• Title/Summary/Keyword: Storage facilities

Search Result 823, Processing Time 0.028 seconds

Microbiological Evaluation for HACCP System Application of Green Vegetable Juice Containing Lactic Acid Bacteria (유산균을 함유한 녹즙의 HACCP 시스템 적용을 위한 미생물학적 위해도 평가)

  • Kwon, Sang-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.4924-4931
    • /
    • 2011
  • This research performed to evaluate a production processes reporting by the HACCP system of green vegetable juice products, containing lactic acid bacteria, stage of processing raw materials agricultural products and production facilities of general bacteria and pathogenic micro organism. General bacteria are found from four samples of storage of agricultural products at process stage and water was detected 8.67~14.67 CFU/ml. However, all samples were detected less than 105 CFU/ml as a legal standards after the process of UV sterilization. For the outcome of experiment of E.coli, E.coli O157:H7, B.cereus, L.moonocytogenes, Salmonella spp, Staph.aureus as the food poisoning bacterial, E.coli was detected until UV pre-step process in storage process and B.cereus was detected partly till 1st washing. Since all bacterial, Yeast and Mold are detected in main materials, pre-control method is a necessary to establish for decreasing with a number of initial bacteria of main materials and it is considered to establish the effective ways of washing and sterilization such as production facilities for cross contamination prevention of bacteria and Sthaphylococcus. Based on above results, the process of UV sterilization should be managed with CCP as an important process to reduce or eliminate the general and food poisoning bacterial of green vegetable juice products, including lactic acid bacteria. Therefore, it is considered to need an exhaustive HACCP plan such as control manual of UV sterilization, solution method, verification, education and training and record management.

A Study on Risk Assessment of extreme Cold Waves in Energy Storage Facilities According to Climate Change (기후변화에 따른 에너지 저장시설 극한 한파 위험성 평가에 관한 연구)

  • Han-Duk Kim;Eun-Gu Ham;Se-Young Ko
    • Journal of the Society of Disaster Information
    • /
    • v.20 no.3
    • /
    • pp.584-592
    • /
    • 2024
  • Purpose: The biggest concern in cold wave situations is that the fire extinguishing water initially supplied through dry pipes with empty pipes consumes enthalpy and freezes as it rapidly approaches the surface temperature of steel pipes that have been exposed to sub-zero outdoor air for a long time. It has no choice but to be. Method: Therefore, the study found that ice crystals were generated during transport, making it difficult to transport fire extinguishing water, and as a result of the review, when the heat load passed through the piping material, the heat loss per unit length from the piping to the surroundings was 0.946. Results: When calculating the volume of the main pipe, it was calculated that the fire extinguishing water supplied at a temperature of 15 degrees from the underground pipe would have a volume of 3.33m3 to reach the first branch point. If we calculate the heat required until this volume reaches below zero, we get 316.350 kcal. When the results were reviewed using the related formula, the time required for the fire extinguishing water to completely freeze up to the first branch of the steel pipe was found to be 3,412 seconds. Conclusion: Fire-fighting water, which must reach from the main pipe to the branch pipe and nozzle in good condition, must minimize heat loss through the pipe surface along the transfer path. To achieve this, it is necessary to supplement insulation of the main pipe and branch pipes. In this study, the use of inorganic perlite material or flame-retardant rubber foam insulation was proposed through analysis of insulation properties.

Investigation of ground condition charges due to cryogenic conditions in an underground LNG storage plant (지하 LNG 저장 시험장에서 극저온 환경에 의한 지반상태 변화의 규명)

  • Yi Myeong-Jong;Kim Jung-Ho;Park Sam-Gyu;Son Jeong-Sul
    • Geophysics and Geophysical Exploration
    • /
    • v.8 no.1
    • /
    • pp.67-72
    • /
    • 2005
  • To investigate the feasibility of a new concept of storing Liquefied Natural Gas (LNG) in a lined hard rock cavern, and to develop essential technologies for constructing underground LNG storage facilities, a small pilot plant storing liquid nitrogen (LN2) has been constructed at the Korea Institute of Geoscience and Mineral Resources (KIGAM). The LN2 stored in the cavern will subject the host rock around the cavern to very low temperatures, which is expected to cause the development of an ice ring and the change of ground condition around the storage cavern. To investigate and monitor changes in ground conditions at this pilot plant site, geophysical, hydrogeological, and rock mechanical investigations were carried out. In particular, geophysical methods including borehole radar and three-dimensional (3D) resistivity surveys were used to identify and monitor the development of an ice ring, and other possible changes in ground conditions resulting from the very low temperature of LN2 in the storage tank. We acquired 3D resistivity data before and after storing the LN2, and the results were compared. From the 3D images obtained during the three phases of the resistivity monitoring survey, we delineated zones of distinct resistivity changes that are closely related to the storage of LN2. In these results, we observed a decrease in resistivity at the eastern part of the storage cavern. Comparing the hydrogeological data and Joint patterns around the storage cavern, we interpret this change in resistivity to result from changes in the groundwater flow pattern. Freezing of the host rock by the very low temperature of LN2 causes a drastic change in the hydrogeological conditions and groundwater flow patterns in this pilot plant.

A Study on the POE (Post Occupancy Evaluation) according to the Residential Environment of Mixed-use Apartment Complexes In Seoul

  • Ha, Man Joon
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.2
    • /
    • pp.197-212
    • /
    • 2020
  • In this study, POE(Post Occupancy Evaluation) evaluation indexes were selected into six categories through the consideration of theories and prior research. Therefore, qualitative supply can be achieved through POE according to the aspect of residential environment after the quantitative supply of mixed-use apartment complex by the population concentration in Seoul due to industrialization and urbanization. As the evaluation elements, detailed survey contents were selected for livability, convenience, comfort, safety, economy, and sociality. Based on the survey contents, six elements were evaluated and analyzed using Data coding and Likert scale after surveying 12 complexes (Urban areas and non-urban areas) in Seoul. As a result of the study, six categories selected as the POE showed that importance of quality of life and safety was developed in high recognition according to high satisfaction with convenience and safety. Sociality showed the lowest satisfaction in the following order : livability, comfort, economy and sociality. Residents' sense of community, interaction with neighborhood, etc., showed low satisfaction, and it seems that it is necessary to improve and supplement the system for the development of mixed-use apartment complex in the future. The detailed characteristics of livability showed high satisfaction of the living room, the front door and the main room which are main uses of housing, and low satisfaction in storage size. The analysis of convenience is that convenient public transportation was the highest, and educational environment and additional facilities were the lowest, showing the advantages and disadvantages of location characteristics. As a result of the analysis of comfort, satisfaction with the landscape area was low and it seems that green space is needed for the development of mixed-use apartment complex in the future. Lastly, regarding the safety, the satisfaction of the access control, the location of security office, etc. were high, however separation of circulation was low. Therefore, it is necessary to clearly separate the circulation between the residence and other facilities in the mixed-use apartment complex.

Assessment of Foodservice Management Performance at Child Care Centers (보육시설 급식운영관리 실태 조사)

  • Lee Mee-Sook;Lee Jae-Yeon;Yoon Sun-Hwa
    • Korean Journal of Community Nutrition
    • /
    • v.11 no.2
    • /
    • pp.229-239
    • /
    • 2006
  • This study was carried out to investigate foodservice management practices of 100 child care centers nationwide, and to provide background information for developing foodservice management policies at child care centers. Approximately 20% of the child care centers had a separate dining room; most of the centers were vulnerable to sanitation or safety problems. The percentage of the centers that planned menus was about 60% and 10% established standardized recipes. Fourteen percent of the centers kept records for distribution and menu evaluation and 33% kept sanitation management records. Since only 7% of the centers employed a dietitian, foodservice in most centers were not managed by professionals. The results of menu assessment revealed that 56.5% of the national/public child care centers received 19 points or higher out of 21 points, whereas 5.6% of the private child care centers received the same scores. Proper usage and storage of raw food, sanitary management of equipment and facilities, waste management/leftover food treatment, and basic facility of cooking zones were performed well by many centers. The overall scores of foodservice performance were only 31.2 out of 60 points, representing relatively poor safety management, food procurement management, and facilities and equipment management. These results indicate that the foodservice management of the child care centers are in a relatively poor state. Since nutrition management of the most centers was performed by non-professionals, it may not be possible to provide proper nutrition for health and normal growth of preschool children and to perform efficient nutrition education programs. The following suggestions are strongly recommended in order to improve foodservice performance at child care centers. First, foodservice administration should be performed by a dietitian, and second, efforts should be focused on strengthening nutrition and sanitation management.

Job Perception and the Need for Job Improvement among School Nutrition Teachers in Seoul (서울지역 일부 학교 영양교사의 직무에 대한 인식과 개선 요구도)

  • Kim, Seoung-Hee;Lee, Kyung-Eun;Kim, Jin-Sook
    • Korean Journal of Community Nutrition
    • /
    • v.21 no.1
    • /
    • pp.12-24
    • /
    • 2016
  • Objectives: The objectives of the study were to investigate the school nutrition teachers' perception on their job and to find out recommendations needed for its improvement in order to provide a quality foodservice and nutrition education at schools. Methods: A total of 219 school nutrition teachers in Seoul were surveyed using selfadministered questionnaires. Results: The perceived importance of the 16 job duties was rated 3.8 based on a 5-point scale (1: very unimportant - 5: very important). The importance of six duties including nutrition management, production management, nutrition education, and food safety management were rated over 4 point but that of record-keeping for documents, official reporting, and service management was rated the lowest. Importance-Performance Analysis showed that nutrition management, receiving/storage management, production management, menu management, food safety management, and equipment/facilities management should be emphasized to maintain the current performance of duties. The performance of the nutrition education and counseling needed to be improved since the importance scores were greater than average but the performance scores were lower than the average. Official reporting and miscellaneous jobs were rated the highest for simplification need. More than half of the respondents agreed that equipment/facilities management, miscellaneous jobs, service staff supervision, and service line supervision could be allocated to other school departments. Conclusions: School nutrition teachers should invest more time and resources on their core job duties such as nutrition management, production management, food safety management, and nutrition education for providing quality foodservice and nutrition education. To reflect the environmental changes of school foodservice, a reasonable staffing index of school nutrition teachers needs to be developed. In addition, hiring an assistant or implementing school nutrition teacher internship programs can be useful to reduce workloads of the nutrition teachers.

An experimental study on the low temperature melting treatment of waste asbestos for using (폐석면의 활용을 위한 저온 용융처리에 대한 실험적 연구)

  • Song, Tae Hyeob;Kim, Young Hun;Park, Ji Sun;Lee, Sea Hyun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.83-90
    • /
    • 2010
  • As a reinforced fabric, asbestos has been utilized as a fire-resistant material as it has a superior flexural stiffness and heat resistance up to $1500^{\circ}C$. However, due to its harmfulness, its use has been prohibited recently and the even the installed asbestos materials are being repaired or supplemented if there is a concern about flying. Asbestos is mainly used for construction panels as a reinforced fabric and coating materials to ensure the fire-resistance of steel frames. Asbestos was used as fire-resistant materials for steel frames until 1991 and then prohibited as Act on Industrial Safety and Health limits the concentration of asbestos in the air. Classified as a designated waste according to Act on Waste Control, asbestos must be buried if there is no possibility of flying (panel-type materials) or cement-solidified and then buried if there is a possibility of flying (spray coating material) In general, it is required that a new waste landfill include a certain landfill facility for designated waste, but in reality there is an absolute storage of landfill facilities for designated waste as they only install facilities of the size required by the regulations. This could result in the 2nd environmental pollution as they cannot process asbestos wastes which will be generated in large volume in the future. This study explores a method that melts asbestos wastes at $700^{\circ}C$ rather than cement-solidifying the waste asbestos from construction sites, especially asbestos-containing spray coating. The study results showed that there was no change in the composition and shape even though asbestos wastes was melted at $1300^{\circ}C$, but there was a change for the specimen which was process in advance for low temperature melting and then melt at $900^{\circ}C$.

  • PDF

A Study on Quantitative Risk Presentation of LNG Station (LNG충전시설의 위험도 표현에 관한 연구)

  • Ko, Jae-Wook;Yoo, Jin-Hwan;Kim, Bum-Su;Lee, Heon-Seok;Kim, Min-Seop
    • Journal of the Korean Institute of Gas
    • /
    • v.13 no.1
    • /
    • pp.61-67
    • /
    • 2009
  • There are lots of energy facilities using gas(storage facility, compressed gas pipe, station, tank lorry) on the domestic. These major gas facilities cause major accidents associated with fire, explosion, toxic and etc. With the increased interest in reducing air pollution, supply of natural gas for gas vehicles is increasing. Thus, the number of establishments of LNG (Liquefied Natural Gas) and CNG(Compressed Natural Gas) stations is increasing as well. However, due to major gas accidents such as the fire and explosion accident of a Buchen LPG (Liquefied Petroleum Gas) station, it is difficult to establish a new station. In this research, we present quantitative risk assessment for LCNG;LNG multi-station and compare it result against individual risk criteria of HSE.

  • PDF

A Preliminary Study of Licensing Facilitation Standards for Improvements in Quality for Childcare Centers (보육시설의 질적 향상을 위한 설치기준에 관한 기초연구)

  • Kim, Youug-Aee;Choi, Mock-Wha;Park, Juug-A
    • Korean Journal of Human Ecology
    • /
    • v.20 no.3
    • /
    • pp.691-711
    • /
    • 2011
  • This study examines the preliminary license and approval facilitation standards for improvements in quality for childcare centers focusing on the number of children, building space standards, facilities and equipment, and childcare program. Data from 48 caese was collected from childcare centers nationwide in Korea through a questionnaire and building plan. The first step for starting care licensing is to work out the ages and numbers of children within four or five age ranges. The second step is to work out the number of children as small, medium, or large considering staff to child ratios and building size. The Nnext step is to make a choice about childcare service quality classification as minimum, fair, or good, considering space requirements per child for the building, the classroom and the outdoor playground. The next step is to make a choice of space organization relating to service programs, considering the sleeping and eating area, indoor play area, toilet & washing facilities, classroom layouts such as cluster type, double zone type, single zone type, and others. Also, each room and entrance, office, kitchen, storage, laundry, teacher's area, and chilldren's area, need to be checked for space requirements and performances. The last step is to arrange the childcare program with the building and site plan. In conclusion childcare service quality will get better by upgrading of license regulation especially in minimum space requirements per child, corresponding with an increase in GNP and housing area per person. This is needed for childcare licensing in order to determine the quality level of childcare service.

A correlation method for high-frequency response of a cargo during dry transport in high seas

  • Vinayan, Vimal;Zou, Jun
    • Ocean Systems Engineering
    • /
    • v.6 no.2
    • /
    • pp.143-159
    • /
    • 2016
  • Cargo, such as a Tension Leg Platform (TLP), Semi-submersible platform (Semi), Spar or a circular Floating Production Storage and Offloading (FPSO), are frequently dry-transported on a Heavy Lift Vessel (HLV) from the point of construction to the point of installation. The voyage can span months and the overhanging portions of the hull can be subject to frequent wave slamming events in rough weather. Tie-downs or sea-fastening are usually provided to ensure the safety of the cargo during the voyage and to keep the extreme responses of the cargo, primarily for the installed equipment and facilities, within the design limits. The proper design of the tie-down is dependent on the accurate prediction of the wave slamming loads the cargo will experience during the voyage. This is a difficult task and model testing is a widely accepted and adopted method to obtain reliable sea-fastening loads and extreme accelerations. However, it is crucial to realize the difference in the inherent stiffness of the instrument that is used to measure the tri-axial sea fastening loads and the prototype design of the tie-downs. It is practically not possible to scale the tri-axial load measuring instrument stiffness to reflect the real tie-down stiffness during tests. A correlation method is required to systematically and consistently account for the stiffness differences and correct the measured results. Direct application of the measured load tends to be conservative and lead to over-design that can reflect on the overall cost and schedule of the project. The objective here is to employ the established correlation method to provide proper high-frequency responses to topsides and hull design teams. In addition, guidance for optimizing tie-down design to avoid damage to the installed equipment, facilities and structural members can be provided.