however, it is not widely used, due to its fouling and corrosive nature in heat exchanger tubes of evaporator. It is designed prior-treatment system which come into direct contact with the river water, such as auto-seamer, ozone generator for bactericidal test and auto-cleaning system. And it is analyzed treatment effects for its operation. It is designed two-stage compression heat pump system using R-134a with heating load 35.16kW, ad analyzed its performance. As a result it is obtained 3.08 COP when mid-point pressure is 1,200kPa, and bypass ratio of flowing refreigerant to high-stage compressor is 25.1%

  • PDF

Prediction of Stress-strain Behavior for Anisotropic Consolidated Compacted Decomposed Granite Soil (비등방 압밀된 다짐화강풍화토의 응력-변형률 거동 예측)

  • 정진섭;양재혁
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.2
    • /
    • pp.86-95
    • /
    • 2003
  • During this study, constant stress ratio tests with previous compression anisotropic stress history are performed on compacted decomposed granite soil sampled at Iksan, Jeonbuk. Yielding points are determined from stress-strain curves. The shape and characteristics of compression anisotropic yield curves is examined. In addition, the measured value of yielding curve and stress-strain behavior is predicted by Yasufuku's anisotropic constitutive model based on non-associated flow rule. The main results are summarized as follows : 1) Shape of yielding curves shows almost ellipse but asymmetry with respect to stress path during previous consolidation stress. 2) Yasufuku's anisotropic constitutive model is suitable in evaluation of yielding curves on anisotropic consolidated decomposed granite soil. 3) The predicted stress-strain curve shows reasonable agreement to measured behaviours.

Deformation Characteristics and Sealing Performance of Metallic O-rings for a Reactor Pressure Vessel

  • Shen, Mingxue;Peng, Xudong;Xie, Linjun;Meng, Xiangkai;Li, Xinggen
    • Nuclear Engineering and Technology
    • /
    • v.48 no.2
    • /
    • pp.533-544
    • /
    • 2016
  • This paper provides a reference to determine the seal performance of metallic O-rings for a reactor pressure vessel (RPV). A nonlinear elastic-plastic model of an O-ring was constructed by the finite element method to analyze its intrinsic properties. It is also validated by experiments on scaled samples. The effects of the compression ratio, the geometrical parameters of the O-ring, and the structure parameters of the groove on the flange are discussed in detail. The results showed that the numerical analysis of the O-ring agrees well with the experimental data, the compression ratio has an important role in the distribution and magnitude of contact stress, and a suitable gap between the sidewall and groove can improve the sealing capability of the O-ring. After the optimization of the sealing structure, some key parameters of the O-ring (i.e., compression ratio, cross-section diameter, wall thickness, sidewall gap) have been recommended for application in megakilowatt class nuclear power plants. Furthermore, air tightness and thermal cycling tests were performed to verify the rationality of the finite element method and to reliably evaluate the sealing performance of a RPV.