• Title/Summary/Keyword: Study Module

Search Result 4,841, Processing Time 0.033 seconds

The use of MODIS atmospheric products to estimate cooling degree days at weather stations in South and North Korea (MODIS 대기자료를 활용한 남북한 기상관측소에서의 냉방도일 추정)

  • Yoo, Byoung Hyun;Kim, Kwang Soo;Lee, Jihye
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.21 no.2
    • /
    • pp.97-109
    • /
    • 2019
  • Degree days have been determined using temperature data measured at nearby weather stations to a site of interest to produce information for supporting decision-making on agricultural production. Alternatively, the data products of Moderate Resolution Imaging Spectroradiometer (MODIS) can be used for estimation of degree days in a given region, e.g., Korean Peninsula. The objective of this study was to develop a simple tool for processing the MODIS product for estimating cooling degree days (CDD), which would help assessment of heat stress conditions for a crop as well as energy requirement for greenhouses. A set of scripts written in R was implemented to obtain temperature profile data for the region of interest. These scripts had functionalities for processing spatial data, which include reprojection, mosaicking, and cropping. A module to extract air temperature at the surface pressure level was also developed using R extension packages such as rgdal and RcppArmadillo. Random forest (RF) models, which estimate mean temperature and CDD with a different set of MODIS data, were trained at 34 sites in South Korea during 2009 - 2018. Then, the values of CDD were calculated over Korean peninsula during the same period using those RF models. It was found that the CDD estimates using the MODIS data explained >74% of the variation in the CDD measurements at the weather stations in North Korea as well as South Korea. These results indicate that temperature data derived from the MODIS atmospheric products would be useful for reliable estimation of CDD. Our results also suggest that the MODIS data can be used for preparation of weather input data for other temperature-based agro-ecological models such as growing degree days or chill units.

Traditional Korean Medicine for Non-Small Cell Lung Cancer Patient Undergoing Pembrolizumab Immunotherapy: A Case Report (Pembrolizumab 면역치료를 시행 중인 비소세포성 폐암환자의 한방치료 증례보고)

  • Shim, So-hyun;Seo, Hee-jeong;Seo, Hyung-bum;Cho, Im-hak;Lee, Chan;Kim, So-yeon;Han, Chang-woo;Park, Seong-ha;Yun, Young-ju;Lee, In;Kwon, Jung-nam;Hong, Jin-woo;Choi, Jun-yong
    • The Journal of Internal Korean Medicine
    • /
    • v.40 no.4
    • /
    • pp.709-722
    • /
    • 2019
  • Objective: The purpose of this study was to report the effect of traditional Korean medicine (TKM) in alleviating the side effects of lung cancer patient undergoing immunotherapy. Method: A 43-year-old man, who was diagnosed with non-small cell lung cancer, received pembrolizumab treatments. The patient was treated with acupuncture and herbal medicine (Geoeoyangpye-tang) to control various uncomfortable symptoms. The degree of pain was measured by the numeric rating scale (NRS). The European Organization for Research and Treatment of Cancer Quality of Life Questionnaire, Core 30 (EORTC QLQ-C30) and the EORTC 13-item lung cancer-specific module (EORTC LC-13 questionnaire) were used to assess the change in the quality of life. Results: After the TKM treatment, the flank pain and arthralgia based on the NRS were significantly improved. Various uncomfortable symptoms such as fatigue, dyspnea, insomnia, and loss of appetite were also significantly improved, based on the EORTC QLQ-C30 and EORTC QLQ-LC13. The size of the primary tumor was decreased during treatment. The disease status was stable radiologically after two months from discharge.

Development of Chemical and Biological Decontamination Technology for Radioactive Liquid Wastes and Feasibility Study for Application to Liquid Waste Management System in APR1400 (액체방사성폐기물에 대한 화학적, 생물학적 제염기술 개발 및 APR1400 액체폐기물관리계통 적용을 위한 타당성 연구)

  • Son, YoungJu;Lee, Seung Yeop;Jung, JaeYeon;Kim, Chang-Lak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.17 no.1
    • /
    • pp.59-73
    • /
    • 2019
  • A decontamination technology for radioactive liquid wastes was newly developed and hypothetically applied to the liquid waste management system (LWMS) of the nuclear power plant (NPP) to evaluate its decontamination efficacy for the purpose of the fundamental reduction of spent resins. The basic principle of the developed technology is to convert major radionuclide ions in the liquid wastes into inorganic crystal minerals via chemical or biological techniques. In a laboratory batch experiment, the biological method selectively removed more than 80% of cesium within 24 hours, and the chemical method removed more than 95% of cesium. Other major nuclides (Co, Ni, Fe, Cr, Mn, Eu), which are commonly present in nuclear radioactive liquid wastes, were effectively scavenged by more than 99%. We have designed a module including the new technology that could be hypothetically installed between the reverse osmosis (R/O) package and the organic ion-exchange resin in the LWMS of the APR1400 reactor. From a technical evaluation for the virtual installation, we found that more than 90% of major radionuclides in the radioactive liquid wastes were selectively removed, resulting in a large volume reduction of spent resins. This means that if the new technology is commercialized in the future, it could possibly provide drastic cost reduction and significant extension of the life of resins in the management of spent resins, consequently leading to delay the saturation time of the Wolsong repository.

Analysis of support loads in large underground space for high-density arrangement of complex plant (복합플랜트 고집적 배치를 위한 지하대공간 지지하중 해석)

  • Kim, Sewon;Park, Jun Kyung;Lee, Sangjun;Kim, YoungSeok
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.2
    • /
    • pp.77-92
    • /
    • 2021
  • For the construction of a large underground space with a complex plant installed, it is necessary to analyze the stability considering the ground conditions and various load conditions. In this paper, finite element analysis was performed to analyze the support load that can be used in the design of a large underground space for high-density arrangement of complex plant. An analysis of underground continuous wall (D-wall) was performed considering the load and horizontal earth pressure in the large underground space. In addition, foundation ground analysis was carried out according to the load condition of the complex plant. In order to shorten the construction period, increase the space layout utilization, and secure the stability of the plant structure when installing the complex plant underground, the pipe rack module structure analysis was conducted. This study proposes a design and construction method for the optimal arrangement of underground complex plants using the analysis results.

Development of High-Durability Ceramic Hollow Fiber and Performance Evaluation of Contact Membrane Process according to Pressure Conditions (고내구성 세라믹 중공사 개발과 압력 조건에 따른 접촉막 공정의 특성 평가)

  • Lee, Seung Hwan;Jeong, Byeong Jun;Shin, Min Chang;Zhuang, Xuelong;Jung, Jiwon;Lee, Yeon Jun;Won, Dongyeon;Park, Jung Hoon
    • Membrane Journal
    • /
    • v.30 no.6
    • /
    • pp.443-449
    • /
    • 2020
  • In this study, CO2 separation experiment was performed on a CH4/CO2 mixed gas using a ceramic hollow fiber membrane contactor module (HFMC). In order to fabricate high-durability HFMC, a high-durability hollow fiber membrane was prepared and evaluated. HFMC was fabricated using the prepared hollow fiber membrane, and the experiment used a mixture of CH4/CO2 (30% CO2, CH4 balance) and monoethanolamine (MEA). During HFMC operation, the effect of gas and absorbent pressure on the CO2 removal efficiency was evaluated. The CO2 removal efficiency increased as the gas pressure increased, and the CO2 absorption flux also showed a tendency to increase with the liquid flow rate. In addition, when the CO2 absorption rate was less than 40%, LTS-1, a counter-current form where the absorbent enters from the bottom, has higher CO2 removal performance than LTS-2, a countercurrent form in which the absorbent enters from the top. and when the absorption rate was 40% or higher, LTS-2 had higher performance than LTS-1.

The bidirectional DC module type PCS design for the System Inter Connection PV-ESS of Secure to Expandability (계통 연계 PV-ESS 확장성 확보를 위한 병렬 DC-모듈형 PCS 설계)

  • Hwang, Lark-Hoon;Na, Seung-Kwon;Choi, Byung-Sang
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.1
    • /
    • pp.56-69
    • /
    • 2021
  • In this paper, the PV system with a link to the commercial system needs some advantages like small capacity, high power factor, high reliability, low harmonic output, maximum power operation of solar cell, and low cost, etc. as well as the properties of inverter. To transfer the PV energy of photovoltaic power generation system to the system and load, it requires PCS in both directions. The purpose of this paper is to confirm the stable power supply through the load leveling by presenting the PCS considering ESS of photovoltaic power generation. In order to achieve these purpose, 5 step process of operation mode algorithm were used according to the solar insolation amount and load capacity and the controller for charging/ discharging control was designed. For bidirectional and effective energy transfer, the bidirectional converter and battery at DC-link stage were connected and the DC-link voltage and inverter output voltage through the interactive inverter were controlled. In order to prove the validity of the suggested system, the simulation using PSIM was performed and were reviewed for its validity and stability. The 3[kW] PCS was manufactured and its test was conducted in order to check this situation. In addition, the system characteristics suggested through the test results was verified and the PCS system presented in this study was excellent and stronger than that of before system.

Numerical analysis of heat dissipation performance of heat sink for IGBT module depending on serpentine channel shape (수치 해석을 통한 절연 게이트 양극성 트랜지스터 모듈의 히트 싱크 유로 형상에 따른 방열 성능 분석)

  • Son, Jonghyun;Park, Sungkeun;Kim, Young-Beom
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.415-421
    • /
    • 2021
  • This study analyzed the effect on the cooling performance of the channel shape of a heat sink for an insulated gate bipolar transistor (IGBT). A serpentine channel was used for this analysis, and the parameter for the analysis was the number of curves. The analysis was conducted using computational fluid dynamics with the commercial software ANSYS fluent. One curve in the channel improved the heat dissipation performance of the heat sink by up to 8% compared to a straight-channel heat sink. However, two curves in the channel could not improve the heat discharge performance further. Instead, the two curves caused a higher pressure drop, which induces parasitic loss for the pumping of coolant. The pressure drop of the two-curve channel case was 2.48-2.55 times larger than that of a one-curve channel. This higher pressure drop decreased the heat discharge efficiency of the heat sink with two curves. The discharge heat per unit pressure drop was calculated, and the result of the straight heat sink was highest among the analyzed cases. This means that the heat discharge efficiency of the straight heat sink is the highest.

A Case Report of Korean Medicine Treatment of Non-small Cell Lung Cancer with Pleural Metastasis Following Targeted Chemotherapy with Afatinib (Afatinib 표적항암치료를 시행 중인 흉막 전이된 비소세포폐암 환자의 한방치료 증례보고)

  • Kim, Kyun Ha;Kang, Hee-kyung;Kim, So-yeon;Han, Chang-woo;Park, Seong-ha;Yun, Young-ju;Lee, In;Kwon, Jung-nam;Hong, Jin-woo;Choi, Jun-Yong
    • The Journal of Internal Korean Medicine
    • /
    • v.41 no.6
    • /
    • pp.1255-1264
    • /
    • 2020
  • Objective: The purpose of this study was to report the effect of Korean medicine on a patient with non-small cell lung cancer with pleural metastasis who had been treated with afatinib. Method: A 61-year old female patient with non-small cell lung cancer with pleural metastasis was treated with acupuncture and herbal medicines, including Yijung-tang, Haengso-tang, Samchulkunbi-tang, Paeamju-bang (Feiai zhu fang), to control various symptoms caused by afatinib. The degree of pain was assessed by a numeric rating scale (NRS) and the quality of life was determined with the European Organization for Research and Treatment of Cancer Quality of Life Questionnaire, Core 30 (EORTC QLQ-C30) and the EORTC 13-item lung cancer-specific module (EORTC LC-13). Results: After receiving acupuncture and herbal medicines, the patient showed improvement in her back and chest pain, according to the NRS score. Similarly, the Korean medicinal treatments significantly relieved her nausea, vomiting, diarrhea, hemoptysis, and alopecia. However, the EORTC QLQ-C30 assessment suggested that Korean medicinal treatments did not significantly improve the global health status of this patient. Conclusion: Korean medicine could be useful in relieving some of the symptoms occurring after conventional afatinib treatments.

Design and Implementation K-Band EWRG Transceiver for High-Resolution Rainfall Observation (고해상도 강수 관측을 위한 K-대역 전파강수계 송수신기 설계 및 구현)

  • Choi, Jeong-Ho;Lim, Sang-Hun;Park, Hyeong-Sam;Lee, Bae-Kyu
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.24 no.5
    • /
    • pp.646-654
    • /
    • 2020
  • This paper is to develop an electromagnetic wave-based sensor that can measure the spatial distribution of precipitation, and to a electromagnetic wave rain gauge (hereinafter, "EWRG") capable of simultaneously measuring rainfall, snowfall, and wind field, which are the core of heavy rain observation. Through this study, the LFM transmission and reception signals were theoretically analyzed. In addition, In order to develop a radar transceiver, LFM transceiver design and simulation were conducted. In this paper, we developed a K-BAND pulse-driven 6W SSPA(Solid State Power Amplifiers) transceiver using a small HMIC(Hybrid Microwave Integrated Circuit). It has more than 6W of output power and less than 5dB of receiving NF(Noise Figure) with short duty of 1% in high temperature environment of 65 degrees. The manufactured module emits LFM and Square Pulse waveform with the built-in waveform generator, and the receiver has more than 40dB of gain. The transceiver developed in this paper can be applied to the other small weather radar.

Cu Blackening through CuO Oxidation for the Application of Camera Lens Spacers in Mobile Phones (휴대폰 카메라 렌즈 스페이서 적용을 위한 구리의 흑화)

  • Lee, Yeji;Kim, Yong Ha;Kim, Chang Hyun;Won, Yong Sun
    • Clean Technology
    • /
    • v.27 no.1
    • /
    • pp.17-23
    • /
    • 2021
  • Black polymer spacers are currently used for physically separating aligned camera lenses in camera modules of mobile phones. However, the mechanical properties of polymer spacers have their limits, especially in the current trend of using more lenses in thinner camera modules. Thus, copper (Cu) becomes a good candidate for those polymer spacers because of its superior mechanical properties and its inherent blackness due to its black surfaced oxides, such as copper (II) oxide (cupric oxide, CuO). The latter property is critical in quality control because the closer the color of a spacer is to black, the less light interference and flaring phenomena can occur. A standard Cu blackening process and its operational conditions were proposed in this study through a comprehensive analysis of previous research and patents. The Cu blackening process is composed of cleaning, deoxidizing, activating, blackening and sealing. The effects of operational parameters, such as the temperature of each unit process and the activator concentration, were then investigated by measuring the blackness of the Cu strips with a colorimeter. The proposed operational conditions were determined by whether the blackness of Cu strips was within the on-spec. value used in the field.