• Title/Summary/Keyword: Storm Drainage

Search Result 129, Processing Time 0.026 seconds

Characteristics of Suspended Solids Export from Paddy Fields (논에서의 SS 유출 특성)

  • Lee, Kyoungsook;Jung, Jaewoon;Choi, Dongho;Yoon, Kwangsik;Choi, Woojung;Choi, Soomyung;Lim, Sangsun;Park, Hana;Lim, Byungjin;Choi, Gangwon
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.6
    • /
    • pp.868-876
    • /
    • 2011
  • A five-year field monitoring was conducted to monitor characteristics of suspended solid (SS) export from paddy fields. The observed EMCs of SS ranged 1.2~517 mg/L (avg. 52.1 mg/L) during storm period. The concentration of SS during non-storm period were 1.1~349.5 mg/L (avg. 36.1 mg/L). Monthly load of SS was high during summer when rainfall amount was high. The load was higher than that of May when tillage effect is expected. There was no significant relationship between SS EMCs and rainfall or drainage amount. However, effects of rainfall and drainage were found to be significant for event load of SS. But, there was no apparent relationship between rainfall amount of cropping period and load of SS for that period. The observed SS load was 164.8~456.0 kg/ha (avg. 301.2 kg/ha) and mostly occurred during storm period. This study results also suggested that SS load estimation by USLE equation for paddy field could be overestimated, if not carefully handled. Monitoring studies for various climate, soil, and agricultural management are required to get better scope of SS export from paddy fields.

A Technique of Inland Drainage Control Considering flood Characteristics of the Han River (한강홍수특성을 고려한 내배수 처리기법)

  • Lee, Won Hwan
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.1
    • /
    • pp.99-108
    • /
    • 1991
  • Rapid changes of urban hydrologic events need new management operation rule of detention reservoir which is essential outflow control system in urban area. Therefore, this study is to develop the outflow management method of Seoul city considering the Han river flood characteristics, to analyze the inundation of detention reservoir according to variation of design storm patterns, and to examine the safety of gate due to design flood water level. From this study, new operation rule is presented. The design storm patterns are determined by instantaneous intensity method and Huff's quartile method. And the inflow hydrograph of detention reservoir is obtained by applying ILLUDAS model and RRL method. The operation rule of existing drainage pump is designed to have linear relation between storage and pumping discharge. But in this study, it is effective for preventing inundation when the operation rule of drainage pump have Gaussian function which is combined the storage of detention reservoir with its inflow according to increasing or decreasing of inflow hydrograph.

  • PDF

A Study for the Computer Simulation on the Flood Prevention Function of the Extensive Green Roof in Connection with RCP 8.5 Scenarios (RCP 8.5 시나리오와 연동한 저관리형 옥상녹화시스템의 수해방재 성능에 대한 전산모의 연구)

  • Kim, Tae Han;Park, Sang Yeon;Park, Eun Hee;Jang, Seung Wan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • Recently, major cities in Korea are suffering from frequent urban flooding caused by heavy rainfall. Such urban flooding mainly occurs due to the limited design capacity of the current drainage network, which increases the vulnerability of the cities to cope with intense precipitation events brought about by climate change. In other words, it can be interpreted that runoff exceeding the design capacity of the drainage network and increased impervious surfaces in the urban cities can overburden the current drainage system and cause floods. The study presents the green roof as a sustainable solution for this issue, and suggests the pre-design using the LID controls model in SWMM to establish more specific flood prevention system. In order to conduct the computer simulation in connection with Korean climate, the study used the measured precipitation data from Cheonan Station of Korea Meteorological Administration (KMA) and the forecasted precipitation data from RCP 8.5 scenario. As a result, Extensive Green Roof System reduced the peak runoff by 53.5% with the past storm events and by 54.9% with the future storm events. The runoff efficiency was decreased to 4% and 7%. This results can be understood that Extensive Green Roof System works effectively in reducing the peak runoff instead of reducing the total stormwater runoff.

Affecting Discharge of Flood Water in Paddy Field from Selecting Rainfall with Fixed and Unfixed Duration (고정, 임의시간 강우량 선택에 따른 농경지 배수 영향 분석)

  • Hwang, Dong Joo;Kim, Byoung Gyu;Shim, Jwa Keun
    • KCID journal
    • /
    • v.19 no.1
    • /
    • pp.64-76
    • /
    • 2012
  • Recently, it has been increased disaster of crops and agricultural facilities with climate change such as regional storm, typhoon. However agricultural facilities have unsafe design criteria of improving drainage corresponding to this change. This study has analyzed the impact that inundation area and magnitude of drainage-facility is decided based on fixed- and unfixed-duration precipitation by applying revised design criteria of drainage for climate change. The result was shown that 1-day and 2-days rainfall for 20-years return period has increased about 11.4%, 4.4% respectively by changing fixed- to unfixed duration. And the increase rate of design flood was 15.0%. The result was also shown that Inundation area was enlarged by 6.6% as well as increased inundation duration under same basic condition in designed rainfall between fixed- and unfixed-duration. According to the analysis, it is necessary for pump capacity in unfixed-duration to be increased by 70% for same effect with fixed-duration. Therefore, when computing method of probability precipitation is changed from fixed one to unfixed-duration by applying revised design criteria, there seems to be improving effect in drainage design. Because 1440-minutes rainfall for 20-years return period with unfixed-duration is more effective than 1-day rainfall for 30-years return period with fixed-duration. By applying unfixed-duration rainfall, capacity of drainage facilities need to be expanded to achieve the same effects (Inundation depth & duration) with fixed-duration rainfall. Further study is required for considering each condition of climate, topography and drainage by applying revised design criteria.

  • PDF

An Analysis of Flow Characteristics with Changing the Inside Shapes in Square Manhole (직사각형 맨홀의 내부형상변화에 따른 흐름특성 분석)

  • Jang, Suk-Jin;Yoon, Young-Noh;Kim, Jung-Soo;Yoon, Sei-Eui
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.199-202
    • /
    • 2007
  • In storm sewer networks a lot of manholes are installed to maintain and connect a sewer of urban area. There are some shapes of manhole such as circular type, square type, and so on. Square shape manholes are installed to connect the large diameter drainage pipes in general and have lager head losses than circular one. Consequently, it is important to analyze the head losses in square manhole because the head losses in square manhole are much bigger than the friction losses in pipes. Hydraulic experimental apparatus which can be changed the inside shape in square manhole was installed for this study. The experimental discharge was $16{\ell}/sec$. The head loss coefficients in the manhole were calculated by the experimental results. The range of head loss coefficients in the general square manhole were from 0.33 to 0.48 and the range of head loss coefficients in the square manhole changed inside shape were from 0.23 to 0.28.

  • PDF

Runoff Analysis Using a Distributed Rainfall-Runoff Model (분포형 강우-유출 모형에 의한 유출 해석)

  • 신사철
    • Water for future
    • /
    • v.29 no.6
    • /
    • pp.131-139
    • /
    • 1996
  • The main goal of this study is a rainfall-runoff analysis using atopographically-based distributed model. It consists of two parts: one is a direct runoff submodel and the other is a baseflow submodel. The direct runoff submodel is a distributed model which routed through the drainage networks with a kinematic wave model. The baseflow submodel is considered as a lumped system. This model makes it possible to take the effect of areal and temporal distribution of storm into accout.

  • PDF

An Estimation of NPS Pollutant Loads using the Correlation between Storm Water Runoff and Pollutant Discharge in a Small Urban Drainage Basin (도시소유역에서의 유출과 비점원오염물 배출 간의 상관관계 수립에 의한 NPS 오염물 배출량의 산정)

  • 신현석;윤용남
    • Water for future
    • /
    • v.26 no.4
    • /
    • pp.85-95
    • /
    • 1993
  • Three purposes of this study are as follows: The first was the development of the extention method for the limited data observed in an urban drainage basin. The second was the analysis of the correlation between storm water runoff and NPS(non-point source) pollutant discharge, The last was the calculation of the monthly and annual specific NPS loads using the established correlation. the selected model was the SWMM monthly and annual specific NPs loads using the established correlation. The selected model was the SWMM (Storm Water Management model) developed by the US EPA(environmental Protection Agency). As a result of this study, the best correlation between storm wate runoff and NPS pollutants discharge was produced by the non-linear correlation between runoff rate(mm/hr)and specific loads rate(g/ha/sec)for all pollutants studied ; SS, COD, BOD, and TN. The best correlation through the analysis based on evently total mass was made by the linear correlation between the specific accumulated runoff(mm) and the specific accumulated loads(kg/ha) for CASE 1., and by the non-linear correlation for CASE 2. The NPS annual specific loads for the urban basin studied were 4933 kg/ha/year for SS, 775kg/ha/year for BOD, 3094kg/ha /year for COD,257kg/ha/year for TN, respectively. And the proportion of the NPS annual specific loads to the total annual specific loads were 42 % for SS, 13 % for BOD, 29% for COD, and 21 % for TN.

  • PDF

The Performance of Pollutant Removal Using Nonpoint Treatment Filtration Device and Analysis of the Filter Backwashing Effect (여과형 비점오염 처리장치의 오염물질 제거특성 및 역세척 분석)

  • Lee, Jun-ho;Yang, Seung-ho;Bang, Ki-woong
    • Journal of Korean Society on Water Environment
    • /
    • v.31 no.5
    • /
    • pp.523-532
    • /
    • 2015
  • Hydrocyclone is widely used in industry, for its simple design, high capacity, low maintenance and low operational cost. The objective of this study is to develop hydrocyclone coagulation and filtration system. The system is made of hydrocyclone ballasted coagulation with polyaluminium chloride silicate (PACS) and upflow filter to treat micro particles in urban storm runoff. Roadside sediment particles (< $200{\mu}m$) was mixed with tap water to make various turbid suspensions to simulate urban storm runoff. The filter cartridge was filled with polyethylene media system and ran 1hr per everyday and total operation time were 8.19hrs and backwashing everyday after end of operation. The operation condition of flowrate was $8.2{\sim}11.9m^3/day$ (mean $10.1m^3/day$) and surface overflow rate (SOR) based on filter surface area was $45.5{\sim}65.9m^3/m^2/day$ (mean $55.7m^3/m^2/day$). The range of PACS dosage concentration was 14.0~31.5 mg/L. As the results of operation, the range of removal efficiency of turbidity, SS were 81.0~95.8% (mean 89.5%) 81.8~99.0% (mean 91.4%), respectively. An increase of filtration basin retention time brought on increased of removal efficiency of turbidity and SS, and increase of SOR brought on decreased of removal efficiency. During the first flush in urban area, storm runoff have an high concentration of SS (200~600 mg/L) and the filtration bed becomes clogged and decreased of removal efficiency. Backwashing begins when the drainage pipe valve at the filtration tank bottom is completely open (backwashing stage 1). Backwashing stage 2 was using air bubbles and water jet washing the media for 5 mins and open the drainage valve. After backwashing stage 1, 2, 61.83~64.04%, 18.53~27.51% of SS loading was discharged from filtration tank, respectively. Discharged SS loading from effluent was 7.12~14.79% and the range of residual SS loading in fliter was 2.26~5.00%. The backwashing effects for turbidity, SS were 89.5%, 91.4%, respectively. The hydrocyclone coagulation and filtration with backwashing system, which came out to solve the problems of the costly exchange filter media, and low efficiency of removing micro particles of filter type nonpoint treatment devices, is considered as an alternative system.

Areal Rainfall Analysis using Grid Method (격자법을 이용한 면적강우 분석)

  • Lee Yong-il
    • KCID journal
    • /
    • v.1 no.2
    • /
    • pp.36-47
    • /
    • 1994
  • 미국 펜실베이니아 주의 4개 지역에 대해 면적우량을 분석하였다. 강수량이 제일 큰 지점에서 시작하여 이 지점 주위로 직사각형의 블럭을 확장하여 만들었다. 이 직사각형 블럭의 강수량을 구한 후 최대 지점 강수량에 대한 비를 구하였다. 이 강수량 비(Relative storm magnitudes)를 플롯트하여 기존의 커브와 비교하였으며, 각 지역에 대해 여름과 겨울의 강수량비를 각각 구하였다. 또한 등우량선도를 이용한 분석도 시도해 보았다. 이 연구에서 구

  • PDF

Application of Rainfall-Runoff Models and Provision of Radar Rainfall Data during Flood in Imjin River Basin (임진강 유역의 홍수기 강우-유출모형 적용 및 레이더강우 자료의 활용방안)

  • Kim Seong-joon;Park Roh-hyuk;Maeng Sung-jin
    • KCID journal
    • /
    • v.5 no.1
    • /
    • pp.47-62
    • /
    • 1998
  • The purpose of this study is to evaluate storm runoff models of Imjin river basin(8,117.5$km^2$) for the provision of radar rainfall situation. Two lumped models, Storage Function Model(SFM) and HEC-1 model which are now in use broadly and prov

  • PDF