• 제목/요약/키워드: Straight installation

검색결과 53건 처리시간 0.024초

전력계통의 전자과도현상에 관한 연구 (A Study on the Electromagnetic Transients in A Power System)

  • 김경철;강창원;이일무
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.59-64
    • /
    • 2001
  • Transient in an electrical system are generated by lightning and switching. This paper presents analysis of switching and lightning surge, and means of limiting the voltage magnification transient for high voltage power systems by using EDSA's EMTAP software package. One means of limiting the voltage magnification transient is to convert the end-user power factor correction banks to harmonic filters. An inductance in series with the power factor correction bank was used to decrease the transient voltage at the customer bus to acceptable levees. The interception of the impulse from the phase wire is fairly straight forward by properly installed surge arresters. The simulation shows that the addition of the surge arrester at the customer location can achieve a substantial reduction of the transient magnitude.

  • PDF

Grounding Characteristic Analysis of Plate Electrodes

  • Kim, Sung-Sam;Kim, Ju-Chan;Koh, Hee-Seog
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.53-60
    • /
    • 2007
  • In this study, an experiment on the efficient construction method of plate electrodes, the influence of electric potential interference in plate electrodes, and building foundations were explored. The experimental result of the electric potential measurement was taken on the basis of the direction of movement and the condition in which the plate electrodes are laid underground in building foundations. It shows that the construction method of laying the plate electrodes vertically exhibits a more efficient reduction of electric potential in a diagonal direction and on an X axis than laying plates horizontally. For plate electrode construction in an area that has uniform conditions, the parallel joint construction method is more effective than a single construction to reduce earth electrical potential and ground resistance. In addition, a straight arrangement performs well in ground efficiency, compared to the parallel arrangement.

전기설비용 Epoxy 복합재료의 유전특성 (The Dielectric Characteristics Epoxy Composite Material for Electric Installation)

  • 이보호;박동화;이병기
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제7권2호
    • /
    • pp.51-56
    • /
    • 1993
  • Epoxy 복합재료의 충전제 및 수분함유의 유전특성에 대한 영향을 고찰한 결과를 요약하면 다음과 같다. 1) ${\varepsilon}_\tau$의 주파수 의존성은 시편1과 시편2의 경우에서 $140^{\circ}C$이하에서 직선적인 특성을 나타내고 있으며 수분의 함유시에도 직선적인 변화를 하고 있으므로 주파수나 습도 센서소자로서 개발이 가능하다. 2) 100[Hz]~3[kHz]의 범위에서 $tan{\delta}$ 주파수 의존성은 캐리어 이동에 의한 도전손실 보다 쌍극자완화에 의한 손실이 지배적이며 수분에 영향은 낮은 주파수에서 크게 받는다.

  • PDF

모래지반에서 말뚝의 모양과 설치방법이 모형말뚝의 극한상장지지력에 미치는 영향 (A Study on the Influences of Shape and Installion Method on the Ultimate Uplift Capacity of Model Piles in Sand)

  • 송영우
    • 한국지반공학회지:지반
    • /
    • 제8권3호
    • /
    • pp.5-12
    • /
    • 1992
  • 본 논문은 모래지반에 박힌, 기하학적 특성과 설치방법이 서로 다른 모형말뚝의 극한상장지지력에 대한 연구이다. 기하학적 특성의 측면으로는 균일직편말뚝, 선단확대말뚝, 다층확대말뚝과 앵커플레이트가 시험되고 기일직경말뚝에 대한 말뚝설치방법이 극한지지력에 미치는 영향을 조사하기 위해 매설, ao입, 진동관입방법이 연구되었다. 실험결과에 의하면 기초가 상장력과 압축력을 받는 경우에는 선단확대 말뚝이, 오직 상장력에 대해서는 앵커플레이트가 가장 효과적이며, 또한 말뚝설치방법 및 타입 말뚝의 선단 모양은 상장지지목에 큰 영향을 준다는 것이 밝혀졌다.

  • PDF

속도위반단속시스템에 의한 주행속도 특성 변화에 관한 연구 (A Study on the Variations of Runing Speed Characteristics by Automated Speed Enforcement System)

  • 김완기;류부형
    • 한국안전학회지
    • /
    • 제25권2호
    • /
    • pp.78-83
    • /
    • 2010
  • An installation of automated speed enforcement system(ASES) was known for traffic safety and accident preventive effects that traffic characteristics transmute by speed distribution stabilizing. This study is verified the variations of average speed, 85% speed, speed distribution and dispersion as traffic characteristics depend on enforcement system influences in the road. We tested selected 5 areas. By and large, it has a little differences depend on road geometric structure and traffic environment but that is not too much. After all, after automated speed enforcement system installed in all of test areas, average speed, 85% accumulated speed, speed distribution and dispersion characteristics were declined and equalized. The speed dispersion was smaller than before installed the ASES. The speed dispersion value of each case that is the limited speed has been 70Km/h, 80Km/h at flat and straight, 80Km/h at downhill and straight or downhill and left-curved area was 77.3%, 65.2%, 68.7% and 54.1%. Each of the data was declined. We could analyze that average speed distributed depletion factor was declined rapidly by 66.3% in test area.

국내 태양광시스템 설치지역을 위한 일조시간에 의한 일사예측에 관한 연구 (A Study on the Estimating Solar Radiation Using Hours of Bright Sunshine for the Installation of Photovoltaic System in Korea)

  • 조덕기;윤창열;김광득;강용혁
    • 한국태양에너지학회 논문집
    • /
    • 제31권4호
    • /
    • pp.72-79
    • /
    • 2011
  • Solar radiation data are the best source of information for estimating average incident radiation. Lacking this or data from nearby locations of similar climate, it is possible to use empirical relationships to estimate radiation from days of hours of bright sunshine. It is necessary to estimate the regression coefficients in order to predict the daily global radiation on a horizontal surface. Therefore many different equations have proposed to evaluate them for certain areas. In this work a new correlation has been made to predict the solar radiation for 16 different areas over Korea by estimating the regression coefficients taking into account hours of bright sunshine. Particularly, the proposed straight line regression model shows reliable results for estimating the global radiation on a horizontal surface with monthly average deviation of -0.2 to +0.5% and each station annual average deviation of -1.6 to +1.7% from measured values.

곡관의 하류에 설치된 전자기유량계의 유량신호 특성에 관한 실험적 연구(난류 유동) (An Experimental Study on Installation Effects of Pipe Elbow on the Electromagnetic Flowmeter Characteristics (Turbulent Flow))

  • 임기원
    • 대한기계학회논문집B
    • /
    • 제26권11호
    • /
    • pp.1613-1621
    • /
    • 2002
  • An electromagnetic flowmeter(EMF) essentially averages the velocity distribution over the pipe cross- sectional area, and the measured value is dependent on the velocity profiles. In this study, installation effects of 90$^{\circ}$long elbow(KS B 1522, ISO 3419) on the EMF characteristics was investigated. A commercial EMF was adopted and the distribution of magnetic field in the electrodes cross section was measured. In the experiment, the national flow standard system, of which measurement uncertainty was evaluated in accordance with ISO 17025 recommendation, was used fur characterization of EMF. The leading line has 150D long straight pipe to established a fully developed flow before entering into the elbow and the elbow was installed downstream of it. then the flowmeter was tested within 50 D from the elbow. The installation effects of the flowmeter were investigated by varying the mean velocity(Reynolds No.)in pipe section, the locations and the direction of electrodes plane.($\phi$) From the experimental results, we find the optimal conditions to get most accurate measurements. Generally, the deviations from the calibration value were less than 0.5 % in farther than 10D distance from the elbow and the direction of electrode plane. $\phi$ = 90$^{\circ}$yielded the smallest measurement deviation. These characteristics were shown consistently in turbulent region regardless of the mean Reynolds number.

방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구 (A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume))

  • 안양기;김지영;김금희;장희수;정정필;최종우
    • 한국유체기계학회 논문집
    • /
    • 제18권6호
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.

전위강하법에 의한 접지저항측정에 미치는 전류보조전극의 영향 (Effects of the Current Probe on Ground Resistance Measurements Using Fall-of-Potential Method)

  • 이복희;엄주홍
    • 조명전기설비학회논문지
    • /
    • 제14권6호
    • /
    • pp.69-77
    • /
    • 2000
  • 본 논문에서는 찬우$\mid$강하법에 의한 접지저항 및 대지첸위 분표의 측캠시 전휴보조전극의 영향에 대하여 기술하였으며, 측정시 오치를 최소화하는 기법을 제안하였다. 전위강해법은 전위와 천류의 측정에 이론적인 비1깅을 두고 있으며, 측정오차는 주로 측정시 설치하는 보조전극의 위치와 자체저항에 기인한다. 피측정 접지전극의 접지저항은 전위강하법에서 전위보조전극을 피측정 접지전극과 전류보조전극이 이루는 일직선상에 위치시킬 때 61.8[%]법칙을 적용하여 측정한다. 하지만 건물이나 포장도로, 구조물 등이 산재해 있는 도심의 경우에는 현장에서 피측정 접지전극과 전류보조전극 사이에 적결한 이격거리 확보가 불가능하거냐 전류보조전극의 접지저행값이 피측정 챔 지전극에 비하여 큰 값을 가지는 경우가 있다. 파측정 접지천극과 전류보조전극을 충분히 이격시키지 않거나 전류류보조전극의 접지저항값이 피측청 접지전극의 접지저항보다 비정상척으로 큰 경우 접지저항의 측정은 오차를 수반하게 되며, 측정된 접지저항값은 오차즐 보정해 주어야 한다. 본 연구애서 측정대상 전극은 길이 2.4[m]의 봉형 접지전극으호 하였으며, 전류보조전극의 영향을 고려할 때 피측정 접지전극과 전류보조전극의 적정한 이격거리는 피측정 접치전극 길이의 5배 이상으로 하여야 전위보조전극을 사설하기가 용이하며 측정정확도의 확보에 유리하다. 또한 전류보존전극의 접지저항값이 피측정 접지전극의 접지저항값 약 36.5배 이하에서는 거의 오차를 발생시키지 않는다.

  • PDF

케이블형 Wi-Fi 기반 실내 공간의 노드 배치 판별 분석에 관한 연구 (A study on the discriminant analysis of node deployment based on cable type Wi-Fi in indoor)

  • 진현철;김원열;김종찬;김윤식;서동환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제40권9호
    • /
    • pp.836-841
    • /
    • 2016
  • Wi-Fi를 이용한 실내 위치인식 시스템은 2차원 이상의 실내 공간 정보와 노드 위치정보 등이 결합된 무선 신호 지도의 제작이 필수적이다. 이를 구성하기 위한 과정인 Wi-Fi 노드의 RSSI 측정 및 배치 정보 확인에 시간 비용이 크게 발생한다. 특히 기존의 무선 환경이 변하거나 새로운 공간이 만들어질 경우 실내 위치기반의 서비스를 제공하기 위해 노드의 재설치 및 새로운 실내 무선 지도 제작이 필요하다. 이러한 문제로 인해 발생되는 시간 소비를 줄이기 위하여 본 논문에서는 3 m 간격으로 설치된 Cable형 Wi-Fi를 사용하여 정확한 노드의 배치 위치를 판별 및 공간 분석이 가능한 RSSI 가시화 및 Sobel 필터 기반 경계선 검출을 통해 복도 구간의 직선과 곡선을 구분하는 알고리즘을 제안한다. Cable형 Wi-Fi는 동일한 전력선으로 연결되어 있으므로 노드가 일정한 간격으로 설치된 순서를 알 수 있다는 장점이 있다. 이를 기반으로, 공간의 특정 구간을 분석이 가능하도록 측정된 RSSI 기반 가시화과정을 통해 신호의 분포를 확인하고 이를 Sobel 필터 기반 경계선 검출 및 Total RSSI Distribution(TRD) 연산을 통하여 분석한다. Raw data와 제안하는 알고리즘 신호강도를 비교해본 결과 제안하는 알고리즘의 신호 세기는 곡선 구간에서 경계선 특성이 평균 13.73 % 증가하였다. 또한 직선 구간 신호의 세기를 평균 34.16 % 감소시켜 직선구간과 곡선구간의 특성이 개선되었다.