• Title/Summary/Keyword: Storage coefficient

Search Result 470, Processing Time 0.034 seconds

Assessment of Effects of Groundwater Pumping from Deep Aquifer on Streamflow Depletion (죽산천 주변 암반층 지하수 양수로 인한 하천수 감소 영향 분석)

  • Lee, Jeongwoo;Kim, Nam Won;Chung, Il Moon;Cha, Joon Ho
    • Journal of Korea Water Resources Association
    • /
    • v.48 no.9
    • /
    • pp.769-779
    • /
    • 2015
  • The streamflow depletion due to groundwater pumping from deep aquifer near the Juksan stream has been simulated, in this study, by using the surface water and groundwater integrated model, SWAT-ODFLOW in order to analyze the relationship between the stream depletion and hydraulic properties of aquifer and streambed, and to spatially assess the streamflow depletion. The simulated results showed that the streamflow depletion rate divided by the pumping rate for each well location ranges from 10% to 90% with reflecting the various well-stream distance, transmissivity, storativity, and streambed hydraulic conductance. In particular, the streamflow depletion exceeds about 50% of pumping rate for conditions with transmissivity higher than $10m^2/day$ or storage coefficient lower than 0.1. The simulated results in the form of spatial maps indicated that the spatially averaged percent depletion of streamflow is about 53.6% for five years of pumping which is lower than that for shallow aquifer pumping by 12.9%. From the spatially distributed stream depletion, it was found that higher and more rapid stream depletion to pumping occurs near middle-downstream reach.

Method Development for the Profiling Analysis of Urine Globotriaosylceramide (Gb3) for the Screening of Fabry Disease by Tandem Mass Spectrometry (ESI-MS/MS를 이용한 소변 중 Globotriaosylceramide(Gb3)의 정량 및 임상 응용; 패브리병(Fabry) 진단)

  • Yoon, Hye-Ran;Cho, Kyung-Hee;Kang, Seung-Woo;Kwon, Young-Joo;Jeong, Choon-Sik;Lee, Yong-Soo
    • YAKHAK HOEJI
    • /
    • v.51 no.2
    • /
    • pp.96-102
    • /
    • 2007
  • Measurement of globotriaosylceramide (Gb3, ceramide trihexoside) in urine has clinical importance for monitoring after enzyme replacement therapy in Fabry disease patients. The disease is an X-linked lipid storage disorder that results from a deficiency of the enzyme ${\alpha}$-galactosidase A (${\alpha}$-Gal A). The lack of ${\alpha}$-Gal A causes an intracellular accumulation of glycosphingolipids, mainly Gb3. A simple, rapid, and highly sensitive analytical method for Gb3 in urine was developed without labor-extensive pre-treatment by electrospray ionization MS/MS (ESI-MS/MS). Only simple 5-fold dilution of urine is necessary for the extraction and isolation of Gb3 in urine. Gb3 in diluted urine was dissolved in dioxane containing C17:0 Gb3 as an internal standard. After centrifugation it was directly injected and analyzed through guard column by in combination with multiple reaction monitoring mode of ESI-MS/MS. Eight isoforms of Gb3 were completely resolved from urine matrix. C24:0 Gb3 occupied 50% of total Gb3 as a major component in urine. Linear relationship for Gb3 isoforms was found in the range of 0.005${\sim}$5.0 ${\mu}$g/ml. The limit of detection (S/N=5) was 0.005 ${\mu}$g/ml and limit of quantification was 0.05 ${\mu}$g/ml for C24:0 Gb3 with acceptable precision and accuracy. Correlation coefficient of calibration curves for 8 Gb3 isoforms ranged from 0.9598 to 0.9975. This method could be useful for rapid and sensitive 1st line Fabry disease screening, monitoring and/or diagnostic tool for Fabry disease.

Groundwater evaluation in the Bokha watershed of the Namhan River using SWAT-MODFLOW (SWAT-MODFLOW를 활용한 남한강 복하천유역의 지하수 모의 평가)

  • Han, Daeyoung;Lee, Jiwan;Jang, Wonjin;Kim, Seongjoon
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.11
    • /
    • pp.985-997
    • /
    • 2020
  • SWAT (Soil and Water Assessment Tool)-MODFLOW (Modular Groundwater Flow) is a coupled model that linking semi-distributed watershed hydrology with fully-distributed groundwater behavior. In this study, the groundwater simulation results of SWAT and SWAT-MODFLOW were compared for Bokhacheon watershed in Namhan river basin. The models were calibrated and validated with 9 years (2009~2017) daily streamflow (Q) data of Heungcheon (HC) water level gauge station and the daily groundwater level observation data of Yulheon (YH). For SWAT, the groundwater parameters of GW_DELAY, GWQMN, and ALPHA_BF affecting baseflow and recession phase were treated. The SWAT results showed the coefficient of determination (R2) of 0.7 and Nash-Sutcliffe model efficiencies (NESQ, NSEinQ) for Q and 1/Q with 0.73 and -0.1 respectively. For SWAT-MODFLOW, the spatio-temporal aquifer hydraulic conductivity (K, m/day), specific storage (Ss, 1/m), and specific yield (Sy) were applied. The SWAT-MODFLOW showed R2, NSEQ, and NSEinQ of 0.69, 0.74, and 0.51 respectively. The SWAT-MODFLOW considerably enhanced the low flow simulation with the help of aquifer physical information. The total streamflow of SWAT and SWAT-MODFLOW were 718.6 mm and 854.9 mm occupying baseflow of 342.9 mm and 423.5 mm respectively.

Development of a shot noise process based rainfall-runoff model for urban flood warning system (도시홍수예경보를 위한 shot noise process 기반 강우-유출 모형 개발)

  • Kang, Minseok;Yoo, Chulsang
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.1
    • /
    • pp.19-33
    • /
    • 2018
  • This study proposed a rainfall-runoff model for the purpose of real-time flood warning in urban basins. The proposed model was based on the shot noise process, which is expressed as a sum of shot noises determined independently with the peak value, decay parameter and time delay of each sub-basin. The proposed model was different from other rainfall-runoff models from the point that the runoff from each sub-basin reaches the basin outlet independently. The model parameters can be easily determined by the empirical formulas for the concentration time and storage coefficient of a basin and those of the pipe flow. The proposed model was applied to the total of three rainfall events observed at the Jungdong, Guro 1 and Daerim 2 pumping stations to evaluate its applicability. Summarizing the results is as follows. (1) The unit response function of the proposed model, different from other rainfall-runoff models, has the same shape regardless of the rainfall duration. (2) The proposed model shows a convergent shape as the calculation time interval becomes smaller. As the proposed model was proposed to be applied to urban basins, one-minute of calculation time interval would be most appropriate. (3) Application of the one-minute unit response function to the observed rainfall events showed that the simulated runoff hydrographs were very similar to those observed. This result indicates that the proposed model has a good application potential for the rainfall-runoff analysis in urban basins.

Assessment of future climate change impact on groundwater level behavior in Geum river basin using SWAT (SWAT을 이용한 미래기후변화에 따른 금강유역의 지하수위 거동 평가)

  • Lee, Ji Wan;Jung, Chung Gil;Kim, Da Rae;Kim, Seong Joon
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.3
    • /
    • pp.247-261
    • /
    • 2018
  • The purpose of this study is to evaluate the groundwater level behavior of Geum river basin ($9,645.5km^2$) under future climate change scenario projection periods (2020s: 2010~2039, 2050s: 2040~2069, 2080s: 2070~2099) using SWAT (Soil and Water Assessment Tool). Before future evaluation, the SWAT was calibrated and validated using 11 years (2005~2015) daily multi-purpose dam inflow at 2 locations (DCD, YDD), ground water level data at 5 locations (JSJS, OCCS, BEMR, CASS, BYBY), and three years (2012~2015) daily multi-function weir inflow at 3 locations (SJW, GJW, BJW). For the two dam inflow and dam storage, the Nash-Sutcliffe efficiency (NSE) was 0.57~0.67 and 0.87~0.94, and the coefficient of determination ($R^2$) was 0.69~0.73 and 0.63~0.73 respectively. For the three weir inflow and storage, the NSE was 0.68~0.70 and 0.94~0.99, and the $R^2$ was 0.83~0.86 and 0.48~0.61 respectively. The average $R^2$ for groundwater level was from 0.53 to 0.61. Under the future temperature increase of $4.3^{\circ}C$ and precipitation increase of 6.9% in 2080s (2070~2099) based on the historical periods (1976~2005) from HadGEM3-RA RCP 8.5 scenario, the future groundwater level shows decrease of -13.0 cm, -5.0 cm, -9.0 cm at 3 upstream locations (JSJS, OCCS, BEMR) and increase of +3.0 cm, +1.0 cm at 2 downstream locations (CASS, BYBY) respectively. The future groundwater level was directly affected by the groundwater recharge by the future seasonal spatial variation of rainfall in the watershed.

Effect of Heat Treatment Conditions on the Characteristics of Gel Made from Arrowroot Starch in Korea Cultivars (국내산 칡 전분 젤 특성에 미치는 가열처리 조건의 영향)

  • Lee, Seog-Won;Kim, Hyo-Won;Han, Sung-Hee;Rhee, Chul
    • The Korean Journal of Food And Nutrition
    • /
    • v.22 no.3
    • /
    • pp.387-395
    • /
    • 2009
  • This study was conducted to investigate the effects of starch concentrations and heating conditions on the gel characteristics of arrowroot starch. Arrowroot starch gels with various pHs, and starch concentrations, were prepared using different temperatures and heating times, and then stored for 24 hrs at $4^{\circ}C$. The hardness of sample gels made at pH 2.0 and 4.0 increased as the starch concentration increased from 7% to 10%, with the maximum value of 94 N being obtained when the gel was prepared at pH 4.0 with a starch concentration of 10%. The maximum hardness of samples prepared with concentrations of starch ranging from 7~9% appeared at $80^{\circ}C$, regardless of the heating temperature and time. Furthermore, the hardness of samples prepared at greater than $100^{\circ}C$ was relatively lower than that of samples prepared at other temperatures. When a starch concentration of 8% was used, the degree of gelatinization(DR) increased as the heating temperature increased, with the maximum value of DR being about 76% at $120^{\circ}C$, regardless of heating time. After storage for 24 hrs, the hardness of samples prepared at $70^{\circ}C$, $80^{\circ}C$ and $90^{\circ}C$ appeared to decrease, while that of samples prepared at $100^{\circ}C$, $110^{\circ}C$ and $120^{\circ}C$ increased. The correlation between hardness and the degree of gelatinization or retrogradation was very high when samples were prepared at $80^{\circ}C$ with a starch concentration of 9%, as indicated by a correlation coefficient of greater than 0.95. Overall, the microstructures of freeze-dried arrowroot starch gel were composed of a continuous network of amylose and amylopectin with fragmented ghost structures in an excluded phase, but these ghost structures were more evident after storage and with increased heating temperature.

Development of Solar Warehouse for Drying and Storing the Agricultural Products (농산물(農産物) 건조(乾燥) 및 저장(貯藏)을 위(爲)한 태양열(太陽熱) 저장고(貯藏庫)의 개발(開發)에 관(關)한 연구(硏究))

  • Kim, Man Soo;Chang, Kyu Seob;Kim, Soung Rai;Jeon, Byeong Seon
    • Korean Journal of Agricultural Science
    • /
    • v.9 no.1
    • /
    • pp.357-370
    • /
    • 1982
  • Recent concern regarding price and availability of fossil fuels has spurred the interest in alternative sources for farm crop drying. Among the available options such as biomass energy, wind power, nuclear energy and solar energy etc., the increasing attention is being directed to the utilization of heat from solar energy especially for farm crop drying. Even though solar energy is dispersed over a large land area and only a relatively small amount of energy can be simply collected, the advantages of solar energy is that the energy is free, non-polluting. The study reported here was designed to help supply the informations for the development of simple and relatively inexpensive solar warehouse for farm crop drying and storage. Specifically, the objectives of this study were to determine the performance of the solar collector fabricated, to compare solar supplemented heat drying with natural air drying and to develop a simulation model of temperature in stored grain, which can be used to study the effects due to changes in ambient air temperature. For those above objectives, solar collector was fabricated from available materials. Corrugated steel galvanized sheet, painted flat black, was used as absorbers and clear 0.2mm polyethylene sheet was the cover material. The warehouse for rough rice drying and storage was constructed with concrete block, and the solar collector was used as the roof of warehouse instead of original roofing system of it. The results obtained in this study were as follows: 1. The thermal efficiency of the solar collector was average 26 percent and the overall heat transfer coefficient of the collector was approximately $25kJ/hr.m^2\;^{\circ}K$. 2. Solar heated air was sufficient to dry one cubic meter of rough rice from 23.5 to 15.0 percent in 7 days and natural air was able to dry the same amount of rough rice from 20.0 to 5 percent in l2 days. 3. Drying with solar heat reduced the required drying time to dry the same amount of rough rice into a half compared to natural air drying, but overdrying problems of the bottom layer were so severe that these problems should be thoroughly analyzed. 4. Simulation model of temperature in stored grain was developed and the results of predicted temperature agreed well with test results. 5. Based on those simulated temperature, changes in the grain-temperature were a large at the points of the wallside and the damage of the grain would be severe at the contact area of wall.

  • PDF

Effect of Hot-water Dipping on Inhibiting Red Discoloration of Basal Part in Chicon (열수 침지 처리가 치콘 절단면의 적변 억제에 미치는 영향)

  • Jung, Hyun Jin;Kang, Ho-Min
    • Horticultural Science & Technology
    • /
    • v.32 no.3
    • /
    • pp.353-358
    • /
    • 2014
  • Hot water dipping test was conducted for chicon to restrict red discoloration of its basal part which impairs the product value during sales. Hot water dipping treatment was given to chicon for 4 min and for 8 min at $38^{\circ}C$ and for 2 min and 4 min at $42^{\circ}C$, and for 1 min and 2 min at $45^{\circ}C$, along with control (for one min at $20^{\circ}C$). The red discoloration indices of basal part of chicon during sensory evaluation on the sixth day of storage under the storage temperature at $10^{\circ}C$ was lower at $42^{\circ}C$ for 2 min, $42^{\circ}C$ for 4 min and $45^{\circ}C$ for 1 min treatments. The color change value of the basal part in chicon measured by colorimeter showed that the lowest ${\Delta}a^*$ and ${\Delta}h$ were maintained in the basal part of chicon treated at $42^{\circ}C$ for 2 min. Whereas, color changes in $42^{\circ}C$ for 2 min and $45^{\circ}C$ for 1 min treatments were significantly low as compared with that of control. The contents of total phenolic compounds which are the substances that cause red discoloration of basal part in chicon were lowest at $42^{\circ}C$ for 2 min, $42^{\circ}C$ for 4 min and $45^{\circ}C$ for 1 min treatments. The activity of phenylalanine ammonia lyase (PAL) resposible for in the synthesis of phenolic substances was the least in $42^{\circ}C$ for 2 min treatment. Whereas, PAL activity of the chicons treated a t $42^{\circ}C$ for 2 min and at $45^{\circ}C$ for 1 min were significantly lower than that of control. However, red discoloration was progressed as similar level with that of control in the basal part of chicon at $45^{\circ}C$ for 2 min. The contents of total phenolic compounds and PAL activity in this treatment were not significantly different from those in control. The polyphenol oxidase (PPO) activity which causes red discoloration of cut tissues was low in all the treatments including $42^{\circ}C$ and $45^{\circ}C$ treatment at which no inhibition effects of the red discoloration of basal part of chicon were observed. When the correlation coefficient between each investigated index was tested, most of them showed high correlation except the PPO activity and particularly and the red discoloration index and sensory evaluation ${\Delta}h$ values, and PAL activity and total phenolic compounds content were $r=0.927^{**}$, and $r=0.942^{**}$, respectively.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

In Vivo Preperation of Standard Reference Materials of Lead in Blood (생체내 혈중 납 표준물질의 제조)

  • Chung, Kyou-Chull;Choi, Ho-Chun
    • Journal of Preventive Medicine and Public Health
    • /
    • v.28 no.4 s.51
    • /
    • pp.863-873
    • /
    • 1995
  • This report describes a preperation and characterization of canine blood lead(Pb) standard reference material(SRM). Three adult beagle dogs(A, B, and C)were orally dosed with gelatin capsules containing $Pb(NO_3)_2$, equivalent to $10\sim80mg$ Pb/kg body weight. Blood was drawn 24 hours after the dose from the cephalic vein into lead free 500ml Pyrex beaker in which EDTA.K was contained as an anticoagulant. The amount of lead given to individual dog was varied arbitrarily. Three month later, 3 canine animals were orally dosed with lead secondarily to make mixed SRM(D1) which was mixed different concentrations of lead in bloods with A1, B1, and C1 in vitro. The SRMs for A, B, C, A1, B1, C1, and D1 were distributed 2ml each into more than 300 lead free bottles, and were stored in refregerator at $4^{\circ}C$. The amount of lead in canine whole blood samples were determined using a Varian 30A atomic absorption spectrophotometer(AAS) with a model GTA-96 graphite tube atomizer with D2 background correction and a Hitachi Z-8100 AAS with Zeeman background correction. The sensitivity and detection limits for lead determination of Varian 30A were $0.46{\mu}g/L,\;0.34{\mu}g/L,\;and\;0.56{\mu}g/L,\;0.14{\mu}g/L$ of Hitachi Z-8100, respectively. Day to day variations in determination of blood lead concentration in a certain sample were $31.11{\pm}1.36{\mu}g/100ml$ by Varian 30A, and $33.08{\pm}0.82{\mu}g/100ml$ by Hitachi Z-8100, showing the difference of 3% between the two results. At the blood lead concentrations of $56.31{\pm}1.98{\mu}g/100ml(A),\;40.89{\pm}0.80{\mu}g/100ml(B),\;59.01{\pm}1.38{\mu}g/100ml(C)$, the precisions of replicated measurements by AAS were 3.52%, 1.96%, and 2.34%, respectively. Coefficient variation(CV) of SRMs(A, B, and C) within a standard sample were ranged from 0.92% to 7.50%, and those between 5 standard samples were 1.21%, 2.64%, and 1.11%, respectively, showing inter-vial variation of $1{\mu}g/100ml$. Lead levels in SRMs during one month storage were unchanged. The overall recoveries were $89.6\sim100.4%,\;91.6\sim101.9%,\;90.3\sim100.0%$ for A, B, and C SRMs, means were $56.46{\pm}2.69{\mu}g/100ml,\;39.35{\pm}1.89{\mu}g/100ml,\;57.40{\pm}2.31{\mu}g/100ml$, and measurement ranges were$52.88{\pm}59.26{\mu}g/100ml,\;37.47{\pm}41.68{\mu}g/100ml,\;54.80{\pm}60.69{\mu}g/100ml$, respectively. Those results were laid within confidence limits values. The lead concentrations in the mixed sample(D1) stored over one month period were ranged from $32.76{\mu}g/100ml\;to\;33.54{\mu}g/100ml$, with CV ranging from 1.2% to 2.7%. The results were similiar to each of single samples(A1, B1, and C1) in respect of homogeneity and stability. Results of the mixed blood sample analysed after 1 month storage at $4^{\circ}C$ by four other laboratories(L1, L2, L3, L4) were similar with those of our laboratory($L5;31.18{\pm}0.24{\mu}g/100ml$, acceptable range by $CDC;25.18\sim37.18{\mu}g/100ml$), showing the concentrations of $25.91{\pm}1.19{\mu}g/100ml(L1),\;34.16{\pm}0.22{\mu}g/100ml(L2),\;35.68{\pm}0.85{\mu}g/100ml(L3),\;30.95{\pm}0.46{\mu}g/100ml(L4)$ in a each samples.

  • PDF