Effects of Lumbar Stabilization Exercise on Lower Extremity Strength

  • Chung, Eun-Jung;Jang, Sang-Hun
    • Journal of Korean Physical Therapy Science
    • /
    • v.24 no.3
    • /
    • pp.48-55
    • /
    • 2017
  • Purpose: this study was conducted on female university students in supine position and preformed the 2 bridge positions exercises, which are the bridge position exercise and the bridge exercise preformed with form rollers attached between their knees, in order to research the effects lumbar stabilization exercise has on lower extremity muscular strength. Method: In order for the participants to fully understand the topic and procedures of the experiment, they were given a 20 minutes of briefing and practice before the experiment. Result: Bridge exercise group and foam roller group were improved the knee flexion and extension strength. Conclusion: This research studied the difference of each lumbar stabilization positions and the effects they have on the fortification of the leg's flexion extension muscular strength, and by comparing which different exercise methods increase muscular strength the most works to plan a more optimal exercise method for lumbar stabilization.

Size Effect on Axial Compressive Strength of Notched Concrete Specimens

  • Yi, Seong-Tae;Kim, Jin-Keun
    • KCI Concrete Journal
    • /
    • v.14 no.1
    • /
    • pp.43-50
    • /
    • 2002
  • In this study, size effect tests were conducted on axial compressive strength of concrete members. An experiment of Mode I failure, which is one of two representative compressive failure modes, was carried out by using dimensionally proportional cylindrical specimens (CS). An adequate notch length was taken from the experimental results obtained from the compressive strength experiment of various initial notch lengths. Utilizing the notch length, specimen sizes were then varied. In addition, new parameters for the modified size effect law (MSEL) were suggested using Levenberg-Marquardt's least square method (LSM). The test results show that size effect was apparent for axial compressive strength of cracked specimens. Namely, the effect of initial notch length on axial compressive strength size effect was apparent.

  • PDF

The Effects of Number and Location of Finger Joints on the Bending Strength of Glue Laminated Wood for Green Wood Building (핑거접합부의 수량 및 배치가 생태목조건축용 집성재의 휨강도에 미치는 영향)

  • So, Won-Tek
    • Journal of the Korea Furniture Society
    • /
    • v.18 no.1
    • /
    • pp.20-30
    • /
    • 2007
  • This experiment was carried out to investigate the effects of number and location of finger joints on the bending strength of glue-laminated lumbers. Urea resin adhesives were used in this experiment and the resin content was 70% for cold pressing. The lamina were edge-jointed and end-jointed. The specimen were composed of one or three layers. The obtained results are summarized as follows; The effects of finger joints on the decrease of bending strength of glue laminated woods were different according to the number and location of finger joints. The decrease of MOR was highest on the middle position of laminated woods. The effects of several arrangements of finger joints on the bending strength of glue laminated woods showed on Figure 7 and 8. The variance of thickness-laminating on the bending strength of glue laminated woods were larger than those of width-laminating.

  • PDF

Experimental study on reinforced high-strength concrete short columns confined with AFRP sheets

  • Wu, Han-Liang;Wang, Yuan-Feng
    • Steel and Composite Structures
    • /
    • v.10 no.6
    • /
    • pp.501-516
    • /
    • 2010
  • This paper is aiming to study the performances of reinforced high-strength concrete (HSC) short columns confined with aramid fibre-reinforced polymer (AFRP) sheets. An experimental program, which involved 45 confined columns and nine unconfined columns, was carried out in this study. All the columns were circular in cross section and tested under axial compressive load. The considered parameters included the concrete strength, amount of AFRP layers, and ratio of hoop reinforcements. Based on the experimental results, a prediction model for the axial stress-strain curves of the confined columns was proposed. It was observed from the experiment that there was a great increment in the compressive strength of the columns when the amount of AFRP layers increases, similar as the ultimate strain. However, these increments were reduced as the concrete strength increasing. Comparisons with other existing prediction models present that the proposed model can provide more accurate predictions.

An experimental study on the fragility factor of high strength concrete (고강도 콘크리트의 취도계수에 관한 실험적 연구)

  • Kim, Hui-Doo;Yang, Seong-Hwan
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.148-149
    • /
    • 2014
  • In modern society, population overcrowding and concentration of facilities are happened because of the concentration on to city. So this phenomenon demands improvement of material's performance, technical development of structure analysis and design and improvement of constructing ability .High strength concrete has some merits. High strengthening makes the cross section reduced, and that cause decrease of structure weight. And using high durable and superplasticizer promote liquidity, thus high quality concrete can be produced. Because of these advantages, this study is for showing validity of using it by compression/tensile strength experiment. As this experiment's result, when concrete become stronger, interface intensity coefficient between cement and aggregate is different and they don't adhere to each other. So there is brittle failure. Fragility factor also steadily increase with strong concrete, it tells high strength concrete has problem. Therefore the sources used in high strength concrete like cement and aggregate must have great quality. So the source's performance must be supervised well because their quality decides performance criteria.

  • PDF

A Fundamental Study on the Strength Development in Cement Mortar under Initial Curing Temperature (초기양생온도에 따른 시멘트 모르터의 강도발현에 관한 기초적 연구)

  • 백민수;이영도;임남기;김성식;이종균;최문식;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.157-165
    • /
    • 1997
  • In this experiment, there is a purpose to analysis the relationship of feature of compressive strength after fixing of remarkable element under the condition of initial curing temperature. According to this experiment, we get to the fallow result. In case of highest curing temperature, 3-day-strength become high but last revelation of strength become low among the condition of initial curing temperature, the highest curing temperature have an effect on revelation of strength by the application of cumulative temperature, we can get the shape of revelation of strength.

  • PDF

The Properties of High Flowing and Strength Concrete Utilizing Crushed Sand for CFT Structure (부순모래를 사용한 CFT 구조용 고유동.고강도콘크리트의 물성 변화)

  • Ahn Nam-Shik;Rhim Hong-Chul;Lim Hye-Sun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.89-92
    • /
    • 2006
  • To investigate the properties of high flowing and high strength concrete with crushed sand and fly ash for CFT structure, many batches were performed by a trial-error method. In the experiment W/B was set up three levels as 0.25, 0.30 and 0.35. Also the variables of the experiment were a substitution ratio of fly ash, a blend ratio of crushed sand and the ages of specimens(3, 7, 28 days). The results of this study are summarized as the follows; 1) The effect a substitution ratio of fly ash on the compressive strength was not consistent with age. For twenty-eight day compressive strength, the best result was come out when cement was substituted by 10% of fly ash. 2) The decrease of the water binder ratio, the increase of compressive strength and elastic modulus. Also the relationship is very similar to the case of a normal concrete

  • PDF

Variation of Welded-Joint Tensile Strength of GMA Welded Accelerated-Cooled Steel (가속냉각강 GMAW 용접이음부의 강도 변화)

  • 방국숙;정성욱
    • Journal of Welding and Joining
    • /
    • v.18 no.6
    • /
    • pp.83-88
    • /
    • 2000
  • Variation of welded-joint hardness and tensile strength of a accelerated-cooled fine-grained ferritic-pearlitic steel with heat input was investigated. In a weld heat-affected zone, a softened zone was formed and it had lower hardness than that of a base metal. While the width of a softened zone increased continuously with an increase of heat input up to 100kJ/cm. the minimum hardness in a softned zone was almost constant after a continuos decrease up to 60KJ/cm. Because of a softened zone, the welded-joint was fractured in the HAZ and its maximum reduction of tensile strength was about 20%. Measured welded-joint tensile strength and calculated minimum tensile strength in a welded-joint was almost same, which means that the plastic restraint of a softened zone did not occur in this experiment. It is believed that as a softened zone width-to-specimen thickness ratio is as high as 2~6 in this experiment, the plastic restraint effect does not occur. Theoretical analysis shows that the plastic restraint effect occurs only when the ratio is below 0.5.

  • PDF

A Study On the Mix Design and Quality Control System of High Strength Concrete for the Construct ion of High Rise Complex Structure (초고층 주상복합구조물에 적용한 고강도 콘크리트의 배합설계 및 품질관리 시스템에 관한 연구)

  • Kim, Sun-Gu;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon;Kim, Dong-Seok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.40-45
    • /
    • 2001
  • The purposes of this study were mix design and quality control of high strength concrete for the construction of high rise complex structure. Desired performances of this high strength concrete were slump flow 50$\pm$10cm, air content 4.5$\pm$1.5% and design strength 400kgf/$cm^2$. Experimental flow was that optimal mix design was selected in the indoor experiment and after that, producing test was done in the batcher plant. Excel lent results of experiment was obtained from binder content 475kg/$m^2$ with replacement ratio 10% of fly ash. The results of field application of high strength concrete was sufficiently satisfied both flowability and compressive strength.

  • PDF

An Experimental Study for Basic Properity of Ultra High-strength Concrete (초고강도 콘크리트의 기초물성에 관한 실험적 연구)

  • Kim Ji-Man;Gong Min-Ho;Yang Dong-Il;Jung Sang-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2006.05a
    • /
    • pp.39-42
    • /
    • 2006
  • Recently, more highly effective construction materials are needed for the reasonable and economical structure system is required as the construction structures become more multi storied, large-sized and diversified. That is to say, the highly qualified concrete, the molt universal construction material is positively promoted as a part of plan to establish the effective space according to the dead load of structures and diminish of segment profile and to build up the economic structures. In particular, it is tendency of that the study for high strength concrete increases and construction example of reinforced concrete (RC) using the high strength concrete partially increases. However, the high strength concrete has the problems such high brittleness and low ductility. Specially, for the high strength concrete, it has different strength from normal concrete as the internal temperature goes up steadily due to high heat of hydration by the quantities of highly level of cement, so the concrete which is mixed with various scible materials is used. This study conducted a basic experiment to conclude an adequate selection of materials and to calculate an optimal mixing proportion of those materials to produce High-strength concrete. And also we conducted an experiment to find out basic properties of this concrete such as slump-flow, strength.

  • PDF