• Title/Summary/Keyword: Storage facilities

Search Result 823, Processing Time 0.025 seconds

Development of a Tool for Predicting the Occurrence Time of BLEVE in Small LPG Storage Tanks (LPG소형저장탱크 BLEVE 발생 시점 예측 툴 개발)

  • Chae, Chung Keun;Lee, Jae Hun;Chae, Seung Been;Kim, Yong Gyu;Han, Shin Tak
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.4
    • /
    • pp.74-83
    • /
    • 2020
  • In Korea, about 110,000 LPG small storage tanks of less than three tons have been installed in restaurants, houses and factories, and are used as LPG supply facilities for cooking, heating and industrial use. In the case of combustible liquefied gas storage tanks, the tank may rupture due to the temperature increase of the tank steel plate (approximately 600℃) even when the safety valve is operating normally, causing large-scale damage in an instant. Therefore, in the event of a fire near the LPG small storage tank, it is necessary to accurately predict the timing of the BLEVE(Boiling Liquid Expanding Vapour Explosion) outbreak in order to secure golden time for lifesaving and safely carry out fire extinguishing activities. In this study, we have first investigated the results of a prior study on the prediction of the occurrence of BLEVE in the horizontal tanks. And we have developed thermodynamic models and simulation program on the prediction of BLEVE that can be applied to vertical tanks used in Korea, have studied the effects of the safety valve's ability to vent, heat flux strength of external fires, size of tanks, and gas remaining in tanks on the time of BLEVE occurrence and have suggested future utilization measures.

The Experimental Study of Ice Thermal Storage for Falling Film Type - Sprint Coil Type - (스파이럴형 냉동코일을 사용한 유하액막식 빙축열조에서 열전달현상에 관한 실험적연구)

  • Lee, C.M.;Kim, D.H.;Cho, N.C.;Kim, I.G.;Park, S.R.;Choi, K.K.;Yim, C.S.
    • Solar Energy
    • /
    • v.19 no.2
    • /
    • pp.1-8
    • /
    • 1999
  • The heat transfer characteristics of ice storage system of falling film type using sprial coil is investigated. The experimental facilities consisted of a water tank, spiral coils located above the tank, an upper water distributor, and a circulating water pump. Water is distributed uniformally over the spiral coils and it forms falling thin films. In the process of freezing, ice is formed on outside of the spiral coils through recirculation of tank water. In the process of melting, ice is melted with return water from the heat load, while the water is chilled again and drops into the tank. The results of falling film type of ice thermal storage system are as follows. The highly efficient shower flowrates for icing is near $3{\ell}/min$. Icing rates on spiral coils is rosed while brine flowrates is increased. Lower brine temperature is not only increased freezing rates but. also become higher total icing weight and overall heat transfer coefficient. Smaller shower flowrates is obtained lower water temperature on outlet for a long time. The amounts of quantity can be detected more accurately by measuring storage tank weight.

  • PDF

A Development of Educational Program for Evaluating the Efficiency of Warehouse System (창고 시스템의 효율성 평가를 위한 교육용 프로그램 개발)

  • Kim, Moon-Ki;Kim, Hee-Sung
    • The Journal of Korean Institute for Practical Engineering Education
    • /
    • v.4 no.1
    • /
    • pp.80-85
    • /
    • 2012
  • The importance of warehouse is increasing since the role of warehouse in modern industry is changing from concept of storage to concept of circulation which facilitates purchasing, production, storage and distribution activities by induction of information system. In this study, a program is developed using C# for evaluating efficiency of automated storage and retrieval system(AS/RS). A simulation work is done for eight operating schemes under the combination of three conditions, which are storing method, the shape of automatic warehouse and the sequence of command performs, and the moving distance of stacker crane is calculated using the same gateway data. Using this program, the optimal operating scheme can be proposed based on the analyzed results of simulation. This progrm shows the effectiveness and applicability through the simulation work and can be utilized for courses which are related to factory facilities.

  • PDF

State-of-the-Art of the Ni-bearing Ferritic Steels for LNG Storage Facilities (액화천연가스 저장용 폐라이트계 Ni 첨가강의 물성 및 개발 동향)

  • Han Seung Zeon;Kim Hyoung-Sik;Hong Seong-Ho;Kim Sung-Joon
    • Journal of the Korean Institute of Gas
    • /
    • v.2 no.3
    • /
    • pp.78-87
    • /
    • 1998
  • The mechanical properties, heat treatment and the history for the development of Ni-bearing ferritic steels for the application at low temperatures are reviewed. Ni-bearing ferritic steels are classified into $2-3\%$ Ni steels, $5.5\%$ Ni steel, $9\%$ Ni steel and $13\%$ Ni steel., of which $9\%$ Ni steels are most widely used for the large LNG storage tanks owing to their encellent fracture toughness up to $-196^{\circ}C$. The effect of retained austenite on the tensile properties and toughness was precisely discussed. As the size of LNG storage tank increases, thicker plates are needed. Thus, the recent efforts for the improvement of low temperature toughness and homogeneity are also introduced.

  • PDF

Evaluation of Rainwater Utilization for Miscellaneous Water Demands in Different Types of Buildings Using Geographic Information System

  • Kim, Jinyoung;An, Kyoungjin;Furumai, Hiroaki
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • This study is an attempt to quantify rainwater utilization and miscellaneous water demand in Tokyo's 23 special wards, the core of the urban area in Tokyo, Japan, in order to elucidate the potential of further rainwater utilization. The rainwater utilization for miscellaneous appropriate water demands, including toilet flushing, air conditioning, and garden irrigation, were calculated for six different types of building: residential house, office, department store, supermarket, restaurant, and accommodation. Miscellaneous water demands in these different types of building were expressed in terms of equivalent rainfall of 767, 1,133, 3,318, 1,887, 16,574, and 2,227 (mm/yr), respectively, compared with 1,528 mm of Tokyo's average annual precipitation. Building types, numbers and its height were considered in this study area using geographic information system data to quantify miscellaneous water demands and the amount of rainwater utilization in each ward. Area precipitation-demand ratio was used to measure rainwater utilization potential for miscellaneous water demands. Office and commercial areas, such as Chiyoda ward, showed rainwater utilization potentials of <0.3, which was relatively low compared to those wards where many residential houses are located. This is attributed to the relatively high miscellaneous water demand. In light of rainwater utilization based on building level, the introduction of rainwater storage mechanisms with a storage depth of 50 mm for six different types of buildings was considered, and calculated as rainfall of 573, 679, 819, 766, 930, and 787 (mm), respectively. Total rainwater utilization using such storage facilities in each building from 23 wards resulted in the retention of 102,760,000 $m^3$ of water for use in miscellaneous applications annually, and this volume corresponded to 26.3% of annual miscellaneous water demand.

Development of a Computer Program for the Analysis Logistics of PWR Spent Fuels (PWR 사용후핵연료 운반 물량 분석 프로그램 개발)

  • Choi, Heui-Joo;Cha, Jeong-Hun;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.2
    • /
    • pp.147-154
    • /
    • 2008
  • It is expected that the temporary storage facilities at the nuclear power plants will be full of the spent fuels within 10 years. Provided that a centralized interim storage facility is constructed along the coast of the Korean peninsula to solve this problem, a substantial amount of spent fuels should be transported by sea or by land every year. In this paper we developed a computer program for the analysis of transportation logistics of the spent fuels from 4 different nuclear power plant sites to the hypothetical centralized interim storage facility and the final repository. Mass balance equations were used to analyze the logistics between the nuclear power plants and the interim storage facility. To this end a computer program, CASK, was developed by using the VISUAL BASIC language. The annual transportation rates of spent fuels from the four nuclear power plant sites were determined by using the CASK program. The parameter study with the program illustrated the easiness of logistics analysis. The program could be used for the cost analysis of the spent fuel transportation as well.

  • PDF

Identification of Free-Living Amoebas in Tap Water of Buildings with Storage Tanks in Korea

  • Lee, Da-In;Park, Sung Hee;Baek, Jong Hwan;Yoon, Jee Won;Jin, Soo Im;Han, Kwang Eon;Yu, Hak Sun
    • Parasites, Hosts and Diseases
    • /
    • v.58 no.2
    • /
    • pp.191-194
    • /
    • 2020
  • Free-living amoebas (FLAs) can cause severe disease in humans and animals when they become infected. However, there are no accurate survey reports on the prevalence of FLAs in Korea. In this study, we collected 163 tap water samples from buildings, apartments, and restrooms of highway service areas in 7 Korean provinces with high population density. All these buildings and facilities have water storage tanks in common. The survey was separated into categories of buildings, apartments, and highway service areas. Five hundred milliliters of tap water from each building was collected and filtered with 0.2 ㎛ pore filter paper. The filters were incubated in agar plates with heated E. coli at 25℃. After axenization, genomic DNA was collected from each FLA, and species classification was performed using partial 18S-rDNA PCR-sequencing analysis. We found that 12.9% of tap water from buildings with storage tanks in Korea was contaminated with FLAs. The highway service areas had the highest contamination rate at 33.3%. All of the FLAs, except one, were genetically similar to Vermamoeba vermiformis (Hartmannella vermiformis). The remaining FLA (KFA21) was very similar to Acanthamoeba lugdunensis (KA/E26). Although cases of human infection by V. vermiformis are very rare, we must pay attention to the fact that one-third of tap water supplies in highway service areas have been contaminated.

A Study on the Analysis and Protection of Lightning Accident in Petrochemical Plant Wastewater Storage Tank (석유화학공장 폐수 저장 탱크의 낙뢰사고 분석과 보호방안에 관한 연구)

  • Song, Bang-Un;Oh, Gil-Jung;Woo, In-Sung
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.107-113
    • /
    • 2019
  • Recently, due to global warming, the trend shows an increase in number of lightning strikes which increase risk regarding industry infrastructures. Especially in case where the lightning strikes infrastructures including refinery, petorchemical plant facilities or storage tanks, it can cause power failures, electrical machine malfunction and damage which can lead to fire explosion and multiple calamities. Therefore, detailed case studies must be conducted through a systematic research regarding lightning strike accidents in order to understand its mechanism and devise preventive measures. This paper aims to study cases of explosion regarding waste water storage tanks in refineries and petrochemical plants in order to analyze its root cause and provide preventive measures for avoiding lightning related incidents.

Effect of Different Irrigation Levels on the Fiber Content of Sweetpotato Root

  • Won Park;Hyeong-Un Lee;Tae Hwa Kim;Kyo Hwui Lee;Sang Sik Nam;Mi Nam Chung
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.49-49
    • /
    • 2022
  • One of the major problems with sweetpotato (Ipomoea batats Lam.) is the tough thread tissue that occurs in the storage root, which has a negative impact on the sales of sweet potato because it impairs the texture during cooking and the processing quality. The fiber contents in storage roots of sweetpotato is affected by cultivation conditions and environment. To investigate the effect of fiber generation at different levels of irrigation, the sweetpoatoto "Hogammi" was transplanted in greenhouse. Sweetpotato was grown in styrofoam beds(W1605*D330*H300mm) to block moisture flowing from the outside. The irrigation was carried out as 3 levels (5,10, and 20 mm through drip irrigation facilities) at 20-day intervals. Five plants were harvested per plot at 90, 100 and 120 days after transplanting (DAT). The size of the storage root was large in the order of irrigation conditions 10mm>20mm>5mm treatment. And the longer cultivation period, the larger size of the storage root was observed. As a result of the analysis of the fiber content, it showed a tendency to decrease as the cultivation period increased (90days→120days). In addition, the fiber contents of sweetpotato harvested at 90, 100 and 120 DAT in the level of 5 mm irrigation plot were 351, 324 and 207 mg/100g, respectively, which were higher than those of other irrigation level plots. During all cultivation periods, the 10mm treatment group showed the lowest fiber content of 280, 228 and 127 mg/100g. At 20 mm irrigation level, the fiber content was less than that of 5mm irrigation level, but showed a tendency to increase compared to that of 10 mm irrigation level. These results suggested that drought stress or excessive-irrigation increases the fiber content of sweetpotato, which reduces their commercial value.

  • PDF

Analysis of Perception of School Foodservice Facilities and Utilities in Gyeongnam Area by School Nutrition Teachers (Dietitians) -Comparison of School Foodservice Facilities and Improvement of Utilities in Schools- (경남지역 영양(교)사의 급식시설 설비에 대한 인지도 분석 -학교급식시설 현대화 사업 완료 학교와 미완료 학교의 비교를 중심으로-)

  • Jeon, Young;Kim, Hyun-Ah
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.9
    • /
    • pp.1447-1456
    • /
    • 2014
  • The purpose of this study was to compare perception of school foodservice facilities and utilities in dietitians and school nutrition teachers in the Gyeongnam area between schools that improved foodservice facilities and utilities versus those who did not. From July 23 to Aug 31, 2012, 391 questionnaires were distributed, and 289 questionnaires were obtained. A total of 275 questionnaires were used for the final analysis, excluding improper ones. The results of this study were as follows. First, among 275 schools, 90 schools (32.7%) improved school foodservice facilities and utilities while 175 schools (67.3%) did not. Second, schools with improved facilities had a more well-equipped receiving room (P<0.01), preparation room (P<0.001), dishwashing room (P<0.001), storage room for supplies (P<0.001), rest-room for school foodservice employees (P<0.05), locker room (P<0.01), shower room (P<0.001), laundry room (P<0.001), boiler room (P<0.05), and room for serving cart (P<0.05) than schools with no improvement. Third, total perception score of school foodservice facilities area from schools with improved facilities (1.71) was significantly higher than that (1.60) of school without improvement (P<0.001). Fourth, total satisfaction (3.32) of school foodservice facilities and utilities in school with improved facilities was significantly higher than that (2.62) of schools without improvement (P<0.01). Fifth, schools with improved facilities had a better equipped of floor (P<0.05), entrance (P<0.001), drain (P<0.001), water supply (P<0.01), lighting (P<0.001), hand washing (P<0.001), foodservice management room (P<0.001), locker room (P<0.001), rest-room and shower room (P<0.001), and preparation room (P<0.001) than schools without improvement. However, there was no significant difference in terms of walls and ceilings, windows, ventilation, and storage. In conclusion, school foodservice facilities and utilities improvement should conducted as soon as possible.