• Title/Summary/Keyword: Strong ion difference

Search Result 33, Processing Time 0.026 seconds

Removal of Nitrate-Nitrogen in Pickling Acid Wastewater from Stainless Steel Industry Using Electrodialysis and Ion Exchange Resin (전기투석과 이온교환수지를 이용한 스테인레스 산업의 산세폐수 내 질산성 질소의 제거)

  • Yun, Young-Ki;Park, Yeon-Jin;Oh, Sang-Hwa;Shin, Won-Sik;Choi, Sang-June;Ryu, Seung-Ki
    • Journal of Environmental Science International
    • /
    • v.18 no.6
    • /
    • pp.645-654
    • /
    • 2009
  • Lab-scale Electrodialysis(ED) system with different membranes combined with before or after pyroma process were carried out to remove nitrate from two pickling acid wastewater containing high concentrations of $NO_3\;^-$(${\approx}$150,000 mg/L) and F($({\approx}$ 160,000 mg/L) and some heavy metals(Fe, Ti, and Cr). The ED system before Pyroma process(Sample A) was not successful in $NO_3\;^-$ removal due to cation membrane fouling by the heavy metals, whereas, in the ED system after Pyroma process(Sample B), about 98% of nitrate was removed because of relatively low $NO_3\;^-$ concentration (about 30,000 mg/L) and no heavy metals. Mono-selective membranes(CIMS/ACS) in ED system have no selectivity for nitrate compared to divalent-selective membranes(CMX/AMX). The operation time for nitrate removal time decreased with increasing the applied voltage from 10V to 15V with no difference in the nitrate removal rate between both voltages. Nitrate adsorption of a strong-base anion exchange resin of $Cl\;^-$ type was also conducted. The Freundlich model($R^2$ > 0.996) was fitted better than Langmuir mode($R^2$ > 0.984) to the adsorption data. The maximum adsorption capacity ($Q^0$) was 492 mg/g for Sample A and 111 mg/g for Sample B due to the difference in initial nitrate concentrations between the two wastewater samples. In the regeneration of ion exchange resins, the nitrate removal rate in the pickling acid wastewater decreased as the adsorption step was repeated because certain amount of adsorbed $NO_3\;^-$ remained in the resins in spite of several desorption steps for regeneration. In conclusion, the optimum system configuration to treat pickling acid wastewater from stainless-steel industry is the multi-processes of the Pyroma-Electrodialysis-Ion exchange.

Acid/base alterations during major abdominal surgery: 6% hydroxyethyl starch infusion versus 5% albumin

  • Kwak, Hyun Jeong;Lim, Oh Kyung;Baik, Jae Myung;Jo, Youn Yi
    • Korean Journal of Anesthesiology
    • /
    • v.71 no.6
    • /
    • pp.459-466
    • /
    • 2018
  • Background: To compare the effects of intraoperative infusions of balanced electrolyte solution (BES)-based hydroxyethyl starch (HES) and saline-based albumin on metabolic acidosis and acid/base changes during major abdominal surgery conducted using Stewart's approach. Methods: Forty patients, aged 20-65 years, undergoing major abdominal surgery, were randomly assigned to the HES group (n = 20; received 500 ml of BES-based 6% HES 130/0.4) or the albumin group (n = 20; received 500 ml of normal saline-based 5% albumin). Acid-base parameters were measured and calculated using results obtained from arterial blood samples taken after anesthesia induction (T1), 2 hours after surgery commencement (T2), immediately after surgery (T3), and 1 hour after arriving at a postanesthetic care unit (T4). Results: Arterial pH in the HES group was significantly higher than that in the albumin group at T3 ($7.40{\pm}0.04$ vs. $7.38{\pm}0.04$, P = 0.043), and pH values exhibited significant intergroup difference over time (P = 0.002). Arterial pH was significantly lower at T3 and T4 in the HES group and at T2, T3, and T4 in the albumin group than at T1. Apparent strong ion difference (SIDa) was significantly lower at T2, T3, and T4 than at T1 in both groups. Total plasma weak nonvolatile acid ($A_{TOT}$) was significantly lower in the HES group than in the albumin group at T2, T3 and T4 and exhibited a significant intergroup difference over time (P < 0.001). Conclusions: BES-based 6% HES infusion was associated with lower arterial pH values at the end of surgery than saline-based 5% albumin infusion, but neither colloid caused clinically significant metabolic acidosis (defined as an arterial pH < 7.35).

Polarity-tuned Gel Polymer Electrolyte Coating of High-voltage LiCoO2 Cathode Materials

  • Park, Jang-Hoon;Cho, Ju-Hyun;Kim, Jong-Su;Shim, Eun-Gi;Lee, Yun-Sung;Lee, Sang-Young
    • Journal of the Korean Electrochemical Society
    • /
    • v.14 no.2
    • /
    • pp.117-124
    • /
    • 2011
  • We demonstrate a new surface modification of high-voltage lithium cobalt oxide ($LiCoO_2$) cathode active materials for lithium-ion batteries. This approach is based on exploitation of a polarity-tuned gel polymer electrolyte (GPE) coating. Herein, two contrast polymers having different polarity are chosen: polyimide (PI) synthesized from thermally curing 4-component (pyromellitic dianhydride/biphenyl dianhydride/phenylenediamine/oxydianiline) polyamic acid (as a polar GPE) and ethylene-vinyl acetate copolymer (EVA) containing 12 wt% vinyl acetate repeating unit (as a less polar GPE). The strong affinity of polyamic acid for $LiCoO_2$ allows the resulting PI coating layer to present a highly-continuous surface film of nanometer thickness. On the other hand, the less polar EVA coating layer is poorly deposited onto the $LiCoO_2$, resulting in a locally agglomerated morphology with relatively high thickness. Based on the characterization of GPE coating layers, their structural difference on the electrochemical performance and thermal stability of high-voltage (herein, 4.4 V) $LiCoO_2$ is thoroughly investigated. In comparison to the EVA coating layer, the PI coating layer is effective in preventing the direct exposure of $LiCoO_2$ to liquid electrolyte, which thus plays a viable role in improving the high-voltage cell performance and mitigating the interfacial exothermic reaction between the charged $LiCoO_2$ and liquid electrolytes.

Modeling of Carbon Plume in PLAD Method Assisted by Ar Plasmas (Ar 플라즈마 상태에서 PLAD법에 의한 탄소 입자의 운동 모델링)

  • So, Soon-Youl;Lim, Jang-Seob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.4
    • /
    • pp.24-31
    • /
    • 2005
  • A plused laser ablation deposition(PLAD) technique has been used for producing fine particle as well as thin film at relatively low substrate temperatures. However, in order to manufacture and evaluate such materials in detail, motions of plume particles generated by laser ablation have to be understood and interactions between the particles by ablation and gas plasma have to be clarified. Therefore this paper was focused on the understanding of plume motion in laser ablation assisted by hi plasmas at 100[mTorr]. One-dimensional hybrid model consisting of fluid and particle models was developed and three kinds of plume particles which are carbon atom(C), $ion(C^+)$ and electron were considered in the calculation of particle method. It was obtained that ablated $C^+$ was electrically captured in Ar plasmas by strong electric field(E). The difference between motions of the ablated electrons and $C^+$ made E strong and the collisional processes active. The energies of plume particles were investigated on a substrate surface. In addition the plume motion in Ar gas was also calculated and discussed.

Study on the Quantitativity of Image Sticking in the Fringe-field Switching(FFS) Mode (Fringe-Field Switching (FFS) 모드에서 잔상 정량화에 관한 연구)

  • Seen, Seung-Min;Kim, Mn-Sook;Jung, Yeon-Hak;Kim, Hyang-Yul;Kim, Seo-Yoon
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.8
    • /
    • pp.720-723
    • /
    • 2005
  • We studied the quantitativity of the image sticking which is occured by the resicual DC in the fringe-electric field switching (FFS) mode. Actually, in the FFS mode driven by the strong fringe electric field, the asymmetric residual DC was formed in the bottom substrate. It made the impurity ion stick to the alignment layer such as polyimde layer. Thus, the differnece of the luminance existes after the stress check pattern is applied to the panel so that we can see the image sticking. This image sticking decreases as the residual DC value between specific patterns decreases. Therefore, it is necessary to control the residual DC for the FFS mode with the high image quality. It is possible to eliminate the image stiking when the extra pixel voltage is applied through the circuit tunning for reducing the difference of residual DC accroding to the panel position.

Change in Germination and Physiological Properties of Hippophae rhamnoides Seeds by Different Storage Period (갈매보리수나무 종자의 저장기간에 따른 발아 및 생리적 특성)

  • Choi, Chung Ho;Yang, Byeong Hoon
    • Korean Journal of Plant Resources
    • /
    • v.28 no.4
    • /
    • pp.533-540
    • /
    • 2015
  • Germination properties, leachate electrical conductivity (EC), and inorganic compound leaching were analyzed to ascertain the storage ability and change of physiological characteristics during storage of Hippophae rhamnoides seeds. Seeds were placed in an incubator at 25℃ and sown in different soil media (sand, vermiculite and horticultural substrate) after being stored for 6, 18 and 30 months at 2℃. All germination properties decreased in accordance to an increase of the seed storage period. Compared with the seed storage for 18 months, germination percentage (GP), germination performance index (GPI), and germination value (GV) of seeds stored for 30 months decreased by more than 50%. When the seeds were sown in different soil media in a greenhouse, those germination properties were similar to the seeds germinated in an incubator, and mean germination time, GPI and GV had a significant difference except GP among soil media. EC and inorganic ion concentration had a strong positive correlation with the seed storage period, but the ratios of inorganic ions from stored seeds revealed that K+/Mg2+ and Na+/Mg2+ were inversely correlated with the storage period.

Sensing NO3-N and K Ions in Hydroponic Solution Using Ion-Selective Membranes (이온선택성 멤브레인을 이용한 양액 내 질산태 질소 및 칼륨 측정)

  • Kim, Won-Kyung;Park, Tu-San;Kim, Young-Joo;Roh, Mi-Young;Cho, Seong-In;Kim, Hak-Jin
    • Journal of Biosystems Engineering
    • /
    • v.35 no.5
    • /
    • pp.343-349
    • /
    • 2010
  • Rapid on-site sensing of nitrate-nitrogen and potassium ions in hydroponic solution would increase the efficiency of nutrient use for greenhouse crops cultivated in closed hydroponic systems while reducing the potential for environmental pollution in water and soil. Ion-selective electrodes (ISEs) are a promising approach because of their small size, rapid response, and the ability to directly measure the analyte. The capabilities of the ISEs for sensing nitrate and potassium in hydroponic solution can be affected by the presence of other ions such as calcium, magnesium, sulfate, sodium, and chloride in the solution itself. This study was conducted to investigate the applicability of two ISEs consisting of TDDA-NPOE and valinomycin-DOS PVC membranes for quantitative determinations of $NO_3$-N and K in hydroponic solution. Nine hydroponic solutions were prepared by diluting highly concentrated paprika hydroponic solution to provide a concentration range of 3 to 400 mg/L for $NO_3$-N and K. Two of the calibration curves relating membrane response and nutrient concentration provided coefficients of determination ($R^2$) > 0.98 and standard errors of calibration (SEC) of < 3.79 mV. The use of the direct potentiometry method, in conjunction with an one-point EMF compensation technique, was feasible for measuring $NO_3$-N and K in paprika hydroponic solution due to almost 1:1 relationships and high coefficients of determination ($R^2$ > 0.97) between the levels of $NO_3$-N and K obtained with the ion-selective electrodes and standard instruments. However, even though there were strong linear relationships ($R^2$ > 0.94) between the $NO_3$-N and K concentrations determined by the Gran's plot-based multiple standard addition method and by standard instruments, hydroponic $NO_3$-N concentrations measured with the ISEs, on average, were about 10% higher than those obtained with the automated analyzer whereas the K ISE predicted about 59% lower K than did the ICP spectrometer, probably due to no compensation for a difference between actual and expected concentrations of standard solutions directly prepared.

Field Validation of an IC/Visible Spectrophotometry Method for the Determination of Cr(VI) in Mist (미스트중 6가 크롬 측정을 위한 IC/Visible Spectrophotometry 방법 (Shin & Paik′s Method)의 현장 평가)

  • 신용철;백남원;김상우;김선자;이유미
    • Proceedings of the Korean Environmental Health Society Conference
    • /
    • 2002.04a
    • /
    • pp.40.1-43
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of hexavalent chromium, Cr(VI) in mist from field plating operation. The Procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute for Occupational Safety and Health (NIOSH) Method 7600, and the filter sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(VI) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(VI) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(VI) on PVC filters and storing the sample filters in screw-capped vials according to the NIOSH method, and analyzing Cr(VI) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(VI) into 0.02 MN/sub a/Hco₃ solution in midget impinger, and analyzing the Cr(VI) in samples using IC/VS. The third method was the OSHA Method Id-215. Using these four different methods, four replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and Paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r/sup 2/=0.99) between Cr(VI) concentrations measured by the shin & Paik's Method and an impinger method (p>0.05). However, Cr(VI) concentrations determined by Shin & Paik's Method were Significantly different form those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(VI) concentrations of Shin & Paik's Method were Significantly higher than those of the NIOSH/EPA Method or the OSHA method. We concluded that the Shin & Paik's Method could prevent Cr(VI) losses caused by reduction and give more reliable results of airborne Cr(VI) concentrations in work environments.

  • PDF

Field Validation of a Sampling and Analytical Method Developed for Preventing Airborne Hexavalent Chromium Collected on PVC Filter from Reduction (PVC 여과지에서의 환원 방지를 위해 개발된 공기중 6가 크롬 측정방법의 현장 평가)

  • 신용철;백남원
    • Journal of Environmental Health Sciences
    • /
    • v.28 no.2
    • /
    • pp.109-116
    • /
    • 2002
  • The purpose of this study was to evaluate a new sampling and analytical method for the determination of airborne hexavalent chromium, Cr(Ⅵ), in a field plating operation. The procedures of this new method (Shin & Paik's Method) are as the following: Airborne hexavalent chromium is collected on polyvinyl chloride (PVC) filter according to the National Institute iota Occupational Safety and Health (NIOSH) Method 7600, and the filler sample is placed in a screw-capped vial and soaked with 2% NaOH/3% Na₂CO₃ solution immediately after sampling. The Cr(Ⅵ) sample is analyzed by ion chromatography/visible spectrophotometry (IC/VS) according to the U.S. Environmental Protection Agency (EPA) Method 218.6. The airborne Cr(Ⅵ) concentrations measured by this method were compared with those determined by three reference methods: One (NIOSH/EPA Method) consisted of sampling airborne Cr(Ⅵ) on PVC filters and storing the sample filters in strew-capped vials according to the NIOSH method, and analyzing Cr(Ⅵ) in samples using IC/VS according to the EPA method. The second method (Impinger Method/NaHCO₃) consisted of absorbing airborne Cr(Ⅵ) into 0.02 M NaHCO₃ solution in midget impinger, and analyzing the Cr(Ⅵ) in samples using IC/VS. The third method was the OSHA Method ID-215. Using these four different methods, lour replicates of air samples were collected at an electroplating process and analyzed simultaneously. Two-way ANOVA and paired t-test were used to test difference among values determined by the methods. There was no significant difference and a strong correlation (r²:0.99) between Cr(Ⅵ) concentrations measured by the Shin & Paik's Method and an impinger method (p>0.05). However, Cr(Ⅵ) concentrations determined by Shin & Paik's Method were significant1y different from those by the NIOSH/EPA Method (p<0.05) or the OSHA method (p<0.05). The Cr(Ⅵ) concentrations of Shin & Paik's Method were significantly higher than those of the NIOSH/EPA Method or the OSHA method. This result indicated that the Shin & Paik's Method may prevent Cr(Ⅵ) losses caused by reduction and give more reliable results of airborne Cr(Ⅵ) concentrations in work environments.

A Fundamental Study of Eu2+ Luminescence in Aluminum Borate Compounds (Aluminum Borate 화합물에 있어서 EU2+이온의 발광성)

  • Chang, Ki-Seog
    • Journal of the Korean Chemical Society
    • /
    • v.44 no.4
    • /
    • pp.350-355
    • /
    • 2000
  • The compounds, CaAl$_2$(BO$_3$)$_2$O, SrAl$_2$(BO$_3$)$_2$O and BaAl$_2$(BO$_3$)$_2$O, are good host lattices for highly efficient $Eu^{2+}$ luminescence. The europium emission peaks at 450 nm in $Eu^{2+}$:CaAl$_2$(B0$_3$)$_2$O, 411 nm in $Eu^{2+}$: SrAl$_2$(BO$_3$)$_2$O and 375 nm in $Eu^{2+}$: BaAl$_2$(BO$_3$)$_2$O. The $Eu^{2+}$: CaAl$_2$(BO$_3$)$_2$O Phosphor shows a high output and should be a good maintenance in VUV Xe lamps. It is ideally suited for use in PDP phosphors. The $Eu^{2+}$ ion is interesting because the Stokes shift emission is a strong host dependent. The difference in the Stokes shift is oneimportant factor leadingto a difference in wavelength. If the 5d level of $Eu^{2+}$ ion is lower in energy,according to a decrease in the doping lattice size, then the emission wavelength will be longer and the Stokes shift will be smaller. Therefore, a knowledge of the relationship between the crystal lattice size and the Stokes shift. (orthe energy of the 5d level),is essential for beingable to predict $Eu^{2+}$ emission properties.

  • PDF