• 제목/요약/키워드: Structural load modeling

검색결과 387건 처리시간 0.027초

설계차량하중 변화에 따른 교량상 장대레일 궤도의 부가축응력 (Additional Axial Stress of CWR Track on the Bridge according to the Variation of Design Vehicle Load)

  • 윤경민;전병흔;최신형;임남형
    • 한국산학기술학회논문지
    • /
    • 제16권1호
    • /
    • pp.807-813
    • /
    • 2015
  • 교량상의 장대레일은 궤도-교량상호작용에 의해 토노반상의 장대레일에 비해 복잡한 거동을 보인다. 궤도-교량 상호작용에 영향을 미치는 요인은 온도변화와 차량하중이다. 국내 철도설계지침 KR C-08080에서는 해석 시 사용하는 물성치, 모델링 방법, 하중 및 하중 조합 방법 등에 대하여 제시하고 있다. 2014년에 KR C-08080에서 제시된 차량하중이 변경되었다. 본 연구에서는 변경된 차량하중의 영향을 평가하기 위하여 22개 교량에 대한 궤도-교량 상호작용 유한요소 해석을 수행하였다.

Modeling of cyclic joint shear deformation contributions in RC beam-column connections to overall frame behavior

  • Shin, Myoungsu;LaFave, James M.
    • Structural Engineering and Mechanics
    • /
    • 제18권5호
    • /
    • pp.645-669
    • /
    • 2004
  • In seismic analysis of moment-resisting frames, beam-column connections are often modeled with rigid joint zones. However, it has been demonstrated that, in ductile reinforced concrete (RC) moment-resisting frames designed based on current codes (to say nothing of older non-ductile frames), the joint zones are in fact not rigid, but rather undergo significant shear deformations that contribute greatly to global drift. Therefore, the "rigid joint" assumption may result in misinterpretation of the global performance characteristics of frames and could consequently lead to miscalculation of strength and ductility demands on constituent frame members. The primary objective of this paper is to propose a rational method for estimating the hysteretic joint shear behavior of RC connections and for incorporating this behavior into frame analysis. The authors tested four RC edge beam-column-slab connection subassemblies subjected to earthquake-type lateral loading; hysteretic joint shear behavior is investigated based on these tests and other laboratory tests reported in the literature. An analytical scheme employing the modified compression field theory (MCFT) is developed to approximate joint shear stress vs. joint shear strain response. A connection model capable of explicitly considering hysteretic joint shear behavior is then formulated for nonlinear structural analysis. In the model, a joint is represented by rigid elements located along the joint edges and nonlinear rotational springs embedded in one of the four hinges linking adjacent rigid elements. The connection model is able to well represent the experimental hysteretic joint shear behavior and overall load-displacement response of connection subassemblies.

페리다이나믹 이론 모델을 이용한 재료의 균열 진전 해석 (Peridynamic Modeling for Crack Propagation Analysis of Materials)

  • 정원준;;이제명
    • 한국전산구조공학회논문집
    • /
    • 제31권2호
    • /
    • pp.105-114
    • /
    • 2018
  • 본 연구에서 페리다이나믹 이론 모델을 이용하여 준정적하중과 동적 하중, 균열전파와 분기균열 패턴 그리고 등방성재료, 직교 이방성 재료의 균열 진전 해석 등 다양한 조건을 고려한 전산 시뮬레이션을 수행하여 그 적합성을 검토하였다. 초기 균열은 없지만 중심에 홀이 있는 등방성 재료, 초기 균열이 존재하는 등방성 및 이방성 재료에 대한 전산 시뮬레이션이 수행되었다. 조정 동적 완화 기법이 사용되어 준정적 하중을 모사하였고, 이방성 재료 해석에서는 고전 연속체 역학과 페리다이나믹의 변형률 에너지를 고려한 균질화 방법이 사용되었다. 균열 전파와 분기 균열이 성공적으로 확인되었으며 파괴 거동의 시작과 그 방향 역시 페리다이나믹 이론으로 확인되었다. 페리다이나믹을 균질화 방법을 사용하여 비교적 복잡한 이방성 재료에 적용한 경우 역시 실험 결과 값과 비교하여 검증하였다.

Influence of shear bolt connections on modular precast steel-concrete composites for track support structures

  • Mirza, Olivia;Kaewunruen, Sakdirat
    • Steel and Composite Structures
    • /
    • 제27권5호
    • /
    • pp.647-659
    • /
    • 2018
  • Through extensive research, there exist a new type of connection between railway bridge girders and steel-concrete composite panels. In addition to conventional shear connectors, newly developed blind bolts have been recently adopted for retrofitting. However, the body of knowledge on their influence and application to railway structures has not been thoroughly investigated. This study has thus placed a particular emphasis on the application of blind bolts on the Sydney Harbour Bridge as a feasible alternative constituent of railway track upgrading. Finite element modeling has been used to simulate the behaviours of the precast steel-concrete panels with common types of bolt connection using commercially available package, ABAQUS. The steel-concrete composite track slabs have been designed in accordance with Australian Standards AS5100. These precast steel-concrete panels are then numerically retrofitted by three types of most practical bold connections: head studded shear connector, Ajax blind bolt and Lindapter hollow bolt. The influences of bolt connections on load and stress transfers and structural behaviour of the composite track slabs are highlighted in this paper. The numerical results exhibit that all three bolts can distribute stresses effectively and can be installed on the bridge girder. However, it is also found that Lindapter hollow bolts are superior in minimising structural responses of the composite track slabs to train loading.

단위부재 모델화에 따른 단층 래티스 돔의 탄소성 좌골하중의 산정에 관한 연구 (A Study on the Estimation of Elasto-Plastic Buckling Loads for Sing1e Layer Latticed Domes by Unit Member Modeling Technique.)

  • 한상을;이상주;유용주;이경수
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 가을 학술발표회 논문집
    • /
    • pp.290-297
    • /
    • 1998
  • In this paper, we propose to a method to estimate the elasto-plastic buckling for single layer latticed domes. First, we assume that each member consists of the rigid zone and elastic spring at both end joint, the elastic element and three elasto-plastic spring to judge for yeilding the member. Next, the member which has most influence on buckling for structures is determined by a distributed pattern of the strain energy which is calculated through linear eigenvalue analysis. And then, normalized slenderness ratio of the element is derived considering the axial force at elastic buckling load. Later, we execute elasto-plastic nonlinear analysis that based on loading increasement method and displacement increasement method. From this results, we discusses the effect of the joint rigidity and the half open angle $\theta$$_{0}$ on the buckling strength of single layer lattice domes ; (1) how the joint rigidity contributes to the reduction of buckling loads, (2) how the reduction can be interrelated to compressive strength curves in terms of the generalized slenderness for the member most relevant to the overall buckling of domes.s.

  • PDF

Column design of cold-formed stainless steel slender circular hollow sections

  • Young, Ben;Ellobody, Ehab
    • Steel and Composite Structures
    • /
    • 제6권4호
    • /
    • pp.285-302
    • /
    • 2006
  • This paper describes the design and behaviour of cold-formed stainless steel slender circular hollow section columns. The columns were compressed between fixed ends at different column lengths. The investigation focused on large diameter-to-plate thickness (D/t) ratio ranged from 100 to 200. An accurate finite element model has been developed. The initial local and overall geometric imperfections have been included in the finite element model. The material nonlinearity of the cold-formed stainless steel sections was incorporated in the model. The column strengths, load-shortening curves as well as failure modes were predicted using the finite element model. The nonlinear finite element model was verified against test results. An extensive parametric study was carried out to study the effects of cross-section geometries on the strength and behaviour of stainless steel slender circular hollow section columns with large D/t ratio. The column strengths predicted from the parametric study were compared with the design strengths calculated using the American Specification, Australian/New Zealand Standard and European Code for cold-formed stainless steel structures. It is shown that the design strengths obtained using the Australian/New Zealand and European specifications are generally unconservative for the cold-formed stainless steel slender circular hollow section columns, while the American Specification is generally quite conservative. Therefore, design equation was proposed in this study.

Design analysis of the optimum configuration of self-anchored cable-stayed suspension bridges

  • Lonetti, Paolo;Pascuzzo, Arturo
    • Structural Engineering and Mechanics
    • /
    • 제51권5호
    • /
    • pp.847-866
    • /
    • 2014
  • This paper describes a formulation to predict optimum post-tensioning forces and cable dimensioning for self-anchored cable-stayed suspension bridges. The analysis is developed with respect to both dead and live load configurations, taking into account design constrains concerning serviceability and ultimate limit states. In particular, under dead loads, the analysis is developed with the purpose to calculate the post-tensioning cable forces to achieve minimum deflections for both girder and pylons. Moreover, under live loads, for each cable elements, the lowest required cross-section area is determined, which verifies prescriptions, under ultimate or serviceability limit states, on maximum allowable stresses and bridge deflections. The final configuration is obtained by means of an iterative procedure, which leads to a progressive definition of the stay, hanger and main cable characteristics, concerning both post-tensioning cable stresses and cross-sections. The design procedure is developed in the framework of a FE modeling, by using a refined formulation of the bridge components, taking into account of geometric nonlinearities involved in the bridge components. The results demonstrate that the proposed method can be easily utilized to predict the cable dimensioning also in the framework of long span bridge structures, in which typically more complexities are expected in view of the large number of variables involved in the design analysis.

수중폭발 충격하중을 받는 잠수함 액화산소 탱크의 구조-유체 상호작용 기법에 관한 연구 (A Study of Structure-Fluid Interaction Technique for Submarine LOX Tank under Impact Load of Underwater Explosion)

  • 김재현;박명규
    • 한국해양공학회지
    • /
    • 제19권1호
    • /
    • pp.20-25
    • /
    • 2005
  • The authors performed the underwater explosion analysis for the liquified oxygen tank - a kind of fuel tank of a mid-size submarine, and tried to verify the structural safety for this structure. First, the authors reviewed the theory and application of underwater explosion analysis, using a Structure-Fluid Interaction technique and its finite element modeling scheme. Next, the authors modeled the explosive and sea water as fluid elements, the LOX tank as structural elements, and the interface between the two regions as the ALE scheme. The effect on shock pressure and impulse of fluid mesh size and shape are also investigated. Upon analysis, it was found that the shock pressure due to explosion propagated into the water region, and hit the structure region. The plastic deformation and the equivalent stress were apparent at the web frame and the shock mount of LOX structure, but these values were acceptable for the design criteria.

고소작업대의 파손된 고정볼트의 피로분석에 관한 연구 (A Fatigue Analysis Study on the Fractured Fixing Bolts of Mobile Elevated Work Platforms)

  • 최동훈;김재훈
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.1-6
    • /
    • 2019
  • The mobile elevated work platforms(MEWPs) consist of work platform, extending structure, and car, and it is a facility to move persons to working positions. MEWPs are useful but composed complex pieces of equipments, and accidents are caused by equipment defects. Among them, accidents caused by fracture of the bolts fixing the extension structure and the turntable are increasing. In this study, fatigue failure and fatigue life of a turntable fixing bolt subjected to irregular fatigue load were analyzed by FEA. For this purpose, finite element modeling is proposed and structural analysis and fatigue analysis are performed simultaneously for fixing bolts. As a result of the structural analysis, it was confirmed that there is no risk of permanent deformation because the maximum stress acting on the fixing bolt is lower than the yield strength, and fatigue analysis was confirmed that the fatigue life is less than the design standard. The fatigue analysis results of this study can be effectively used for the design and the documentary assessment of the safety certification of the MEWPs by examining the fatigue life of the turntable fixing bolt.

전투기 AESA 레이더 운용모드의 최적 계층구조 설계 방법론 (Optimal Hierarchical Design Methodology for AESA Radar Operating Modes of a Fighter)

  • 김흥섭;김성호;장우석;설현주
    • 산업경영시스템학회지
    • /
    • 제46권4호
    • /
    • pp.281-293
    • /
    • 2023
  • This study addresses the optimal design methodology for switching between active electronically scanned array (AESA) radar operating modes to easily select the necessary information to reduce pilots' cognitive load and physical workload in situations where diverse and complex information is continuously provided. This study presents a procedure for defining a hidden Markov chain model (HMM) for modeling operating mode changes based on time series data on the operating modes of the AESA radar used by pilots while performing mission scenarios with inherent uncertainty. Furthermore, based on a transition probability matrix (TPM) of the HMM, this study presents a mathematical programming model for proposing the optimal structural design of AESA radar operating modes considering the manipulation method of a hands on throttle-and-stick (HOTAS). Fighter pilots select and activate the menu key for an AESA radar operation mode by manipulating the HOTAS's rotary and toggle controllers. Therefore, this study presents an optimization problem to propose the optimal structural design of the menu keys so that the pilot can easily change the menu keys to suit the operational environment.