• 제목/요약/키워드: Stress Acceleration

검색결과 377건 처리시간 0.021초

주기 가속도 위상변화에 따른 협착 및 분지 혈관의 혈류 특성에 대한 수치해석적 연구 (NUMERICAL STUDY ON THE BLOOD FLOW CHARACTERISTICS OF STENOSED AND BIFURCATED BLOOD VESSELS WITH A PHASE ANGLE CHANGE OF A PERIODIC ACCELERATION)

  • 노경철;조성욱;이성혁;유홍선
    • 한국전산유체공학회지
    • /
    • 제13권3호
    • /
    • pp.44-50
    • /
    • 2008
  • The present study is carried out in order to investigate the effect of the periodic acceleration in the stenosed and bifurcated blood vessels. The blood flow and wall shear stress are changed under body movement or acceleration variation. Numerical studies are performed for various periodic acceleration phase angles, bifurcation angles and section area ratios of inlet and outlet. It is found that blood flow and wall shear stress are changed about ${\pm}20%$ and ${\pm}24%$ as acceleration phase angle variation with the same periodic frequency. also wall shear stress and blood flow rate are decreased as bifurcation angle increased.

냉장고용 압축기의 가속수명시험을 위한 가혹조건 탐색 - 저온 가혹조건에서의 가속계수와 단축 시험기간 - (Investigation into the Worst Stress Condition for an Accelerated Life Test of a Compressor in Refrigerators - Acceleration Factor and the Reducible Test Time under Low Temperature -)

  • 정영미;주우진;정석권
    • 동력기계공학회지
    • /
    • 제16권2호
    • /
    • pp.43-48
    • /
    • 2012
  • Generally accelerated life test is well known as one method to reduce reliability qualification test period. This test is conducted under the higher stress condition than normal condition. So it can save the test time by calculating the acceleration factor from the relationship between the worst stress condition and normal condition. This paper investigates the worst stress condition for the accelerated life test to increase the acceleration factor. Especially, we focused on the method to obtain effective acceleration factors under the worst stress condition. Moreover, we considered how to decide the worst stress condition by looking for the operating limit of this system. The acceleration factor can be estimated from the ratio of the kinematic viscosity in the normal condition and the worst stress condition, the lowest temperature, by using Arrhenius relationship. Through some experiments for a refrigerator's compressor, we were able to confirm how to increase acceleration factors and how to reduce the reliability qualification test period with minimum samples.

Effect of body acceleration on pulsatile flow of Casson fluid through a mild stenosed artery

  • Nagarani, P.;Sarojamma, G.
    • Korea-Australia Rheology Journal
    • /
    • 제20권4호
    • /
    • pp.189-196
    • /
    • 2008
  • The pulsatile flow of blood through a stenosed artery under the influence of external periodic body acceleration is studied. The effect of non-Newtonian nature of blood in small blood vessels has been taken into account by modeling blood as a Casson fluid. The non-linear coupled equations governing the flow are solved using perturbation analysis assuming that the Womersley frequency parameter is small which is valid for physiological situations in small blood vessels. The effect of pulsatility, stenosis, body acceleration, yield stress of the fluid and pressure gradient on the yield plane locations, velocity distribution, flow rate, shear stress and frictional resistance are investigated. It is noticed that the effect of yield stress and stenosis is to reduce flow rate and increase flow resistance. The impact of body acceleration is to enhance the flow rate and reduces resistance to flow.

지반변동성을 고려한 액상화 진동전단응력비의 확률론적 해석 (Probabilistic Analysis of Liquefaction Cyclic Stress Ratio Considering Soil Variability)

  • 허준
    • 한국농공학회논문집
    • /
    • 제60권2호
    • /
    • pp.95-101
    • /
    • 2018
  • The objective of this study is to evaluate the liquefaction cyclic shear stress ratio considering the soil uncertainty. In this study, the probabilistic ground response analysis and the cyclic shear stress ratio analysis for the liquefaction potential evaluation are performed considering the soil variability. The statistical properties of input ground parameters were analyzed to investigate the parameters affecting the seismic response analysis. The Probabilistic analysis was carried out by Monte Carlo Simulation method. The ground response analysis was performed considering the soil variability and the probability distribution characteristics of the ground acceleration. The probability distribution of the peak ground acceleration by seismic characteristics was presented. The differences of liquefaction shear stress ratio results according to soil variability were compared and analyzed. The maximum acceleration of the ground by the deterministic method was analyzed to be overestimation of the ground amplification phenomenon. Also, the shear stress ratio was overestimated.

F1 서킷 극한주행시험을 통한 알루미늄 알로이 휠의 동응력/변형률 계측 및 분석 (Dynamic Stress/Strain Measurement and Analysis of the Aluminum Alloy Road Wheel through F1 Circuit Ultimate Driving Test)

  • 이창수;박철순;박형배;정성필;정원선
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.612-617
    • /
    • 2014
  • It is generally known that the automotive road wheel involves the non-proportional multiaxial loading condition, therefore the measuring dynamic stress and strain in driving state is very important to predict an endurance characteristic of the automotive road wheel. In this study, the ultimate driving test using F1 circuit with respect to 2 kinds of velocity conditions have been carried out in order to measure dynamic stress, strain of the wheel and acceleration of a vehicle. Based on the measured results, the characteristics of dynamic stress generation have been analyzed, and factors which have effect on the dynamic stress generation have been studied.

  • PDF

Numerical study of the effects of periodic body acceleration (PGZ) and bifurcation angle in the stenosed artery bifurcation

  • Ro, Kyoung-Chul;Ryou, Hong-Sun
    • Korea-Australia Rheology Journal
    • /
    • 제21권3호
    • /
    • pp.175-183
    • /
    • 2009
  • This article describes the numerical investigation of blood flow in the stenosed artery bifurcation with acceleration of the human body. Using the commercial software FLUENT, three-dimensional analyses were performed for six simulation cases with different body accelerations and bifurcation angles. The blood flow was considered to be pulsation flow, and the blood was considered to be a non-Newtonian fluid based on the Carreau viscosity model. In order to consider periodic body acceleration, a modified, time-dependent, gravitational-force term was used in the momentum equation. As a result, flow variables, such as flow rate and wall shear stress, increase with body acceleration and decrease with bifurcation angle. High values of body acceleration generate back flow during the diastolic period, which increases flow fluctuation and the oscillatory shear index at the stenosis.

유한요소 모델을 이용한 인간 뇌의 미만성 부상에 대한 해석 (Analysis of the Diffuse Axonal Injury of the Human Brain using Finite Element Model)

  • 김영은;남대훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권6호
    • /
    • pp.603-609
    • /
    • 1998
  • 가속도 변화에 따른 뇌의 미만성 부상을 해석하기 위하여 성인 및 2세, 6세아의 머리 부분에 대한 유한 요소 모델을 개발하였다. 외력은 최대값이 200g인 삼각형 형태의 가속도를 가하였으며, 가속도의 방향, 지속시간에 따른 변화를 해석하였다. 가속도 변화에 따라 발생되는 뇌내의 전단력 분포는 뇌간, 뇌교 및 중뇌등 신경조직이 밀집된 곳에서 크게 발생되어 이곳에서 미만형 부상이 발생할 확률이 높음을 알 수 있었으며, 특히 6세아 모델의 경우 뇌간에서의 최대 전단력이 굴전 형태의 회전가속도 받았을 때 가장 크게 나타나는 결과를 보여 개발된 모델이 임상결과와 일치함을 보여주고 있었다. 가속도 지속 시간이 길어짐에 따라 뇌내에 발생되는 압력 및 최대 전단력의 크기가 증대되고 있었으며, 유아모델의 경우 성인모델에 비하여 가속도 방향과 관계없이 낮은 압력이 발생하였지만 발생압력이 감소하지 않고 지속되는 현상을 보이고 있었다. 그리고 각 가속도에 의한 미만성 부상을 예방하기 위한 안전지수로는 현재 탑승자의 안전 설계에 활용되고 있는 HIC보다는 최대 전단응력이 더 적절한 부상 예측인자임을 알 수 있었다.

  • PDF

Optimal Plan of Partially Accelerated Life Tests under Type I Censoring

  • Moon, Gyoung-Ae
    • Journal of the Korean Data and Information Science Society
    • /
    • 제5권2호
    • /
    • pp.87-94
    • /
    • 1994
  • In this paper, we consider optimum plan to determine stress change times under the three-step stress PALTs, assuming that each test units follows an exponential distribution. The tampered random variable(TRV) model for the three-step stress PALTs setup are introduced, and maximum likelihood estimators(MLEs) of the failure rate and the acceleration factors are obtained. The change times to minimize the generalized asymptotic variance(GAVR) of MLEs of the failure rate and the acceleration factors are proposed for the three-step stress PALTs.

  • PDF

Optimal Designs for Constant Stress Partially Accelerated Life Tests under Type I Censoring

  • Moon, Gyoung-Ae
    • Journal of the Korean Data and Information Science Society
    • /
    • 제6권2호
    • /
    • pp.77-83
    • /
    • 1995
  • The inferences on a series system under the usual condition using data from constant stress partially accelerated life tests and type I censoring is studied. Two optimal designs to determine the sample proportion allocated each stress level model are also presented, which minimize the sum of the generalized asymptotic variances of maximum likelihood estimators of the failure rate and the acceleration factors and the sum of the asymptotic variances of maximum likelihood estimators of the acceleration factors for each component. Each component of a system is assumed to follow an exponenial distribution.

  • PDF

Analysis the Reliability of Multilayer Ceramic Capacitor with inner Ni Electrode under highly Accelerated Life Test Conditions

  • Yoon, Jung-Rag;Lee, Kyung-Min;Lee, Serk-Won
    • Transactions on Electrical and Electronic Materials
    • /
    • 제10권1호
    • /
    • pp.5-8
    • /
    • 2009
  • The reliability of multilayer ceramic capacitor with active thin dielectric layer was investigated by highly accelerated life test at various stress condition. The distribution of multilayer ceramic capacitor failure times is plotted as a function of time from Weibull distribution function. According to the test result, voltage acceleration factor is obtained from 2.24 to 2.96. The acceleration by temperature is much higher than other values of active thick dielectric layer. It is clear that median time to failure is affected by the stress voltage for high volumetric efficiency ceramic capacitors with active thin dielectric layer. The degradation under stress of voltage involves electromigration and accumulation of oxygen vacancy at Ni electrode interface of cathode.