연구용 원자로 내부에 설치되는 이차정지구동장치의 내진낙하성능 (Seismic Drop Performance for Second Shutdown Drive Mechanism Installed in Research Reactor)

  • 김상헌;김경호;선종오;조영갑;김정현;정택형;이관희
    • 한국소음진동공학회논문집
    • /
    • 제26권6_spc호
    • /
    • pp.697-704
    • /
    • 2016
  • The second shutdown drive mechanism (SSDM) that is classified into seismic category I as an active mechanical equipment shall maintain the structural integrity and its designed inherent safety functions during and/or after normal operation, anticipated operational occurrences, accidents and seismic occurrences. Therefore, not only a structural integrity assessment through numerical analyses but also a qualification test by using the prototype SSDM shall be conducted to verify the adequacy of the SSDM design. This paper describes a sort of seismic qualification test of the prototype SSDM to demonstrate that the structural integrity and operability (functionality) of SSDM are maintained during and/or after seismic excitations. From the results, this paper shows that the SSDM satisfies all design requirements without any malfunctions during and after the seismic test.

발사환경에 대한 위성 전장품의 구조진동 해석 (Structural Vibration Analysis of Electronic Equipment for Satellite under Launch Environments)

  • 정일호;박태원;한상원;서종휘;김성훈
    • 한국정밀공학회지
    • /
    • 제21권8호
    • /
    • pp.120-128
    • /
    • 2004
  • The impulse between launch vehicle and atmosphere can generate a lot of noise and vibration during the process of launching a satellite. Structurally, the electronic equipment of a satellite consists of an aluminum case containing PCB. Each PCB has resistors and IC. Noise and vibration of the wide frequency band are transferred to the inside of fairing, subsequently creating vibration of the electronic equipment of the satellite. In this situation, random vibration can cause malfunctioning of the electronic equipment of the device. Furthermore, when the frequency of random vibration meets with natural frequency of PCB, fatigue fracture may occur in the part of solder joint. The launching environment, thus, needs to be carefully considered when designing the electronic equipment of a satellite. In general, the safety of the electronic equipment is supposed to be related to the natural frequency, shapes of mode and dynamic deflection of PCB in the electronic equipment. Structural vibration analysis of PCB and its electronic components can be performed using either FEM or vibration test. In this study, the natural frequency and dynamic deflection of PCB are measured by FEM, and the safety of the electronic components of PCB is evaluated according to the results. This study presents a unique method for finite element modeling and analysis of PCB and its electronic components. The results of FEA are verified by vibration test. The method proposed herein may be applicable to various designs ranging from the electronic equipments of a satellite to home electronics.

안전 구조물의 퍼포먼스 측정시 나타나는 Euler 방정식의 수치해석적 안정성 (Numerical Experiments on the Stability of Euler Equations of the Performance Test of Safety Structures)

  • 고만기;우광성
    • 전산구조공학
    • /
    • 제7권3호
    • /
    • pp.83-93
    • /
    • 1994
  • 도로 안전 구조물을 설계하고 동적 퍼포먼스를 측정하기 위하여 시행되는 충돌시험시 충돌차량의 운동량, 특히 각가속도를 Euler방정식의 수치적분을 통하여 구하는 기법을 설명하였다. 수치적으로 가장 안정적인 9-array 시스템안에 내지된 여러 형태의 7,8-array 서브시스템들의 시스템 미분방정식 및 이들 방정식의 수치 적분시 안정성을 실험데이터를 이용하여 파악하였다. 기본적인 9-array안에 있는 6개의 8-array시스템들은 모두 수치적으로 안정성을 보였고 12개의 7-array시스템들중 6개는 안정성을 보이고 6개는 불안정하였다. 안정성을 보이는 내재된 서브시스템을 활용하면 기본 9-array시스템을 구성하는 센서의 일부 고장시 효과적으로 각가속도를 측정할 수 있는 fail-safe 시스템을 구성할 수 있다.

  • PDF

Test on the anchoring components of steel shear keys in precast shear walls

  • Shen, Shao-Dong;Pan, Peng;Li, Wen-Feng;Miao, Qi-Song;Gong, Run-Hua
    • Smart Structures and Systems
    • /
    • 제24권6호
    • /
    • pp.783-791
    • /
    • 2019
  • Prefabricated reinforced-concrete shear walls are used extensively in building structures because they are convenient to construct and environmentally sustainable. To make large walls easier to transport, they are divided into smaller segments and then assembled at the construction site using a variety of connection methods. The present paper proposes a precast shear wall assembled using steel shear keys, wherein the shear keys are fixed on the embedded steel plates of adjacent wall segments by combined plug and fillet welding. The anchoring strength of shear keys is known to affect the mechanical properties of the wall segments. Loading tests were therefore performed to observe the behavior of precast shear wall specimens with different anchoring components for shear keys. The specimen with insufficient strength of anchoring components was found to have reduced stiffness and lateral resistance. Conversely, an extremely high anchoring strength led to a short-column effect at the base of the wall segments and low deformation ability. Finally, for practical engineering purposes, a design approach involving the safety coefficient of anchoring components for steel shear keys is suggested.

Active mass driver control system for suppressing wind-induced vibration of the Canton Tower

  • Xu, Huai-Bing;Zhang, Chun-Wei;Li, Hui;Tan, Ping;Ou, Jin-Ping;Zhou, Fu-Lin
    • Smart Structures and Systems
    • /
    • 제13권2호
    • /
    • pp.281-303
    • /
    • 2014
  • In order to suppress the wind-induced vibrations of the Canton Tower, a pair of active mass driver (AMD) systems has been installed on the top of the main structure. The structural principal directions in which the bending modes of the structure are uncoupled are proposed and verified based on the orthogonal projection approach. For the vibration control design in the principal X direction, the simplified model of the structure is developed based on the finite element model and modified according to the field measurements under wind excitations. The AMD system driven by permanent magnet synchronous linear motors are adopted. The dynamical models of the AMD subsystems are determined according to the open-loop test results by using nonlinear least square fitting method. The continuous variable gain feedback (VGF) control strategy is adopted to make the AMD system adaptive to the variation in the intensity of wind excitations. Finally, the field tests of free vibration control are carried out. The field test results of AMD control show that the damping ratio of the first vibration mode increases up to 11 times of the original value without control.

방사성물질 운반용기 완충체의 자유낙하 충격 거동에 관한 연구 (A Study on the free drop impact analysis of the impact limiter for radioactive material transportation cask)

  • 박홍윤;신동필;서기석;정성환;홍성인
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.98-102
    • /
    • 2002
  • As the nuclear power plant has been operated continuously and increased gradually, transportation and storage of spent fuel are seriously considered nowadays. The transportation cask which contains radioactive material needs to be inspected about structural safety. About safety verification, description of IAEA Safety Standards states that cask must withstand hypothetical accident conditions. In this paper, 9m free drop impact analysis was performed for transportation cask and impact limiter by using the finite element methods. Furthermore, we obtained the dynamic behavior of wood to as compared with safety test results, and verified the safety of transportation cask.

  • PDF

SEM-based study on the impact of safety culture on unsafe behaviors in Chinese nuclear power plants

  • Licao Dai;Li Ma;Meihui Zhang;Ziyi Liang
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3628-3638
    • /
    • 2023
  • This paper uses 135 Licensed Operator Event Reports (LOER) from Chinese nuclear plants to analyze how safety culture affects unsafe behaviors in nuclear power plants. On the basis of a modified human factors analysis and classification system (HFACS) framework, structural equation model (SEM) is used to explore the relationship between latent variables at various levels. Correlation tests such as chi-square test are used to analyze the path from safety culture to unsafe behaviors. The role of latent error is clarified. The results show that the ratio of latent errors to active errors is 3.4:1. The key path linking safety culture weaknesses to unsafe behaviors is Organizational Processes → Inadequate Supervision → Physical/Technical Environment → Skill-based Errors. The most influential factors on the latent variables at each level in the HFACS framework are Organizational Processes, Inadequate Supervision, Physical Environment, and Skill-based Errors.

Type4 복합재 용기의 돔 형상에 따른 파열형태에 관한 연구 (A Study on Failure Modes of Type4 Composite Pressure Cylinders according to Shapes of Domes)

  • 조성민;김광석;조민식;이선규;이승국;류성기
    • 한국기계가공학회지
    • /
    • 제16권5호
    • /
    • pp.13-18
    • /
    • 2017
  • In this work the augmented safety of Type 4 composite vessel in accordance with uniform-stress design has been demonstrated through a series of burst tests and structural analyses. For this end, three sample vessels were used: (1) designed as guided by the isotensoid dome theory (called iso-dome cylinder); (2) with dome longer compared to uniform-stress design (called prolate cylinder); and (3) with dome wider than uniform-stress design (called oblate cylinder). Structural analyses have been performed using ABAQUS finite element code based on the periodic symmetry to circumferential direction. As a result, the maximum stresses are induced around the bodies of all three cylinders. However, the analyses, with the assumption of possible defect demonstrate that the maximum stresses are induced around the dome knuckles for the prolate and the oblate cylinders. The results of the burst tests for the three cylinders show that the burst initiates from the cylinder body of the iso-dome cylinder and from the dome knuckles of the prolate and the oblate cylinders. Finally, it is recommended that, to comply with DOT CFFC 2007, the dome shape should be designed and fabricated as guided by the isotensoid dome theory.

구조시험 및 유한요소해석을 통한 소형풍력발전용 복합재 블레이드의 구조 안전성 평가 (Structural Integrity of Small Wind Turbine Composite Blade Using Structural Test and Finite Element Analysis)

  • 장윤정;이장호;강기원
    • 대한기계학회논문집A
    • /
    • 제36권9호
    • /
    • pp.1087-1094
    • /
    • 2012
  • 본 논문에서는 구조 시험과 유한요소해석을 통하여 소형 풍력발전용 복합재 블레이드의 구조적 안전성을 평가하였다. 먼저, 선행연구에서 공력해석을 수행하여 정격 및 극한 풍속일 때의 블레이드가 받는 굽힘 모멘트를 산출하였다. 이를 이용하여 소형풍력발전기 관련 국제 규격인 IEC 61400-2에 따른 실규모 구조 시험을 수행하여 구조적 안전성을 평가하였다. 그리고 유한요소법을 이용한 구조 해석을 수행하여 구조 시험 결과와 비교하여 이의 정확성을 판단하였다. 또한, 구조 시험을 통해 블레이드에 대한 과잉 설계가 확인되었으며 이의 해결을 위하여 블레이드의 적층 순서 및 두께를 재선정하여 구조적 안전성을 평가하였다.

방사성물질 운반용기의 적층시험조건에 대한 안전성 평가 (Safety Evaluation of Radioactive Material Transport Package under Stacking Test Condition)

  • 이주찬;서기석;유성연
    • 방사성폐기물학회지
    • /
    • 제10권1호
    • /
    • pp.37-43
    • /
    • 2012
  • IAEA 및 국내의 방사성물질 운반 관련 규정에 따라 중 저준위 방사성폐기물 드럼 8개를 운반할 수 있는 IP-2형 운반용기를 개발하였다. IP-2형 운반용기는 낙하시험 및 적층시험을 거친 후 내용물의 유실 또는 분산과 운반용기 외부표면에서의 방사선량률이 20 % 이상 증가할 수 있는 차폐능력의 상실이 없어야 한다. 본 연구의 목적은 적층시험조건에 대한 시험방법 및 절차를 수립하고 IP-2형 운반용기의 적층조건에 대한 구조적 건전성을 평가하는데 있다. 운반용기의 원형시험모델을 이용하여 운반용기 중량의 5배 하중으로 24시간 동안 압축하는 적층조건에 대한 시험 및 전산해석을 수행하였다. 적층시험 시 운반용기의 모서리기둥에서의 변형률 및 변위를 측정하였으며, 측정된 변형률 및 변위는 해석결과와 서로 일치하였다. 컨테이너 바닥부의 처짐량은 측정이 어렵기 때문에 전산해석 방법으로 구하였다. 모서리기둥의 최대 변위와 컨테이너 바닥의 최대 처짐은 법규에서 규정하는 허용치에 비하여 낮게 나타났다. 적층시험 전 후에는 운반용기의 외형치수, 차폐체 두께, 볼트토크 등을 측정하였으며, 그 값들을 비교분석한 결과 운반용기는 내용물의 유실 및 분산, 차폐체 두께의 감소가 나타나지 않았다. 따라서 적층시험조건에서 IP-2형 운반용기의 구조적 건전성이 입증되었다.