• 제목/요약/키워드: Subtraction image

검색결과 276건 처리시간 0.023초

IMACIS-1을 이용한 위장관 종양의 방사면역신티그램 (Radioimmunoscintigraphy Using IMACIS-1 in Gastrointestinal Cancer)

  • 손형선;김춘열;박용휘
    • 대한핵의학회지
    • /
    • 제24권1호
    • /
    • pp.29-36
    • /
    • 1990
  • Most of the diagnostic methods currently used for the detection of neoplastic masses provide indirect evidence. To obtain greater specificity in the interpretation of neoplasias by in vivo methods, the immunological approach appears to be most promising. Two problems that interfered with progress in this field were the lack of tumor specific antigen and the lack of well-defined and reproducible antibodies. To improve the sensitivity and specificity of radioimmunoscintigraphy as a technique for tumor localization, the use of monoclonal antibodies, fragments of antibodies and single photon emission computerized tomography (SPECT) are reasonable. The obvious advantages of monoclonal antibodies are their homogeneity, their specificity for the immunizing antigen and the reaction with a single determinant-thus no large immunecomplexes with antigen are formed. Monoclonal antibody technique has recently provided an opportunity to reevaluate the role of nuclear medicine for the diagnosis of malignant diseases by using the immunological approach. Out first results by means of radioimmunoscintigraphy of CEA and CA 19-9 producing tumors using a cocktail of fragments F $(ab')_2$, of mocolonal antibodies to CA 19-9 and CEA labeled with $^{131}I$ (IMACIS-1) are reported. The aims of this investigation was to evaluate the role of immunoscintigraphy in patients with colorectal and other cancers for diagnosis of local recurrences and metastasis. This report contains results of the first 8 colorectal and pancreas cancer patients with the elevation of the level of serum CEA and/or CA 19-9. IMACIS-1 was injected intravenously during 30 minutes in 100 ml saline solution after skin test. Planar scintigrams were recorded 3, 5 and 7 days after the injection of the IMACIS-1. Anterior, lateral and posterior views of the liver as well as anterior and posterior views of the pelvis were obtained in each patients as an $^{131}I-antibody$ image. We were able to localize exactly the malignant process with the double-nuclide double-compound $^{99m}Tc\;^{131}I$ (Tc+l) scintigrams. In Tc & I double-nuclide scintigraphy, computer subtraction display provided more clear localization of the tumor. We compared the results of radioimmunoscintigraphy with CT, ultrasonograms, conventional scintigrams. The results were as follows: 1) The sensitivity and specificity of radioimmunoscintigraphy using the fragments $F(ab')_2$ of the cocktails of CEA and CA 19-9 monoclonal antibodies were 80% and 100% respectively. 2) Tumor detection rate was not proportionated to the level of serum tumor markets. 3) Second tracer technique was essential for tumor localization as an anatomic landmark using double-nuclide scintigraphy. 4) A slow infusion of the antibodies was necessary to prevent the formation of large immune complexes. 5) Tumor/non-tumor radioactivity was most elevated at 7 days delayed imaging. 6) Using planar scintigraphic technique of $^{131}I$ labeled monoclonal antibodies are possible for imaging most of the tumors.

  • PDF

Prior to Breast MRI Guidelines in Korea, Where Were We?

  • Hwang, Cheong Hoon;Rho, Miribi;Lee, Minah;Kim, Ga Ram;Park, Vivian Youngjean;Yoon, Jung Hyun;Kim, Min Jung
    • Investigative Magnetic Resonance Imaging
    • /
    • 제25권1호
    • /
    • pp.35-42
    • /
    • 2021
  • Purpose: To evaluate and analyze the adequacy of breast magnetic resonance imaging (MRI)s taken before publication of the 2018 recommendation in South Korea. Materials and Methods: We enrolled 87 cases of breast MRIs, from January 2010 to November 2013, taken at external hospitals in the study. Breast MRI protocol elements are divided into three categories based on the recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance: (1) Essential elements for breast MRI protocol; (2) Element to consider when evaluating imaging quality; and (3) Optional element for breast MRI protocol. Also, we divided enrolled cases into three groups based on their conducting locations -- (1) Primary hospitals, (2) Secondary hospitals, and (3) Tertiary hospitals-and analyzed them for the adequacy of imaging protocols based on the 2018 recommendation. We used a Chi-square test and Fisher's exact test to identify differences between categorical variables. Results: Over 98% of the criteria for 'essential elements for breast MRI protocol' were satisfied when compared with the 2018 Recommendation. Over 96% of the criteria for 'elements to consider when evaluating imaging quality' were also satisfied, except for the slice thickness (83.9%). Optional elements for breast MRI protocol were satisfied with various percentages. There were no statistically significant differences between groups of tertiary, secondary, and primary hospitals; however, 3 tesla of MRI (P = 0.04), subtraction image protocol (P = 0.032), and DWI protocol (P = 0.03) were used more frequently in the tertiary hospitals than in the others. Conclusion: We found that the categories of 'essential elements' and 'elements to consider when evaluating imaging quality' were satisfied at 98% and 96%, respectively, when compared with the 2018 Recommendation by the Breast Imaging Study Group of the Korean Society of Magnetic Resonance.

Early Restoration of Hypoperfusion Confirmed by Perfusion Magnetic Resonance Image after Emergency Superficial Temporal Artery to Middle Cerebral Artery Anastomosis

  • Eun, Jin;Park, Ik Seong
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권6호
    • /
    • pp.816-824
    • /
    • 2022
  • Objective : Emergency superficial temporal artery to middle cerebral artery (STA-MCA) anastomosis in patients with large vessel occlusion who fails mechanical thrombectomy or does not become an indication due to over the time window can be done as an alternative for blood flow restoration. The authors planned this study to quantitatively measure the degree of improvement in cerebral perfusion flow using perfusion magnetic resonance imaging (MRI) after bypass surgery and to find out what factors are related to the outcome of the bypass surgery. Methods : For a total of 107 patients who underwent emergent STA-MCA bypass surgery with large vessel occlusion, the National Institute of Health stroke scale (NIHSS), modified Rankin score (mRS), infarction volume, and hypoperfusion area volume was calculated, the duration between symptom onset and reperfusion time, occlusion site and infarction type were analyzed. After emergency STA-MCA bypass, hypoperfusion area volume at post-operative 7 days was calculated and analyzed compared with pre-operative hypoperfusion area volume. The factors affecting the improvement of mRS were analyzed. The clinical status of patients who underwent emergency bypass was investigated by mRS and NIHSS before and after surgery, and changes in infarct volume, extent, degree of collateral circulation, and hypoperfusion area volume were measured using MRI and digital subtraction angiography (DSA). Results : The preoperative infarction volume was median 10 mL and the hypoperfusion area volume was median 101 mL. NIHSS was a median of 8 points, and the last normal to operation time was a median of 60.7 hours. STA patency was fair in 97.1% of patients at 6 months follow-up DSA and recanalization of the occluded vessel was confirmed at 26.5% of patients. Infarction volume significantly influenced the improvement of mRS (p=0.010) but preoperative hypoperfusion volume was not significantly influenced (p=0.192), and the infarction type showed marginal significance (p=0.0508). Preoperative NIHSS, initial mRS, occlusion vessel type, and last normal to operation time did not influence the improvement of mRS (p=0.272, 0.941, 0.354, and 0.391). Conclusion : In a patient who had an acute cerebral infarction due to large vessel occlusion with large ischemic penumbra but was unable to perform mechanical thrombectomy, STA-MCA bypass could be performed. By using time-to-peak images of perfusion MRI, it is possible to quickly and easily confirm that the brain tissue at risk is preserved and that the ischemic penumbra is recovered to a normal blood flow state.

단일광자방출단층촬영 영상에서 산란 및 감쇠 보정에 위한 절대방사능 측정 (Improved Activity Estimation using Combined Scatter and Attenuation Correction in SPECT)

  • 이정림;최창운;임상무;홍성운
    • 대한핵의학회지
    • /
    • 제32권4호
    • /
    • pp.382-390
    • /
    • 1998
  • 목적 : 이 연구의 목적은 SPECT 영상의 감쇠와 산란 현상을 보정하고 실제 임상 환경에서 상용하는 영상과 비교하여 그 효과를 평가하는 것이다. 그리고, 정확도가 개선된 영상에서 방사능양을 도출하여 SPECT 영상의 절대적인 정량화를 검증하는 것이다. 대상 및 방법: 직경이 20.0 cm인 원통형 팬톰에 삽입물로써 체적 25 ml의 폴리에틸렌 병을 6개 배치하고 배후와 다양한 비율을 이루도록 Tc-99m을 주입하였다. SPECT 기기로는 Trionix Triad xlt 20을 사용하였고 광피크 윈도 $126{\sim}154keV$, 산란 윈도 $101{\sim}123keV$에서 데이터를 얻었다. 이중에너지윈도(DEW) 방법과 Chang 방법을 사용하여 산란 및 감쇠 효과를 보정한 영상(SC+AC), 임상적으로 통용되고 있는 Chang 방법만을 사용하여 감쇠 효과를 보정한 영상(AC), 보정을 거치지 않은 영상(NONE)을 얻었다. SPECT 영상을 정량적으로 분석하기 위해 삽입물 대 배후의 방사능비(T/B), 영상대비, 절대방사능을 구하여 참값과 비교하였다. 결과: 관심영역 분석을 통한 T/B는 참값에 대하여 SC+AC 영상은 $1{\sim}20%$의 차이를 보였고 AC의 $24{\sim}37%$와 NONE의 $12{\sim}32%$에 비하여 개선되었다. 또한 SC+AC에서 영상 대비는 참값 1에 대하여 0.92로써 AC의 0.77, NONE의 0,80에 비하여 향상되었다. SPECT 영상에서 얻은 절대방사능 값은 SC+AC 영상이 참값에 대하여 $1{\sim}11%$의 오차를 나타냈으나, AC의 $22{\sim}47%$, NONE의 $2{\sim}16%$에 비하여 정확하였다. 그리고 대상물이 10.0 cm의 심부에 있을 때 절대방사능 값은 SC+AC에서 24%의 감소, AC에서 10%의 증가, NONE에서 40%의 감소를 보였다. 결론: 이 연구에서 사용한 DEW와 Chang방법에 의한 산란 및 감쇠 보정은 임상에 쉽게 적용할 수 있으며, 삽입물 대 배후의 방사능비와 영상 대비를 개선하였고 절대방사능을 정확하게 산출할 수 있었다.

  • PDF

뇌동맥류파열에 의한 지주막하 출혈환자의 예후평가에 있어서 아세타졸아미드 부하 뇌혈류 SPECT의 유용성 (Utility of Acetazolamide-Enhanced Brain Perfusion SPECT in Predicting Outcome of the Patients with Aneurysmal Subarachnoid Hemorrhage)

  • 최윤영;김재민;김광명;최일승;조석신
    • 대한핵의학회지
    • /
    • 제35권4호
    • /
    • pp.241-250
    • /
    • 2001
  • 목적: 뇌동맥류파열에 의한 지주막하출혈에 동반되는 뇌혈관수축에 따른 뇌허혈 상태는 환자의 예후에 영향을 미치게 되므로 조기에 진단, 치료하는 것이 중요하다. 본 연구에서는 뇌동맥류파열에 의한 지주막하출혈 환자에서 기저/아세타졸아미드 부하 뇌혈류 SEPCT에서의 혈관예비능 유지여부가 환자의 예후를 예측하는데 도움이 되는지 알아보고자 하였다. 대상 및 방법: 대뇌동맥류 파열에 의한 지주막하출혈이 있는 환자 21명을 대상으로 하였다. CT와 뇌혈관촬영으로 혈관수축여부를 진단하였으며, 기저/아세타졸아미드 부하 Tc-99m ECD SPECT로 혈관예비능 감소 유무를 평가하였고 GOS (glasgow outcome scale)로 임상경과를 평가하였다. 혈류예비능 감소와 혈관수축의 상관 관계를 알아보고, 혈류예비능감소, 혈관수축, 기저 SPECT의 혈류결손과 Hunt-Hess 등급, CT상 지주막하 출혈량, GOS등급과의 관계를 Fishers exact test로 분석하였다. 결과: 기저 SPECT에서 혈류결손은 81% (17/21)에서 관찰되었으며, 아세타졸아미드 투여 SEPCT에서 혈관예비능 감소는 38% (8/21)에서 관찰되었고, 혈관수축도 38% (8/21)에서 관찰되었다. 혈관예비능은 임상경과(GOS로 평가)가 양호한 군에서 유지되었고(92%,12/13) 불량한 군에서 감소되어(62.5%, 5/8) (p=0.014), 환자의 임상경과를 잘 반영하였다. 또한 혈관예비능 감소군에서 지주막하출혈정도가 심하였으며(p=0.017), Hunt-Hess 등급도 불량하였다(p=0.041). 혈관예비능과 혈관수축의 상관관계를 보면 서로 일치하는 경우가 71% (15/21)였으며, 혈관수축이 없이 혈관예비능이 감소된 경우가 23% (3/13), 혈관수축을 보이면서 혈관예비능이 유지되어 있는 경우가 8예 중 3예에서 관찰되었는데 환자들의 임상결과는 혈관예비능 보존유무와 일치하였다. 결론: 혈관촬영으로 진단한 뇌혈관수축은 실제 뇌혈류못하였고 기저/아세타졸아미드 부하 뇌혈류 SPECT는 뇌의 기능과 혈류 및 뇌혈관예비능을 평가함으로써 뇌동맥류파열에 의한 지주막하출혈 환자의 예후를 예측하는데 유용한 검사라고 생각된다.

  • PDF

게이트 심장 혈액풀 스캔에서 좌전사위상 각도의 변화에 따른 정량적 지표 비교 (The Comparison of Quantitative Indices by Changing an Angle of LAO View in Multi-Gated Cardiac Blood Pool Scan)

  • 윤순상;남기표;류재광;김성환
    • 핵의학기술
    • /
    • 제16권1호
    • /
    • pp.57-61
    • /
    • 2012
  • 게이트 심장 혈액풀 스캔(Gated cardiac blood pool scan, MUGA)은 좌심실의 기능을 평가하는 데 유용한 검사로 심근독성 항암제를 투여 받는 환자에서 심박출 계수(Ejection Fraction, EF)를 추적, 감시하는데 이용되어 많은 검사가 시행되고 있다. EF를 산출하기 위해 좌전사위상(Left Anterior Oblique, LAO)에서 좌우 심실이 분리되도록 각도를 조절해야 하는데 이때 LAO 각도의 설정은 정량분석 값에 영향을 미칠 가능성이 있어, 이에 본 연구는 LAO 각도의 변화가 정량분석 값에 영향을 미치는지 살펴보고자 한다. 2011년 06월부터 09월까지 본원에서 MUGA 검사를 시행한 환자 49명(남 8명, 여 41명)을 대상으로 하였다. 먼저 최적 중격상(Best septal view)으로 촬영 후, 전면과 측면 측으로 LAO 각도를 가감하여 총 3회 촬영하였다. ${\pm}5^{\circ}$로 환자 20명, ${\pm}10^{\circ}$로 29명을 촬영하였고, 관심영역을 자동 및 수동으로 각각 설정하여 좌심실의 EF와 확장기말계수, 수축기말계수를 비교하였다. 먼저 관심영역을 자동으로 분석하였을 때, ${\pm}5^{\circ}$의 경우, LAO, LAO $-5^{\circ}$, LAO $+5^{\circ}$에서의 EF의 평균값은 각각 $61.0{\pm}7.5%$, $62.1{\pm}7.1%$, $60.9{\pm}6.7%$ ($p$=0.841)이었고, 이때의 확장기말계수, 수축기말계수 역시 통계적으로 유의한 차이가 없었다($p$<0.05). ${\pm}10^{\circ}$의 경우, EF의 평균값은 각각 $62.4{\pm}9.54%$, $62.3{\pm}10.8%$, $61.6{\pm}9.3%$ ($p$=0.938)이었고, 이때의 확장기말계수, 수축기말계수 역시 통계적으로 유의한 차이가 없었다($p$<0.05). 또한 관심영역을 수동으로 분석하였을 때, ${\pm}5^{\circ}$의 경우, EF의 평균값은 각각 $62.8{\pm}7.1%$, $63.6{\pm}7.5%$, $62.7{\pm}7.3%$ ($p$=0.903)이었고, 이때의 확장기말계수, 수축기말계수 역시 통계적으로 유의한 차이가 없었다($p$<0.05). ${\pm}10^{\circ}$의 경우, EF의 평균값은 각각 $65.5{\pm}9.0%$, $66.3{\pm}8.7%$, $63.5{\pm}9.3%$ ($p$=0.473)이었고, 이때의 확장기말계수, 수축기말계수 역시 통계적으로 유의한 차이가 없었다($p$<0.05). 최적 중격상을 기준으로 하였을 경우, ${\pm}5{\sim}10^{\circ}$의 영상의 차이는 EF에 유의한 변화를 주지 않을 것으로 판단된다. 다만 최적 중격상에서 벗어난 영상은 좌심실의 벽 운동 등과 같은 심장의 운동상태를 정성적으로 평가함에 있어서 판독자에 따라 편차가 발생할 수 있으므로 주의해야 할 것이다.

  • PDF