Development of the Dual Cyclone System for a High Efficient Vacuum Cleaner (사이클론 집진 원리를 적용한 진공청소기 개발에 관한 연구)

  • Lee, Jae-Keun;Lee, Jung-Eun;Kim, Seong-Chan;Cho, Min-Chul;Hyun, Choong-Nam;Kwack, Dong-Jin;Lim, Kyung-Suk;Lee, Sung-Hwa;Yang, Byung-Sun;Ji, Heon-Pyung;Jeong, Hoi-Kil;Park, Deog-Bae;Liu, Benjamin Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.644-649
    • /
    • 2000
  • A new cyclone system for the vacuum cleaner to collect dusts has been studied experimentally and numerically to meet the constant suction power, hygienic exhaust and a reduction of maintenance cost. The cyclone system of the vacuum cleaner consists of twin cyclones for improving dust collection efficiency. The first. cyclone catches large dust particles and the second one having two separated flows to decrease pressure drop collects small dust particles. The optimal design factors such as dust collection efficiency, pressure drop, and cut-size are investigated from the experimental results by the Taguchi method. Cyclone cleaner systems designed in this study has a good Performance taking into account the dust collection efficiency of 93% and the cut-size of $1.6{\mu}m$ in mass median diameter at the flow rate of 1 CMM. The cyclone vacuum cleaner showed the potential to be an effective method to collect dusts generated in the household.

  • PDF

Effect of Tip Gap Height on Heat/Mass Transfer over a Cavity Squealer Tip (팁간극높이가 전면스퀼러팁 표면의 열전달 특성에 미치는 영향)

  • Kang, Dong Bum;Moon, Hyun Suk;Lee, Sang Woo
    • The KSFM Journal of Fluid Machinery
    • /
    • v.16 no.6
    • /
    • pp.19-25
    • /
    • 2013
  • The effect of tip gap height on heat/mass transfer characteristics on the floor of cavity squealer tip has been investigated in a turbine cascade for power generation by employing the naphthalene sublimation technique. The squealer rim height is chosen to be an optimal one of $h_{st}/c$ = 5.51% for the tip gap height-to-chord ratios of h/c = 1.0, 2.0, 3.0 and 4.0%. The results show that heat transfer on the cavity floor is strongly dependent upon the behavior of the cavity flow falling down onto the floor. For lower h/c, the floor heat transfer is influenced by the tip leakage flow falling down along the inner face of the suction-side squealer, whereas the floor heat transfer for higher h/c is augmented mainly due to the impingement of leakage flow on the floor near the leading edge. Compared to the plane tip surface heat transfer, the cavity floor heat transfer is less influenced by h/c. For h/c = 1.0%, the average thermal load is as low as a half of the plane tip surface one, and the difference in the thermal load between the two cases tends to decrease with increasing h/c.

National-Wide Survey on Endotracheal Suctioning in High-Risk Infants (고위험신생아를 위한 기관지흡인에 대한 실태조사)

  • Ahn Youngmee
    • Child Health Nursing Research
    • /
    • v.5 no.2
    • /
    • pp.198-210
    • /
    • 1999
  • The goal of respiratory management in high risk infants is to maintain proper oxygenation by supporting respiration, therefore to minimize the secondary complications and to promote the maximum growth and development. While on artificial ventilator to achieve this goal, the infants require endotracheal suctioning(ETS) to remove lung secretions. However, the negative effects of ETS in neoates have been documented and include hypoxia, bradycardia, mucosal damage, increased intracranial pressure, and death result. The purpose of the study was to investigate how ETS is currently performed in NICU, which would be beneficial to develop the standardized ETS protocol and to apply it to these population. A national-wide survey on clinical protocol of ETS was performed to 149 neonatal nurses with the average of 3 years and 6 months experience in neonatal nursing, 34.2% of whom was bachelor in nursing. The results showed that about 89% of the nurses initiate En primarily based on the need of the subjects. The aseptic regulation on ETS was used in 83.9% of the subjects. There was no regulation on the length of catheter in 32.9% and on ID/OD ratio in 17.4%. Many nurses administered hyperoygenation/hyperinflation/hyperventilation based on personal knowhow, rather than scientific rationals (77.2%, 40.9%, 75.2%, retrospectively). About 41% of the nurse regulate subjectively the suction power, while 73.8% of them rotate the sub ject's head during suctioning and the half of the nurses was favorable in adapting the closed-suctioning protocol. With the findings of the study, the current clinical application of E% in neonates appears to be based on adult care practices, or personal preference, rather than scientific validation of the safety and effectiveness of the procedure. This study support the needs for developing and applying the standardized ETS protocolin conjunction with the consideration given to the physiologic characteristics of the neonates in respiratory distress.

  • PDF

The Operational Characteristics of High-speed Interrupter by Fault Types (고장 유형별 고속 인터럽터의 동작 특성)

  • Jeong, In-Sung;Choi, Hyo-Sang;Jung, Byung-Ik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.2
    • /
    • pp.278-283
    • /
    • 2013
  • With the increasing power demands, size of the fault current in electrical grids is steadily increasing, and it exceeds the breaking capacity of circuit breakers. To effectively cope with these problems, a high-speed interrupter was suggested. The high-speed interrupter provides fault current with a bypass to a fault current limiter in case of accidents and consequently, fault current can be restricted. In this study, behavioral characteristics of high-speed interrupter were analyzed by accident types occurred in a distribution system. When accidents occurred, a and b contact of the high-speed interrupter were turned-off and then, turned-on. Accordingly, fault current flowed to the circuit connected to a current limiting element, and the fault current limiter restricted fault current to within a half-cycle. Nevertheless, the behavior of the high-speed interrupter was slowed down by a switching surge. As a result, fault current was confirmed to be restricted not to within the anticipated half-cycle, but to after a half-cycle. Moreover, the behavioral characteristics of the high-speed interrupter changed not only by accident types, but by behaviors of R, S, and T phases. This was due to the errors in stroke lengths of the high-speed interrupters, which resulted in a slight time discrepancy among three interrupters. In addition, the switching behaviors of the b and a contact were confirmed not to have coincided due to the switching surge; b contact behaved first and a contact followed. because of this, accuracy of stroke length and switching surges through the solenoid suction increases may be necessary to resolve.

Optimal Design of RSOFC System Coupled with Waste Steam Using Ejector for Fuel Recirculation (연료 재순환 이젝터를 이용한 연료전지-폐기물 기반 가역 고체 산화물 연료전지의 최적 설계)

  • GIAP, VAN-TIEN;LEE, YOUNG DUK;KIM, YOUNG SANG;QUACH, THAI QUYEN;AHN, KOOK YOUNG
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.4
    • /
    • pp.303-311
    • /
    • 2019
  • Reversible solid oxide fuel cell (RSOFC) has become a prospective device for energy storage and hydrogen production. Many studies have been conducted around the world focusing on system efficiency improvement and realization. The system should have not only high efficiency but also a certain level of simplicity for stable operation. External waste steam utilization was proved to remarkably increase the efficiency at solid oxide electrolysis system. In this study, RSOFC system coupled with waste steam was proposed and optimized in term of simplicity and efficiency. Ejector for fuel recirculation is selected due to its simple design and high stability. Three system configurations using ejector for fuel recirculation were investigated for performance of design condition. In parametric study, the system efficiencies at different current density were analyzed. The system configurations were simulated using validated lumped model in EBSILON(R) program. The system components, balance of plants, were designed to work in both electrolysis and fuel cell modes, and their off-design characteristics were taken into account. The base case calculation shows that, the system with suction pump results in slightly lower efficiency but stack can be operated more stable with same inlet pressure of fuel and air electrode.

Experimental research on design wind loads of a large air-cooling structure

  • Yazhou, Xu;Qianqian, Ren;Guoliang, Bai;Hongxing, Li
    • Wind and Structures
    • /
    • v.28 no.4
    • /
    • pp.215-224
    • /
    • 2019
  • Because of the particularity and complexity of direct air-cooling structures (ACS), wind parameters given in the general load codes are not suitable for the wind-resistant design. In order to investigate the wind loads of ACS, two 1/150 scaled three-span models were designed and fabricated, corresponding to a rigid model and an aero-elastic model, and wind tunnel tests were then carried out. The model used for testing the wind pressure distribution of the ACS was defined as the rigid model in this paper, and the stiffness of which was higher than that of the aero-elastic model. By testing the rigid model, the wind pressure distribution of the ACS model was studied, the shape coefficients of "A" shaped frame and windbreak walls, and the gust factor of the windbreak walls were determined. Through testing the aero-elastic model, the wind-induced dynamic responses of the ACS model was studied, and the wind vibration coefficients of ACS were determined based on the experimental displacement responses. The factors including wind direction angle and rotation of fan were taken into account in this test. The results indicated that the influence of running fans could be ignored in the structural design of ACS, and the wind direction angle had a certain effect on the parameters. Moreover, the shielding effect of windbreak walls induced that wind loads of the "A" shaped frame were all suction. Subsequently, based on the design formula of wind loads in accordance with the Chinese load code, the corresponding parameters were presented as a reference for wind-resistant design and wind load calculation of air-cooling structures.

A study on the working mechanism of internal pressure of super-large cooling towers based on two-way coupling between wind and rain

  • Ke, Shitang;Yu, Wenlin;Ge, Yaojun
    • Structural Engineering and Mechanics
    • /
    • v.70 no.4
    • /
    • pp.479-497
    • /
    • 2019
  • In the current code design, the use of a uniform internal pressure coefficient of cooling towers as internal suction cannot reflect the 3D characteristics of flow field inside the tower body with different ventilation rate of shutters. Moreover, extreme weather such as heavy rain also has a direct impact on aerodynamic force on the internal surface and changes the turbulence effect of pulsating wind. In this study, the world's tallest cooling tower under construction, which stands 210m, is taken as the research object. The algorithm for two-way coupling between wind and rain is adopted. Simulation of wind field and raindrops is performed iteratively using continuous phase and discrete phase models, respectively, under the general principles of computational fluid dynamics (CFD). Firstly, the rule of influence of 9 combinations of wind speed and rainfall intensity on the volume of wind-driven rain, additional action force of raindrops and equivalent internal pressure coefficient of the tower body is analyzed. The combination of wind velocity and rainfall intensity that is most unfavorable to the cooling tower in terms of distribution of internal pressure coefficient is identified. On this basis, the wind/rain loads, distribution of aerodynamic force and working mechanism of internal pressures of the cooling tower under the most unfavorable working condition are compared between the four ventilation rates of shutters (0%, 15%, 30% and 100%). The results show that the amount of raindrops captured by the internal surface of the tower decreases as the wind velocity increases, and increases along with the rainfall intensity and ventilation rate of the shutters. The maximum value of rain-induced pressure coefficient is 0.013. The research findings lay the basis for determining the precise values of internal surface loads of cooling tower under extreme weather conditions.

Evaluation of unsaturated soil slope stability by incorporating soil-water characteristic curve

  • Zhai, Qian;Tian, Gang;Ye, Weimin;Rahardjo, Harianto;Dai, Guoliang;Wang, Shijun
    • Geomechanics and Engineering
    • /
    • v.28 no.6
    • /
    • pp.637-644
    • /
    • 2022
  • Loess soils are unsaturated and widely distributed in the northwest zone in China. Many steep slope of unsaturated are observed are observed to be naturally stable. However, a low factor of safety (FoS) for these slopes would be computed from the slope stability analysis following local code practices. It seems that the analyzed results following the local code practices do not agree with the real condition as observed in the field. It is commonly known that soil suction plays an important role in slope stability due to a higher shear strength of the unsaturated soil as compared with that of the saturated soil. In this paper, it is observed that the computed FoS can also be affected by unsaturated unit weight of the soil. However, the effect of unsaturated unit weight of the soil on the slope stability is commonly ignored in engineering practice. Therefore, both the effects of shear strength and unit weight of the unsaturated soil on the computed FoS of unsaturated soil slope are investigated in this study. It is observed that the unsaturated unit weight of soil on the computed FoS increases with increase in slope angle. It is also observed that the effects of the unsaturated shear strength and unsaturated unit weight on the computed FoS are more significant than the effect of 3D analyses compared to the 2D analyses on the FoS.

A Tracer Experiment of Sediment Transport Path Using Fluouescent-Tagged Sands (형광사를 이용한 표사이동경로 추적 실험)

  • Jeong, Sin-Taek;Jo, Hong-Yeon;O, Yeong-Min;Kim, Chang-Wan
    • Journal of Korea Water Resources Association
    • /
    • v.32 no.5
    • /
    • pp.547-555
    • /
    • 1999
  • The economical manufacturing process of fluorescent sediments (FS) which makes use of the understanding of coastal sediment path has been suggested with respect to the Lagrangian viewpoint. First, the fluorescent liquids were made by the mixing of the fluorescent materials, acetone, and xylene. Second, the sediments collected in Gamami beach were desalinized by the freshwater washing, dried indoors to protect the fine-sediment scattering, and classified by the sieve analysis. Finally, the FS which have seven different colors were manufactured by the mixing of fluorescent liquids and prepared sediments. The FS were used to figure out the major sediment supply routes of the intake channel in the YoungKwang nuclear power plant. From the field experiments, it was shown that the sediments were suspended and dispersed by the strong seasonal NW wind and the tide, and the sediments in suspension were flowing into the intake channel due to very strong suction speed. All the FS injected in stations were detected in the channel sampling points, thus we concluded that the sediments in suspension and dispersion were flowing into the intake channel from all directions in adjacent coastal zone.

  • PDF

Experimental Study on Development of Oscillating Sieve Separation Method for Improving Threshing Performance (탈곡성능(脱糓性能) 향상(向上)을 위(爲)한 요동(搖動)체 선별방법(選別方法) 개발(開發)에 관(關한) 연구(硏究))

  • Kim, Sang Hun;Chung, Chang Joo;Yoo, Soo Nam
    • Journal of Biosystems Engineering
    • /
    • v.6 no.2
    • /
    • pp.33-47
    • /
    • 1982
  • To modernize the conventional rice post production technology and reduce grain losses, a transition toward the wet-paddy threshing system has been strongly demanded. The head-feeding type thresher with pneumatic separation has been used dominantly for threshing dried-paddy, but some adverse effects in separation performance for threshing wet-paddy is encounterred. In order to solve the problems, the development of thresher with an additional oscillating sieve to the conventional pneumatic separation has been recommanded. This study was intended to evaluate the separating performance of thresher with oscillating sieve which was attached additionally to the conventional auto-thresher equipped with separation system of blower and suction fan. For different feed rates and rice varieties, wet-and dry-material were tested with threshers attached with and without oscillating sieve. Results of the study are summarized as follows: 1. When the feed rates were 480 and 640 kg/hr, there was no statistically significant difference in power reqirements between the threshers with and without an additional sieve device for both dry-and wet-threshing. However, when the feed rate was 960 kg/hr, power requirements of thresher without sieve were greater for wet-paddy threshing than the thresher with the additional sieve separator by about 20% points. 2. With additional oscillating sieve device, the ratios of total weights of whole grains including grains with branch let and damaged grains to the total output did not show statistical difference among the feed rates. However, with pneumatic separation the ratio was decreased as the level of feed rate increased. 3. The total amount of grains with branchlet (including broken panicle) increased with the moisture content. For both the wet-and dry-material threshing with the additional oscillating sieve, the percent of grains with branchlet to the total output decreased greatly as the feed rate increased. 4. The output of the damaged grains increased as moisture content decreased. Especially, for the dry-paddy threshing, the additional sieve separating device produced more damaged grains than the pneumatic separation at all feed rates. 5. Generally, for dry paddy threshing, the separating performance of the thresher with the additional sieve device was better at all feed rates, showing greater difference with increasing feed rates. 6. Separating losses were greater with the pneumatic than sieve separation for both the wet-and dry-threshing. 7. The overall comparison of separating performance of threshers tested with and without an additional sieve device showed that the former was more effective than the latter for the dry-material threshing. However, for the wet-paddy threshing, the separation performance with a sieve device was better than the pneumatic only when the feed rate was high.

  • PDF