• 제목/요약/키워드: Street Light Fixture

검색결과 7건 처리시간 0.022초

주거지역에서 가로조명에 의한 침입광발생 분석 (A Field Investigation on Light Trespass of Residential Buildings by Street Lighting)

  • 하나;김정태
    • KIEAE Journal
    • /
    • 제10권2호
    • /
    • pp.71-78
    • /
    • 2010
  • Spill light by street lighting is a kind of light pollution creating cozy night atmosphere, interfere visual private and cause insomnia at night. This study was to survey light trespass of the windows in residential buildings. According to outdoor lighting control guidance in Seoul, three different areas were selected to investigate the trespass light to windows. The results were as follows: 37% of the buildings of 386 buildings were influenced by street lighting, and 47% of windows were occurred light trespass. Therefore, the street lighting affected light trespass at night in survey area. The main reasons of light trespass were luminaire type, luminaire pole height, and street width. For protecting the light trespass to windows, it is necessary to non-cutoff fixture to full cutoff fixture by the street width.

두 가지 배광을 갖는 LED 횡단보도 조명장치에 관한 연구 (A Study on a Novel LED Lighting Fixture for Crosswalk Having Two Different Light Distributions)

  • 김형진;이동규;곽준섭
    • 한국전기전자재료학회논문지
    • /
    • 제27권9호
    • /
    • pp.606-611
    • /
    • 2014
  • Recently, LED lighting fixtures for crosswalk become popular in order to recognize the pedestrians at crosswalk, which can enhance the safety of the pedestrian at crosswalk. However, there are several problems related to the LED lighting fixtures for crosswalk, such as a lot of energy consumption due to a constant illumination during night and glaring of pedestrians at the opposite side of crosswalk. In this study, in order to overcome these problems, we have investigated a novel LED lighting fixture for crosswalk, which has two modules with different angles ($60^{\circ}$, $120^{\circ}$). Illuminance of min and max at four-line city street crosswalk shown 50 Lux, 125 Lux, respectively. Illuminance of min and max at eight-line city street crosswalk shown 150 Lux, 200 Lux, respectively. Simulation investigation was optimized design using optical program. Prototype was verified measurement by goniometer system.

A Mobile Object Tracking Scheme by Wired/wireless Integrated Street Lights with RFID

  • Cha, Mang Kyu;Kim, Jung Ok;Lee, Won Hee;Yu, Ki Yun
    • 대한공간정보학회지
    • /
    • 제24권2호
    • /
    • pp.25-35
    • /
    • 2016
  • Since a sophisticated location determination technology (LDT) is necessary for accurate positioning in urban area environments, numerous studies related to the LDT using the RFID (Radio Frequency IDentification) technology have been implemented for real-time positioning and data transferring. However, there are still lots of unsolved questions especially regarding what to use as base stations and what are corresponding results under the intrinsic complexity of alignment and configuration of components used for the RFID positioning. This study proposes the street light fixtures as base stations where the RFID receivers will be embedded for the mobile tracking scheme. As street light fixtures are usually installed at a certain distance interval, they can be used as base stations for the RFID receiver installation. Using the principle of the single row triangle network, the RFID receiver organization is determined based on the experiments such as recognition distance measurement and tag position accuracy estimation at inside and outside of the single row triangle network. The results verify that the mobile tracking scheme which uses RFID-embedded street light fixtures, suggested and configured in this study, is effective for the real-time outdoor positioning.

탄소배출권용 AIoT 고효율 가로등 성능분석 연구 (A Study on the Performance Analysis of AIoT High-Efficiency Streetlamp for Carbon Emissions)

  • 박승호;신성욱;유경선
    • 미래기술융합논문지
    • /
    • 제2권4호
    • /
    • pp.13-19
    • /
    • 2023
  • 파리기후변화협약(UNFCCC, 2015) 체결에 따라 선진국뿐만 아니라 개발도상국을 포함하는 포괄적 참여를 통해 전 세계가 온실가스 감축 활동을 확대하고 있다. 세계 주요국은 탄소배출권 시장을 통한 탄소배출 총량규제의 효과에 많은 기대를 걸고 있다. 그러나 탄소배출권을 얻기 위해서는 정량적인 탄소저감량 데이터를 바탕으로 제3자 검증이 필요하다. 이에 본 논문에서는 탄소배출권용 AIoT 고효율 가로등을 개발하여 등기구의 광효율을 측정하는 성능분석 연구를 진행했다. 탄소배출권을 얻기 위해 고효율 LED PKG를 사용하며 고전압용 PFC를 자체 개발하고 통신이 가능한 고효율의 등기구를 개발했다. 통신을 위해 등기구와 Gateway간 2.4GHz LoRa 방식을 채택했다. 한국 도로공사 표준 가로등 Type A, B, C 시뮬레이션을 통하여 렌즈 설계를 진행했다. 가로등의 성능은 공인 성적기관의 광효율 측정을 통하여 기존 타제품 대비 고효율의 성능을 검증하였으며, 이를 통한 전기에너지 절감으로 탄소배출권을 획득할 것으로 기대된다.

초정압 방전램프(UCD)를 적용한 안전 조명 장치에 관한 연구 (An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp)

  • 정풍기;김영철
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2010년도 추계학술대회
    • /
    • pp.63-80
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

  • PDF

초정압 방전램프(UCD)를 적용한 안전조명 장치에 관한 연구 (An Experimental Study on the a Light Device which Adopt Safety Ultra Constant Dischange Lamp)

  • 정풍기;김영철
    • 대한안전경영과학회지
    • /
    • 제12권4호
    • /
    • pp.41-51
    • /
    • 2010
  • This paper describes the development of various lighting equipment adapting Ultra Constant Discharge Lamp that has newly been on commercial supply in the market. Meeting the required conditions of lighting equipment, various types of UCD Lamp equipment with excellent performances could be successfully developed. In order to provide a guideline for the economical lighting product selection, the analyzed data comparison between Hi-pressure Sodium Lamp which has been the most popular lamp for street lighting and UCD Lamp is provided. The conclusions of the study are made as follows; (1) The performance measurement result of UCD Lamp shows excellent Luminous Efficacy as 108Lm/W, daylight-like Color Rendering Index as 90Ra, and the best operating temperature range as $-50^{\circ}C{\sim}+85^{\circ}C$. Comparing to the Hi-pressure Sodium Lamp, UCD could be evaluated as much superior products. (2) In an assembled status with the lighting fixture (Type STB형-60W), UCD Lamp was tested OK for one hour duration at the temperature range form $-50^{\circ}C$ to $+85^{\circ}C$ and the humidity of 98%. The operation at the extremely low temperature can be an excellent feature to enable the export to the cold temperature regions such as Northern Europe and Russia and the specific applications for defense systems and special industry. (3) As UCD Lamp is a genuine Korea made product following Energy-saving and Eco-friendly policy, it should be appreciated as one of the best $CO^2$ reduction Green product.

CFD 해석을 이용한 한국도로공사 표준 25 [W] LED 모듈의 방열 특성 분석 (Analysis of Heat Dissipation Characteristics for Standard 25 [W] LED Module of Korea Expressway Corporation: Using CFD Analysis)

  • 이세일;허인성;이아람;정민주;유영문
    • 한국전기전자재료학회논문지
    • /
    • 제27권8호
    • /
    • pp.541-546
    • /
    • 2014
  • Korea Expressway Corporation established standard of LED lighting fixture in Dec. 2013. To raise compatibility, the standard requires a fixed form and it is applied to street lights and tunnel lights, etc. Because streetlight has different circumstance condition from tunnel light that is down light and exposed to constant wind velocity over height of 8 meters, in case of LED module which has the same shape, characteristic of radiant heat can be different. In this paper, we designed 25 [W] LED Module that is designated by standard of Korea Expressway Corporation and analyzed characteristics of radiant heat about natural convection and forced convection. It is dropped 10.12[$^{\circ}C$] that max temperature is decreased by increasing 20 mm of bended height of heatsink at the condition of natural convection. Radiant heat characteristic of bended height 35 mm became 78.08[$^{\circ}C$] at the condition of natural convection, 55.30[$^{\circ}C$] at the condition of forced convection so that 22.78[$^{\circ}C$] is decreased that is 29.1[%] decrease. Bended height 55mm became 67.96[$^{\circ}C$] at the condition of natural convection, 48.04[$^{\circ}C$] at the condition of forced convection so that 19.92[$^{\circ}C$] is decreased that is 29.3% decrease.