Pseudo-dynamic and cyclic loading tests on a steel-concrete vertical hybrid structure

  • Wang, Bo;Wu, Tao;Dai, Huijuan;Bai, Guoliang;Wu, Jian
    • Earthquakes and Structures
    • /
    • v.17 no.4
    • /
    • pp.399-409
    • /
    • 2019
  • This paper presents the experimental investigations on the seismic performance of a peculiar steel-concrete vertical hybrid structural system referred to as steel truss-RC tubular column hybrid structure. It is typically applied as the supporting structural system to house air-cooled condensers in thermal power plants (TPPs). Firstly, pseudo-dynamic tests (PDTs) are performed on a scaled substructure to investigate the seismic performance of this hybrid structure under different hazard levels. The deformation performance, deterioration behavior and energy dissipation characteristics are analyzed. Then, a cyclic loading test is conducted after the final loading case of PDTs to verify the ultimate seismic resistant capacity of this hybrid structure. Finally, the failure mechanism is discussed through mechanical analysis based on the test results. The research results indicate that the steel truss-RC tubular column hybrid structure is an anti-seismic structural system with single-fortification line. RC tubular columns are the main energy dissipated components. The truss-to-column connections are the structural weak parts. In general, it has good ductile performance to satisfy the seismic design requirements in high-intensity earthquake regions.

Real-scale field testing for the applicability examination of an improved modular underground arch culvert with vertical walls

  • Tae-Yun Kwon;Jin-Hee Ahn;Hong-duk Moon;Kwang-Il Cho;Jungwon Huh
    • Advances in concrete construction
    • /
    • v.15 no.6
    • /
    • pp.377-389
    • /
    • 2023
  • In this study, an improved modular arch system with the lower arch space composed of a precast arch block and an outrigger was proposed as an underground culvert, and its applicability and structural behaviors were confirmed. This modular arch culvert structure with vertical walls was designed using precast blocks and by adjusting the placement spacing of concrete blocks to the upper part form an arch shape and the lower part form a vertical wall shape, based on previously researched modular arch systems. Owing to the vertical wall of the proposed modular arch system, it is possible to secure a load-carrying capacity and an arch space that can sufficiently resist the earth pressure generated from the backfill soil and loading on the arch system. To verify the structural characteristics, and applicability of the proposed modular precast arch culvert structure, a full-scale modular culvert specimen was fabricated, and a loading test was conducted. By examining its construction process and loading test results, the applicability and constructability of the proposed structure were analyzed along with its structural characteristics. In addition, its the structural predictability and safety for the applicability were evaluated by comparing the construction process and loading test results with the FE analysis results.

A Structural Analysis of Causality between Safety Leadership and Related Factors in the Metro Driver Organization (도시철도 기관사조직의 안전리더십과 관련요인 간의 인과관계 구조분석)

  • Kang, Keun-Sik;Shin, Tack-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.4
    • /
    • pp.105-113
    • /
    • 2017
  • This study highlights the theme of safety leadership in railway organization, conducting empirical analysis on the relationship between safety climates, safety leadership, safety behavior, and accident. The empirical test results based on questionnaires received from 223 train drivers working at A subway firm indicated that relationship between CEO's safety philosophy, and safety communication showed a significant positive effect on boss's safety leadership. And boss's safety leadership showed a positive influence on observation belonging to safety behavior, which in turn showed a significant negative relationship with mistake. However, mistake, observation and violation were shown that there are no relationship with accidents.

A Study on the Structural Analysis and Design Verification of Variable Swash Plate Piston Pump Case for Wheeled Armored Vehicle (차륜형 장갑차용 가변형 사판식 피스톤 펌프 케이스의 구조해석 및 설계검증에 관한 연구)

  • Choi, Seong Woong;Kim, Yong Seok;Yang, Soon Yong
    • Journal of Drive and Control
    • /
    • v.16 no.2
    • /
    • pp.43-50
    • /
    • 2019
  • The objective of this study was to reverse engineer a swash plate type piston pump mounted on a wheeled armored vehicle and to analyze the structure of the pump case. From the analysis, the weak parts were identified and corrected in the final design. Each element corresponding to the piston pump case was analyzed. The analytical method was given static boundary conditions, load conditions and confirmed displacement, strain, stress, and safety factor. Plastic deformation and damage were also confirmed and the component elements redesigned through structural analysis Structural analysis and vibration analysis were carried out for the components of the piston pump case. The piston pump model was finally modified by structural analysis and vibration analysis results for each component assembly, and a prototype was designed. Durability test and environmental test were carried out and the test results satisfied all of the requirements. Therefore, the analytical method presented in this study can be utilized as a methodology for element component design in the development of various piston pumps.

Vibration Stability Analysis of Automotive Exhaust Sensor (자동차 배기계 센서 구성품의 진동 안정성 해석)

  • Park, Hyun Bum
    • Journal of Aerospace System Engineering
    • /
    • v.11 no.4
    • /
    • pp.44-47
    • /
    • 2017
  • This work dealt with vibration stability analysis of automotive exhaust sensor. In this work, structural design and analysis of exhaust gas sensor of automobile system were performed. Firstly, structural design requirement of automobile exhaust system was investigated. After structural design, the structural analysis of the exhaust measurement sensor system were performed usig the finite element analysis method. It was performed that the vibration and thermal stress analysis at the high temperature condition. After structural test of target structure, structural test results were compared with analysis results. Through the structural analysis, it was confirmed that the designed measurement sensor structure is safety.

A Study on Resonance and Interference of a Cooling Fan Assembly by Using FEM (유한요소법을 이용한 쿨링팬의 진동 및 간섭에 관한 연구)

  • 정일호;송하종;박태원;김주용
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.919-924
    • /
    • 2004
  • A CFA(Cooling Fan Assembly) is composed of a fan, motor and shroud, which is at the back of the automotive radiator. By forcing the wind to pass, the CFA controls the cooling performance of the radiator. The noise and vibration of the CFA may be primarily due to the resonance between the CFA and engine. The Interference among the fan, shroud and radiator by deformation is considered when the CFA is designed. In this paper, in order to analyze the structural vibration of the CFA for automobiles, a finite element model of the CFA is established by using a commercial FEM code. After the finite element modeling, the natural frequencies and the mode shapes are obtained from the FE analysis. The natural frequencies are obtained from the vibration test as well. Then, the results of the vibration test are compared with those of the FE analysis. The natural frequencies obtained by experiment have a great similarity to the results from FE model. We have confirmed the validity of the FE model and verify the structural safety for the resonance. The stress and displacements are obtained from FE analysis. We have confirmed the safety for the interference and failure.

  • PDF

A Study on Structural Strength Assessment of Polyethylene Boat (폴리에틸렌 보트의 구조강도 평가에 관한 연구)

  • Cho, Seok-Swoo;Kwak, Won-Min;Ham, Bum-Sik;Jo, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.3
    • /
    • pp.1045-1053
    • /
    • 2013
  • Boat or yacht hull has been built mainly by FRP composite materials. FRP boat hull manufacturing begins to be restricted after the year 2000 under international regulation on ocean environment safety. The alternative of FRP has been proposed by many boat builders and high strength aluminium is considered as its standard material. But high strength aluminium is very expensive as boat hull material. In this study, boat hull is considered to be built by high density polyethylene and its structural strength is estimated by longitudinal strength test method on small craft. Tensile strength of polyethylene boat hull material is higher than that of FRP boat hull material. But safety factor of polyethylene boat hull is more than that of FRP boat hull. These study results indicate structural integrity and quality control of polyethylene boat is better than those of FRP boat.

The Relationships Among Occupational Safety Climate, Patient Safety Climate, and Safety Performance Based on Structural Equation Modeling

  • Aghaei, Hamed;Asadi, Zahra Sadat;Aliabadi, Mostafa Mirzaei;Ahmadinia, Hassan
    • Journal of Preventive Medicine and Public Health
    • /
    • v.53 no.6
    • /
    • pp.447-454
    • /
    • 2020
  • Objectives: The aim of the present study was to investigate the relationships among hospital safety climate, patient safety climate, and safety outcomes among nurses. Methods: In the current cross-sectional study, the occupational safety climate, patient safety climate, and safety performance of nurses were measured using several questionnaires. Structural equation modeling was applied to test the relationships among occupational safety climate, patient safety climate, and safety performance. Results: A total of 211 nurses participated in this study. Over half of them were female (57.0%). The age of the participants tended to be between 20 years and 30 years old (55.5%), and slightly more than half had less than 5 years of work experience (51.5%). The maximum and minimum scores of occupational safety climate dimensions were found for reporting of errors and cumulative fatigue, respectively. Among the dimensions of patient safety climate, non-punitive response to errors had the highest mean score, and manager expectations and actions promoting patient safety had the lowest mean score. The correlation coefficient for the relationship between occupational safety climate and patient safety climate was 0.63 (p<0.05). Occupational safety climate and patient safety climate also showed significant correlations with safety performance. Conclusions: Close correlations were found among occupational safety climate, patient safety climate, and nurses' safety performance. Therefore, improving both the occupational and patient safety climate can improve nurses' safety performance, consequently decreasing occupational and patient-related adverse outcomes in healthcare units.

Foam Filling Effect on Bending Collapse Characteristics for Member Section Type (부재단면 형상에 따른 부재 굽힘붕괴 특성의 폼 충진 효과)

  • Lee, Il-Seok;Kang, Sung-Jong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.2
    • /
    • pp.41-49
    • /
    • 2007
  • More diversified and strengthened safety regulations require higher safety vehicle with less weight. The structural foam can play a role for restraining section distortion of main body members undergoing bending collapse at vehicle crash. In this study, using structural foam modeling technology, validated in previous work, the bending collapse characteristics were evaluated for two types of circular and actual vehicle body frame sections. With changing the foam filling method, outer panel thickness and section shape, load carrying capability and absorbed energy were observed. The results indicate valuable design strategy for effectively elevating bending collapse performance of body members with foam filled.

Fire Resistance Evaluation of SLIM AU Composite Beam (슬림 AU 합성보 내화성능 평가)

  • Oh, Myoung-Ho;Kim, Myeong-Han
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.4
    • /
    • pp.53-58
    • /
    • 2016
  • SLIM AU(A plus U-shaped) composite beam was developed for reducing the story height in the residential buildings, and saving the cosrtuction cost of floor structures. Structural performance and economic feasibility of the composite beam have been sufficiently approved through the structural experiments and the analytical studies. However, the verification for fire safety is necessary for the practical application of the composite beam. The fire resistance tests with and without loading were performed for the fire safety verification, and the test results were summarized in this paper.