• Title/Summary/Keyword: Straight length

Search Result 514, Processing Time 0.022 seconds

A Study on the Transition of Costume in Middle and high School Girls Using the "Junior"magazine ("주니어" 잡지를 중심으로 본 교복장율화 이후의 여학생 복식 변천에 관한연구)

  • 남혜승
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.1
    • /
    • pp.401-414
    • /
    • 1997
  • This study examined the transition of costume in middle and high school girls after the abolition of school-uniform. Fashion photographs of $\ulcorner$Junior$\lrcorner$a Korean magazine for girls were used for the investigation. Skirts used mainly were changed in order of pleat tight flare and tight skirt And skirt length was changed in order of knee midi knee and mini. Slim baggy and straight pants together showed high frequency but after 1992 straight pants were used mainly. And pants of ankle length was prevalent. In jacket Hip line natural waist and H-line silhouette dominated. Silhouette of one-piece dress was changed in order or X line H line and A line. Semi fit and natural waist were prevalent. And length was changed in order of midi knee and mini. The coat of H line Loose semi fit and Knee length was the most frequently appeared style. Waist line of coat was changed in order of natural low no natural waist. In skirt blue white black and black were mainly in spring summer fall and winter respectively. In pants blue was used mainly regardless of the season, In jacket blue in spring and black in other seasons were used. In one-piece derss blue in spring red in summer black in fall and winter were used mainly. Black coat was used mainly. Therefore blue was the most frequently used color by middle and high school girls.

  • PDF

Voice transformation for HTS using correlation between fundamental frequency and vocal tract length (기본주파수와 성도길이의 상관관계를 이용한 HTS 음성합성기에서의 목소리 변환)

  • Yoo, Hyogeun;Kim, Younggwan;Suh, Youngjoo;Kim, Hoirin
    • Phonetics and Speech Sciences
    • /
    • v.9 no.1
    • /
    • pp.41-47
    • /
    • 2017
  • The main advantage of the statistical parametric speech synthesis is its flexibility in changing voice characteristics. A personalized text-to-speech(TTS) system can be implemented by combining a speech synthesis system and a voice transformation system, and it is widely used in many application areas. It is known that the fundamental frequency and the spectral envelope of speech signal can be independently modified to convert the voice characteristics. Also it is important to maintain naturalness of the transformed speech. In this paper, a speech synthesis system based on Hidden Markov Model(HMM-based speech synthesis, HTS) using the STRAIGHT vocoder is constructed and voice transformation is conducted by modifying the fundamental frequency and spectral envelope. The fundamental frequency is transformed in a scaling method, and the spectral envelope is transformed through frequency warping method to control the speaker's vocal tract length. In particular, this study proposes a voice transformation method using the correlation between fundamental frequency and vocal tract length. Subjective evaluations were conducted to assess preference and mean opinion scores(MOS) for naturalness of synthetic speech. Experimental results showed that the proposed voice transformation method achieved higher preference than baseline systems while maintaining the naturalness of the speech quality.

An Investigation of the Major Factors Relating to the Flow Fluctuation at a Natural Gas Metering Facility (천연가스 계량설비에서 발생하는 유량 헌팅 현상 원인 분석)

  • An, Seung-Hee;Her, Jae-Young;Jeong, Jong-Tae;Sin, Chang-Hun
    • 유체기계공업학회:학술대회논문집
    • /
    • 2005.12a
    • /
    • pp.158-165
    • /
    • 2005
  • KOGAS(Korea Gas Corporation) has about a hundred of local stations to supply natural gas to the city gas companies and the power stations. As some severe flow fluctuation phenomena are observed in several governor stations, the investigation about the reasons and factors which are relating to flow fluctuation has been started. Some field surveys hav been carried out and experimental studies have been performed to find the fluctuation mechanism. As a result, it is found that the flow fluctuation is related with the length of straight pipe in front of the meter, the size of the header pipe and the variation of demand at the city gas company and the power station. Furthermore. it is also proved that both the length of the transmitter cable and the status of the coating of signal transmission cable do not affect flow fluctuation, but the measurement range of the differential pressure transmitter influences flow fluctuation. On the other hand, as the averaging the flow fluctuation is converged to less than 0.1 % in almost all of the cases, it is concluded that the quantity of flow fluctuation do not relates to metering accuracy directly.

  • PDF

Calculation and Mitigation of Magnetic Field Produced by Straight Line-Conductor with Finite Length (유한장 직선도체에 의한 자계의 계산 및 감소대책)

  • Kang, Dae-Ha
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.57-67
    • /
    • 2011
  • Purpose of this study is to find the mitigation method of magnetic field by finite length multi-conductors such as indoor distribution lines and to be applicable to design of the distribution lines. For this purpose, exact formula about the components $B_x$, $B_y$, $B_z$ of magnetic field need in case of straight line-conductor with finite length forward any direction. In this study simple formula of the components were deduced and by using these formula magnetic fields for various models of line-configurations were calculated. And also a calculation method of induced currents in conductive shield was presented and using this method, programing of calculation is relatively easy and calculation time is short. The magnetic field after cancellation by these induced currents was calculated. All of calculations were performed by Matlab 7.0 programs. Through the calculation results it could be obtained followings for the mitigation of magnetic fields. The separation between conductors ought to be smaller than smaller as possible. In case of 3-phase, delta configuration is more effective than flat configuration. In case of 3-phase, unbalanced currents ought to be reduced as possible.. In case of more than two circuits of 3-phase, adequate locations of each phase-conductor such as rotating configuration of 3-phase conductors are more effective. The magnetic shielding effect of the conductive shielding sheet is very high.

Electric Device Character and fabrication of advanced thin film including nano particles (나노입자가 내장된 기능성 박막의 제작과 전자소자 특성)

  • Ryu, Jeong-Tak;Ikuno, T;Honda, S.;Katayama, M.;Oura, K.
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.11 no.4
    • /
    • pp.66-71
    • /
    • 2006
  • Carbon nanofibers have synthesized a low temperature using DC Ar plasma and Fe-Phthalocyanine, and a characteristic difference of the synthesized CNF according to the location of the substrate was investigated. The carbon nanofibers had about 100nm diameter and up to $10{\mu}m$ length. These were grown in random orientation. There are two shapes in the CNFs, screw and straight line shapes. Furthermore, we found the selective growth of nanofibers on the scratched substrates. The density of CNFs synthesized on the position (a) were higher than that synthesized on the position (b) [See the Fig. 2]. Also, the length of CNFs was different. In the shape, CNFs with screw and straight line shape were synthesized in the position (a), but. only CNFs with straight line shape were synthesized in the position (b). The difference have an important effect on the field emission characteristics.

  • PDF

The Kinematic Analysis of the Pitching motion for the Straight and Curve ball (직구와 커브 투구동작의 운동학적 비교 분석)

  • Lee, Young-Jun;Kim, Jung-Tae
    • Korean Journal of Applied Biomechanics
    • /
    • v.12 no.2
    • /
    • pp.109-130
    • /
    • 2002
  • The purpose of this paper was to make a comparative analysis for the difference of the various kinematic variation which is occurred in the each situation when pitchers throw a straight and a curve ball. Four pitchers, who are two national team players and two high level pitchers, were selected among the right over hand pitchers of D university in the Busan for this paper. The data were analyzed by using 3D equipment. The results of the analysis which was about the elapsed time of the pitching, the movement of the body center-point, the highest height of the left knee, stride length, knee joint angle, shoulder joint angle, elbow joint angle and wrist joint angle in the each section(ST, LKU, HBP, LCF, MCP, BRP) were as follows : 1. Pitching time in the each section and step in the pitching for straight and curve ball was similar. The total elapsed time of the straight and curve ball was 1.78${\pm}$0.07sec and 1.77${\pm}$0.11sec in the order. 2. The position change of the body center to the Z(above below) direction did not show significant difference in the each situation of the section and step between pitching for the straight and curve ball. 3. Height of the left knee did not show significant difference as 125.38${\pm}$11.85cm and 124.95${\pm}$11.63m in the each pitching motion for straight and curve ball. The rate(%H) between height and stride length showed 68.42${\pm}$5.53(%H), 68.40${\pm}$5.45(%H) in the each pitching motion. 4. Pitching for curve ball showed longer stride length than pitching for straight ball that as the stride length was 140.35${\pm}$4.96cm and 144.8${\pm}$1.69cm. The rate(%H) between height and stride length showed 76.9${\pm}$3.77(%H), 79.39${\pm}$2.23(%H) in the each pitching motion. 5. Left knee joint angle did not show significant difference in the ST, LKU and HBP section in the each pitching motion. However, it was shown that knee joint angle was flexed much more in the LFC, MCP and BRP section in the pitching for curve ball. 6. Right shoulder joint angle did not show significant difference in the ST, LKU and HSP section. However, when pitches threw a curve ball in the LKU section. In the LFC section, the right shoulder joint angle was extended much more in the pitching for curve ball, and the angle was extended much in the MCP and BRP section in the pitching for curve ball than straight ball. 7. Right elbow joint angle did not show significant difference in the ST, LKU and HRP section in the two pitching motion. The angle had more flexion in the LFC and MCP section in the pitching for curve ball than the pitching for straight ball. The angle in the each pitching motion for straight ball and curve ball were extended by a narrow margin in the BRP section. 8. Right wrist joint angle was extended much more in the LFC and MCP section in the pitching for curve ball. In the BRP section, the angle was extended much more in the pitching for straight ball than curve ball.

A study on the variation of orifice diameter in a straight pipe giving dqual-sampling rate (직선배관에서 균일한 공기 흡입을 하는 오리피스 직경변화에 대한 연구)

  • Kim, Jin-Guk
    • Fire Protection Technology
    • /
    • s.24
    • /
    • pp.17-22
    • /
    • 1998
  • The objective of this paper is to investigate the variation of orifice diameter in a straight pipe which can give equal-sampling rate. This can be utilized for designing orifice in air-sampling smoke detector. The elements which should be considered for designing orifices was presented and the calculation procedure was also given in this paper. The effects of pipe length, the number of orifices, fan pressure was decribed.

  • PDF

Effect of Recycled PET Fiber Geometry and Length on the Plastic Shrinkage Cracking of Cement Based Composites (재생 PET 섬유의 형상 및 길이가 시멘트 복합 재료의 소성 수축 균열에 미치는 영향)

  • Won, Jong-Pil;Park, Chan-Gi;Kim, Hwang-Hee;Lee, Sang-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.2
    • /
    • pp.233-239
    • /
    • 2007
  • The main objective of this study was to evaluate the effect of recycled PET fiber made from waste PET bottle on the control of plastic shrinkage cracking of cement based composites. PET is blown as a plastic material and used in a variety products such as a beverage bottle. However, waste PET bottles are thrown after the usage, raising huge problems in terms of the environment. Thus, the research on the method to recycle the PET bottles indicates important aspects in environment and economy. The method to recycle waste PET bottles as a reinforcing fiber for cement based composites is one of effective methods in terms of the recycle of waste PET bottles. In this research, the effect of recycled PET fiber geometry and length on the control of plastic shrinkage was examined through thin slab tests. A test program was carried out to understand the influence of fiber geometry, length and fiber volume fraction. Three type of recycled PET fibers including straight, twist crimped and embossed type. Three volume fraction and two fiber length were investigated for each of the three fiber geometry. Test results indicated that recycled PET fibers are effective in controlling plastic shrinkage cracking in cement based composites. In respect to effect of length of fiber, longer fiber was observed to have efficient cracking controlling with low volume fraction in same fiber geometry while shorter fiber controled plastic shrinkage cracking efficiently as addition rate increase. Also, embossed type fibers were more effective in controlling plastic shrinkage cracking than other geometry fiber at low volume fraction. But, for high volume fraction, straight type fibers were most effective in plastic shrinkage cracking controlling in cement based composites.

A Study on Error Characteristic of Flow Disturbance and Velocity for Electromagnetic and Ultrasonic Flowmeters (유속과 유동교란인자에 의한 전자식 및 초음파식 유량계의 오차특성 연구)

  • Lee, Dong-Keun;Park, Jong-Ho
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.33-38
    • /
    • 2009
  • In this study, the effect of flow disturbance such as contraction, expansion pipe and velocity deviation from low velocity of $0.1\;^m/s$ to $2.5\;^m/s$ on the error characteristics of the flowmeter was studied. Flow experiments using flowmeter calibration facility of K-water were undertaken for the cases of ultrasonic flowmeter based on transit-time method and electromagnetic flowmeter. Experimental results are presented that measurement error of expansion pipe are larger than contraction pipe. It is shown that the minimum straight length were required to remain of ${\pm}0.5%$ error for electromagnetic flowmeter and ${\pm}2.0%$ error for ultrasonic flowmeter.

The Effect of Distance between $90^{\circ}$Elbow close to Upstream Face of Orifice Plate and Orifice Plate on Discharge Coefficient (오리피스 전단에 인접한 $90^{\circ}$엘보와 오리피스간의 거리가 유출계수에 미치는 영향)

  • Yoon Joon-yong;Sung Nak-won
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.357-360
    • /
    • 2002
  • The effect of distance between ninety degree elbow close to upstream face of orifice plate and orifice plate on discharge coefficient was investigated. The distributions of discharge coefficient and differential pressure caused by elbow and short upstream straight length were examined and modified discharge coefficient was introduced. The results presented in this study could be useful when orifice plate is installed under the condition of simple flow disturbance element and short upstream straight length.

  • PDF