• Title/Summary/Keyword: Submerged Module

검색결과 50건 처리시간 0.03초

침지형 막모듈에서 중공사 분산에 따른 여과특성 (Filtration Characteristics according to Hollow Fiber Dispersion in Submerged Membrane Module)

  • 이재인;신춘환
    • 한국환경과학회지
    • /
    • 제9권2호
    • /
    • pp.173-176
    • /
    • 2000
  • This study was carried out to investigate the filtration characteristics of membrane modules according to hollow fiber dispersion for direct solid-liquid separation of activated sludge. 2 bundle, 4 bundle, and 10 bundle, and 10 bundle module used in this experiment according to hollow fiber dispersion was manufactured at laboratory and permeate flux and transmembrane pressure(TMP) of each module were observed under a suction pressure of 0.5kgf/c$m^2$. As the hollow fibers were dispersed, permeate flux was increased and TMP was decreased. Permeate flux and TMP of each module was 15.0 $\ell$/$m^2$.h and 31.8 cmHg for 2 bundle, 16.0 $\ell$/$m^2$ .h and 17.4 cmHg for 4 bundle, and 20.4 $\ell$/m2 .h and 31.8 cmHg for 10 bundle. In conclusion, the membrane fouling is expected to be decrease by maintaining lower TMP with hollow fiber dispersion.

  • PDF

600L급 LNG 차량 연료공급용 초저온 액중펌프 국산화개발에 관한 연구 (A Study of the Localization Development of Cryogenic Submerged Pump for the Fuel Supply system of 600-Liter-Grade LNG Vehicles)

  • 김용길;김도현;이원영;이중섭
    • 한국기계가공학회지
    • /
    • 제20권4호
    • /
    • pp.113-118
    • /
    • 2021
  • In this study, localized development of a submerged cryogenic pump for use in LNG containers is conducted with large-sized commercial vehicles as the target. The submerged pump installed in an LNG storage container is the key module that supplies fuel to the engine through the reciprocating motion of a piston. Research and development on 660-L fuel containers is performed herein. The target is to achieve a mileage of 600 km or more by applying it to major NGV vehicles worldwide. In this manner, the present study aims to verify the operating mechanisms of the major parts of currently advanced products through reverse engineering in the early development process and draw basic design data.

Pilot Scale Plant의 황 충진 MBR을 이용한 고효율의 질소제거 공법 개발 (Development of High-rate Nitrogen Removal Process Using Submerged MBR Packed with Granular Sulfur of Pilot Scale Plant)

  • 문진영;황용우;조현정
    • 상하수도학회지
    • /
    • 제25권3호
    • /
    • pp.383-390
    • /
    • 2011
  • In this study, a process combined biofiltration with sulfur-utilizing autotrophic denitrification and membrane separation was proposed to examine the efficiency of nitrogen removal. As an experimental device, hollow-fiber module was installed in the center of reactor to generate the flux forward sulfur layer in the cylinder packed with granular sulfur. In addition, a simple module was installed in activated sludge aeration tank which inside and outside of sulfur-using denitrification module was covered with microfilter and the module was considered as an alternative of clarifier. The experiment for developing new MBR process was carried out for three years totally. As the results of first two-year experiment, successful nitrogen removal performance was revealed with lab-scale test and pliot scale plant using artificial wastewater and actual plating wastewater. In this year, pilot scale test using actual domestic wastewater was performed to prove field applicability. As the results, high-rate nitrogen removal performance was confirmed with about 0.19 kg ${NO_3}^--N/m^3$ day of rate. Also significant fouling and pressure increase were not found during the experiment. And, the production ratio of sulfate and the consumption ratio of alkalinity showed a slightly higher value about 311 mg ${SO_4}^{2-}/L$ and 369 mg $CaCO_3$/L, respectively. In conclusion, the developed MBR process can be utilized as an alternative for retrofiting existing wastewater plants as well as new construction of advanced sewage wastewater treatment plants, with cost-effective merit.

IPA 수용액으로부터 수분제거를 위한 침지형 모듈 제조와 투과증발 특성 (Pervaporation Performance of Submerged Type Membrane for the Separation of Water from Aqueous Isopropanol Solution)

  • 우승문;박윤환;남상용
    • 멤브레인
    • /
    • 제28권4호
    • /
    • pp.279-285
    • /
    • 2018
  • 이소프로필알코올/물 혼합물은 가교된 폴리비닐알코올 복합막을 이용하여 투과특성평을 알아보았다. 검화도가 다른 3종 PVA를 이용하여 고분자의 농도와 GA 농도에 따라서 투과특성을 확인하였다. 복합막은 PVA 용액을 PAN 지지체 위에 캐스팅한 후, 열가교를 통해 제조하였다. PVA 농도가 증가할수록 투과도는 감소하지만 선택도는 증가하는 것을 확인하였다. PVA-3이 7 wt% 농도로 코팅된 복합막에서 $209g/m^2h$의 투과도를 가지고, 100 이상의 선택도를 가지는 것을 확인하였다. 침지형 분리막을 제조하여 feed tank 온도와 feed 용액의 IPA 농도에 따라서 투과실험을 확인하였다. 또한 IPA 수용액에 농축실험을 지속적으로 한 결과, 60시간 후에 IPA의 농도가 99%까지 증가하는 것을 확인하였다.

부등류해석을 이용한 QUAL2E 모형의 개선 (Improvement of QUAL2E Model using Nonuniform Flow Analysis)

  • 김상호;최현상
    • 한국물환경학회지
    • /
    • 제22권6호
    • /
    • pp.1144-1150
    • /
    • 2006
  • Recently, as water pollution accidents in rivers have increased, there is an increased interest in water quality forecast with accurate simulation. QUAL2E model, widely used for water quality analysis, uses the same hydraulic characteristics, such as depth and velocity, in a reach. The flow of the river is changed by various hydraulic constructions or by topography in a real river channel. In this study, a hydraulic connection module is developed to consider flow variations of river channels in QUAL2E model. The module uses the simulations results of non-uniform flow of a 1-D hydraulic model such as DWOPER or HEC-RAS. The improved QUAL2E model with this module was applied to a downstream section of Paldang Dam on the Han River. The results show the variation of water quality very well in a reach where flowing vary abruptly, like the Jamsil submerged weir.

MBR 공정에서 간헐공기주입에 따른 겔층 제거 메커니즘 (Mechanism of Gel Layer Removal for Intermittent Aeration in the MBR Process)

  • 노수홍;최영근;권오성;박희성
    • 멤브레인
    • /
    • 제16권3호
    • /
    • pp.188-195
    • /
    • 2006
  • 본 연구의 목적은 침지형(YEF 750D-2) 모듈을 적용하여 공기유량에 따른 유체 유속과 간헐적인 세정공기의 공급에 의한 오염제거를 평가하는 것이다. 공기유량에 따라 모듈의 유체 유속은 선형적으로 증가하였으며, MLSS의 농도가 1,000 mg/L 증가할 때 마다 $3\times10^{-4}m{\cdot}min/sec{\cdot}L$의 비율로 유체 유속이 감소하였다. 세정공기의 공급이 정지되는 시간에 전여과가 일어나 흡인여과 시간 동안 겔층 위에 케익층이 형성되었다. 20초 정지와 20초 공기공급의 간헐공기주입으로 형성된 케익층이 역세정에 의하여 제거되면서 압력증가율이 가장 낮게 나타났다. 겔층이 제거되는 메커니즘은 세정 공기공급을 교대로 하여 겔층 위에 케익층을 형성시켜 케익층이 제거될 때 겔층이 함께 제거되는 원리로 설명할 수 있다.

간접포기식 침지여상의 장류 폐수처리특성에 관한 연구 (A Study on the Characteristics of the Soysauce Wastewater Treatment in Aerobic Submerged Biofilter)

  • 권영호;원찬희;신승원
    • 한국환경과학회지
    • /
    • 제7권5호
    • /
    • pp.679-685
    • /
    • 1998
  • The Soysauce wastewater removal characteristics of submerged biofilters filled with two filter media respectively were experimentally examined with constant temperature, pH value and variable BOD loading and recirculation ratio. The decreasing order of BOD removal is Netring(random plastic media), cubic wire meshes(plastic module). This is mainly due to the media characteristics such as void ratio, specific surface area and media shapes. The BOD removal ratio decreases with increasing $BOD_5$/ volumetric loading rate, and the loading rate for the BOD removal over 85% is lower than 1.5kg$BOD_5$ 5/$m^3$d for the plastic media of Netring and cubic wire meshes. The $BOD_5$ removal rate increases with the recirculation ratio, but the rate of increase become smaller as the recirculation ratio increases over 20. When $BOD_5$ volumetric loading is 1.5kg$BOD_5$/$m^3$d, the required recirculation ratio to obtain 85% BOD$_{5}$ removal is about 20 for Netring and it was about 30 for cubic wire meshes.s.

  • PDF

Numerical Analysis on Deformation of Submerged Structures using 2-Dimensional VOF-DEM Model

  • Kim, Mi-Kum;Kim, Chang-Je
    • 한국항해항만학회지
    • /
    • 제31권9호
    • /
    • pp.785-791
    • /
    • 2007
  • In this paper we proposed a model that the deformation of the submerged rubble mound breakwaters composed with materials of various size, induced by wave action, can be computed. The water particle kinematics by waves in porous mound structure are computed by CADMAS-SURF, then the deformation of structure is computed using DEM module. To investigate the interaction of wave and sectional deformation of structures, analysis is accomplished by two steps. Analysis at the first step is executed with incipient mound. And analysis at the second step is executed with deformed mound by wave action. Furthermore, behaviors of materials are influenced by various properties such as the contact stiffness and the friction angle. Therefore, in order to present the behavior of the element caused by various properties, computations are accomplished with random coefficients by using the Monte Carlo simulation.

음식물 소멸기에서 발생하는 응축폐수의 Polyethylene 침지형 중공사막을 이용한 처리 특성 (Processing Characteristics of the Condensed Wastewater Resulting from Food Waste Disposal using a Submerged Polyethylene Hollow Fiber Membrane)

  • 유재상;전태봉;김진호;정건용
    • 멤브레인
    • /
    • 제20권2호
    • /
    • pp.127-134
    • /
    • 2010
  • 연구는 음식물 쓰레기를 음식물 소멸기에서 미생물에 의해 발효하여 유기물을 감량화하고, 음식물 발효시 발생되는 가스를 냉각기에서 기체와 수분으로 분리하여 기체는 반응기로 다시 보내고 수분은 응축하여 침지식 MF 중공사 분리막이 장착된 MBR 시스템에 적용하여 처리하는 시스템에 관한 연구이다. (주)바이오하이테크에서 제작한 음식물 소멸기와 수처리 장치에 침지식 MF 중공사 모듈을 설치하여 90일간 H연구소 직원식당에서 발생되는 음식물 쓰레기를 연속 투입하여 처리하였다. 음식물 소멸기 초기 Seeding를 위하여 수분조절제로 미강, 왕겨, 톱밥을 305 kg 투입하였고 음식물은 운전기간동안 1,648 kg투입하였고 응축폐수는 1,600 L 발생되었다. 음식물 소멸기 운전 종료 후 배출된 발효 부산물은 386 kg으로 감량율은 약 80%로 조사되었다. 침지식 MF 중공사 분리막 모듈을 응축폐수의 MBR 시스템에 적용하여 유기물 처리한 결과 제거율은 각각 BOD 99.9%, COD 97.5%, SS 98.6%, T-N 54.6%, T-P 34.7%였으며, 총대장균은 100%가 제거되었다.

Factors Affecting Biofouling in Membrane Coupled Sequencing Batch Reactor

  • Lee, Chung-Hak
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 2003년도 The 4th Korea-Italy Workshop
    • /
    • pp.7-10
    • /
    • 2003
  • Factors affecting filtration performance were investigated in a Sequencing Batch Reactor (SBR) coupled with a submerged microfiltration module. Special bioreactors for aerobic and anoxic phases, respectively, were specifically designed in order to differentiate tile effect of Dissolved oxygen (DO) from that of mixing intensity on membrane filterability. DO concentration as well as mixing intensity proved to have a major influence on the membrane performance regardless of the SBR phase. A higher DO concentration resulted in a slower rise in TMP, corresponding to less membrane fouling.

  • PDF