• 제목/요약/키워드: Stuck Open

검색결과 29건 처리시간 0.025초

CMOS 회로의 전류 테스팅를 위한 내장형 전류감지기 설계 (Design of a Built-in Current Sensor for Current Testing Method in CMOS VLSI)

  • 김강철;한석붕
    • 전자공학회논문지B
    • /
    • 제32B권11호
    • /
    • pp.1434-1444
    • /
    • 1995
  • Current test has recently been known to be a promising testing method in CMOS VLSI because conventional voltage test can not make sure of the complete detection of bridging, gate-oxide shorts, stuck-open faults and etc. This paper presents a new BIC(built-in current sensor) for the internal current test in CMOS logic circuit. A single phase clock is used in the BIC to reduce the control circuitry of it and to perform a self- testing for a faulty current. The BIC is designed to detect the faulty current at the end of the clock period, so that it can test the CUT(circuit under test) with much longer critical propagation delay time and larger area than conventional BICs. The circuit is composed of 18 devices and verified by using the SPICE simulator.

  • PDF

AHP를 활용한 안전밸브(PSV) 고장모드의 Cause Factors 우선순위 분석 (Priority Analysis of Cause Factors of Safety Valve Failure Mode Using Analytical Hierarchy Process)

  • 김명철;이미정;이동건;백종배
    • Korean Chemical Engineering Research
    • /
    • 제60권3호
    • /
    • pp.347-355
    • /
    • 2022
  • 안전밸브(PSV)는 다양한 원인으로 발생하는 압력이 설정 압력에 도달하면 자동적으로 스프링이 작동하면서 분출되고 일정 압력 이하가 되면 정상상태로 복원되는 안전장치이다. 안전밸브는 압력상승 등 비정상 상태에서 정상 작동할 수 있도록 주기적인 검사와 모니터링 이행이 필수적이다. 그러나 현행 안전검사는 정해진 주기에만 수행되고 있어 정상작동 여부의 안전성을 확보하는 데 어려움이 있다. 따라서 안전관리에 필요한 안전밸브의 고장모드와 원인요소를 찾아 평가항목을 개발하였다. 그리고 항목의 우선순위를 도출하여 안전성 확보를 위한 의사결정 정보를 제공하고자 한다. 이를 위해 15명의 전문가를 대상으로 안전밸브(PSV)의 Failure Mode Cause Factor(FMCFs)와 관련하여 중요하다고 판단되는 평가요인을 도출하기 위해 3차례에 걸친 델파이(Delphi) 조사를 수행하였다. 그 결과 안전밸브의 6개 고장모드와 그 하위요인 22개의 평가요인을 선정하였다. 이와 같이 선정된 평가요인들의 우선순위를 분석하기 위해 계층구조를 도식화하였고 우선순위 계산에는 계층적 의사결정 방법(AHP)을 적용하였다. 분석결과 FMCFs의 고장모드 우선순위는 'Leakage'(0.226), 'Fail to open'(0.201), 'Fail to relieve req'd capacity'(0.152), 'Open above set pressure'(0.149), 'Spuriously open'(0.146), 'Stuck open'(0.127) 순으로 확인하였다. FMCFs의 하위 우선순위는 'PSV component rupture'(0.109), 'Fail to PSV size calculation'(0.068), 'PSV Spring aging'(0.065), 'Erratic opening'(0.059), 'Damage caused by improper installation and handling'(0.058), 'Fail to spring'(0.053) 등의순으로확인하였다. 우선순위가 결정된 FMCFs 효율적인 관리를 통해 안전밸브의 취약점을 파악하고 안전성을 향상하는데 기여할 수 있을 것으로 기대된다.

체외 고정구용 골 삽입 금속 나사 개발 (The Development of Pin Screws into the Bone for External Fixator)

  • 최영철;이근민;나운환;송병섭
    • 재활복지공학회논문지
    • /
    • 제2권1호
    • /
    • pp.5-17
    • /
    • 2009
  • 골에 삽입한 후 체외고정구에 결합하여 조절함으로써 골절회복(장골의 개방성골절, 연부조직의 재건술 및 관절고정술 등)에 사용되는 금속나사를 특별히 고안한 절삭도구와 연삭기구 및 독자적인 후처리 공정을 통하여 국내기술로 처음 개발, 상품화하였다. 개발된 제품과 수입제품의 비교실험을 실시한 결과, 수입제품대비 평균 103%의 특성을 나타내었다. 이 제품의 개발에 적용된 설계기법 및 후처리 공정과 요소실험 결과들을 소개한다.

  • PDF

도심지 대심도 복층터널의 환기 및 방재계획 (A Case Study on M & E Design for Double-Deck Tunnel in Urban Area)

  • 변상훈;정재호;전덕찬;신일재;심동현
    • 터널과지하공간
    • /
    • 제21권4호
    • /
    • pp.281-286
    • /
    • 2011
  • 최근, 서울시는 기존 서부간선도로의 극심한 교통정체 문제 해결을 위하여 연장 10.91 km에 달하는 새로운 소형차 전용 지하도로를 계획하였으며, 국내최초로 복층터널 형식을 적용하였다. 새로 건설될 서부간선 지하도로가 밀집한 도심지의 대심도 지하공간에 계획되므로, 인명피해 최소화를 위한 환기 및 방재계획이 중요한 문제로 대두되었으며, 본 고에서는 도심지 대심도 초장대 터널내 설비 및 안전시설에 관한 주요계획을 소개하고자 한다.

마이크로 컴퓨터와 확률론적 리스크 평가를 통한 가압기 보호계통의 설계 개선 (Improvement of Pressurizer PROV System through Micro-Computer and PRA)

  • Jong Ho Lee;Soon Heung Chang
    • Nuclear Engineering and Technology
    • /
    • 제17권4호
    • /
    • pp.302-316
    • /
    • 1985
  • TMI와 월성 사고 이후 PORV를 통한 Small LOCA는 원자력 발전소 리스크의 중요한 요소로 부각되었다. 본 논문에서는 이 계통을 통한 Pressurizer Surveillance System의 설제와 그에 따른 영향을 확률론적 리스크 평가(PBA) 방법으로 해석하였다. 마이크로 컴퓨터는 계통의 고장(Malfunction)을 공정 확인 방법(Process Checking Method)으로 진단하고 그 진단에 따른 후속 동작(Backup Action)을 자동으로 수행한다. 이러한 개선에 따라 운전원의 빠르고 정확한 판단이 어려웠던 “Spurious Opening”, “Fail to Reclose” 및 “Small Break LOCA” 등의 진상(Symptom) 이 정확히 진단되고, 후속 동작의 자동화로 인하여 인간 실수 확률이 기계적 실수 확률로 감소하게 되었다. 결국. 이러한 개선은 계통의 신뢰도 증가로 Small LOCA 확률의 감소를 가져다 준다.

  • PDF

자동차의 사이드미러가 흉강에 박힌 채로 내원한 흉부관통상 - 2례 보고 - (Penetrating Chest Injuries Caused by the Sideview Mirror of the Patient's Car - Report of 2 cases -)

  • 김수성
    • Journal of Trauma and Injury
    • /
    • 제20권1호
    • /
    • pp.47-51
    • /
    • 2007
  • Penetrating chest trauma caused by the components of one's own car is rare in motor vehicle accidents. We experienced two cases of penetrating chest injury caused by the sideview mirror of the patient's vehicle. One was a 25-year-old man. The sideview mirror penetrated the left chest, went through the diaphragm, and ruptured the spleen. He was in shock upon arrival at the emergency room. An emergency thoracotomy and laparotomy were done. The ruptured spleen was resected, the lung and the diaphragm were debrided and repaired, and the chest wall was reconstructed. The other patient was a 57-year-old male, who was transported to our emergency room with the sideview mirror of his truck stuck into his right chest wall as the result of an accident. He also had a right Bennet's fracture and an open fracture of the right tibia. Air had been sucked into the right pleural cavity through the wound. Multiple rib fractures and lung lacerations had also occurred. Removal of the sideview mirror, repair of the lacerated lung, and reconstruction of chest wall were done immediately. Both patients recovered without complication and were discharged.

차량 시뮬레이터를 이용한 운전행동 연구(운전분노 및 교통정체를 중심으로) (A study of Drivers' Behaviors using a Driving Simulator(with Special Reference of Driving Anger and Traffic Congestion)

  • 송혜수;신용균;강수철
    • 대한교통학회지
    • /
    • 제23권2호
    • /
    • pp.61-74
    • /
    • 2005
  • 본 연구는 운전분노와 교통정체가 운전행동에 미치는 영향을 조사한 것이다. 운전분노란 운전 중 경험하는 분노로서 개인적 특질성향이다. 이 개인전 성향은 운전 중 도발적이고 도전적인 상황에 부딪혔을 때 난폭운전으로 표출된다. 그런데 운전분노는 다른 성격특질처럼 개인차가 있어서 운전분노 수준에 따라 교통상황에서 느끼는 분노의 정도는 차이가 나고, 이 차이는 난폭운전의 차이로 나타날 가능성이 높다. 본 연구에서는 차량 시뮬레이터인 RTSA-DS를 이용하여 세 가지 교통상황(소통원활, 주행차로정체 및 선행차량의 서행으로 인한 진행방해 상황)을 가상현실 교통상황으로 제시하고, 운전분노 수준에 따른 운전행동을 조사 비교하였다. 그 결과 운전분노 수준이 높은 운전자가 낮은 운전자에 비해 주행차로 정체상황에서 빠른 속도로 주행하였으며, 주행차로 정체상황에서 정체를 피하기 위해 차로변경을 시도하였고, 이 과정에서 충돌사고의 개입율이 높은 것으로 나타났다. 이 결과는 운전분노 수준이 높은 운전자가 정체상황에서 난폭운전과 위험운전을 감행한다는 이전의 연구결과와 일치한다. 그러나 운전 분노 수준이 높은 집단이 주로 20대 운전자로 구성되었고, 운전분노와 연령간의 상관이 높은 점을 감안할 때 본 연구의 결과 적용 시 주의가 필요하다.

3D 프린팅과 구조해석을 이용한 맨홀의 부양장치 설계 및 제작 (Design and Prototyping of Lifting Devices for Manhole Cover using Structural Analysis and 3D Printing)

  • 이형욱
    • 한국산학기술학회논문지
    • /
    • 제19권10호
    • /
    • pp.648-654
    • /
    • 2018
  • 본 노면에 설치되어있는 맨홀의 지속적인 관리를 위해서는 맨홀의 개폐가 쉬워야 한다. 가혹한 조건하에 있는 맨홀은 틀과 커버가 고착되어 개폐가 어렵기 때문에 맨홀을 열 때 부양이 가능한 맨홀이 요구된다. 본 연구에서는 잠금식 맨홀을 부양식 맨홀로 개선하기 위한 부양 기구의 설계를 진행하였다. 잠금식 맨홀의 기구는 중앙에 위치한 볼트를 돌리면 볼트와 연결된 허브가 하강하고, 허브와 연결되어 있는 후크를 회전시키게 된다. 후크의 끝단이 맨홀 틀에 걸리도록 되어있다. 본 연구에서는 맨홀의 부양이 가능하도록 후크에 보조장치를 설치하도록 하였다. 부양 기능을 수행할 후크의 항복응력의 70%를 기준으로 약 300kg의 부양력을 지지할 수 있도록 구조를 설계하였다. 유한요소법을 이용한 구조해석을 통하여 형상 설계를 수행하였다. 우선 단순화된 2차원 모델로 1차 기초설계를 수행하고, 3차원 모델을 통하여 부착위치와 형상을 설계하였다. 설계된 형상에 대하여 구조적 문제점을 찾아보기 위하여 3D 프린팅을 통하여 축소 모델을 출력하였고, 기능이 작동함을 확인하였다. 최종적으로 가공을 통하여 부양 기구를 제작하여 기존의 잠금식 맨홀에 적용한 결과 평균 6.1 mm 정도의 부양이 가능함을 확인하였다.

형태학적 연산과 선분 근사화를 이용한 침 검출 (Needle Detection by using Morphological Operation and Line Segment Approximation)

  • 장경식;한수환
    • 한국정보통신학회논문지
    • /
    • 제19권12호
    • /
    • pp.2785-2791
    • /
    • 2015
  • 이 논문에서는 한방 치료에서 피부에 직침된 침의 제거를 위한 침 검출 방법을 제안한다. 명암도 영상에서 형태학적 열기 연산을 이용하여 침 후보 영역이 검출되고 크기 정보 등을 이용하여 거짓 침 후보 영역이 제거된다. 각 후보영역에서 canny 에지 검출기를 사용하여 에지 점들을 찾고 이들 점들을 선분으로 근사화한다. 선분들의 방향과 선분간의 거리를 기반으로 하는 형태학적 분석을 통해 두 개의 주요 선분을 찾고 침 머리 부분을 검출한다. 119개의 침이 직침된 16개의 영상에 대한 실험 결과 97.5 %의 검출율을 얻었다.