• Title/Summary/Keyword: Strip Profile

Search Result 99, Processing Time 0.028 seconds

Comparative study of surface roughness between several finishing and polishing procedures on ormocer-based composite resin and nanohybrid composite resin (복합 레진에서 마무리 방법에 따른 표면 거칠기 비교)

  • Jeong, Suk-In;Oh, Nam-Sik;Lee, Myung-Hyeon;Lee, En-Jung;Cho, Jung-Hyeon;Ji, Sung-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.2
    • /
    • pp.105-115
    • /
    • 2008
  • Statement of problem: Proper finishing and polishing enhance both the esthetics and the longevity of restored teeth. Blade finishing technique would be suited for smoothing and finishing. Evaluation of this technique are necessary. Purpose: The purpose of this study was to evaluate the blade finishing and polishing procedures on the surface profile and roughness of ormocer-based composite resin and nanohybrid composite resin. Material and methods: The material included a ormocer-based composite resin ($Admira^{(R)}$ & $Admira^{(R)}$ Flow); a nanohybrid composite resin ($Grandio^{(R)}$ & $Grandio^{(R)}$ Flow). One hundred forty specimens of each group were prepared using a mylar strip and randomly divied into blade finishing and rubber polishing groups (n=10). The average surface roughness (Ra) in micrometers was measured and the surface profile was examined by scanning electron microscopy (SEM) (Magnification ${\times}$ 200). The data were analyzed by Mann-Whitney Test at 0.05 significance level. Conclusion: The results of this study indicated that the mylar strip produced the smoothest surface on all materials and among the finishing-polishing methods was not significanct difference (P>0.05). Ormocer-based flowable composite resin performedthe lowest variability in initial surface roughness among the tested materials.

Characteristics of Gentamicin Resistant Pseudomonas aeruginosa (녹농균의 항생제 내성의 특성)

  • Kim, Sang-Yoon;Lee, Yoo-Chul;Seol, Sung-Yong;Cho, Dong-Taek;Chun, Do-Ki
    • The Journal of the Korean Society for Microbiology
    • /
    • v.21 no.1
    • /
    • pp.1-16
    • /
    • 1986
  • Fifty-one strains of Pseudomonas aeruginosa were isolated from various clinical specimens. Among them, 26 (51%) strains were gentamicin-resistant (Gm') and 25 (49%) were susceptible to gentamicin (Gm'). The frequencies of resistant strains to piperacillin (Pi), cefotaxime, moxalactam, cefoperazone (Cz), and amikacin (Ak) ranged from 21.6 to 31.4%, and $MIC_{50}$ of these drugs were lower than the critical concentrations of susceptibility and resistance. Thirty (58.8%) strains were multiply resistant to 12 or more drugs. All Gm' strains were multiply resistant to 12 or more drugs and one was resistant to all 18 drugs tested, while only four Gm' strains were multiply resistant to 12 drugs and the multiplicity of resistance of the other Gm' strains were less than 10 drugs. Resistance to Gm appeared to have a significant correlation with the resistance to tobramycin (Tb), Ak, Pi, and Cz. All Gm' strains were resistant to Tb and about 38.4 to 46.1% of them were resistant to Ak, Pi, and Cz. The incorporation of $Ca^{++}$ and $Mg^{++}$ ions in Mueller-Hinton agar (MHA) did not influence the MICs of Gm, Tb, carbenicillin (Cb), Pi, and Cz as compared with the results obtained in MHA without these ions. Gm strains were studied on the combined effect of beta-lactam antibiotics and aminoglycosides by the methods of checkerboard and modified paper strip diffusion. Most Gm' strains showed significant synergistic effects by the FIC index between Ak and three beta-lactam antibiotics; Cb, Pi, and Cz, but these results did not in agreement the results obtained through the method of modified paper strip diffusion test. In order to know the nature of the drug resistance of P. aernginosa, the plasmid profile analysis was studied. Agarose gel electrophoresis of lysates processed by the method of Kado and Liu showed one or more plasmids in 22 (43.1%) strains. A group of 19 strains showed at least one band of plasmid and three strains two bands. The range of the molecular weight of plasmids was 3.8 to 243 Mdal. All strains carrying large plasmids larger than 200 Mdal were isolated from wound specimens. Three Gm' strains also harboured the plasm ids of 13 to 203 Mdal.

  • PDF

Design of the anvil shape in sizing press for decrease of the defect generated width reduction (사이징 프레스에서 폭 압하 공정중 결함 감소를 위한 엔빌의 형상설계)

  • Lee S.H.;Kim D.H.;Byon S.M.;Park H.D.;Kim B.M.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.437-438
    • /
    • 2006
  • Generally, the vertical roll process is used to achieve extensive width reduction in hot strip mill. However, it is difficult to avoid the defects such as dog-bone and seam-defect. The sizing press has been developed in response to the defects mentioned above. Especially, this study is carried out to investigate the deformation of slab by two-step sizing press. The deformation behavior in the width sizing process is more favorable than that in conventional vertical rolling edger. The objective of this study is to determine the optimal anvil shape parameters in the sizing press with two-step die from the viewpoint of edge-seam length. In general, the edge-seam defect occurs parallel to the rolling direction at both edges in horizontal rolling process after sizing press. The optimal combination of the parameters is determined by FE-simulation and Artificial Neural Network (ANN). The slab deformation in sizing press with convex anvil is analyzed by FE-simulation. The most suitable profile of the anvil is also discussed fur the improvement of trimming loss because of the side seam defect by FE-simulation and ANN.

  • PDF

The Analysis of Seminal Plasma Proteins by Two-Dimensional Polyacrylamide Gel Electrophoresis (2-DE) in Hanwoo (Korean Native Cattle)

  • Lee, Yong-Seung;Song, Eun-Ji;Yoo, Han-Jun;Park, Joung-Jun;Cheong, Hee-Tae;Yang, Boo-Keun;Park, Choon-Keun
    • Journal of Embryo Transfer
    • /
    • v.25 no.4
    • /
    • pp.281-286
    • /
    • 2010
  • This study was to evaluate the protein profile of seminal plasma using 2-DE in Hanwoo. Seminal plasma was harvested from five mature Hanwoo, and seminal plasma protein was extracted by M-PER Mammalian Protein Extraction Reagent. Proteins were refined by clean-up kit and quantified by Bradford method until total protein was $300\;{\mu}l$. Immobilized pH gradient (IPG) strip was used 18 cm and 3~11 NL. SDS-PAGE was used 12% acrylamide gel. Each gels were visualized by comassie brilliant blue and silver staining. These spots were analyzed by MALDI-TOF MS and searched on NCBInr. The result, 20 proteins of 36 protein spots were searched through peptide sequencing on the NCBInr. 8 proteins profiled by 2-DE were proved through previous bovine studies and the name of each protein was albumin, nucleobindin, clusterin, TIMP-2, spermadhesin Z13, spermadhesin-1 and BSP proteins (BSP 30 kDa and BSP A1/A2). 12 new proteins were ATP synthase, protein MAK16 homolog, Transmembrane protein 214, E3 ubiquitin-protein ligase BRE1A, dual serine/threonine and tyrosine protein kinase, tissue factor pathway inhibitor 2, alpha-actinin-4, RUN domain-containing protein 3B, catenin alpha-1, protein-glutamine gamma-glutamyltransferase 2, plakophilin-1 and inter-alpha-trypsin inhibitor heavy chain H1 has not been previously described in the bovine seminal plasma study. These proteins may be contribute to define the type of proteins affecting fertility of male and improve the fertilizing ability of semen in Hanwoo.

Utilizing Advanced Pad Conditioning and Pad Motion in WCMP

  • Kim, Sang-Yong;Chung, Hun-Sang;Park, Min-Woo;Kim, Chang-Il;Chang, Eui-Goo
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.171-175
    • /
    • 2001
  • Chemical mechanical polishing(CMP) process has been widely used to planarize dielectrics and metal, which can apply to employed in integrated circuits for sub-micron technology. Despite the increased use of CMP process, it is difficult to accomplish the global planarization of free-defects in inter level dielectrics and metal. Especially, defects like (micro-scratch) lead to severe circuit failure, and affects yield. Current conditioning method - bladder type, orbital pad motion - usually provides unsuitable pad profile during ex-situ conditioning near the end of pad life. Since much of the pad wear occurs by the mechanism of bladder tripe conditioning and its orbital motion without rotation, we need to implement new ex-situ conditioner which can prevent abnormal regional force on pad caused by bladder-type and also need to rotate the pad during conditioning. Another important study of ADPC is related to the orbital scratch of which source is assumed as diamond grit dropped from the strip during ex-situ conditioning. Scratch from diamond grit damaged wafer severely so usual1y scraped. Figure 1 shows the typical shape of scratch damaged from diamond. We suspected that intensive forces to the edge area of bladder type stripper accelerated the drop of Diamond grit during conditioning, so new designed Flat stripper was introduced.

  • PDF

Comparison of amino acid and free amino acid contents between cap and stipe in Flammulina velutipes and Pleurotus ostreatus (팽이와 느타리버섯 자실체의 갓과 대에서 아미노산 및 유리아미노산 함량 비교)

  • Kim, Jung-Tae;Kim, Mi-Jung;Jhune, Chang-Sung;Shin, Pyung-Gyun;Oh, YounLee;Yoo, Young-Bok;Suh, Jang-Sun;Kong, Won-Sik
    • Journal of Mushroom
    • /
    • v.12 no.4
    • /
    • pp.341-349
    • /
    • 2014
  • The composition and content of amino acid and free amino acid were separately compared in cap and stipe of fruitbody obtained from different color strains in winter mushroom and oyster mushroom strains. The result showed different kinds and amount of amino acids according to the mushroom parts, strains and kinds. Tryptophane was not detected in any mushrooms. Alanine was also not detected in all oyster mushroom strains. The content of glutamic acid was the highest and that of methionine, phenylalanine and cysteine were very low in all mushroom strains. When compared by parts, the ratio of amono acids showed similar tendency in composition. Generally the content of amono acids showed higher in caps than in stipes. The profile and content of free amino acid showed a lot of variation between cap and strip in the intra and inter mushrooms.

Export Competitiveness of Busan Port: Market Comparative Advantage Index (시장비교우위지수를 이용한 부산항의 수출경쟁력 분석)

  • Mo, Soo-Won;Chung, Hong-Young;Lee, Kwang-Bae
    • Journal of Korea Port Economic Association
    • /
    • v.31 no.3
    • /
    • pp.141-153
    • /
    • 2015
  • This paper is an attempt to analyze the comparative advantage of Busan Port to China. For this, we use the market comparative advantage index, which is a version of the revealed comparative advantage index. The market comparative advantage index (MCA) uses trade patterns to identify the sectors in which a region has a comparative advantage, in this case by comparing Busan Port's trade profile with the world average (China). The indices are calculated at the commodity level of the HS four-digit classification. The export data used in this study are obtained from the Korea International Trade Association. Exports to China accounted for almost one third of Korean exports in 2014. There are, however, structural differences among the main export items of Busan Port. This paper, therefore, employs MCA indices to reveal the behaviors of the ten main export items, which are "HS3920-other plates/sheets/film/foil of plastics," "HS7606-aluminum plates/sheets/strip," "HS8479-unspecified machines/medical appliances," "HS8486-machines for semiconductor devices or wafers," "HS8529-parts for transmission apparatus for television," "HS8703-motor vehicles for the transport of persons," "HS8708-parts of motor vehicles," "HS9001-optical fibers," and "HS9013-liquid crystal devices." The study shows that export competitiveness of nine items increases, the exception being HS8703. However, China's import ratios of seven of the nine items for which the MCA indices go up are on the decrease, which means that it would be hard to expand the export market for these seven items, despite the higher MCA indices. Since the shares of the port's total exports to China of HS3907, HS8486, HS8529, HS9001, and HS9013 in total exports to China increase together with China's import ratio decreasing, these items may have promising export markets. MCA increases of HS7606 and HS8479 are attributable to China's lower import ratio, rather than a higher export share, so higher MCA indices do not guarantee higher export competitiveness for these items.

THE EFFECT OF GOLD ELECTROFORMING PROCEDURE ON GOLD-SILVER-PALLADIUM ALLOY

  • Hwang, Bo-Yeon;Kim, Chang-Whe;Lim, Young-Jun;Kim, Myung-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.45 no.3
    • /
    • pp.303-309
    • /
    • 2007
  • Statement of problem. The effect of gold electroforming on gold alloy was not studied. Purpose. This in vitro study investigate the effect of gold electroforming on gold-silver-palladium alloy. Material and methods. Three pieces of gold strips had undergone the electroforming procedures on one side and then half of the side again electroformed. The set mode for this study was program 1 ($200{\mu}m$). And the processing time was 15min (1/20 time to form $200{\mu}m$ coping). The confocal laser scanning microscope (PASCAL 5, Carl Zeiss, Bernried, Germany) was used to measure the thickness of the pure gold layer electroformed on the gold strips. Half of the gold strip was coated two times with electroformed gold, and the other half one time. The data from the cone focal laser system was processed to get the vertical profile of the strips and the difference of the vertical height between the double coated and single coated layer was regarded as the thickness of the gold coating. The layer thickness value to built 3D image of the cone-focal laser was set $0.5{\mu}m$. Next to the measurement of the thickness of the coating, the Vicker's hardness test was done. It was performed on the double coated surface, single coated surface and non-coated surface (back side) three times each. Results. The mean thickness value gained from gold electroforming technique was measured to be $22{\mu}m$ for sample 1, $23{\mu}m$ for sample 2, $21{\mu}m$ for sample 3. In the same condition of time, power and the amount of electrolyte, the data showed no difference between samples. According to the results of variance analysis, the differences among the variations in number of coating were statistically insignificant (p>0.05), meaning that the two times of gold electroforming coating did not change the hardness of gold-silver-palladium alloy. Conclusion. The test of thickness of gold coating proved the coherency of the gold electroforming procedure, in other words, when the power, the exposed surface area, processing time and the amount of electrolytes were set same, the same thickness of gold would be coated on. The hardness test showed that the electroformed gold coating did not change the hardness of the gold-silver-palladium alloy when it is coated not more than $45{\mu}m$.

Evaluation of the Radiochromic Film Dosimetry for a Small Curved Interface (휘어진 경계에서의 좁은 영역에 대한 Radiochromic 필름 도시메트리 평가)

  • Kang, Sei-Kwon;Park, Soah;Hwang, Taejin;Cheong, Kwang-Ho;Han, Taejin;Kim, Haeyoung;Lee, Me-Yeon;Kim, Kyoung Ju;Bae, Hoonsik
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.234-238
    • /
    • 2012
  • A tumor on the eyelid is often treated using a high-energy electron beam, with a metallic eye shield inserted between the eyelid and the eyeball to preserve the patient's sight. Pretreatment quality assurance of the inner eyelid dose on the metallic shield requires a very small dosimetry tool. For enhanced accuracy, a flexible device fitting the curved interface between the eyelid and the shield is also required. The radiochromic film is the best candidate for this device. To measure the doses along the curved interface and small area, a 3-mm-wide strip of EBT2 film was inserted between the phantom eyelid and the shield. After irradiation with 6 MeV electron beams, the film was evaluated for the dose profile. An acrylic eye shield of the same size as the real eye shield was machined, and CT images free from metal artifacts were obtained. Monte Carlo simulation was performed on the CT images, taking into account eye shield material, such as tungsten, aluminum, and steel. The film-based interface dose distribution agreed with the MC calculation within 2.1%. In the small (millimeter scale) and curved region, radiochromic film dosimetry promises a satisfactory result with easy handling.