• 제목/요약/키워드: Suction Pump

검색결과 209건 처리시간 0.026초

제로터 펌프의 측판 설계 (Design of the Port Plate for Gerotor Pumps)

  • 남윤주;박명관
    • 대한기계학회논문집B
    • /
    • 제28권4호
    • /
    • pp.406-414
    • /
    • 2004
  • In Gerotor pump, the pressure pulsations which occur due to the pump geometry result in vibration and noise of pump elements as well as cavitation in hydraulic system when the chambers of gerotor enter the delivery port and leave the suction port. Therefore it is important to study on the pressure pulsations before design and analysis of characteristics in Gerotor pump. In this paper, to reduce the unnecessary pressure pulsations, the port plate of Gerotor pump is designed based on the notch of the vane pumps and the relief grove of the piston pumps. The theoretical analysis of the pressure pulsations is performed in consideration of design parameters of the port plate which include each port positions and groove width and operating conditions which include rotational velocity and delivery pressure.

산업용 수직펌프의 흡입성능 향상 연구 (A Study of NPSH Required Performance Improvement for a Industrial Vertical Pump)

  • 정경남;박종후;김용균;김해천
    • 대한기계학회논문집B
    • /
    • 제33권11호
    • /
    • pp.909-915
    • /
    • 2009
  • In this paper, a study of performance improvement for a centrifugal vertical pump having specific speed of 330 is introduced. The existing model has high efficiency but needs better NPSH required performance. Such that new pump model is designed to obtain larger suction specific speed. 6 design parameters considered to affect pump performance are selected for impeller design. Key design parameters are investigated using by design of experiments and CFD, and impeller inlet diameter is increased to get better suction performance. The amount of inlet diameter increase is determined by using cavitation analysis. The results show that new design model has higher efficiency and better NPSH required performance than the existing model.

Elevation of Depressed Skull Fracture with a Cup of Breast Pump and a Suction Generator : A Case Report in Technical Aspects

  • Kim, Young-Jin;Lee, Sang-Koo;Cho, Maeng-Ki;Kim, Young-Joon
    • Journal of Korean Neurosurgical Society
    • /
    • 제42권4호
    • /
    • pp.346-348
    • /
    • 2007
  • Surgical elevation of the depressed bone is known to be the conventional treatment usually recommended for a simple depressed skull fracture in the adult or pediatric age. The authors introduce, however, a case of depressed skull fracture in an infant which was elevated by means of a cup of breast pump and a suction generator without surgical elevation. In our case, without surgery, a 'cup-shaped' depressed skull fracture in an infant was safely elevated with no neurological signs. This method is considered a simple, effective, safe, and alternative procedure in an infant with simple depressed skull fracture.

원심펌프의 성능개선과 캐비테이션 억제에 관한 연구 (Improvement of Pump Performance and Suppression of Cavitation in a Centrifugal Pump)

  • 최영도;쿠로카와준이치
    • 한국유체기계학회 논문집
    • /
    • 제11권1호
    • /
    • pp.18-25
    • /
    • 2008
  • Recent trends of a centrifugal pump are high speed in rotation and high pressure in head with high efficiency to meet the demands of industries. However, the newly developed pumps make trouble of pressure pulsation in the pumping system by performance instability of the pump. Moreover, cavitation, which is a main obstacle of high rotational speed in the pump, occurring in an impeller gives serious damages to the impeller and casing wall. The purpose of present study is not only to develop a simple method to improve pump performance but also to suppress the occurrence of cavitation in the centrifugal pump by use of J-Groove. J-Groove is a shallow groove installed on the casing wall in the meridional direction. The application of J-Groove to a centrifugal pump with a new type impeller of "semi-closed impeller" has proved its effectiveness as a useful countermeasure of the unstable pump performance and cavitation. The results show that the combination of semi-closed impeller and J-Groove can be applied successfully and improves both the pump performance and suction performance.

경남지역 치과의원 의료폐기물 관리실태 (Dental Waste Management Practices at Dental Offices in Gyeongsangnam-do)

  • 김해진;사공준
    • 한국환경보건학회지
    • /
    • 제38권4호
    • /
    • pp.332-339
    • /
    • 2012
  • Objectives: The purpose of this study was to prevent health problems and environmental contamination resulting from inappropriate management of dental wastes and to provide reference data for revision and supplementation of dental clinic waste management guidelines. Methods: From 640 total of dental clinics registered in 16 cities and counties in Gyeongsangnam-do, 100 (60 in Changwon (Masan, Changwon), 29 in Gimhae, and 11 in Jinju) were included in this study. From July 2010 to September 2010, investigators visited the 100 dental clinics and conducted survey interviews using a structured survey questionnaire regarding disposal methods for liquid wastes (suction pump, spittoon container waste, used liquid disinfectants, and X-ray developer), and disposal methods for solid waste (suction pump, spittoon container waste, and general medical waste). Results: All the 100 dental clinics were found to treat liquid waste from suction pumps and spittoon containers in the same manner as general waste water. Nineteen percent of the clinics treated solid waste that was not filtered through the filter of a suction pump as general waste. Fifty or more percent of the clinics treated solid waste in spittoon containers as general waste. Seventy percent of the clinics used disinfectant solution, although most of them treated used disinfectants in the same manner as general waste water. Some clinics treated used X-ray developer and X-ray fixer in the same manner as general waste water. In most of the clinics, used drapes were washed within the clinic. Conclusions: It was found that waste water and dental wastes at some dental clinics were treated in inappropriately. Thus, in conclusion, the development of guidelines regarding proper management of liquid and solid dental waste at dental clinics is required, and hygiene and environmental training for workers at dental clinics is necessary.

진동응답 측정에 의한 이중 벌류트형 양흡입 원심펌프의 동적특성 (Dynamic Characteristics of the Double Volute Double Suction Centrifugal Pump Using Measured Vibration Data)

  • 최복록;박진무
    • 소음진동
    • /
    • 제10권3호
    • /
    • pp.500-507
    • /
    • 2000
  • Dynamic forces due to mechanical and hydraulic related causes are always exerted on operating turbomachinery such as centrifugal pumps. To ensure the safety and the reliability of the pump. the magnitudes of the vibration must be kept within an acceptable limit. The focus of this paper is on the identification of the vibration behavior and the quantitative analysis of the hydraulic excitation forces. As the structure becomes more complex finite element analysis is essential to accurately predict the vibration characteristics and the excitation forces, This paper presents an experimental and analytical technique to find and solve to vibration problems in double volute double suction centrifugal pump. Measured vibration data due to the dynamic forces are presented and individual causes are identified, finally excitation forces of the pump are inversely estimated at each frequency on operating conditions.

  • PDF

컴플라이언스 계수에 의한 노즐하중 하에서의 원심펌프의 축단변위에 관한 연구 (A Study on the Shaft End Displacement of the Centrifugal Pump under Nozzle Loads using Compliance Coefficients)

  • 최복록;박진무;김광은
    • 한국정밀공학회지
    • /
    • 제17권4호
    • /
    • pp.233-239
    • /
    • 2000
  • Investigation results are presented fur the shaft end displacements due to the elastic deformation of the casing and support in double suction centrifugal pump. Suction and discharge nozzles of the pump are subject to external piping loads and, in API 610, maximum values of their components are specified. This means that each nozzle can be subject to various combinations of loading conditions. Considering upper and lower criteria of each load, we must perform for the 4,096 load cases, and assign the direction and range of the loads. So, this paper develops an efficient procedure(Compliance Coefficient Method) to calculate the shaft end displacements(@ coupling) to determine whether satisfying the pump's standard. Also, we analyzed the effects of the casing and support thickness on shaft end displacements.

  • PDF

원심펌프 측면흡입구의 유동특성에 관한 수치해석적 연구 (A Numerical Study on the Flow Characteristics of Side-suction Inlet Geometry for Centrifugal Pump)

  • 김성;최영석;이경용
    • 한국유체기계학회 논문집
    • /
    • 제12권6호
    • /
    • pp.7-12
    • /
    • 2009
  • This paper presents a numerical study on the design of side-suction inlet geometry which is used for multi stage centrifugal pumps or inline centrifugal pumps. In order to achieve an optimum inlet geometry and to explain the interactions between the different geometric configurations, the three dimensional computational fluid dynamics and the design of experiment methods have been applied. Geometric design variables describing the cross sectional area distribution through the inlet were selected. The objective functions are defined as the non-uniformity of the velocity distribution at the passage exit which is just in front of the impeller eyes. From the 2k factorial design results, the most important design variable was found and the performance of the side suction inlet was improved compared to the base line shape.

피스톤 펌프 기법을 이용한 흙-수분 특성곡선 측정방법 (Determination of the Soil-water Characteristic Curve Using the Flow Pump Technique)

  • 황창수;김태형
    • 한국지반공학회논문집
    • /
    • 제19권5호
    • /
    • pp.155-162
    • /
    • 2003
  • 흙-수분 특성곡선은 토질역학에서 불포화토의 근간이 되는 중요한 물성함수로 불포화토 연구에 있어서 가장 중요한 요소이다. 따라서 이러한 흙-수분 특성곡선을 보다 정확하고 빠르게 또 편리하게 측정할 수 있는 신뢰성 있는 방법이 불포화토 연구에 있어서 우선적으로 요구되고 있다. 본 연구에서는 피스톤 펌프 기법을 이용한 흙-수분 특성곡선 측정방법을 보완, 발전시켰다. 이 방법은 기존의 흙-수분 특성곡선 측정방법들보다 측정하기에 편리하고 빠르며 더욱 정확한 측정이 가능하다. 또한 전체실험 과정을 통하여 완전한 통제가 가능하며 컴퓨터를 이용한 자동화 및 정밀측정이 가능하기 때문에 흙-수분 특성곡선의 상세한 부분까지 연구할 수 있다. 한 점 한 점이 아닌 연속적인 건조곡선이나 습윤곡선의 측정이 가능하고 건조곡선에서의 공기침입값 위치라든지 습윤곡선에서의 공기폐색위치등도 측정 가능하다. 또한 불포화토의 특성중의 하나인 흙-수분 특성곡선의 이방성 측정도 가능하다. 본 연구에서는 실험방법상의 기법을 개발했을 뿐만 아니라 실험결과에 대한 구체적인 해석도 이루어졌다. 실례로 석션조절기법(suction drop measurement)이라는 방법을 개발했으며 이 방법을 이용하면 흙-수분 특성곡선을 보다 편리하고 또 짧은 시간 내 정확하게 측정할 수 있다.