• Title/Summary/Keyword: Strain Sensors

Search Result 538, Processing Time 0.026 seconds

A Study of Deflection of Ceramic Diaphragm for a Pressure Sensor (후막저항의 기하학적 위치에 따른 압력센서의 출력특성 고찰)

  • Lee, Seong-Jae;Lee, Deuk-Young;Ha, Young-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.884-887
    • /
    • 2003
  • Strain gages were widely used transducers. Essentially a strain gage was an electric element to which an appropriate type was attached. Strain was sensed by gages and provided electrical output proportional to applied forced. This paper describes the recent development of a thick film strain gage ceramic pressure sensors. The thick film resistors as strain gage in the Wheatstone bridge were fabricated with a novel mixture of ruthenium. The thick-film technology of resistors were printed on the ceramic diaphragm back side by screen printing and cured at $850^{\circ}C$. The mechanical measurements were performed with the computer simulation results(ANSYS 5.1). The output sensitivity was 1.2mV/V, of which max. nonlinearity was less than 0.29%, hysteresis was less than 0.38%FS.

  • PDF

Strain Sensors Using Carbon Nanotube Composites (탄소나노튜브 복합 소재를 이용한 스트레인 센서)

  • Kang, In-Pil;Schulz Mark J.;Choi, Gyeong-Rak;Choi, Yeon-Sun;Lee, Jong-Won
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.16 no.7 s.112
    • /
    • pp.762-768
    • /
    • 2006
  • To address the need for new intelligent sensing of systems, this study presents a novel strain sensor based on piezoresistivity of carbon nanotube (CNT) and its nanocomposites. Fabrication and characterization of the carbon nanocomposite material are discussed and an electrical model of the CNT strain sensor was derived based on electrochemical impedance spectroscopy analysis and strain testing. The dynamic response of the sensor on a vibrating beam was simulated using numerical analysis and it was compared with experimental test. The simulation showed good agreement with the strain response of the actual sensor.

Influence of Stain on the High Frequency Impedance of Highly Magnetostrictive Films (고자왜막의 고주파임피던스에 미치는 스트레인의 영향)

  • ;M. Inoue;K. I, Arai
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.1
    • /
    • pp.47-51
    • /
    • 2000
  • To make a practical application of a micro-strain sensors with ultrahigh sensitivity, a strain on electrical properties of micro-patterned amorphous (Fe\ulcornerco\ulcorner)\ulcornerSi\ulcornerB\ulcorner films had influenced on the impedance over frequency range from 1 MHz to 1 GHz. Reflecting excellent magnetomachanical couping properties of films, high frequency impedance was subject to change sensitively by a strain : a change in impe-dance of 39% was observed at 200 MHz applied a strain of 224$\times$10\ulcorner. To determine a optimum shape of micro-patterned films, film impedance was analyzed by virtue of its constitutive components of resis-tance and reactance. Result was shown that reduction of the resistance term(hence increase of resultant reactance term) of impedance is more effective for enhancing the strain sensitivity of films at relatively low frequency range.

  • PDF

Strain Sensors Using Carbon Nanotube Composites (탄소나노튜브 복합 소재를 이용한 스트레인 센서)

  • Kang, In-Pil;Schulz, Mark J.;Lee, Jong-Won;Choi, Gyeong-Rak;Choi, Yeon-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.930-935
    • /
    • 2006
  • To address the need for new intelligent sensing of systems, this study presents a novel strain sensor based on peizoresistivity of carbon nanotube (CNT) and its nanocomposites. Fabrication and characterization of the carbon nanocomposite material are discussed and an electrical model of the CNT strain sensor was derived based on electrochemical impedance spectroscopy analysis and strain testing. The dynamic response of the sensor on a vibrating beam was simulated using numerical analysis and it was compared with experimental test. The simulation showed good agreement with the strain response of the actual sensor.

  • PDF

16 Channel Strain Gauge Measuring Ubiquitous System Development (유비쿼터스 지향의 16채널 스트레인 게이지 계측 시스템 개발)

  • Jang, Soon-Suk;Kim, Kyung-Suk;Won, Yong-Ill;Kim, Dae-Gon
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.9
    • /
    • pp.912-917
    • /
    • 2006
  • A strain gauge weight measuring instrumentation system was designed with RF sensor network facilities. In the sensor module system data conversion and a series of signal processing were totally equipped. 16 strain gauges are incoming sensors and each output of the strain gauge was amplified and filtered for proper analog signal processing. Several measuring instrumentation OP amps and general purposed OP amps were used. 12 bits A/D converters converted analog signals to digital bits and a PIC microprocessor controlled the 16 channels of strain gauges. RF RS232 modules were used for wireless communication between the PIC microprocessor and an Ethernet host far a remote sensor monitoring system development.

Strain and Temperature Measurement using Transmission-type EFPI Optical Fiber Sensors (투과형 EFPI 광섬유 센서를 이용한 변형률 및 온도의 측정)

  • Kim, Sang-Hoon;Lee, Jung-Ju;Huh, Jeung-Soo
    • Journal of Sensor Science and Technology
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 2001
  • The extrinsic Fabry-Perot interferometric (EFPI) optical fiber sensor shows good sensitivity and resolution, and has many advantages over optical fiber sensors of other types. However, this EFPI optical fiber sensor has a disadvantage that the distinction of measuring directions is difficult due to the measurement method by using only fringe counting. In this paper, the transmission-type extrinsic Fabry-Perot interferometric (TEFPI) optical fiber sensor was developed, which has been improved by the additional function and whose measuring system is different from that of the conventional EFPI optical fiber sensor. Then the application result of the TEFPI optical fiber sensor to the strain and temperature measurement was explained in detail.

  • PDF

Damage detection of reinforced concrete columns retrofitted with FRP jackets by using PZT sensors

  • Tzoura, Efi A.;Triantafillou, Thanasis C.;Providakis, Costas;Tsantilis, Aristomenis;Papanicolaou, Corina G.;Karabalis, Dimitris L.
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.2
    • /
    • pp.165-180
    • /
    • 2015
  • In this paper lead zirconate titanate transducers (PZT) are employed for damage detection of four reinforced concrete (RC) column specimens retrofitted with carbon fiber reinforced polymer (CFRP) jackets. A major disadvantage of FRP jacketing in RC members is the inability to inspect visually if the concrete substrate is damaged and in such case to estimate the extent of damage. The parameter measured during uniaxial compression tests at random times for known strain values is the real part of the complex number of the Electromechanical Admittance (Conductance) of the sensors, obtained by a PXI platform. The transducers are placed in specific positions along the height of the columns for detecting the damage in different positions and carrying out conclusions for the variation of the Conductance in relation to the position the failure occurred. The quantification of the damage at the concrete substrate is achieved with the use of the root-mean-square-deviation (RMSD) index, which is evaluated for the corresponding strain values. The experimental results provide evidence that PZT transducers are sensitive to damage detection from an early stage of the experiment and that the use of PZT sensors for monitoring and detecting the damage of FRP-retrofitted reinforced concrete members, by using the Electromechanical Admittance (EMA) approach, can be a highly promising method.

Design, calibration and application of wireless sensors for structural global and local monitoring of civil infrastructures

  • Yu, Yan;Ou, Jinping;Li, Hui
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.641-659
    • /
    • 2010
  • Structural Health Monitoring (SHM) gradually becomes a technique for ensuring the health and safety of civil infrastructures and is also an important approach for the research of the damage accumulation and disaster evolving characteristics of civil infrastructures. It is attracting prodigious research interests and the active development interests of scientists and engineers because a great number of civil infrastructures are planned and built every year in mainland China. In a SHM system the sheer number of accompanying wires, fiber optic cables, and other physical transmission medium is usually prohibitive, particularly for such structures as offshore platforms and long-span structures. Fortunately, with recent advances in technologies in sensing, wireless communication, and micro electro mechanical systems (MEMS), wireless sensor technique has been developing rapidly and is being used gradually in the SHM of civil engineering structures. In this paper, some recent advances in the research, development, and implementation of wireless sensors for the SHM of civil infrastructures in mainland China, especially in Dalian University of Technology (DUT) and Harbin Institute of Technology (HIT), are introduced. Firstly, a kind of wireless digital acceleration sensors for structural global monitoring is designed and validated in an offshore structure model. Secondly, wireless inclination sensor systems based on Frequency-hopping techniques are developed and applied successfully to swing monitoring of large-scale hook structures. Thirdly, wireless acquisition systems integrating with different sensing materials, such as Polyvinylidene Fluoride(PVDF), strain gauge, piezoresistive stress/strain sensors fabricated by using the nickel powder-filled cement-based composite, are proposed for structural local monitoring, and validating the characteristics of the above materials. Finally, solutions to the key problem of finite energy for wireless sensors networks are discussed, with future works also being introduced, for example, the wireless sensor networks powered by corrosion signal for corrosion monitoring and rapid diagnosis for large structures.

Monitoring of Low-velocity Impact Damage Initiation of Gr/Ep Panel Using Piezoelectric Thin Film sensor (압전필름센서를 이용한 복합재 평판의 저속충격 손상개시 모니터링)

  • 이관호;박찬익;김인걸;이영신
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.174-178
    • /
    • 2001
  • The piezoelectric thin film sensor can be used to interpret variations in structural and material properties, e.g. for structural integrity monitoring and assessment. To illustrate one of this potential benefit, PVDF film sensors are used for monitoring impact damage initiation in Gr/Ep composite panel. Both PVDF film sensors and strain gages are surface mounted to the Gr/Ep specimens. A series of impact test at various impact energy by changing impact mass and height is performed on the instrumented drop weight impact tester. The sensor responses are carefully examined to predict the onset of impact damage such as matrix cracking, delamination, and fiber breakage, etc. Test results show that the particular waveforms of sensor signals implying the damage initiation and development are detected above the damage initiation impact energy. As expected, the PVDF film sensor is found to be more sensitive to impact damage initiation event than the strain gage.

  • PDF

Measurement of Load Transfer between Anchor and Grout using Optical FBG Sensors embedded in Smart Anchor (FBG 센서가 내장된 스마트 앵커를 이용한 앵커와 그라우트의 하중전이 측정)

  • Suh, Dong-Nam;Kim, Young-Sang;Kim, Jae-Min
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.03a
    • /
    • pp.505-510
    • /
    • 2008
  • FBG Sensor, which is smaller than strain gauge and has better durability and does not have a noise from electromagnetic waves, was adapted to develope a smart anchor. A series of pullout tests were performed to verify the feasibility of smart anchor and find out the load transfer mechanism around the steel wire fixed to rock with grout. Distribution of shear stresses at steel wire-grout interface is assessed from the measured strain distribution by the optical fiber sensors and compared with stress distributions predicted by Farmer's and Aydan's formulas. It was found that present theoretical formulas may underestimate the failure depth and magnitude of shear stresses when the pullout loads increase.

  • PDF