• Title/Summary/Keyword: Storage facilities

Search Result 823, Processing Time 0.023 seconds

Current treatment and disposal practices for medical wastes in Bujumbura, Burundi

  • Niyongabo, Edouard;Jang, Yong-Chul;Kang, Daeseok;Sung, Kijune
    • Environmental Engineering Research
    • /
    • v.24 no.2
    • /
    • pp.211-219
    • /
    • 2019
  • Since improper management practices of solid medical waste (SMW) could potentially result in serious health risks and environmental problems, it is very important to properly treat and dispose of the medical wastes. In this study, current practices of SMW management from storage to final disposal stage in 12 health care facilities (HCFs) of Burundi were investigated using the official government reports. The results showed that 75% and 92% of HCFs used uncovered wheelbarrows and trucks for on-site or off-site SMW transportation, respectively, indicating that most transportation equipment and waste workers are not safely protected. The results also showed that 92.8% of SMW (15,736.4 ton) from all 12 HCFs were inappropriately disposed of through uncontrolled land disposal and incineration. If pharmaceutical wastes and discarded medical plastics (29.5% of SMW) can be separated and treated properly, the treatment costs can be reduced and resource savings can be achieved. Raising awareness of healthcare workers and general public about potential health effects arising from improper SMW management, sufficient financial and human resources for the treatment facilities (especially incinerators), and effective regulations and guidelines for transportation and treatment of SWM are some of the major tasks for safe and sustainable medical waste management in Burundi.

Reproduction strategy of radiation data with compensation of data loss using a deep learning technique

  • Cho, Woosung;Kim, Hyeonmin;Kim, Duckhyun;Kim, SongHyun;Kwon, Inyong
    • Nuclear Engineering and Technology
    • /
    • v.53 no.7
    • /
    • pp.2229-2236
    • /
    • 2021
  • In nuclear-related facilities, such as nuclear power plants, research reactors, accelerators, and nuclear waste storage sites, radiation detection, and mapping are required to prevent radiation overexposure. Sensor network systems consisting of radiation sensor interfaces and wxireless communication units have become promising tools that can be used for data collection of radiation detection that can in turn be used to draw a radiation map. During data collection, malfunctions in some of the sensors can occasionally occur due to radiation effects, physical damage, network defects, sensor loss, or other reasons. This paper proposes a reproduction strategy for radiation maps using a U-net model to compensate for the loss of radiation detection data. To perform machine learning and verification, 1,561 simulations and 417 measured data of a sensor network were performed. The reproduction results show an accuracy of over 90%. The proposed strategy can offer an effective method that can be used to resolve the data loss problem for conventional sensor network systems and will specifically contribute to making initial responses with preserved data and without the high cost of radiation leak accidents at nuclear facilities.

A Comparative Study on Post-Occupancy-Evaluation (POE) of Apartment and Officetel Based on Habitability Indicators (거주성지표에 따른 아파트와 오피스텔 거주자의 거주후 평가 비교연구)

  • Jung, Seung-Woo;Park, Ji-Yeon;Kang, Bu-Sung
    • Journal of the Korean housing association
    • /
    • v.24 no.2
    • /
    • pp.53-60
    • /
    • 2013
  • Recently, in Korea, single- or two-person households (50.5%) are becoming the primary family type due to increasing divorce rates, population aging, personal code of values and so on. Hence, small families will lead to a sudden increase of single- or two-person households. People searching for small houses are increasing because of the provision of officetels, one room and urban-life housing as well as economic recession. However, this has led to habitability problems, such as parking, storage space and decline in safety. In this study, we obtain the proper contents from LQI indicators of advanced research and use the indicators to evaluate the residential environment quality. We conduct a post-occupancy-evaluation (POE) survey and compare the habitability satisfaction level of apartment and officetel residents. According to the survey, officetel residents' satisfaction levels are low for the following factors in the order listed: ventilation, storage space, management expenses and facilities for children and the elderly.

Design Improvement for the Cooling System of the Interim Spent Fuel Storage Facility Using a PSA Method

  • Ko, Won-Il;Park, Jong-Won;Park, Seong-Won;Lee, Jae-Sol;Park, Hyun-Soo
    • Nuclear Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.440-451
    • /
    • 1996
  • With emphasis on safety, this study addresses for better design condition for the cooling system in a wet-type interim spent fuel storage facility, using a probabilistic safety assessment method. To incorporate the design renovation into the design phase, a simple approach is proposed. By taking the cooling system of a reference design, a fault tree analysis was performed to identify the weak point of the considered system, and then basic factors for design renovation were defined. A total of 21 design alternatives were selected through the combination of the basic factors. Finally, the optimum design alternative for the cooling system is derived by means of the cost and effect analysis based on the estimated cost, system reliability and assumed probabilistic safety criteria. With the assumption that the failure frequency of at-reactor spent fuel cooling system compiles with probabilistic safety criteria for the interim spent fuel cooling system, it was shown that the optimum alternative should have l00% cooling loop redundancy with one pump per cooling loop and a cleanup system installed separately from the main loop. Furthermore, it also should be classified into safety system. The result of this study can be used as a useful basis to identify factors of safety concern and to establish design requirements in the future. The method also can be applied for other nuclear facilities.

  • PDF

Perceived Performance of Sanitary Management of School Food Service Managers in the Seoul Area (서울지역 초등학교 급식관리 영양사의 위생관리와 관련된 직무 수행도)

  • 정유경;곽동경
    • Korean Journal of Community Nutrition
    • /
    • v.5 no.1
    • /
    • pp.100-108
    • /
    • 2000
  • Seven constructs of sanitary management :time temperature, storage, cross-contamination, personal hygiene, equipment facility and documentation management were evaluated to investigate the perceived performance of sanitary management for school food service managers, Using a four-part questionnaire containing the seven constructs of sanitary management HACCP program, demographic information and characteristics of food service facilities participants rated their self-perceptions regarding sanitary management. Of the 550 possible respondents, 248(45.1%) completed the study. For the perceived sanitary manage-ment variables, the participants rated them between 2.66 and 4.16(5-point Likert scale). Temperature management presented the lowest performances while storage management showed the highest. The number of years of work experience of the food service managers and the serving location correlated significantly to sanitary management variables. Documentation management was also highly correlated to the other sanitary management constructs. The respondents ranked the managers leadership and professional knowledge regrading HACCP as most important, followed by the facilitys supporting equipment and human resources second, to successfully implement the HACCP system at the school food service facilites, Awareness of this study indicating low performance on temperature management suggests an active training program is needed for sanitary management of school food service.

  • PDF

Technical Criterion of Safety Evaluation of Leakage Preventing Plates for Alleviating Space Shortage Between Chemical Storage Tank and Dike (화학물질 저장 탱크와 방류벽 사이의 공간 부족 개선을 위한 누출 방지판의 안정성 평가 기준)

  • Lee, Eunbyul;Kwak, Sollim;Choi, Youngbo
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.42-50
    • /
    • 2018
  • The Chemical Controls Act strictly regulates for the chemical companies to establish sufficient space between the liquid chemical tank and dike, but facilities already installed suffer from the space shortage between the tank and dike. Installing leakage preventing plates on the dike is considered as one of the economic solutions that can alleviate the space deficiency. However, there is no technical and reasonable criterion for the safety evaluation of the leakage preventing plate on the dike. In order to address this problem, we provide generalized and verified calculating equations that give maximum height and horizontal distance of leakage trajectories. Through the proposed equations, proper heights of the leakage preventing plates on the dike can be easily determined. In this study, new calculating methods are also developed to determine the impact force of the liquid to the leakage preventing plates. In addition, we performed the reactivity experiments between four corrosive liquid chemicals and two stainless steel materials that are candidate substances for the construction of the leakage preventing plate. The results of this study is expected to be applicable as a guideline in the design of safe dike and its leakage preventing plates.

The Characteristics of Asymmetric Hybrid Supercapacitor Cells and Modules for Power Quality Stabilization (전력품질 안정화용 비대칭 하이브리드 슈퍼커패시터 셀 및 모듈 특성)

  • Lee, Byung-Gwan;Maeng, Ju-Cheul;Lee, Joung-Kyu;Yoon, Jung-Rag
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.4
    • /
    • pp.617-621
    • /
    • 2016
  • In addition to the energy storage facilities based on high power technologies, Electric double layer capacitors(EDLC) are today's candidate for power quality stabilization. However, its low energy density is often inhibiting factor for application of electric power industry. Hybrid supercapacitor is an promising energy storage device that positioned between conventional EDLC and Li-ion battery. This paper describes the preparation and characteristics of a hybrid supercapacitor and module for power quality stabilization. A cylindrical 3200F hybrid supercapacitor ($60{\times}74.5mm$) was assembled by using the $Li_4Ti_5O_{12}$ electrode as an anode and activated carbon as a cathode. It shows 2.5 times higher energy density than conventional EDLC with the same volume. In order to determine the characteristics of the hybrid supercapacitor Module for uninterruptible power supply (UPS), hybrid supercapacitor cells were connected in series with active balancing circuit. At even the high current density of 14A(10C), Module prepared by 18 cells showed the capacitance of 170F at 30~50V, suggesting the applicability for UPS.

Elucidation of Intergranular Corrosion of UNS N08810 alloys (UNS N08810 합금의 입계부식손상과 원인 분석)

  • Kim, Youngsik;Hwangbo, Deok
    • Corrosion Science and Technology
    • /
    • v.11 no.5
    • /
    • pp.196-204
    • /
    • 2012
  • Corrosion failure of petrochemical facilities is one of the difficulties in maintenance, since operating conditions of crude oil production, storage, and refinement are very aggressive. UNS N08810, which has been used for crude oil transportation pipes and storage tanks in petrochemical industries, shows good resistance to general corrosion and localized corrosion in several environments. Among its environments, UNS N08810 showed better corrosion resistance in fuel gas containing sulfuric acid and phosphoric acid and sulfur. However, ductility and toughness at high temperature over about $500^{\circ}C$ were greatly reduced due to microstructural change. In general, welding process is the representative method to join the parts in industrial components. Because the alloy by welding can be sensitized and corroded, the manufacturing process should be controlled. In this work, UNS N08810 was used and heat treatment conditions including solution and stabilization treatments were controlled. Oxalic acid etch test by ASTM A262 Practice A was done to evaluate the qualitative sensitization in room temperature. Huey test by ASTM A262 Practice C was done to evaluate the intergranular corrosion rate in boiling 65% $HNO_3$ solution. Also, the microstructure by thermal history was analyzed. Experimental alloy showed high intergranular corrosion rate and its corrosion mechanism was elucidated.

A Study on the Estimation of REC Multiplier for ESS Introduction (ESS 부가 설치형 REC 가중치 산정에 관한 연구)

  • Kim, Kang-Won;Kim, Balho H.
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.106-111
    • /
    • 2014
  • In order to manage the gradual increase of electricity demand, the United States, Japan, and Europe are seeking to achieve overall change of electric power system by introducing solutions such as smart grid. Among these solutions, there are various research projects regarding the Electricity Storage System (ESS), which aims to promote the efficient usage of electricity and grid system of new and renewable energy system. Korean government revised the law by including ESS in new and renewable energy facilities to accelerate ESS deployment. Following the same direction of the government policy, this study suggests methodologies of setting REC weighted value that guarantees investment financial feasibility when new and renewable power producers install ESS.

Implementation of Video Surveillance System with Motion Detection based on Network Camera Facilities (움직임 감지를 이용한 네트워크 카메라 기반 영상보안 시스템 구현)

  • Lee, Kyu-Woong
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.1
    • /
    • pp.169-177
    • /
    • 2014
  • It is essential to support the image and video analysis technology such as motion detection since the DVR and NVR storage were adopted in the real time visual surveillance system. Especially the network camera would be popular as a video input device. The traditional CCTV that supports analog video data get be replaced by the network camera. In this paper, we present the design and implementation of video surveillance system that provides the real time motion detection by the video storage server. The mobile application also has been implemented in order to provides the retrieval functionality of image analysis results. We develop the video analysis server with open source library OpenCV and implement the daemon process for video input processing and real-time image analysis in our video surveillance system.