The Seismic Analysis of 72.5kV Gas Insulated Switchgear(GIS) (72.5kV 가스절연차단기(Gas Insulated Switchgear)의 내진해석)

  • Lee, S.H.;Cho, S.S.;Kang, S.M.;Ahn, K.Y.;Bang, J.D.;Min, K.S.;Choi, J.W.;Yoon, S.S.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.762-764
    • /
    • 2001
  • In order to evaluate the structural safety from an earthquake, the seismic analysis of large structures such as GIS in electric power substations and equipments for nuclear power plant has been carried out because the seismic qualification by experiment is very expensive. This paper presents the seismic analysis of the 72.5kV GIS produced by LGIS. The finite element model of the GIS is developed and analyzed using ANSYS. The model consists of beam elements for the enclosures and mass elements for the conductors and the mechanisms. Using the transient analysis under seismic load, the structural safety is verified.

  • PDF

The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition (일체형 주상용 몰드 변압기의 덕트에 따른 열해석 특성 연구)

  • 조한구;이운용;박영두
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.3
    • /
    • pp.348-352
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and ow loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

Performance verification and test for substation automation system (변전자동화 시스템 성능검증 및 실증시험)

  • Jang, B.T.;Choi, C.Y.;Kim, B.H.;Park, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.258-259
    • /
    • 2006
  • 국내외적으로 전력산업분야의 가장 큰 화두중 하나는 변전소 단위의 디지털화이며 특히 국외에서는 국제표준 변전자동화 시스템 연구와 제품개발 등에 인력을 집중 투자하고 있다. 국제적으로 지금까지 축적된 변전소 관련 제반 기술력 및 경험 둥을 바탕으로 전 세계적으로 단일화시키고 표준화된 변전소 자동화 규격인 IEC 61850 (Communication networks and systems in substations) 규격이 제정되었으며 따라서 향후 전력 관련 기업은 시스템 엔지니어링 기술, 전력기기 공급능력, 유지/보수/운영기술 등을 종합적으로 보유하고 자산 및 위험관리를 종합적으로 제공할 수 있어야만 세계시장에서 생존할 수 있다. 또한 전력기기를 수출하는 국내업체는 향후 IEC(International Electrotechnical Commission) 등 국제표준에 따른 전력설비를 개발하지 않으면 수출경쟁력을 잃게 될 것이다. 이러한 세계화 추세에 발맞추어 한국전력공사와 관련 업체들은 공동으로 2005년 10월부터 6년의 기간으로 "디지털 기술기반의 변전소 자동화 시스템 개발" 사업을 진행 중에 있으며 특히 한국전력공사는 변전자동화 시스템의 성능검증 및 실증시험 절차를 구축하기 위한 과제를 수행 중이다.

  • PDF

A Study for Fault Location Scheme Using the 9-Conductor Modeling of Korean Electric Railway System (9도체 전기철도 모델링을 이용한 고장점 표정 방안 연구)

  • Lee, Han-Sang;Lee, Chang-Mu;Lee, Han-Min;Jang, Gil-Soo;Chang, Sang-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2006.11a
    • /
    • pp.411-413
    • /
    • 2006
  • This paper presents a novel fault location scheme on Korean AC electric railway systems. On AC railway system, because there is a long distance, 40 km or longer, between two railway substations, a fault location technique is very important. Since the fault current flows through the catenary system, the catenary system must be modeled exactly to analyze fault current magnitude and fault location. In this paper, before suggestion for the novel scheme of fault location, a 9-conductor modeling technique that includes boost wires and impedance bonds is introduced, based on the characteristics of Korean AC electric railway. After obtaining a 9-conductor modeling, the railway system is constructed for computer simulation by using PSCAD/EMTDC. By case studies, we can verify superiority of a new fault location scheme and suggest a powerful model for fault analysis on electric railway systems.

  • PDF

The Experimental Study on Seismic Capacity of 154 kV & 345 kV Main Transformer Bushings (154 kV 및 345 kV 주변압기 부싱의 내진성능 시험 연구)

  • Hwang, Kyeong Min;Ham, Kyung Won;Kim, Gyeong Hwan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.2
    • /
    • pp.87-94
    • /
    • 2018
  • In this study, seismic performance of bushings and their connection parts was analyzed by performing shaking table tests for various types of bushings widely used as auxiliary equipment of main transformers in domestic substations. As a result of the seismic tests of five types of 154 kV bushings according to the manufacturers, all the bushings secured the structural integrity even at the acceleration of 1.4 g and it was found that leakage of insulating oil didn't occur. Also, the average acceleration amplification rate at the upper part of the bushings was about 2.5 to 3.0 times higher than the lower one. On the other hand, when a representative 345 kV bushing was subjected to the seismic test, the structural integrity was secured even at 1.0 g acceleration similar to the design earthquake load level, but in this test, leakage of insulating oil occurred. However, when a stiffener restricting the connection of the bushing is installed in the same 345 kV bushing, the displacement of the bushing connection is controlled and the stiffener prevent the oil from leaking even at the acceleration of the designed seismic level.

Future New Distribution System with Low voltage and Mass Capacity using HTS equipments (초전도기기를 적용한 미래 저압대용량 신 배전계통)

  • Yoon Jae Young;Kim Jong Yul;Lee Seung Ryul
    • Progress in Superconductivity and Cryogenics
    • /
    • v.7 no.1
    • /
    • pp.37-41
    • /
    • 2005
  • This paper describes the construction scheme of new distribution system using HTS(High Temperature Superconducting) power equipments such as cable, transformer and FCL(fault current limiter). At present, one of the most serious problems in distribution power system, especially for metropolitan complex city, is to obtain the ROW for cable line routes, space for downtown substations and satisfy the environmental protection caused by NIMBY phenomena. Unfortunately, it is expected that this situation will get more and more worse. As the HTS technology to apply in power system Is developed, HTS cable utilizing mass-capacity characteristic can be a useful countermeasure to overcome this problem. This paper describes the application methodology of 22.9kV HTS cable with low-voltage, mass-capacity characteristics replacing the 154kV conventional cable. By applying 22.9kV HTS cable, the HTS transformer with higher capacity for the reduction of space and transformer numbers of downtown substation is necessary. Also, if the leakage Impedance of HTS transformer is same as or lower than that of conventional transformer, the fault current of 22.9kV bus will increase because the HTS transformer capacity is larger than that of the conventional transformer. This means the parallel application of HTS-FCL to reduce the fault current in addition to the HTS cable and transformer can be necessary. With the basic construction scheme of new distribution system, this paper describes the future study points to realize this new distribution system using HTS equipments.

Study on the Criterion and Algorithm for On-line Dissolved Gas of a Power Transformer (전력용 변압기 온라인 유중가스 진단기준치 및 알고리즘에 관한 연구)

  • Kweon Dongjin;Kwak Joosik;Kwak Heero;Kim Jaechul;Chin Sunbm
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.5
    • /
    • pp.206-212
    • /
    • 2005
  • In this paper, criterion and algorithm for on-line dissolved gas of a Power transformer are studied. For the initial diagnosis of a power transformer, the on-line dissolved gas analysis is one of the most important and acceptable item to preventively diagnose a power transformer. But the criterion and algorithm of this item are not established yet in korea. In this paper, criterion and alarm level of the on-line dissolved gas analysis are based on the analysis of on-line data of operating transformers, Korea industrial standard and operation manual for a power transformer as well as accumulated data of the preventive diagnosis systems which have been operated at nine substations of Korea Electric Power Co.(KEPCO) since 1997, Therefore, the criterion and alarm level proposed in this paper are to be well suitable and are adaptable for the domestic operational environments and conditions of the power transformer. Considering that the conventional diagnosis system is capable only of accumulating and monitoring data of the power transformer operation, the criteria and the algorithms make it possible to accomplish an ultimate goal of the preventive diagnosis system. It is expected, therefore, that they will have a beneficial effect on broad applications of the preventive diagnosis system and the achievement of manless substation system in the future.

Temperature Rise Test and Temperature Distribution Analysis of Pole Mount Mold Transformer with One-body Molding (일체형 주상용 몰드 변압기의 온도분포 및 특성 비교)

  • Cho, Han-Goo;Lee, Un-Yong;Kang, Tack-Sou;Choi, In-Hyuk
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.12
    • /
    • pp.1154-1159
    • /
    • 2006
  • The mold transformers have been widely used in underground substations of large building and have some advantages when compared with oil-transformer. Those advantages are low fire risk, environmental compatibility, compact size and high reliability. The mold transformer is generally known to have cooling duct between low voltage and high voltage coil. To achieve better compact structure and low loss, mold transformers made by one body molding method has been developed. Nevertheless, such kinds of transformer need better cooling method because heat radiation between each winding is still of problem. The life of transformer is significantly dependent on the thermal behavior in windings. Many designers have calculated temperature distribution in transformers and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, the temperature distribution analysis of 100 kVA pole mold transformer for power distribution were investigated by FEM program and the thermal analysis results were compared with temperature rise test.

Development of a Digital System for Protection and Control of a Substation Part 2 - Development of Fiber Optic Network (변전소의 보호.제어를 위한 디지탈 시스템 개발 PART 2 - 광 통신망 개발)

  • Kwon, W.H.;Park, S.H.;Kim, M.J.;Lee, Y.I.;Park, H.K.;Moon, Y.S.;Yoon, M.C.;Kim, I.D.;Lee, J.H.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.362-364
    • /
    • 1992
  • In this paper, the development of a fiber optic network for an integrated digital protection relay system is described. The structure of the developed network is determined to loosen the optic requirements and to have good extensibility while providing sufficient functions for protection and control for substations. The network has a hierarchical structure with two levels. The upper level handles data for monitoring and control of the system with star topology. The lower level manages the real time data for bus protection with one-to-one connections. Communication flows of each level are described. The HDLC is employed as the network protocol.

  • PDF

Experimental Study on the Dynamic Characteristics of Porcelain Surge Arrestor Considering the Variation of Cable's Tension and Arrestor's Stiffness (케이블 장력 및 피뢰기의 강성 변화를 고려한 애자형 피뢰기의 동특성 시험 연구)

  • Jang, Jung Bum;Hwang, Kyeong Min;Yun, Kwan Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.18 no.5
    • /
    • pp.253-259
    • /
    • 2014
  • Porcelain surge arrestor is very vulnerable to earthquake but there is very few information on its dynamic characteristics which are necessary to the seismic design. Therefore, the dynamic characteristics of the porcelain surge arrestor are evaluated considering the variation of its cable tension and stiffness by shaking table test. The test results show that the first natural frequencies are 5.3 Hz and 5.2 Hz in the horizontal x- and y-axis directions, respectively, and higher than 30 Hz in the vertical z-axis direction, respectively. The installation of cable on the surge arrestor reduces the horizontal natural frequencies due to the constraint effect of the cable but cable tension has no effect on the natural frequency. Also, the natural frequency is proportional to the stiffness of the surge arrestor. This test result will be used for the seismic design and seismic capacity assessment of domestic substations and contribute to the stability of the electric power supply under earthquake event.