• Title/Summary/Keyword: Subjective Rating

Search Result 322, Processing Time 0.024 seconds

Comparative Evaluation of Clothing Pressure and Subjective Sensation Exerted by Foundation (파운데이션 착용으로 인한 의복압과 주관적 감각의 비교 평가)

  • Jeong, Jeong-Rim;Kim, Hee-Eun
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.30 no.11 s.158
    • /
    • pp.1531-1537
    • /
    • 2006
  • This study was conducted to investigate the relation between clothing pressure and subjective sensation exerted by foundation. Nineteen females volunteered as subjects. Experimental foundations were brassiere with 70B, 70C, 75B and 75C size which were widely distributed in pilot test and two types of girdle of which size were 64, 70 and 76. Clothing pressure with an air pack system and subjective sensation were measured at 5 points in brassiere and 7 points in the girdle. As the result of this study, brassiere's band and girdle's waist line, of which clothing pressure are high, is needed to improve. Generally the more pressure makes the more tightness, however, in some regions more or less pressure can give comfort. The tightness rating may not only related to clothing pressure, but also related to factors such as body size, body fat, resilience of muscle and bone structure. Other subjective sensation such as tactile feeling, hot/wet feeling, etc. in addition to the study with consideration of these factors could be used in future research to evaluate the effectiveness of foundation.

Sound Quality Characteristics of Refrigerator Noise in Real Living Environments (주거환경에서 냉장고 소음의 음질 특성)

  • You, Jin;Chang, Ho-Yeon;Lee, Chung-Hwa;Jeong, Jeong-Ho;Jeon, Jin-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.8 s.113
    • /
    • pp.797-805
    • /
    • 2006
  • The sound quality characteristics of refrigerator noise in an anechoic chamber and in a real living environment for 30 models of refrigerators were investigated. Subjective evaluation experiments were conducted to determine subjective tolerance level for refrigerator noise. Refrigerator noise was played from a loudspeaker at the position normally occupied by a refrigerator in a real living environment. A nine-point scale was used to measure subjective satisfaction of the sound pressure levels for refrigerator noise. Point 3 on the scale corresponded to a sound pressure level of about 30 dB(A). Seventy percent of the participants were satisfied with this level of refrigerator noise. A semantic differential test was also conducted to evaluate the sound quality of refrigerator noise. From the results of correlation and multiple regression analyses on the psychoacoustical parameters and subjective evaluations of 30 refrigerators, sound quality indices which predict the subjective rating score were proposed.

The Evaluation of the Road Noise of the Automotive Tire by Subjective Test (주관적인 시험에 의한 자동차 타이어 도로소음 평가)

  • Lee, Tae-Keun;Kim, Byoung-Sam;Cho, Tae-Jea
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.17 no.6
    • /
    • pp.91-96
    • /
    • 2008
  • As a remarkable reduction of the vehicle noise, the important of tire noise which is generated from the vehicle and the necessity of the research for the noise reduction is being emphasized. In this study, the road noise which is excited by the interaction between tire and road has been studied. The subjective test(feeling test) according to SAE J1060 rating scale is applied to the evaluation of the road noise. The combination of the several tires and vehicles are made to consider the effect of the vehicle suspension and the tire structure for road noise. The vehicles with 3-different suspension system are applied to road noise test and the eight kinds of tires are selected. As the results, the effects of the vehicle suspension and tire structure which affects on road noise are investigated.

On the subjective response caused by impulse sounds produced by leisure shooting (레저용 사격 소음에 대한 주관적 반응)

  • Kim, Deuk-Sung;Chang, Seo-Il
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.714-720
    • /
    • 2008
  • This research presents a laboratory study about an subjective response of impulsive sound caused by leisure shooting. The sources are sampled from outdoor noise and their levels range from 40 to 75 dB at the interval of 5dB. The noise unit is based on A-weighted sound exposure level (ASEL; $L_{AE}$). To make equal ASEL of outdoor noise, finite impulse response (FIR) filter is applied to the originally sampled source to include the effect of distance attenuation. The evaluation method of the jury test adopted a Semantic Difference(SD) Method. In the result of the jury test for impulsive noise, the mean response rating expressed a linear relation and %HA(percent highly annoyed) displayed a exponential growth relation.

  • PDF

A Survey on the Korean Vocabulary for the Asscssment of Noise (소음평가를 위한 한국어 어휘 조사연구 1)

  • 정광용;한명호;김선우
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1997.04a
    • /
    • pp.370-375
    • /
    • 1997
  • The ratings of noise are consisted of physical factors and psychological factors. The physical factor means the scales and the spectrum characteristics of noise, on the other hand the psychological factor means the subjective emotion, sensation and individual judgement for it. Therefore the rating of noise must reflect the subjective psychology of people for it. But it is very difficult to establish an effective scale which can reflect well that because the subjective psychology has many variables according to the cultural differency, nationality and individual personalities. In this paper, Korean Vocabularys for the assessment of noise were surveyed in order to find out the effective noise scale for Korean.

  • PDF

Analysis of Physical Parameters for the Evaluation of HVAC Diffuser Noise (공기조화 취출구 소음 평가를 위한 물리지수 분석)

  • Park, Hyeon-Ku;Kim, Hang;Go, Seong-Seok;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.402-405
    • /
    • 2006
  • The diffuser noise of HVAC(heating ventilating and air-conditioning) uses dB(A) or NC as a indoor noise criteria that ASHRAE represents, and there is no specific guide line for application. According to the previous study, there are some problems like that even though the sound level of sound source is same, the NC shows different values, which makes the noise rating confused. This problem is caused by the frequency characteristics of sound source and its sound level. Therefore, appropriate evaluation method should be considered based on the subjective responses. This study aims to analyze the physical parameters appropriate for the evaluation of HVAC diffuser noise. To achieve this, recording of sound sources, calculation of physical parameters and psycho-acoustic experiment were carried out and the results were derived from the correlation analysis between physical parameters and subjective evaluatio

  • PDF

Design Considerations of Auditory Feedback for Enhancing The Usability of Portable Digital Electronic Products (휴대용 디지털 전자제품의 사용성 향상을 위한 청각적 피드백의 고려)

  • Kim, Hyeong-Seok;Park, Min-Yong
    • Journal of the Ergonomics Society of Korea
    • /
    • v.19 no.3
    • /
    • pp.51-60
    • /
    • 2000
  • Non-verbal sound feedback, called earcon, has been used for portable digital electronic products to give appropriate information for the selected function. This study evaluated usability based on user cognition time, error rate, and subjective satisfaction using 20 male and female subjects. The study compared five major user functions from a portable digital electronic product with currently available earcons and the same functions from the product with the new earcons (suggested by this study) which considered user cognitive characteristics, such as loudness, pitch, melody, and length. For subjective evaluation, the study assessed various earcons by subjective impression of sounds using the seven-point rating scales. Major statistical results indicated that the new earcons significantly reduced user error rates and generally improved user performance functions, such as 'play, off, stop, fast forward, and rewind.'

  • PDF

A Study for High Speed Judder Evaluation on Brake System (제동 시스템에서 고속 저더 개선 평가에 관한 연구)

  • Kim, Seonghwan;Cho, Sungsun;Lee, Junghwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.6
    • /
    • pp.485-494
    • /
    • 2013
  • This paper deals with experimental evaluation methods for high speed judder on the brake-caliper system. Firstly, two types of brake caliper systems due to the wheel vibration was evaluated. Secondly, the high-speed judder of the brake was also investigated using the subjective rating evaluation in the high-speed road test. These experimental evaluations were carried out by changing the materials of brake pad and the specifications of the brake-corner module. Based upon the test results, a new specification of the brake pad, $15{\times}5$ vertical chamfer, was proposed. The new brake pad showed 3 points, 60 %, improvement in the subjective-rating evaluation comparing with conventional one. Besides, we need to decide properly with judder characteristic of pad material and have to carefully take into consideration other design parameters; caliper, disc, and the braking performance, durability, squeal noise.

Performance, Wrist Motion and Subjective Rating for Handle Angle of Pliers (손잡이가 휜 Plier의 작업 수행도, 손목 동작과 만족도 평가)

  • Kee, Do-Hyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.49-57
    • /
    • 2008
  • This study aims to investigate the effect of handle angles of pliers on performance, wrist motion and subjective rating of satisfaction. An experiment was conducted, in which handle angle of pliers was used as independent variable and 14 subjects participated. Based on the literature survey, plier handles angled at 0$^{\circ}$, 10$^{\circ}$, 20$^{\circ}$, 30$^{\circ}$ and 40$^{\circ}$ were adopted in the experiment. The subjects were instructed to bend iron plates by 90$^{\circ}$ and to cut wires as soon as possible. The results revealed that 1) handle angles of pliers have significant effect on wrist motion and satisfaction(p<0.0001); 2) handle angles of pliers did not affect performance of completing tasks irrespective of types of tasks done in the study; 3) in the initial stage of windup, plier with handle angled at 20$^{\circ}$ produced the least wrist motion of deviation in task of bending iron plates, while plier with handle angled at 40$^{\circ}$ did in task of cutting wires; 4) degree of satisfaction was maximized when handle of pliers was bent by 20$^{\circ}$ in both tasks. On the basis of the results, it is recommended that handle of pliers be bent by 20-30$^{\circ}$ for reducing musculoskeletal disorders related to pliers.

An Experimental Study on the Subjective Response for Water Supply and Drain Installations in Apartment Bathroom (공동주택 급배수 설비소음의 주관반응에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Kim, Hang;Song, Guk-Gon;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.6
    • /
    • pp.663-673
    • /
    • 2008
  • The purpose of this study is to analyze the appropriate evaluation method for the water supply and drain noise of bathroom in apartment and to propose some fundamental idea on its regulation. For this reason, it was studied the acoustical characteristics of water supply and drain noise as modifying the water supply pressure for the washbasins and toilet stools and suggested the optimum evaluation method through psychoacoustic test. As a result of investigation of the levels by evaluating the adjectives and noise sources with 7-step criteria corresponding to each level of plumbing noises and analysis of the correlation between physical evaluation values by comparing the criteria, dB(A), N, and NC, with subject's response, determination coefficient($R^2$) was shown to be relatively fair or higher ranged from 0.65 to 0.92. It is shown that 'Harsh', 'Nervous', 'Unpleasant', 'Distasteful', and 'Repellent' as a second factor are to be appropriate to evaluate plumbing noise. Above these results could be used in basic data establishing KS(Korean Standard) for evaluation and rating procedure and measures reducing these noise.