• Title/Summary/Keyword: Stress condition

Search Result 4,077, Processing Time 0.038 seconds

Numerical solution for multiple confocal elliptic dissimilar cylinders

  • Chen, Y.Z.
    • Smart Structures and Systems
    • /
    • v.19 no.2
    • /
    • pp.203-211
    • /
    • 2017
  • This paper provides a numerical solution for multiple confocal elliptic dissimilar cylinders. In the problem, the inner elliptic notch is under the traction free condition. The medium is composed of many confocal elliptic dissimilar cylinders. The transfer matrix method is used to study the continuity condition for the stress and displacement along the interfaces. Two cases, or the infinite matrix case and the finite matrix case, are studied in this paper. In the former case, the remote tension is applied in y- direction. In the latter case, the normal loading is applied along the exterior elliptic contour. For two cases, several numerical results are provided.

Structural Analysis of Continuous Casting Mold (연속주조 몰드의 구조해석)

  • 원종진;이종선;홍석주
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.10 no.4
    • /
    • pp.104-110
    • /
    • 2001
  • The objective of this study is structural analysis of continuous casting mold. A two-dimensional finite element model was developed to compute the temperature distribution, thermal stress and thermal strain behavior for continuous casting mold. Structural analysis was made using thermal analysis result, utilizing transient analysis of ANSYS. This structural analysis results, many variables such as casting speed, cooling condition film coefficient, convection and load condition are considered.

  • PDF

Optimal design of partially step-stress life testing for the series systems (부분적 단계충격 수명검사에 관한 직렬형 시스템의 최적 검사계획)

  • 박희창;이석훈
    • The Korean Journal of Applied Statistics
    • /
    • v.8 no.2
    • /
    • pp.121-132
    • /
    • 1995
  • In this paper we consider optimal designs of partially step-stress life testing which is deviced for k-component series systems with the considerably long life time. Test items are first run simultaneously at use condition for a specified time, and the surviving items are then run at accelerated condition until a predetermined censoring time. The optimal criterion for the change time to accelerated condition is to minimized either the generalized asymptotic variance of maximum likelihood estimators of the hazard rates at use condition and the acceleration factors or the asymptotic variance of the maximum likelihood estimators of the acceleration factors.

  • PDF

Optimal design of Partially Accelerated Life Testing for the Parallel Systems (병렬형 시스템의 부분적 가속수명검사를 위한 최적계획)

  • Park, Hee-Chang;Lee, Suk-Hoon
    • Journal of Korean Society for Quality Management
    • /
    • v.24 no.4
    • /
    • pp.14-28
    • /
    • 1996
  • We consider optimal designs of partially accelerated life testing which is deviced for parallel systems with the considerably long life time. In partially step-stress life testing, test items are first run simultaneously at use condition for a specified time, and the surviving items are then run at accelerated condition until a predetermined censoring time. In partially constant-stress life testing, test items are run at either use or accelerated condition only until a specified censoring time. The optimal criterion for each test is to minimize either the generalized asymptotic variance of maximum likelihood(ML) estimators of the hazard rates at use condition and the acceleration factors or the asymptotic variance of the ML estimators of the acceleration factors.

  • PDF

On-line Condition Monitoring of Thermal Accelerating Aged Transformer by Capacitive Sensor (전기용량 센서를 이용한 가속 열 열화 변압기의 온라인 상태진단)

  • Kim, Ju-Han;Han, Sang-Ok;Lee, Sei-Hyun;Kim, Han-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2005.07e
    • /
    • pp.82-84
    • /
    • 2005
  • In a transformer, thermal stress is the most influential parameter affecting the aging behavior of insulation system. The aging behavior of insulation system in transformer is determined mainly by the thermal conditions inside the transformer. The thermal stress on the insulation system may occur from operation in a high temperature caused by overloading or local overheating. Thus, this paper investigated the condition monitoring of insulation condition in thermally accelerated aged transformer oils by in-situ sensor. The condition of aged samples was investigated by measurements of relative permittivity i.e. capacitance change by capacitive sensor. Results from the experiments are presented in this paper.

  • PDF

Study on the Wear Characteristics of Gray Cast Iron under Dry Rolling Condition (건식조건하(乾式條件下)에서 회주철(灰鑄鐵)의 로링마모(磨耗)에 관(關)한 연구(硏究))

  • Choi, Chang-Ock;Kim, Dong-Yun
    • Journal of Korea Foundry Society
    • /
    • v.3 no.2
    • /
    • pp.92-99
    • /
    • 1983
  • This study has been carried out to investigate into the difference of rolling life and rolling wear characteristics for various gray cast iron under unlubricated dry rolling condition by amsler type wear test with 9.09% sliding.The results obtained from this study are summerized as follows: 1) It has been found that the amount of rolling wear id decreased when tensile strength and hardness are low, and then the rolling life up to generation of abnormal wear is conspicuously increased. 2) At the given condition the amount of rolling wear has been found to decrease as carbon equivalent of gray cast iron increases and resistance of crack propagation is an important factor on improvement of wear characteristics. 3) The amount of rolling wear is increased with increasing rolling revolution and wear of gray cast iron under dry rolling condition is characterized by three modes; initial wear, stationary wear and abnormal wear. 4) It has been found that the amount of rolling wear is increased with increasing maximum compressive stress and extremely increased when maximum compressive stress is over 59.1kg.f/mm.

  • PDF

Impact of appearance satisfaction and ego-resilience on employment stress among dental hygiene students (외모만족도와 자아탄력성이 치위생(학)과 재학생의 취업스트레스에 미치는 영향)

  • Kim, Sun-Ju;Kim, Han-Hong
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.1
    • /
    • pp.75-84
    • /
    • 2014
  • Objectives : The purpose of this study was to investigate the influence of the appearance satisfaction and ego-resilience of dental hygiene students on their employment stress. Methods : A self-reported questionnaire was filled out by 403 female dental hygiene students in five colleges in Chungbuk-do, Gyeongnam-do, and Daejeon. Results : 1. The college students got a mean of $2.78{\pm}0.42$, $3.27{\pm}0.41$ and $2.28{\pm}0.52$ in appearance satisfaction, ego-resilience and job-seeking stress, respectively. 2. Employment stress revealed higher score in poorer financial conditions(p<0.001) and less major satisfaction(p<0.001). 3. Employment stress had a negative correlation to a physical attraction and somatic condition which were the sub-factors of appearance satisfaction. Stress also had a negative correlation to personal relationship and emotional control which were the sub-factors of ego-resilience. 4. Household economy(p=0.023) was identified as a variable that affected job-seeking stress, physical attraction(p=0.048) and somatic condition(p=0.039). Personal relationship(p=0.040) and emotional control(p=0.034) were the influential variables and had 33.2% of explanation power for employment stress. Conclusions : Appearance satisfaction and ego-resilience were the factors affecting job-seeking stress. Therefore counseling and educational programs should be provided for dental hygiene students to look at their own appearance and bodies in a more positive way, to foster their ego-resilience, to relieve and properly cope with employment stress and ultimately to promote their mental health.

Estimation of the Axial Stress in High-Tension Bolt by Acoustoelastic Method (음탄성법을 이용한 고장력 볼트의 축응력 평가)

  • Chun, Hae-Hwa;Lee, Tae-Hoon;Jhang, Kyung-Young;Kim, Noh-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.5
    • /
    • pp.285-290
    • /
    • 2006
  • The evaluation of clamping condition has been regarded as the main issue in the safety-maintenance of the clamped high-tension bolts. For this, this paper proposes a method to estimate the axial stress by measuring the TOF (Time-Of-Flight) of ultrasonic wave, which is based on the acoustoelasticity or the dependency of sound speed on the stress. In this method, however, the variation of sound speed within the range of stress induced under the field condition is very small, and thus the accuracy of the TOF measurement is important. We adopted the phase detection method using tone-burst ultrasonic wave to measure the precise TOF. In order to verify the usefulness of the proposed method experiments are carried out and the results were compared with the stress measured by the strain gage. The results show good agreement with each other, and from these we can conclude that the proposed method is highly useful fnr the evaluation of clamping condition in the clamped high-tension bolts.

Requirement of Fur for the Full Induction of dps Expression in Salmonella enterica Serovar Typhimurium

  • Yoo, Ah-Young;Kim, Sam-Woong;Yu, Jong-Earn;Kim, Young-Hee;Cha, Jae-Ho;Oh, Jeong-Il;Eo, Seong-Kug;Lee, John-Hwa;Kang, Ho-Young
    • Journal of Microbiology and Biotechnology
    • /
    • v.17 no.9
    • /
    • pp.1452-1459
    • /
    • 2007
  • The Dps protein, which is overexpressed in harsh environments, is known to playa critical role in the protection of DNA against oxidative stresses. In this study, the roles of Fur in the expression of the dps gene in Salmonella and the protection mechanisms against oxidative stress in Salmonella cells preexposed to iron-stress were investigated. Two putative Fur boxes were predicted within the promoter region of the S. typhimurium dps gene. The profile of dps expression performed by the LacZ reporter assay revealed growth-phase dependency regardless of iron-status under the culture conditions. The fur mutant, $_X4659$, evidenced a reduced level of ${\beta}$-galactosidase as compared to the wild-type strain. The results observed after the measurement of the Dps protein in various Salmonella regulatory mutants were consistent with the results acquired in the reporter assay. This evidence suggested that Fur performs a function as a subsidiary regulator in the expression of dps. The survival ability of Salmonella strains after exposure to oxidative stress demonstrated that the Dps protein performs a pivotal function in the survival of stationary-phase S. typhimurium against oxidative stress. Salmonella cells grown in iron-restricted condition required Dps for full protection against oxidative stress. The CK24 (${\Delta}dps$) cells grown in iron-replete condition survived at a rate similar to that observed in the wild-type strain, thereby suggesting the induction of an unknown protection mechanism(s) other than Dps in this condition.

The Assessment for Coupling Integrity of Pressurizer Support Bolting (가압기 지지대 볼트 연결부의 건전성 평가에 관한 연구)

  • Cho, Nam-Jin;Kim, Woo-Chang;Kim, Hak-Joong
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.26-31
    • /
    • 2013
  • In nuclear power plant, anchor bolts for pressurizer supports are sufficiently used in terms of safety reason, but field inspections have reported that some bolts exceed the limit of their allowable hardness. Because the high level of hardness may lead to failures due to the stress corrosion or fracture toughness, a regular inspection is required for the bolts in nuclear power plant. Thus, this research measures the hardness of bolts currently used in pressurizer supports and then estimates maximum allowable stresses preventing failures by stress corrosion and fracture toughness. Using the ANSYS program, the stresses of the bolts in the regular condition and accidental condition have been calculated, and the possible maximum stress has been compared with the estimated allowable stresses. From the results, the stresses of bolts in the accidental condition satisfy the allowable safety stress from the stress corrosion failure. However, in the future, it shall be needed to consider the reflection of the structure assembling method on the assembling procedure to ensure the pressurizer integrity during maintenance period time.