Experimental and computational studies were performed to investigate the effectiveness of a thrust vectoring method using a counterflow concept. A shadowgraph method was used to visualize the supersonic jet expanded from a two-dimensional convergent-divergent nozzle and deflected by a now suction. The primary nozzle pressure and suction nozzle pressure ratios are varied between 3.0 and 5.0, and between 0.2 and 1.0 respectively. The present experimental and computational results showed that, for a given primary nozzle pressure ratio, a decrease in the suction nozzle pressure ratio produced an increased thrust vector angle, and during the change processes of the suction pressure, a hysteresis effect of the thrust vectoring was found through the wall pressure distributions.
Purpose: The purpose of this study was to compare the difference of change in oxygen saturation, vital signs and suction time taken for the suctioning during endotracheal suctioning performed with closed suction system and with opened suction system. Methods: Data were collected from 31 adult patients with ventilator treatment who were admitted to a university hospital in Seoul and the collection period was from July 1 to November 15, 2005. Oxygen saturation, heart rate, respiration rate and mean arterial pressure were collected immediately prior to the suctioning intervention, during and 1 and 5 minutes after the suctioning from opened suction system and closed suction system. Results: 1) The difference in oxygen saturation was statistically significant in recovery time for oxygen saturation to return to baseline values after suctioning was significantly rapid on closed suction system (p<.05). 2) The difference in heart rate, respiration rate and mean arterial pressure was statistically insignificant 3) The suction time was shorter in closed suction system. Conclusion: Closed suction system is more efficient, as compared with the open suction system in the ventilator treatment.
본 연구에서는 해상(수상) 교량기초 시공 시 석션압으로 간편하게 설치될 수 있는 원형관 공법을 개발하고자, 실내 모형실험을 통하여 저수심 모래지반에 원형관 관입 시 설치 석션압을 평가하였다. 포화된 사질토의 반복실험을 위해 3개의 진동발생기를 활용한 진동다짐 토조 시스템을 구축하였고, 지반강도 확인을 위하여 소형 콘관입 장비를 활용하였다. 진동다짐 토조 시스템은 내부의 모래지반에 반복적으로 진동을 가하여 효율적으로 균질한 모래지반을 확보할 수 있었다. 다양한 지름과 두께를 가지는 원형관 모형체를 제작하고, 다양한 수심조건에 대하여 석션관입 실험을 수행하였다. 실험을 통한 석션압 분석결과 원형관의 관입깊이가 커짐에 따라 석션압은 커지고 지름이 클수록 원형관을 관입시키는데 필요한 석션압은 작아지는 것을 확인하였다. 특히, 수위가 낮을수록 석션관입을 위해 원형관 내부에서 끌어 올려야 하는 수두가 커지는 반면, 높아진 수두에 의한 물의 무게는 원형관의 전체 자중을 증가시켜 관입에 필요한 석션압은 작아짐을 알 수 있었다. 따라서, 저수심 조건에서 석션압을 이용하여 원형관을 설치할 경우 수심의 영향을 고려하여 설계 석션압을 결정해야 할 것으로 판단된다.
Suction Drain Method is soft ground improvement technique, in which a vacuum pressure can be directly applied to the Vertical Drain Board to promote consolidation and strengthening the soft ground. This method does not require a surcharge load, different to embankment or vertical drain method. In this study, Using Suction-CAIN program, which optimize th Suction Drain method, estimate validity Suction Drain method on deep soft ground
현재 불포화토에 대한 많은 연구가 진행되어 왔고 최근 들어 많은 연구자들이 불포화지반의 안정성을 보다 합리적으로 판단하고 해석하기 위해 불포화상태를 고려한 연구의 필요성을 제기하여 왔다. 이를 위해서는 흡인력에 대한 전단강도의 증진효과를 정량화하고 이를 안정해석에 적용하는 것이 요구되고 있는 실정이다. 따라서 본 연구에서는 불포화 사질토의 전단강도 특성을 규명하기 일해서 국내에 널리 분포하는 화강풍화토 7가지를 대상으로 불포화 삼축압축시험을 수행하였으며, 결과치를 분석하여 강도특성을 규명하고자 한다.
Since most soils exist above the ground water table, negative pore pressure exist in unsaturated soils. Negative pore water pressure in unsaturated soil affects the soil structure and degree of saturation and it is important for accurate evaluation of unsaturate flow and behavior. This negative pore pressure is called a matric suction which causes an increased shear strength. Therefore, it is required that the effect of increase in the shear strength should be included in a geotechnical analysis. From the test result, the influence of net confining pressure and matric suction on the shear strength was analyzed and strength parameter was increased with matric suction increase and a unliner relationship was found to relate matric suction and shear strength.
This paper dealt with numerical estimation of pressure pulsation of the refrigerant in a suction pipe of the compressor. To evaluate the effect of reduction of pressure pulsation, a pipe system with tube was simulated using F.S.I.(Fluid-structure interaction) analysis. A commercial program was used for calculating behavior of pressure. The numerical simulation for pressure ratio of before and after going though internal structure were carried out. As a result, it was verified that the pressure after passing structure is less than the pressure before passing internal structure depending on the longitudinal frequency of structure.
The purpose of this study was to identify effective methods to minimize increases in intracranial pressure(IICP ) during endotracheal suction by means of comparing two methods of hyperventilation and oxygen supply before and after endotracheal suction. In order to evaluate the effects of these two methods, the ICP during suctioning and the sustained time of IICP were measured. For hyperventilation, ambu-bagging was done 10 times for 30 seconds with a tidal volume of 800-900m1. For oxygen supply, 100 percent oxygen was supplied for 2 minutes before and after suction. The subjects for this study were 12 neurosurgical patients who had had a subarachnoid bolt inserted for ICP monitoring and they were all on mechanical ventilatory support in a surgical intensive care unit of Seoul National University Hospital from July 1, 1991 to March 31, 1992. In each patient hyperventilation was performed five times and oxygen supply was given five times and intracranial pressures were measured immediately before and every 30 seconds for 15 minutes after suction. For case assignments counterbalancing and repeated measure designs were combined. And so the total number of experiments were sixty for each group. The effects of hyperventilation and oxygen supply on the IICP and the sustained time of IICP after suction were analyzed by t-test. The results of study were as follows 1. There was a significant difference between the two groups in the increased ICP during suction (t=2.49, p=.014). 2. The sustained time of IICP after suctioning in the oxygen supply group was shorter than that in the hyperventilation group(t=2.35, p=.020) In summary, the Increase in the ICP during suction was lower and the time for the ICP to return to the presuction level was shorter in the oxygen supply group as compared to the hyperventilation group. Therefore, oxygen supply can be re commended before and after endotracheal suction.
It has been recognized unsaturated soil behaviour playing an important role in geomechanics. Up to now, only a few experimental data are available for the technical difficulties related to both volume changes and suction measurements. In this study, the volume changes of unsaturated compacted silty soil were monitored with proximeter (i.e. non-contactable transducer) during various triaxial compression tests, which gave a realistic estimation in the volume changes of unsaturated soil sample. The measurement of volume changes were performed with 0.5% of the maximum error under the axial strain ratio of less than 10%. The experimental results have revealed that the mechanical behaviour of unsaturated soil can be significantly affected by the matric suction. During the shearing processes, the level of maximum deviator stress under the initial suction pressure of 50kPa was higher than that under the initial suction pressure of 10kPa. On the other hand, the volume changes became smaller under the increase in the initial suction pressure.
In this study, an aspect of settlement, developed from different ground improvement method like suction drain method using vacuum pressure and vertical drain method using overburden pressure, was compared each other. In order to analyze settlement tendency of each method exactly, the finite element analysis program was used. The analyses of vertical settlement and lateral displacement for suction drain method and vertical drain method were conducted independently during the solving stage. The initial condition of drainage zone was fixed with 25m depth and 21m width. After the program analyses, the settlement condition had a different tendency with the ground improvement method. Especially, in the results of vertical drain method, the disparity of settlement between the middle of improved zone and unimproved zone. In the case of suction drain method, however, the difference of settlement was smaller than that of vertical drain method.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.