• Title/Summary/Keyword: Subtraction technique

Search Result 150, Processing Time 0.019 seconds

Assessment of apical root resorption using digital subtraction radiography (디지털공제방사선촬영술을 이용한 치근단 흡수의 평가)

  • Heo Min-Suk;Lee Sam-Sun;Lee Kyung-Hee;Choi Hang-Moon;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.51-55
    • /
    • 2001
  • Purpose : This study was performed to compare the diagnostic ability of conventional intraoral radiographs with that of digital subtraction image and to assess the quantifying ability of digital subtraction image for simulated apical root resorption Materials and Methods : Conventional intraoral radiographs and digital images of ten sound maxillary central incisors and those with simulated apical root resorption were taken with varying horizontal and vertical angulations of the x-ray beam. The diagnostic accuracy to detect the lesion was evaluated on conventional intraoral radiographs and digital subtraction images by ROC analysis. The amount of simulated apical root resorption was also estimated on the reconstruction images by Emago/sup (R)/ and compared with actual amount of tooth loss using paired t-test. Results: The diagnostic accuracy of conventional intraoral radiographs to detect the apical root resorption was low (ROC area = 0.6446), and the sensitivity and the specificity of digital subtraction images were 100%, respectively. The calculated amounts of apical root resorption showed no statistically significant difference with the actual amounts of the lesion (p>0.05). Conclusion: Digital subtraction radiography is powerful tool to detect the small apical root resorption, and quantitative analysis of small amounts of the lesion can be evaluated by digital subtraction radiography.

  • PDF

Material Decomposition through Weighted Image Subtraction in Dual-energy Spectral Mammography with an Energy-resolved Photon-counting Detector using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 광자계수검출기 기반 이중에너지 스펙트럼 유방촬영에서 가중 영상 감산법을 통한 물질분리)

  • Eom, Jisoo;Kang, Sooncheol;Lee, Seungwan
    • Journal of radiological science and technology
    • /
    • v.40 no.3
    • /
    • pp.443-451
    • /
    • 2017
  • Mammography is commonly used for screening early breast cancer. However, mammographic images, which depend on the physical properties of breast components, are limited to provide information about whether a lesion is malignant or benign. Although a dual-energy subtraction technique decomposes a certain material from a mixture, it increases radiation dose and degrades the accuracy of material decomposition. In this study, we simulated a breast phantom using attenuation characteristics, and we proposed a technique to enable the accurate material decomposition by applying weighting factors for the dual-energy mammography based on a photon-counting detector using a Monte Carlo simulation tool. We also evaluated the contrast and noise of simulated breast images for validating the proposed technique. As a result, the contrast for a malignant tumor in the dual-energy weighted subtraction technique was 0.98 and 1.06 times similar than those in the general mammography and dual-energy subtraction techniques, respectively. However the contrast between malignant and benign tumors dramatically increased 13.54 times due to the low contrast of a benign tumor. Therefore, the proposed technique can increase the material decomposition accuracy for malignant tumor and improve the diagnostic accuracy of mammography.

Accuracy of Live Fluoroscopy to Detect Intravascular Injection During Lumbar Transforaminal Epidural Injections

  • Lee, Min-Hye;Yang, Kyung-Seung;Kim, Young-Hoon;Jung, Hyun-Do;Lim, Su-Jin;Moon, Dong-Eon
    • The Korean Journal of Pain
    • /
    • v.23 no.1
    • /
    • pp.18-23
    • /
    • 2010
  • Background: Complications following lumbar transforaminal epidural injection are frequently related to inadvertent vascular injection of corticosteroids. Several methods have been proposed to reduce the risk of vascular injection. The generally accepted technique during epidural steroid injection is intermittent fluoroscopy. In fact, this technique may miss vascular uptake due to rapid washout. Because of the fleeting appearance of vascular contrast patterns, live fluoroscopy is recommended during contrast injection. However, when vascular contrast patterns are overlapped by expected epidural patterns, it is hard to distinguish them even on live fluoroscopy. Methods: During 87 lumbar transforaminal epidural injections, dynamic contrast flows were observed under live fluoroscopy with using digital subtraction enhancement. Two dynamic fluoroscopy fluoroscopic images were saved from each injection. These injections were performed by five physicians with experience independently. Accuracy of live fluoroscopy was determined by comparing the interpretation of the digital subtraction fluoroscopic images. Results: Using digital subtraction guidance with contrast confirmation, the twenty cases of intravascular injection were found (the rate of incidence was 23%). There was no significant difference in incidence of intravascular injections based either on gender or diagnosis. Only five cases of intravascular injections were predicted with either flash or aspiration of blood (sensitivity = 25%). Under live fluoroscopic guidance with contrast confirmation to predict intravascular injection, twelve cases were predicted (sensitivity = 60%). Conclusions: This finding demonstrate that digital subtraction fluoroscopic imaging is superior to blood aspiration or live fluoroscopy in detecting intravascular injections with lumbar transforaminal epidural injection.

A comparison of subtracted images from dental subtraction programs (디지털공제프로그램간의 디지털공제영상 비교)

  • Han Won-Jeong
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.147-151
    • /
    • 2002
  • Purpose: To compare the standard deviation of gray levels on digital subtracted images obtained by different dental subtraction programs. Materials and Methods: Paired periapical films were taken at the lower premolar and molar areas of the phantoms involving human mandible. The bite registration group used Rinn XCP equipment and bite registration material, based on polyvinyl siloxane, for standardization. The no bite registration group used only Rinn XCP equipment. The periapical film images were digitized at 1200 dpi resolution and 256 gray levels by a flat bed scanner with transparency unit. Dental digital subtraction programs used for this study were Subtractor (Biomedisys Co., Korea) and Emago (Oral Diagnostic Systems, The Netherlands). To measure the similarities between the subtracted images, the standard deviations of the gray levels were obtained using a histogram of subtracted images, which were then analyzed statistically. Results: Subtracted images obtained by using the Emago program without manual selection of corresponding points showed the lowest standard deviation of gray levels (p<0.01). And the standard deviation of gray levels was lower in subtracted images in the group of a bite registration than in the group of no use of bite registration (p < 0.01). Conclusion: Digital radiographic subtraction without manual selection of reference points was found to be a convenient and superior method.

  • PDF

Extracting Blood Vessels through Similarity Analysis and Intensity Correction (유사도 분석과 명암 보정을 통한 혈관 추출)

  • Jang Seok-Woo
    • Journal of Internet Computing and Services
    • /
    • v.7 no.4
    • /
    • pp.33-43
    • /
    • 2006
  • This paper proposes a method to extract coronary arteries effectively in the angiography, In general. DSA(Digital Subtraction Angiography) is a well-established technique for the visualization of coronary arteries, DSA involves the subtraction of a mask image, an image of a heart before the injection of contrast medium, from a live image, However, this technique is sensitive to the movement of background and can cause wrong detection due to the variance of background intensity between two images. Therefore, this paper solves the structural problem resulted from background movement by selecting an image which has the least difference of movement through the similarity analysis of background texture, and it extracts only the blood vessels effectively through local intensity correction of the selected images, Experimental results show that the proposed method has the lower false-detection rate and higher accuracy rate than existing methods.

  • PDF

Music Generation from Motion of Fish based on Running Averaging Background Subtraction Method (이동평균 배경제거 기반의 물고기 모션 검출을 통한 음악 생성)

  • Yap, Wah-Seng;Cho, Dong-Chan;Kim, Whoi-Yul
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2011.05a
    • /
    • pp.415-416
    • /
    • 2011
  • This paper describes about a technique of generating music from the natural motion of fish which are detected via the running averaging background subtraction method. The motion of the fish will create musical notes on a background frame which will be analyzed and played by a music playing module that is proposed in this paper called "PhysicX". This module is also capable of interacting with the fishes. in the tank.

  • PDF

Speech Recognition in Noisy Environments using the NOise Spectrum Estimation based on the Histogram Technique (히스토그램 처리방법에 의한 잡음 스펙트럼 추정을 이용한 잡음환경에서의 음성인식)

  • Kwon, Young-Uk;Kim, Hyung-Soon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.5
    • /
    • pp.68-75
    • /
    • 1997
  • Spectral subtraction is widely-used preprocessing technique for speech recognition in additive noise environments, but it requires a good estimate of the noise power spectrum. In this paper, we employ the histogram technique for the estimation of noise spectrum. This technique has advantages over other noise estimation methods in that it does not requires speech/non-speech detection and can estimate slowly-varying noise spectra. According to the speaker-independent isolated word recognition in both colored Gaussian and car noise environments under various SNR conditions. Histogram-technique-based spectral subtraction method yields superier performance to the one with conventional noise estimation method using the spectral average of initial frames during non-speech period.

  • PDF

Digital subtraction angiography(DSA) of hepatic artery using selective catheterization technique in beagle dogs (비글견에서 선택적 카테터 삽관법을 이용한 간동맥의 디지털 감산 혈관조영술)

  • Chang, Dong-woo;Yun, Young-min;Kim, Bong-kyeong;Lee, Young-won;Yoon, Jung-hee;Kweon, Oh-kyeong;Seong, Je-kyung
    • Korean Journal of Veterinary Research
    • /
    • v.39 no.3
    • /
    • pp.665-671
    • /
    • 1999
  • The aim of this study was to establish selective hepatic artery catheterization technique through percutaneous femoral artery puncture and to offer digital subtraction angiography (DSA) of hepatic artery in beagle dogs. Percutaneous femoral artery puncture was performed with Sheldinger's method. Microferret$^{TM}$-18 Infusion catheter(William, Cook, Europe) was introduced into abdominal aorta. Then, under fluoroscopy, iopamidol 370(Bracco, Italy) was injected to identify celiac artery and 'J' shaped guide wire was introduced into celiac artery. Catheter could be introduced into celiac artery through guide wire. In this manner, catheter was located at the insertion of hepatic artery and DSA was performed. In DSA of beagle dogs, hepatic artery which was divided into lateral branch, right-medial branch, right-lateral branch of hepatic artery, cystic artery and gastroduodenal artery was opacified without superimposition of any other body structure and so was the parenchyme of liver afterward. In autopsy angiographic finding of resected liver, cystic artery, caudate branch, lateral branch, right-medial branch, right-lateral branch and quadrate branch of hepatic artery were identified. It was concluded that selective hepatic artery catheterization technique was a minimally invasive method that facillitated the approach of hepatic artery and DSA was an excellent tool to visualize the vessle of liver in dogs.

  • PDF

A Robust Background Subtraction Algorithm for Dynamic Scenes based on Multiple Interval Pixel Sampling (다중 구간 샘플링에 기반한 동적 배경 영상에 강건한 배경 제거 알고리즘)

  • Lee, Haeng-Ki;Choi, Young Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.2
    • /
    • pp.31-36
    • /
    • 2020
  • Most of the background subtraction algorithms show good performance in static scenes. In the case of dynamic scenes, they frequently cause false alarm to "temporal clutter", a repetitive motion within a certain area. In this paper, we propose a robust technique for the multiple interval pixel sampling (MIS) algorithm to handle highly dynamic scenes. An adaptive threshold scheme is used to suppress false alarms in low-confidence regions. We also utilize multiple background models in the foreground segmentation process to handle repetitive background movements. Experimental results revealed that our approach works well in handling various temporal clutters.

Confidence-based Background Subtraction Algorithm for Moving Cameras (움직이는 카메라를 위한 신뢰도 기반의 배경 제거 알고리즘)

  • Mun, Hyeok;Lee, Bok Ju;Choi, Young Kyu
    • Journal of the Semiconductor & Display Technology
    • /
    • v.16 no.4
    • /
    • pp.30-35
    • /
    • 2017
  • Moving object segmentation from a nonstationary camera is a difficult problem due to the motion of both camera and the object. In this paper, we propose a new confidence-based background subtraction technique from moving camera. The method is based on clustering of motion vectors and generating adaptive multi-homography from a pair of adjacent video frames. The main innovation concerns the use of confidence images for each foreground and background motion groups. Experimental results revealed that our confidence-based approach robustly detect moving targets in sequences taken by a freely moving camera.

  • PDF