• Title/Summary/Keyword: Structure Enhancement

Search Result 971, Processing Time 0.028 seconds

The Electrical Properties of Single-silicon TFT Structure with Symmetric Dual-Gate for kink effect suppression

  • Lee, Deok-Jin;Kang, Ey-Goo
    • Journal of the Korea Computer Industry Society
    • /
    • v.6 no.5
    • /
    • pp.783-790
    • /
    • 2005
  • In this paper, we have simulated a Symmetric Dual-gate Single-Si TFT which has three split floating n+ zones. This structure reduces the kink-effect drastically and improves the on-current. Due to the separated floating n+ zones, the transistor channel region is split into four zones with different lengths defined by a floating n+ region, This structure allows an effective reduction of the kink-effect depending on the length of two sub-channels. The on-current of the proposed dual-gate structure is 0.9mA while that of the conventional dual-gate structure is 0.5mA at a 12V drain voltage and a 7V gate voltage. This result shows a 80% enhancement in on-current. Moreover we observed the reduction of electric field in the channel region compared to conventional single-gate TFT and the reduction of the output conductance in the saturation region. In addition, we also confirmed the reduction of hole concentration in the channel region so that the kink-effect reduces effectively.

  • PDF

Shaking Table Test of Small Scale RC Structure with Tuned Liquid Damper (동조액체 감쇠기를 설치한 철근콘크리트 축소모델의 진동대 실험)

  • Woo, Seang-Sik;Lee, Sang-Hyun;Chung, Lan
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.113-116
    • /
    • 2005
  • In this study, in order to. investigate the effectiveness af tuned liquid damper (TLD) for the seismic performance enhancement af the existing reinforced concrete (RC) apartment structure which is nat seismically designed, shaking table test was conducted for the small scale five stary RC structure with TLD. TLD model was constructed to. have the frequency tuned to. the first modal frequency af the structure, $2\%$ mass ratio. af the first modal mass, and 0.08 liquid depth ratio. White noise with $0.2\~5Hz$ frequency bandwidth tests were performed using the shaking table at Korea Institute af Machinery and Materials, and the displacement and absolute acceleration af each floor were measured. Test results indicate that mare than $30\%$ seismic responses reduction can be achieved using TLD for RC structure under white noise.

  • PDF

New Front Plate Structure of ac-PDP using Aluminum Fence-Type Electrode Coated with Anodic Aluminum Oxide

  • Lee, Mi-yeon;Yoon, Sang-Hoon;Kim, Yong-Seog
    • Journal of Information Display
    • /
    • v.8 no.4
    • /
    • pp.19-22
    • /
    • 2007
  • A new front plate structure of ac-PDP using fence-type aluminum electrode coated with anodic aluminum oxide was investigated. In this structure, ITO and glass dielectric layer were eliminated and expensive Ag BUS electrode was replaced with aluminum. Test panels were prepared using the new structure and their luminance and discharge characteristics were examined. These results indicate that the new structure provide a new way of cost reduction and enhancement of performance of ac-PDPs

New Front Plate Structure of ac-PDP using Aluminum Fence-type Electrode Coated with Anodic Aluminum Oxide

  • Lee, Mi-Yeon;Yoon, Sang-Hoon;Kim, Yong-Seog
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.127-130
    • /
    • 2007
  • A new front plate structure of ac-PDP was explored using fence-type aluminum electrode coated with anodic aluminum oxide.[1] In this structure, ITO and glass dielectric layer were eliminated and expensive Ag BUS electrode was replaced with aluminum. Test panels were prepared using the new structure and their luminance and discharge characteristics were examined. These results indicate that the new structure provide a new way of cost reduction and enhancement of performance of ac-PDPs

  • PDF

Comparison of Hole Mobility Characteristics of Single Channel and Dual Channel Si/SiGe Structure (단일채널 Strained Si/SiGe 구조와 이중채널 Strained Si/SiGe 구조의 이동도 특성 비교)

  • Jung, Jong-Wan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.113-114
    • /
    • 2007
  • Hole mobility characteristics of single surface channel and dual channel Si/SiGe structure are compared, where the former one consists of a relaxed SiGe buffer layer and a tensile strained Si layer on top, and for dual channel structure a compressively strained SiGe layer is inserted between them. Due to the difference of hole mobility enhancement factors of layers between them, hole mobility characteristics with respect to the Si cap thickness shows the opposite tend. Hole mobility increases with thicker Si cap for single channel structure, whereas it decreases with thicker Si cap for dual channel structure.

  • PDF

Effect of temperature gradient on junction magnetoresistance of magnetic tunnel junction devices

  • No, Seong-Cheol;Park, Min-Gyu;Lee, Yeo-Reum
    • Proceeding of EDISON Challenge
    • /
    • 2014.03a
    • /
    • pp.495-497
    • /
    • 2014
  • Combining the quantum transport theory with new field of Spin Caloritronics, we investigate on the influence of thermal gradient on the magneto tunnel junction structure under various circumstances. The results indicate enhancement in performance of spintronic device is possible using thermal energy.

  • PDF

Enhancement of Fe Magnetic Moments in Ferromagnetic $Fe_{16}N_2$ (강자성 $Fe_{16}N_2$ 화합물에서의 Fe 자기모멘트의 증가)

  • 민병일;김창석
    • Journal of the Korean Magnetics Society
    • /
    • v.1 no.2
    • /
    • pp.9-14
    • /
    • 1991
  • In order to investigate electronic and magnetic properties of $Fe_{16}N_{2}$ ferromagnet, we have performed electronic structure calculations employing the self-consistent local density functional LMTO(linearized muffin tin orbital) band method. We have obtained the ground state parameters, such as band structures, density of states, Stoner parameters, and magnetic moments. Based on these results, we have investigated microscopically the magnetic structure and the enhancement of Fe magnetic moments in this compound. Magnetic moments of 3 types of Fe(Fe I, Fe II and Fe III) in $Fe_{16}N_{2}$ are 2.13, 2.50, and $2.85\;{\mu}_{B}$, respectively. Large enhancement of Fe magnetic moment is observed in Fe II and Fe III, which are located rather far from N. This implies that local environment is very important in determining the Fe magnetic moments in this compound. Our value of average magnetic moment per Fe atom. $2.50\;{\mu}_{B}$, is a bit smaller than the reported estimate, $-3.0\;{\mu}_{B}$, from the experiment.

  • PDF

Experimental Investigation of CHF Enhancement on the Modified Surface Under Pool Boiling (개질된 표면을 이용한 풀비등 임계열유속 증진에 관련한 실험적 연구)

  • Kang, Soon-Ho;Ahn, Ho-Seon;Jo, Hang-Jin;Kim, Moo-Hwan;Kim, Hyung-Mo;Kim, Joon-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.33 no.11
    • /
    • pp.840-848
    • /
    • 2009
  • In the boiling heat transfer mechanism, CHF(critical heat flux) is the significantly important parameter of the system. So, many researchers have been struggling to enhance the CHF of the system in enormous methods. Recently, there were lots of researches about enormous CHF enhancement with the nanofluids. In that, the pool boiling CHF in nanofluids has the significantly increased value compared to that in pure water because of the deposition of the nanoparticle on the heater surface in the nanofluids. The aim of this study is the comparison of the effect of the nanoparticle deposited surface and the modified surface which has the similar morphology and made by MEMS fabrication. The nanoparticle deposited surface has the complex structures in nano-micro scale. Therefore, we fabricated the surfaces which has the similar wettability and coated with the micro size post and nano structure. The experiment is performed in 3 cases : the bare surface with 0.002% water-ZnO nanofluids, the nanoparticle deposited surface with pure water and the new fabricated surface with pure water. The contact angle, a representative parameter of the wettability, of the all 3 cases has the similar value about 0 and the SEM(scanning electron microscope) images of the surfaces show the complex nano-micro structure. From the pool boiling experiment of the each case, the nanoparticle deposited surface with pure water and the fabricated surface with pure water has the almost same CHF value. In other words, the CHF enhancement of the nanoparticle deposited surface is the surface effect. It also shows that the new fabricated surface follows the nanoparticle deposited surface well.