• Title/Summary/Keyword: Stray currents

Search Result 34, Processing Time 0.024 seconds

Considerations on the Safety of Electric Caps Based on Measured Electrical Resistivity of Rock Samples (암석의 전기비저항 측정을 통한 전기뇌관의 사용 안전성 검토)

  • Choi, Byung-Hee;Ryu, Chang-Ha;Shin, Seung-Wook;Kim, Soo-Lo
    • Explosives and Blasting
    • /
    • v.34 no.4
    • /
    • pp.19-27
    • /
    • 2016
  • Much care should be taken when electric caps are used in blast site than when non-electric initiation systems are used. This is because electric caps can cause premature firing or misfires if stray currents of high magnitude flow into the blasting circuit. If the rock has higher electrical conductivity or lower electrical resistivity, such risks will be increased because the rock will provide more passages for the stray currents to flow into the blasting circuit. In this study, several rock samples obtained at a blast site were tested for electrical resistivity to decide whether electric caps could be used or not in the site. The measured electrical resistivity was $39{\sim}47{\Omega}{\cdot}m$ for the rock samples that had a higher content of metal sulfides. Contrary, the resistivity was $15000{\sim}21000{\Omega}{\cdot}m$ for ordinary rocks. Especially, in the case of the rock of electric resistivity of $39{\Omega}{\cdot}m$, only 2-V electric potential enables a stray current to flow through the rock of 1-m length, which can cause the premature firing of a detonator whose initiation current is 0.4 A. This result shows that electric initiation system should not be used in the site because rocks containing much amount of metal sulfides are widely distributed there.

A Study on Modeling and Damping of High-Frequency Leakage Currents in PWM Inverter Feeding an Induction Motor (PWM 인버어터로 구동되는 유도 전동기의 고주파 누설전류 모델링 및 억제에 관한 연구)

  • 이재호;전진휘;홍정표;강필순;박성준;김철우
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.18-22
    • /
    • 1998
  • A PWM inverter with an induction motor often has a problem with a high frequency leakage current that flows through stray capacitor between stator windings and a motor frame to ground. This paper presents an equivalent circuit for high frequency leakage currents in PWM inverter feeding an induction motor, which forms an LCR series resonant circuit. A conventional common mode ckoke or reactor in series between the ac terminals of a PWM inverter and those of an ac motor is not effective to reduce the rms and average values of the leakage current, but effective to reduce the peak value. Furthermore, this paper proposes a leakage current damper which is different in damping principle from the conventional common mode choke. It is shown theoretically and experimentally that the leakage current damper is able to reduce the rms value of the leakage current to 25%, where the core used in the leakage current damper is smaller than that of the conventional common-mode choke

  • PDF

Measurements of the Ground Resistance using the Test Current Transition Method in Powered Grounding Systems (측정전류전이법을 이용한 운전중인 접지시스템의 접지저항 측정)

  • Lee, Bok-Hui;Eom, Ju-Hong;Kim, Seong-Won
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.8
    • /
    • pp.347-353
    • /
    • 2002
  • This paper presents an accurate method for measuring the ground resistance in powered grounding system. Most of substations and electric power equipments are interconnected to an extensive grounding network of overhead ground wires, neutral conductors of transmission lines, cable shields, and etc. The parasitic effects due to circulating ground currents and ground potential rise make a significant error in measuring the ground resistance. The test current transition method was proposed to reduce the effects of stray ground currents, ground potential rise and harmonic components in measurements of the ground resistance for powered grounding systems. The instrumental error of the test current transition method is decreased as the ratio of the test current signal to noise(S/N) increases. It was found from the test results that the proposed measuring method of the ground resistance is more accurate than the conventional fall-of-potential method or low-pass filter method, and the measuring error was less than 3[%]when S/N is 10.

Common Model EMI Prediction in Motor Drive System for Electric Vehicle Application

  • Yang, Yong-Ming;Peng, He-Meng;Wang, Quan-Di
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.1
    • /
    • pp.205-215
    • /
    • 2015
  • Common mode (CM) conducted interference are predicted and compared with experiments in a motor drive system of Electric vehicles in this study. The prediction model considers each part as an equivalent circuit model which is represented by lumped parameters and proposes the parameter extraction method. For the modeling of the inverter, a concentrated and equivalent method is used to process synthetically the CM interference source and the stray capacitance. For the parameter extraction in the power line model, a computation method that combines analytical method and finite element method is used. The modeling of the motor is based on measured date of the impedance and vector fitting technique. It is shown that the parasitic currents and interference voltage in the system can be simulated in the different parts of the prediction model in the conducted frequency range (150 kHz-30 MHz). Experiments have successfully confirmed that the approach is effective.

A Novel Flexible PCB Conductive Structure for Electrodynamic Bearings and Measurement in its Induced Voltage

  • Ding, Guoping;Sandtner, Jan;Bleuler, Hannes
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.5
    • /
    • pp.2001-2008
    • /
    • 2015
  • This paper proposes the concept of FlexPCB(flexible Printed Circuit Board) conductive structure for electrodynamic bearings. It has three main advantages: easy “printing” of considerably thin conductive wires, resulting in potential reduction in stray eddy currents; realization of specific conductive configurations with high precision to optimize the eddy current flowing; simplicity in being wound to cylinders or hollow cylinders of different diameters. To verify this new concept, the FlexPCB conductive structure was manufactured, an axial electrodynamic bearing test rig was built and the conductive structure's induced voltage was measured along the axial displacements from 0mm to 56mm at three rotating speeds. The finite element method was used to calcuatlate the flux density of electrodynamic bearing and induced voltage of the FlexPCB conductive structure. The experimental results are compared with the results from the FEM calculation. It is concluded that the measured and calculated induced voltages have consistency in the middle part of the bearing.

Switching behavior in Peramlloy/Niobium/Permalloy trilayer

  • Hwang, Tae-Jong;Kim, Dong Ho
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.4
    • /
    • pp.17-20
    • /
    • 2014
  • We have investigated the effect of temperature and bias current on the stability of the inverse spin-switch effect in Permalloy(Py)/Nb/Permalloy pseudo spin-valves. The inverse spin-switch operates between two orientations of the ferromagnetic moments of Py layers; parallel (ON) and antiparallel-domain (OFF) state. Measuring time scans of the resistance changes between the ON and OFF state, ${\Delta}R_{ON-OFF}$, while alternating magnetic fields between the two states at various temperatures and bias currents, revealed that enhancement of ${\Delta}R_{ON-OFF}$ is a key factor to achieve successful operation of superconducting spin switch.

A Study on the potential measurement of pipeline using IR Free reference electrode (IR Free 전극을 이용한 전위측정에 관한 연구)

  • Ha, Tae-Hyun;Bae, Jeong-Hyo;Lee, Hyun-Goo;Kim, Dae-Kyeong;Ha, Yoon-Cheol
    • Proceedings of the KIEE Conference
    • /
    • 2003.07d
    • /
    • pp.2735-2737
    • /
    • 2003
  • Measurement of the potential of a buried pipeline using the Cu/$CuSO_4$ reference electrode is the most widely used method for the estimation of the corrosion susceptibility of the pipeline. The recorded values, however, include inevitable errors due to the IR drop caused by the stray currents. In this paper, we describe the characteristics of the IR-free reference electrode used for more accurate measurement of the pipe line potential.

  • PDF

A Study on Modeling of Leakage Current in ESS Using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 ESS의 누설전류 모델링에 관한 연구)

  • Kim, Ji-Myung;Tae, Dong-Hyun;Lee, Il-Moo;Lim, Geon-Pyo;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.810-818
    • /
    • 2021
  • A leakage current of ESS is classified mainly by the occurrence from a PCS(Power Conditioning System) section and an unbalanced grid current. The reason for the leakage current from the PCS section is a voltage change by IGBT (Insulated Gate Bipolar Transistor) switching and stray capacitance between the IGBT and heatsink. The leakage current caused by the grid unbalanced current flows to the ESS through the neutral line of grid-connected transformer for the ESS with a three limb iron type of Yg-wire connection. This paper proposes a mechanism for the occurrence of leakage current caused by stray capacitance, which is calculated using the heatsink formula, from the aspect of the PCS section and grid unbalance current. Based on the proposed mechanisms, this study presents the modeling of the leakage current occurrence using PSCAD/EMTDC S/W and evaluates the characteristics of leakage currents from the PCS section and grid unbalanced current. From the simulation result, the leakage current has a large influence on the battery side by confirming that the leakage current from the PCS is increased from 7[mA] to 34[mA], and the leakage current from an unbalanced load to battery housing is increased from 3.96[mA] to 10.76[mA] according to the resistance of the housings and the magnitude of the ground resistance.

A Study on the Flow Characteristics around Intakes within a Sump by PIV (PIV에 의한 흡입수조내 흡입관 주위의 유동특성에 관한 연구)

  • Choi, J. W.;Kim, J. H.;Kim, K. Y.;Kim, Y. T.;Lee, Y. H.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.5 no.3 s.16
    • /
    • pp.33-39
    • /
    • 2002
  • The head-capacity corves for pumps developed by the pump manufacturer are based on tests of a single pump operating in a semi-infinite pool with no nearby walls or floors and with no stray currents. Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. However, various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found in pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface, side-wall, and back-wall due to different clearances from back-wall to vortical intake pipe. Moreover, the locations and patterns of the various types of vortices that were found in the examinations are discussed.

A study on the Flow Characteristics of a Vortex originated in the Free Surface within a Sump in a Pump Station by PIV (PIV에 의한 펌프장 흡입수조의 자유표면에서 발생하는 와의 운동특성에 관한 연구)

  • Choi, J. W.;Kim, B. S.;Lee, H.;Kim, Y. T.;Lee, Y. H.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.95-101
    • /
    • 2002
  • The head-capacity curves for pumps developed by the pump manufacturer are based on tests of a sin91e pump operating in a semi-infinite pool with no nearby walls or floors and no stray currents. Hence, flow into the pump suction is symmetrical with no vortices or swirling. Pump station designers rely on these curves to define the operating conditions for the pump selected. But various constraints such as size, cost, and limitations on storage time require walls, floors, and pump intakes to be close proximity to each other. From this background, the authors are carrying out a systematic study on the flow characteristics of intakes within a sump found within a sump of pump stations. Model pump intake basin is designed and PIV is adopted as a measuring tool to capture the instantaneous flow patterns. Special attention is paid to investigate the flow patterns near the free surface due to different clearances from back-wall to vertical intake pipe with bell mouse and without. Moreover, the locations and vorticities of the various types of vortices that were found in the examinations are discussed.

  • PDF