• 제목/요약/키워드: Strain Type

Search Result 2,469, Processing Time 0.033 seconds

The Strain of Flexible Ring Type Valve used for Refrigeration Compressor (냉동압축기용(冷凍壓縮機用) 환상형토출(環狀型吐出)밸브의 변형(變形))

  • Jeong, J.W.;Jo, K.O.
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.17 no.2
    • /
    • pp.150-158
    • /
    • 1988
  • On a refrigeration compressor, damage of a discharge valve is one of the annoying troubles for an engineer. Small size compressors, having ring plate type discharge valve are recently used. Therefore, it is very important for engineers to measure and analyze strains of discharge valve. The purpose of this study is to obtain the basic data of the strain of the flexible ring valve. Measurements were performed by the strain gauge bonded on the surface of the flexible ring valve. Stress and strain of the valve were calculated by the method of uniformly loaded circular plates with a central hole. The results obtained are as follows; (1) the strain of flexible ring discharge valve in refrigeration compressor was influenced by tension and compression strain simultaneously. (2) for a given discharge pressure, the tangential and radial strains was increased with increasing discharge pressure. (3) the valve of radial strain was larger than that of tangential strain.

  • PDF

Determination of true stress-strain curve of type 304 and 316 stainless steels using a typical tensile test and finite element analysis

  • Kweon, Hyeong Do;Kim, Jin Weon;Song, Ohseop;Oh, Dongho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.2
    • /
    • pp.647-656
    • /
    • 2021
  • Knowing a material's true stress-strain curve is essential for performing a nonlinear finite element analysis to solve an elastoplastic problem. This study presents a simple methodology to determine the true stress-strain curve of type 304 and 316 austenitic stainless steels in the full range of strain from a typical tensile test. Before necking, the true stress and strain values are directly converted from engineering stress and strain data, respectively. After necking, a true stress-strain equation is determined by iteratively conducting finite element analysis using three pieces of information at the necking and the fracture points. The Hockett-Sherby equation is proposed as an optimal stress-strain model in a non-uniform deformation region. The application to the stainless steel under different temperatures and loading conditions verifies that the strain hardening behavior of the material is adequately described by the determined equation, and the estimated engineering stress-strain curves are in good agreement with those of experiments. The presented method is intrinsically simple to use and reduces iterations because it does not require much experimental effort and adopts the approach of determining the stress-strain equation instead of correcting the individual stress at each strain point.

Association of a Provisional New emm Type Opacity Factor-Negative Group A Streptococci Strain ST4529 with Septicemia

  • R.R. Rantty;M. Eshaghi;A.M. Ali;F. Jamal;K. Yusoff
    • Journal of Microbiology
    • /
    • v.39 no.3
    • /
    • pp.236-239
    • /
    • 2001
  • Group A Streptococcus strain ST4529 is a provisional new ems type which has been recently reported in Malaysia (Jomal, et al. 1999. Energ. Infect . Dis. 5,10-14). This strain was found to be opacity factor (OF) negative with a Tl phenotype. Usually, OF negative strains with T1 phenotypes are associated with acute rheumatic fever. However, strain ST4529 was isolated from the blood of a patient with septicemia. Comparison of the deduced amino acid sequence of the mature hypervariable N-terminus of ST4529 showed only 43% identity with that of M5, the closest matched OF negative strain with a T1 phenotype. Thus, ST4529 most probably encodes a new serospecifically unique M protein which is associated with septicemia rather than pharyngitis infections. The strains with these phenotypes are very important because their sequences should be considered for developing any anti-streptococcal vaccines.

  • PDF

Fatigue Strength Evaluation on the IB-Type Spot Welded Lap Joint of 304 Stainless Steel Part 2 : Strain energy Density (304 스테인레스 박강판 IB형 용접이음재의 피로강도 평가 Part 2 : 변형에너지 밀도에 의한 평가)

  • 손일선;오세빈;배동호
    • Journal of Welding and Joining
    • /
    • v.17 no.6
    • /
    • pp.32-37
    • /
    • 1999
  • Since stainless steel plates have good mechanical properties, weldability, appearance and resistance of corrosion, these are traditionally used for vehicles such as the bus and the train. And they are mainly fabricated by spot welding. But fatigue strength of their spot welded joint is considerably influenced by welding conditions as well as geometrical factors. Thus a reasonable and systematic criterion for long life design of spot welded body structure must be established. In this report, strain energy density was analyzed by using 3-dimensional finite element model about the IB-type spot welded lap joint under tension-shear load. Fatigue tests were conducted on them having various thickness, joint angle, lapped length and width. From their results, it was found that fatigue strength of the IB-type spot welded lap joints could be effectively and systematically rearranged by strain energy density at the edge of nugget.

  • PDF

VISUALIZATION OF INTERNAL DEFECTS IN PLATE-TYPE NUCLEAR FUEL BY USING NONCONTACT OPTICAL INTERFEROMETRY

  • Park, Seung-Kyu;Park, Nak-Gyu;Baik, Sung-Hoon;Kang, Young-June
    • Nuclear Engineering and Technology
    • /
    • v.45 no.3
    • /
    • pp.361-366
    • /
    • 2013
  • An imaging technique to visualize the internal defects in a plate-type nuclear fuel specimen was developed by using an active optical interferometer for a nondestructive quality inspection. A periodic thermal wave having a sinusoidal intensity pattern induced a periodical strain variation for the specimen. The varying strain image was acquired using an optical laser interferometer. The strain distribution over the internal defects will be distorted in an acquired strain image because a part of the thermal wave will be reflected from these defects during propagation. In this paper, internal defects were efficiently visualized by sequentially accumulating the extracted defect components. The experimental results confirmed that the developed visualization system can be a valuable tool to detect the internal defects in plate-type nuclear fuel.

Selective Isolation and Characterization of Schwanniomyces castellii Mutants with Increased Production of a-Amylase and Glucoamylase

  • Ryu, Yeon-Woo
    • Journal of Microbiology and Biotechnology
    • /
    • v.3 no.2
    • /
    • pp.95-98
    • /
    • 1993
  • This study was carried out to isolate and characterize the mutant strains of Schwanniomyces castellii NRRL Y-2477. Mutants were prepared with the treatment of ethyl methane sulfonate. 2-deoxy-D-glucose resistant mutants were isolated and two mutants were selected based on their high production of amylolytic enzymes and their ability to ferment starch. The mutants selected had higher a-amylase and glucoamylase activities than the wild type strain from several other carbon sources. Especially, it was revealed that mutant strain M-9, when cultured in the presence of glucose as a sole carbon source, shows relatively high activities of a-amylase and glucoamylase compared to those of the wild type strain. In result, this mutant strain can be considered as a constitutive producer of amylolytic enzymes. To compare the ethanol production ability of wild type strain and of mutant strains selected, an alcohol fermentation was carried out using 100 g/l soluble starch. Mutant strain M-9 did not improve the direct alcohol fermentation of starch, despite its excellent amylolytic activities performance. On the other hand, mutant strain M-6 produced 37.9 g/l (4.8%, v/v) ethanol by utilizing about 82% of substrate.

  • PDF

Measurement of Real Deformation Behavior in C-type Lng Mock-up Tank using Strain Gage (스트레인 게이지를 이용한 C-type LNG Mock-up 탱크 내조 실 변형 거동 측정)

  • Jung, Won-Do;Kim, Tae-Wook;Kim, Jeong-Hyeon;Lee, Do-Young;Chun, Min-Sung;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.117-124
    • /
    • 2016
  • A C-type LNG mock-up tank was constructed to evaluate the durability of the tank and its structural safety. An experimental strain analysis system equipped with strain gages was designed to investigate the structural behavior of the inner tank at a high hydraulic pressure. In addition, the insulation used in the space between the inner tank and outer tank had a compressive strength and the inner tank thickness of the cylindrical shell and hemisphere was 4.0 mm, which was designed to be thinner than the existing rules. The strains on the inner tank were measured with increasing pressure, and these measurements were compared and analyzed at the strain gage attachment points.

A Comparative Study on Arrhenius-Type Constitutive Models with Regression Methods

  • Lee, Kyunghoon;Murugesan, Mohanraj;Lee, Seung-Min;Kang, Beom-Soo
    • Transactions of Materials Processing
    • /
    • v.26 no.1
    • /
    • pp.18-27
    • /
    • 2017
  • A comparative study was performed on strain-compensated Arrhenius-type constitutive models established with two regression methods: polynomial regression and regression Kriging. For measurements at high temperatures, experimental data of 70Cr3Mo steel were adopted from previous research. An Arrhenius-type constitutive model necessitates strain compensation for material constants to account for strain effect. To associate the material constants with strain, we first evaluated them at a set of discrete strains, then capitalized on surrogate modeling to represent the material constants as a function of strain. As a result, disparate flow stress models were formed via the two different regression methods. The constructed constitutive models were examined systematically against measured flow stresses by validation methods. The predicted material constants were found to be quite accurate compared to the actual material constants. However, notable mismatches between measured and predicted flow stresses were revealed by the proposed validation techniques, which carry out validation with not the entire, but a single tensile test case.

Durability Assessment of Geogrids by Reduction Factors (감소인자에 의한 지오그리드의 내구성 평가)

  • Jeon, Han Yong;Heo, Dai Young
    • Journal of the Korean Geosynthetics Society
    • /
    • v.3 no.2
    • /
    • pp.31-38
    • /
    • 2004
  • Long-term stability of two type geogrids were evaluated. Membrane drawn type geogrid showed the exponential type tensile property and textile type geogrid showed the rapid increase of tensile property closer toward the break point. Accelerated creep test was done for textile type geogrid but not done for membrane drawn type geogrid because of its thermal property. Creep strain for membrane drawn type geogrid was larger than the ultimate tensile strain by tensile test and reduction factor by creep deformation of textile type geogrid was smaller than that of membrane type geogrid.

  • PDF

A Study on a Highly Sensitive Strain Sensor based on Rayleigh Wave (레일리파 기반의 고감도 변형률 센서에 관한 연구)

  • Lee, Ki Jung;Jo, Minuk;Fu, Chen;Eun, Kyoungtae;Oh, Haekwan;Choa, Sung-Hoon;Yang, Sang Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.495-501
    • /
    • 2014
  • Piezoresistive-type, capacitive-type, and optical-type sensors have mainly been used for measuring a strain. However, in building a sensor network for remote monitoring using these conventional sensors there are disadvantages such as the complexity of a measuring system including wireless communication circuitry and high cost. In this paper, we demonstrates a highly-sensitive surface acoustic wave (SAW) strain sensor which is advantageous to harsh environments and wireless network. We designed and fabricated the SAW strain sensor. The SAW strain sensor attached on a specimen was tested with a tensile tester. The strain on the sensor surface was measured with a commercial strain gauge and compared with that obtained from strain analysis. The central frequency shift of the SAW sensor was measured with a network analyzer. The sensitivity of the SAW strain sensor is 134 $Hz/{\mu}{\varepsilon}$ which is high compared to previous results.