• Title/Summary/Keyword: Suction Pump

Search Result 210, Processing Time 0.023 seconds

A Preliminary Analysis of Large Loss-of-Coolant Induced by Emergency Core Coolant Pipe Break in CANDU-600 Nuclear Power Plant

  • Ion, Robert-Aurelian;Cho, Yong-Jin;Kim, In-Goo;Kim, Kyun-Tae;Lee, Jong-In
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05b
    • /
    • pp.435-440
    • /
    • 1996
  • Large Loss-of-Coolant Accidents analyzed in Final Safety Analysis Reports are usually covered by Reactor Inlet Header. Reactor Outlet Header and Primary Pump Suction breaks as representative cases. In this study we analyze the total (guillotine) break of an Emergency Core Cooling System (ECCS) pipe located at the ECCS injection point into the Primary Heat Transport System (PHTS). It was expected that thermal-hydraulic behaviors in the PHT and ECC systems are different from those of a Reactor Inlet Header break, having an equivalent break size. The main purpose of this study is to get insights on the differences occurred between the two cases and to assess these differences from the phenomenon behavior point of view. It was also investigated whether the ECCS line break analysis results could be covered by header break analysis results. The study reveals that as the intact loop has almost the same behavior in both analyzed cases. broken loop behavior is different mostly regarding sheath temperature in the critical core pass and pressure decrease in the broken Reactor Inlet Header. Differences are also met in the ECCS behavior and in event sequences timings.

  • PDF

A Study on Numerical Simulation for the Work Environment Improvement of Highway Tollgate Booth (고속도로 요금소 부스 근무환경 개선을 위한 기류해석 연구)

  • 김신도
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.2
    • /
    • pp.129-140
    • /
    • 2000
  • Simulation study has been carried out to analyze the air flow supplying from the heat pump system inside the tollgate booth by using the Phoenix computer simulation program. Through this simulation analysis we can find the problem of present tollgate booth in terms of air flow and recommend an improved model also simulate this model. Final results as follows; It was turned out that the fresh air conditioning is not provided to the worker effectively due to the improper location of inlet and outlet in the present tollgate booth in addition to that the air curtain system applied in the booth lowered air circulation from outside. The improved model was suggested first to increase the air curtain effect by downsizing the window and by installation of the air curtain suction line to reduce the induced outdoor air second to supply the fresh air to the worker directly by relocation of the inlet and outlet of supplying air. With these improved modifications better results have been reached in terms of air flow inside the booth. Next through the air flow simulation of outside booth the contaminated outdoor air has been easuily infiltrating into the booth through the window because of its rectangle shape. Stream like shape of booth has been proposed through the computer simulation as an alternative shape of tollgate booth for a new design.

  • PDF

Design Optimization of Centrifugal Pumps (원심 펌프의 최적 설계)

  • Oh, Hyoung Woo;Chung, Myung Kyoon;Kim, Sang Chul;Yang, Keun Yung;Ha, Jin Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.254-261
    • /
    • 1999
  • An optimal design code for centrifugal pumps has been developed to determine geometric and fluid dynamic variables under appropriate design constraints. The optimization problem has been formulated with a nonlinear objective function to minimize one, two or all of the fluid dynamic losses, the net positive suction head required and the product price of a pump stage depending on the weighting factors selected as the design compromise. The optimal solution Is obtained by means of the Hooke and Jeeves direct search method. The performance analysis Is based on the mean streamline analysis using the present state-of-the-art loss correlations. The optimized efficiency and design variables of centrifugal pumps are presented in this paper as a function of non-dimensional specific speed in the range, $0.5{\leq}N$, ${\leq}1.3$. The diagrams presented herein can be used efficiently in the preliminary design phase of centrifugal pumps.

Automatic Unloading System for Modernizing the Busan Cooperative Fish Market (부산공동어시장 현대화를 위한 양륙자동화설비 구축 방안에 관한 연구)

  • Lee, Kyung-Chang;Jung, Young-Seok;Kwak, Sung-Woo;Sohn, Jeong-Hyun
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.1
    • /
    • pp.88-94
    • /
    • 2021
  • Currently, the Busan cooperative fish market follows a traditional market style. This study first investigates the current conditions and environment of the market, and to modernize the market, it proposes a new automatic unloading system based on the benchmark of Namhae Suhyup. In this system, a Korean-type suction fish vacuum pump is employed to increase the loading time. An automatic grader with an adjusting device for inclined angles and a weighing machine with an automatic alignment device are proposed. In addition, a folding machine is employed to prepare boxes. The specifications for each subsystem are provided. By implementing this system, the freshness of fish can be maintained and the sellers can earn more. This system can also be applied to the cooling system of the fish reservoir of littoral sea fishing boats.

The plan of depreciation vortex developing a Pump suction Pipes through Sump model test (수리모형실험을 통한 펌프 흡입배관부 보텍스 현상 저감방안)

  • Ahn, IS;Kim, SH;Kim, KY;Roh, HW;Lee, YH
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.193-198
    • /
    • 2004
  • In general, the function of intake structure, whether it be a open channel, a fully wetted tunnel, a sump or a tank is to supply an evenly distributed flow to a pump station. An even distribution of flow, characterized by strong local flow, can result in formation of surface or submerged vortices, and with certain low values of submergence, my introduce air into pun, causing a reduction of capacity and efficiency, an increase in vibration and additional noise. This study investigated experimentally the formation of the vortex to understand the mechanism of vortex formation and to prevent the formation of vortex in the sump model using by the model test and PIV tool. Sump model was manufactured to 1/8 scale with the drawing of W intake pumping station. from the results of model test and PIV, the vortex were occurred the in the whole section. Thus, sump model tests with the anti-vortex device might be considered to prevent the formation of vortex in the sump model.

  • PDF

Conceptual Design of Mechanical System for Recovery of Seabed-Deposited Hazardous and Noxious Substances Based on Performance Requirements (해저침적 HNS 회수용 기계장치의 성능요건 기반 개념설계)

  • Hwang, Ho-Jin
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.26 no.6
    • /
    • pp.689-697
    • /
    • 2020
  • Hazardous and noxious substances (HNS) may cause maritime incidents during marine transportation, which are liable to lead to a large amount of spillage or discharge into the sea. The damage to the marine environment caused by the HNS spill or discharge is known to be much greater than the damage caused by oil spill. Particularly dangerous is HNS, which is deposited or buried in the seabed, as it can damage the organisms that live on, in, and near the bottom of the sea, the so-called "benthos," forming the benthic ecosystem. Therefore, it is vital that the HNS deposited on the seabed be recovered. In order to do so, procedures and equipment are required for accurate detection, stabilization treatment, and recovery of HNS in subsea sediment. Thus, when developing a mechanical recovery system, the performance requirements should be selected using performance indices, and the conceptual design of the mechanical recovery system should be based on performance requirements decided upon and selected in advance. Therefore, this study was conducted to arrive at a conceptual design for a mechanical recovery system for the recovery of HNS deposited on the seabed. In the design of the system, based on the fundamental scenario, the method of suction foundation with the function of self enclosing was adopted for recovering the HNS sediment in the subsea sediment. The mechanical recovery system comprises the suction foundation, pollution prevention, a pump system, control system, monitoring device, location information device, transfer device, and tanks. This conceptual design is expected to be reflected and used in the basic design of the components and shapes of the mechanical recovery system.

A Case Study on the TEMAZ Explosion Accident in Semiconductor Process (반도체 공정에서 TEMAZ폭발사고 사례연구)

  • Yang, Won-Baek;Rhim, Jong-Kuk;Hong, Seong-Min
    • Journal of the Korean Institute of Gas
    • /
    • v.21 no.6
    • /
    • pp.52-60
    • /
    • 2017
  • In diffusion process exhaust line during semiconductor manufacturing process, In order to improve the transportation efficiency in the piping by removing "The reaction by-product, $ZrO_2$ and The unreacted material, TEMAZ, TMA, $O_3$, etc" and "Powder being deposited", the piping temperature was raised to $80^{\circ}C$ or more by using the heater jacket, and the bellows at the rear end of the vacuum pump ruptured. So conducted a case study and try to prevent the similar accidents from occurring through case studies. The causes of the accident were analyzed as follows: the inflow of outside air due to the generation of a gap on the suction side of the vacuum pump and heating the pipe with the heater jacket resulted in the overpressure in the pipe due to the volumetric expansion of the gas generated by decomposition of the unreacted TEMAZ, It can be assumed that the most vulnerable bellows of the piping has been ruptured. In order to prevent such accidents, This study is aimed to identify the cause of pipeline rupture accident and to establish safety measures for the prevention of similar accidents by evaluating physical hazards of TEMAZ, which is assumed to be the cause of pipe rupture accident.

Separation characteristics of separation devices using inlet water mixed with exhalation gases without a compressor (날숨이 혼합된 물을 사용한 압축기없는 용존기체 분리기의 분리 특성)

  • Heo, Pil Woo
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.40 no.9
    • /
    • pp.842-846
    • /
    • 2016
  • It's possible for a human to breathe under water, but the amount of dissolved oxygen in the water is small and a large amount of water is necessary to obtain sufficient dissolved oxygen from water. So, large separation system with large water pumps, having large surface areas, and large battery sources are needed. Exhalation gases are used to solve this problem. Theses gases contain some oxygen, nitrogen, and carbon dioxide; they contain less oxygen and more carbon dioxide compared to air. Therefore, reduction of the amount of carbon dioxide is necessary. If exhalation gases are employed appropriately, the separation device can be made more compact. Inlet water mixed with exhalation gases is supplied into the separation device, and dissolved gases are separated from the mixed water as it passes through the device. The inlet part of a typical separation system with a water delivery pump before the membrane module has more than one atmosphere. Hence, a compressor is used to mix the exhalation gases. In this study, the pressure at the inlet due to the use of a suction pump after the membrane module was less than one atmosphere; hence, compressors were not required. Separation characteristics were studied using a separation device without a compressor. The use of exhalation gases led to an increase in the amount of dissolved gases being separated. As the amount of inlet exhalation gases was increased, the separation of dissolved gases was increased as well.

Development and Evaluation of a Patient Safety-focused Inservice Education Program for Surgical Nurse (외과계 간호사를 위한 환자안전 관점의 실무교육 프로그램 개발과 효과)

  • Kim, Young-Mee;You, Myung-Sook;Cho, Yaun-Hee;Park, Seung-Hee;Nam, Seung-Nam;Park, Mi-Ok;Kim, Se-Young;Kim, Min-Young
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.16 no.2
    • /
    • pp.152-161
    • /
    • 2010
  • Purpose: The aim of this project was to develop a patient safety-focused inservice education program for surgical nurse and to test the effects of this program. Methods: Methodological designs for instruments development, a pretest-posttest and a posttest design were employed. After the education, nurses' satisfaction, confidence, usefulness and application of 137 nurses were evaluated at 15 surgical units of a tertiary teaching hospital in Seoul, Korea. The education contents are 6 skill areas (infusion pump use, suction, chest tube drainage, oxygen administration, nebulizer use, insulin administration) and medication knowledge. Teaching methods were lecture, instructor demonstration, and 1:1 skill test. Descriptive statistics, Wilcoxon test, Spearman's correlation and Stepwise regression were used. Results: Satisfaction scores for skills and medication education were 4.00-4.21 (out of 5), The more performance frequency in 6 skills, the higher score in confidence as well as in usefulness and application, and the higher satisfaction with the program, the higher score in usefulness, application, confidence, and medication knowledge. Medication knowledge improved after the education (Z=-7,757, p<.001). Significant predictors of skill confidence were application of skills in job performance, medication confidence, and career in present unit. Conclusion: The results of this study suggest that systematic and continuous inservice education will improve patient safety by promoting nursing quality.

Mixed Flow and Oxygen Transfer Characteristics of Vertical Orifice Ejector (수직 오리피스 이젝터의 혼합유동 및 산소전달 특성)

  • Kim, Dong Jun;Park, Sang Kyoo;Yang, Hei Cheon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.39 no.1
    • /
    • pp.61-69
    • /
    • 2015
  • The objective of this study is to experimentally investigate the mixed flow behaviors and oxygen transfer characteristics of a vertical orifice ejector. The experimental apparatus consisted of an electric motor-pump, an orifice ejector, a circulation water tank, an air compressor, a high speed camera unit and control or measurement accessories. The mass ratio was calculated using the measured primary flow rate and suction air flow rate with experimental parameters. The visualization images of vertically injected mixed jet issuing from the orifice ejector were qualitatively analyzed. The volumetric oxygen transfer coefficient was calculated using the measured dissolved oxygen concentration. At a constant primary flow rate, the mass ratio and oxygen transfer coefficient increase with the air pressure of compressor. At a constant air pressure of the compressor, the mass ratio decreases and the oxygen transfer coefficient increases as the primary flow rate increases. The residence time and dispersion of fine air bubbles and the penetration of mixed flow were found to be important parameters for the oxygen transfer rate owing to the contact area and time of two phases.