• Title/Summary/Keyword: Strip Mean Temperature

Search Result 6, Processing Time 0.02 seconds

FE-based Strip Mean Temperature Prediction On-Line Model in Hot Strip Finishing Mill by using Dimensional Analysis (차원해석을 통한 열간 사상압연중 온도해석모델 개발)

  • 이중형;곽우진;황상무
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2003.05a
    • /
    • pp.176-179
    • /
    • 2003
  • The mean temperature prediction of strip is very important in hot strip finishing mill because of affecting on product quality and shape. Also, temperature can be used by basic information in other on-line control models with affecting control accuracy in factory. So, FE based on-line temperature model was developed for predicting strip mean temperature accurately in various process conditions and factory environments. There are many variables in affecting strip mean temperature in on-line states of factory. But some problems are occurred in considering all variables for making temperature model because of the bad efficiency of regression or fitting analysis. In this report, we have adopted dimensional analysis for solving these problems. We have many variables with dimensions affecting strip temperature but we are able to make non-dimensional variables less than dimensional variables from the combination of dimensional variables caused by PI-Theorem in fluid mechanics. The developed models are divided by two parts. The one is interstand temperature prediction model. The other is roll gap temperature model.

  • PDF

Numerical Study of Natural Convection in a Rectangular Enclosure with Cooling Strip (냉각부(冷却部)를 갖는 사각형(四角形) 밀폐공간내(密閉空間內)의 자연대류(自然對流)에 관(關)한 수치해석(數値解析))

  • Lee, Cheong-Ouk;Seo, Jeong-Yun;Kim, Chong-Bo
    • Solar Energy
    • /
    • v.6 no.2
    • /
    • pp.54-61
    • /
    • 1986
  • The influence on natural convection was studied by solving the partial differential equations within a rectangular enclosure which have a cooling strip at the right side wall of the space, a isothermally heated bottom plate and adiabatic two other walls. Computation was carried out for the range of Grashof number from $5*10^3$ to $2.5*10^5$ with Plandtl number of 0.73. The results have been obtained in cases of four aspect ratios and various strip sizes. Temperature and Stream function distributions have been plotted using explicit finite difference method in two dimensional, laminar flow, and also mean Nusselt number and Local Nusselt number have been obtained.

  • PDF

Electromigration Behavior in the 63Sn-37Pb Solder Strip (63Sn-37Pb 솔더 스트립에서의 Electromigration 거동)

  • Lim Seung-Hyun;Choi Jae-Hoon;Oh Tae-Sung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.2 s.31
    • /
    • pp.53-58
    • /
    • 2004
  • To facilitate the observation of the electromigration of 63Sn-37Pb eutectic solder, strip-type samples were fabricated by solder evaporation. The electromigration test for the 63Sn-37Pb solder strip was conducted at temperatures of $80{\sim}150^{\circ}C$ and the current densities of $1{\times}10^4{\sim}1{\times}10^5\;A/cm^2$. With increasing temperature and the current density, mean-time-to-failure(MTTF) decreased due to the formation of hillock and void in the solder strip. The activation energy for the electromigration in the 63Sn-37Pb solder strip was analyzed as $0.16{\sim}0.5\;eV$ using Black's equation.

  • PDF

Comparision of Blood Gas Analyser, pH Meter and pH Strip Methods in the Measurement of Pleural Fluid pH (흉수의 pH 측정에서 혈액가스분석기계, pH meter, pH Strip 방법의 비교)

  • Jee, Hyun-Suk;Park, Yong-Bum;Choi, Jae-Chol;Ahn, Chang-Hyuk;Yoo, Ji-Hoon;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.5
    • /
    • pp.773-780
    • /
    • 2000
  • Background : pH measurement is an important test in assessing the etiology of pleurisy and in identifying complicated parapneumonic effusion. Although the blood gas analyzer is the gold standard method' for pleural pH measurement, pH meter & pH strip methods are also used for this purpose interchangably. However, the correlation among the pH data measured by the three different methods needs to be evaluated. In this study, we measured the pH of pleural fluid with the three different methods respectively and evaluated the correlation among the measured data. Methods : From August 1999 to March 2000, we measured the pleural fluid pH in 34 clinical samples with three methods-blood gas analyzer, pH meter, and pH strip. In the blood gas analyzer and pH meter methods, the temperature of pleural fluid was maintained around $0^{\circ}C$ in air-tight condition before analysis and measurement was performed within 30 minutes after collection. As for the pH strip method, the pleural fluid pH was checked in the ward immediately after tapping and in the clinical laboratory of our hospital. This part is unclear. Results : The causes of pleural effusion were tuberculosis pleurisy in 16 cases, malignant pleural effusion 5 cases, parapneumonic effusion 9 cases, empyema 3 cases, and congestive heart failure 1 case. The pH of pleural fluid (mean$\pm$SD) was 7.34$\pm$0.12 with blood gas analyser, 7.52$\pm$0.25 with pH meter, 7.37$\pm$0.16 with pH strip of immediate measurement and 6.93$\pm$0.201 with pH strip of delayed measurement. The pH measured by delayed pH strip measurement was lower than those of other methods (p<0.05). The correlation of the results between the blood gas analyzer and pH meter(p=0.002, r=0.518) and the blood gas analyzer and pH strip of immediate measurement(p<0.001, r=0.607). Conclusion : In the determination of pH of pleural fluid, pH strip method could be a simple and reliable method under immediate measurement conditions after pleural fluid tapping.

  • PDF

Characteristics of the Simulated ENSO in CGCM (대기-해양 접합 모델에서 모사한 ENSO의 특징)

  • Moon, Byung-Kwon
    • Journal of the Korean earth science society
    • /
    • v.28 no.3
    • /
    • pp.343-356
    • /
    • 2007
  • This paper explored the characteristics of the interannual sea surface temperature (SST) variability in the equatorial Pacific by analyzing the simulated data from a newly coupled general circulation model (CGCM). The CGCM simulates well the realistic ENSO variability as well as the mean climatologies including SST, seasonal cycle, precipitation, and subsurface structures. It is argued that the zonal gradient of SST in the equatorial Pacific is responsible for the over-energetic SST variability near the equatorial western boundary in the model. This variability could also be related to the strong westward propagation of SST anomalies which resulted from the enhanced the zonal advection feedback. The simple two-strip model supports this by sensitivity tests. Analysis of the relationship between zonal mean thermocline depth and NINO3 SST index suggested that the ENSO variability is controlled by the recharge-discharge oscillator of the model. The lead-lag regression result reveals that heat buildup process in the western equatorial Pacific associated with the increase of the barrier layer thickness (BLT) is a precedent condition for El $Ni\widetilde{n}o$ to develop.

A Study on Fabrication and Sintering Behavior of Al-Pb-X(Sn,Sn-Si) clad strips (급냉응고한 Al-Pb-X(Sn,Sn-Si)계 합금분말(合金粉末)의 압연판재(壓延板材)의 제조(製造)와 소결(燒結)특성)

  • Choi, Jong-Gu;Moon, Jong-Tai;Lee, Yong-Ho;Cho, Sung-Suk
    • Journal of Korea Foundry Society
    • /
    • v.12 no.3
    • /
    • pp.210-219
    • /
    • 1992
  • The measurement of the apparent and tap density for Al-Pb-X(Sn,Sn-Si) powders produced by centrifugal atomizer showed that the larger theoretically calculated densities the larger those densities. And tap densities were not over 50% of the theoretical densities. The nip angle of Al-5wt%Pb alloy powders produced with 38000 r.p.m. of disk rotation was $3^{\circ}$ degree larger than that of Al-8.5wt%Pb-3wt%Sn(-4wt%Si, 8wt%Si) with 50000 r.p.m. The effects of roll gap and rolling speed on thickness and density of the single strips by rolling were that rolling speed increasing the thickness and density of strip decreased and roll gap increasing, the thickness of strip increased but the density decresed. The compactibility of Al-Pb-X with Al by rerolling showed that the coarse powder-strips were better than fine powder-strips. From the SEM study with EDX analysis on the sintered strips, it was found that Pb and Sn were segregated with maximum size $5{\mu}m$, and Si existed surrounding the segregation zone. After sintering the clad strips at $500^{\circ}C$, the pores, which were spherical with $5{\mu}m$ of mean diameter, partly remained around the particles of alloy powders area, while completely disappeared at clad interface. The hardness of strips of alloy powders decreased linearly with increasing sintering temperature.

  • PDF