• 제목/요약/키워드: Storage coefficient

검색결과 470건 처리시간 0.026초

유역특성에 의한 합성단위도의 유도에 관한 연구 (Derivation of the Synthetic Unit Hydrograph Based on the Watershed Characteristics)

  • 서승덕
    • 한국농공학회지
    • /
    • 제17권1호
    • /
    • pp.3642-3654
    • /
    • 1975
  • The purpose of this thesis is to derive a unit hydrograph which may be applied to the ungaged watershed area from the relations between directly measurable unitgraph properties such as peak discharge(qp), time to peak discharge (Tp), and lag time (Lg) and watershed characteristics such as river length(L) from the given station to the upstream limits of the watershed area in km, river length from station to centroid of gravity of the watershed area in km (Lca), and main stream slope in meter per km (S). Other procedure based on routing a time-area diagram through catchment storage named Instantaneous Unit Hydrograph(IUH). Dimensionless unitgraph also analysed in brief. The basic data (1969 to 1973) used in these studies are 9 recording level gages and rating curves, 41 rain gages and pluviographs, and 40 observed unitgraphs through the 9 sub watersheds in Nak Oong River basin. The results summarized in these studies are as follows; 1. Time in hour from start of rise to peak rate (Tp) generally occured at the position of 0.3Tb (time base of hydrograph) with some indication of higher values for larger watershed. The base flow is comparelatively higher than the other small watershed area. 2. Te losses from rainfall were divided into initial loss and continuing loss. Initial loss may be defined as that portion of storm rainfall which is intercepted by vegetation, held in deppression storage or infiltrated at a high rate early in the storm and continuing loss is defined as the loss which continues at a constant rate throughout the duration of the storm after the initial loss has been satisfied. Tis continuing loss approximates the nearly constant rate of infiltration (${\Phi}$-index method). The loss rate from this analysis was estimated 50 Per cent to the rainfall excess approximately during the surface runoff occured. 3. Stream slope seems approximate, as is usual, to consider the mainstreamonly, not giving any specific consideration to tributary. It is desirable to develop a single measure of slope that is representative of the who1e stream. The mean slope of channel increment in 1 meter per 200 meters and 1 meter per 1400 meters were defined at Gazang and Jindong respectively. It is considered that the slopes are low slightly in the light of other river studies. Flood concentration rate might slightly be low in the Nak Dong river basin. 4. It found that the watershed lag (Lg, hrs) could be expressed by Lg=0.253 (L.Lca)0.4171 The product L.Lca is a measure of the size and shape of the watershed. For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the watershed characteristics, L and Lca. 5. Expression for basin might be expected to take form containing theslope as {{{{ { L}_{g }=0.545 {( { L. { L}_{ca } } over { SQRT {s} } ) }^{0.346 } }}}} For the logarithms, the correlation coefficient for Lg was 0.97 which defined that Lg is closely related with the basin characteristics too. It should be needed to take care of analysis which relating to the mean slopes 6. Peak discharge per unit area of unitgraph for standard duration tr, ㎥/sec/$\textrm{km}^2$, was given by qp=10-0.52-0.0184Lg with a indication of lower values for watershed contrary to the higher lag time. For the logarithms, the correlation coefficient qp was 0.998 which defined high sign ificance. The peak discharge of the unitgraph for an area could therefore be expected to take the from Qp=qp. A(㎥/sec). 7. Using the unitgraph parameter Lg, the base length of the unitgraph, in days, was adopted as {{{{ {T}_{b } =0.73+2.073( { { L}_{g } } over {24 } )}}}} with high significant correlation coefficient, 0.92. The constant of the above equation are fixed by the procedure used to separate base flow from direct runoff. 8. The width W75 of the unitgraph at discharge equal to 75 per cent of the peak discharge, in hours and the width W50 at discharge equal to 50 Per cent of the peak discharge in hours, can be estimated from {{{{ { W}_{75 }= { 1.61} over { { q}_{b } ^{1.05 } } }}}} and {{{{ { W}_{50 }= { 2.5} over { { q}_{b } ^{1.05 } } }}}} respectively. This provides supplementary guide for sketching the unitgraph. 9. Above equations define the three factors necessary to construct the unitgraph for duration tr. For the duration tR, the lag is LgR=Lg+0.2(tR-tr) and this modified lag, LgRis used in qp and Tb It the tr happens to be equal to or close to tR, further assume qpR=qp. 10. Triangular hydrograph is a dimensionless unitgraph prepared from the 40 unitgraphs. The equation is shown as {{{{ { q}_{p } = { K.A.Q} over { { T}_{p } } }}}} or {{{{ { q}_{p } = { 0.21A.Q} over { { T}_{p } } }}}} The constant 0.21 is defined to Nak Dong River basin. 11. The base length of the time-area diagram for the IUH routing is {{{{C=0.9 {( { L. { L}_{ca } } over { SQRT { s} } ) }^{1/3 } }}}}. Correlation coefficient for C was 0.983 which defined a high significance. The base length of the T-AD was set to equal the time from the midpoint of rain fall excess to the point of contraflexure. The constant K, derived in this studies is K=8.32+0.0213 {{{{ { L} over { SQRT { s} } }}}} with correlation coefficient, 0.964. 12. In the light of the results analysed in these studies, average errors in the peak discharge of the Synthetic unitgraph, Triangular unitgraph, and IUH were estimated as 2.2, 7.7 and 6.4 per cent respectively to the peak of observed average unitgraph. Each ordinate of the Synthetic unitgraph was approached closely to the observed one.

  • PDF

다목적 댐 및 다기능 보 운영을 고려한 대유역 SWAT 모형 구축기법 연구 - 남한강 유역을 대상으로 - (Large Scale SWAT Watershed Modeling Considering Multi-purpose Dams and Multi-function Weirs Operation - For Namhan River Basin -)

  • 안소라;이지완;장선숙;김성준
    • 한국농공학회논문집
    • /
    • 제58권4호
    • /
    • pp.21-35
    • /
    • 2016
  • This study is to evaluate the applicability of SWAT (Soil and Water Assessment Tool) model for multi-purpose dams and multi-function weirs operation in Namhan river basin ($12,577km^2$) of South Korea. The SWAT was calibrated (2005 ~ 2009) and validated (2010 ~ 2014) considering of 4 multi-purpose dams and 3 multi-function weirs using daily observed dam inflow and storage, evapotranspiration, soil moisture, and groundwater level data. Firstly, the dam inflow was calibrated by the five steps; (step 1) the physical rate between total runoff and evapotranspiration was controlled by ESCO, (step 2) the peak runoff was calibrated by CN, OV_N, and CH_N, (step 3) the baseflow was calibrated by GW_DELAY, (step 4) the recession curve of baseflow was calibrated by ALPHA_BF, (step 5) the flux between lateral flow and return flow was controlled by SOL_AWC and SOL_K, and (step 6) the flux between reevaporation and return flow was controlled by REVAPMN and GW_REVAP. Secondly, for the storage water level calibration, the SWAT emergency and principle spillway were applied for water level from design flood level to restricted water level for dam and from maximum to management water level for weir respectively. Finally, the parameters for evapotranspiration (ESCO), soil water (SOL_AWC) and groundwater level fluctuation (GWQMN, ALPHA_BF) were repeatedly adjusted by trial error method. For the dam inflow, the determination coefficient $R^2$ was above 0.80. The average Nash-Sutcliffe efficiency (NSE) was from 0.59 to 0.88 and the RMSE was from 3.3 mm/day to 8.6 mm/day respectively. For the water balance performance, the PBIAS was between 9.4 and 21.4 %. For the dam storage volume, the $R^2$ was above 0.63 and the PBIAS was between 6.3 and 13.5 % respectively. The average $R^2$ for evapotranspiration and soil moisture at CM (Cheongmicheon) site was 0.72 and 0.78, and the average $R^2$ for groundwater level was 0.59 and 0.60 at 2 YP (Yangpyeong) sites.

물류서비스 산업의 국민경제적 파급효과 분석 (A Study on the Ripple Effect of Physical Distribution Service Industry on National Economy)

  • 정분도;홍금우
    • 한국항만경제학회지
    • /
    • 제24권2호
    • /
    • pp.193-208
    • /
    • 2008
  • 본 논문의 연구목적은 산업연관표를 이용하여 물류서비스산업의 국민경제적 파급효과를 분석함으로써 물류서비스부문의 정책개선의 자료로 활용하고자 한다. 분석을 위하여 한국은행에서 작성 발표된 산업연관표를 사용하였는데, 1998년, 2000년, 2003년의 산업연관표를 이용하여 분석하였다. 분석결과를 요약하면, 생산유발계수는 철도운송 1757단위, 도로운송 1688단위, 하역 1617단위로 높게 나타나고, 수입유발계수를 보면, 운수보조서비스, 하역, 보관 및 창고, 기타 운수관련서비스 등은 낮게 나타나는 반면 수상운송 0.679단위, 항공운송 0.558단위로 수입유발계수가 높게 나타나고 있다. 다음으로 부가가치유발계수는, 철도운송 0.841단위, 도로운송 0.828단위, 운수보조서비스 0.962단위, 하역 0.939단위, 보관 및 창고 0.938단위, 기타 운수관련서비스 0.942단위로 부가가치유발계수가 높게 나타나고 있다. 감응도계수는 도로운송이 높고, 수상운송과 보관 및 창고업의 감응도계수가 낮다. 그리고 영향력계수는 철도운송, 도로운송이 높고, 반면에 수상운송과 항공운송의 영향력계수가 낮게 나타났다. 물류서비스산업의 취업구조를 살펴보면, 도로운송부문이 74만 4천명으로 가장 많이 종사하고 있으며, 항공운송 1만 9천명, 운수보조서비스업이 2만명으로 물류서비스업에서 종사자가 가장 적은 것으로 나타났다.

  • PDF

지하공간 환경예측 시뮬레이션 개발 연구-핵 폐기물 저장공간 중심으로 (A study on simulation modeling of the underground space environment-focused on storage space for radioactive wastes)

  • 이창우
    • 터널과지하공간
    • /
    • 제9권4호
    • /
    • pp.306-314
    • /
    • 1999
  • 핵폐기물 저장공간과 같이 대규모 터널형 지하공간내에서의 환기량, 온/습도, 오염물질 농도 예측은 공간건설 및 운영을 위하여서 뿐만 아니라 화재등과 같은 비상시의 대처방안 강구를 위하여 반드시 필요하다. 본 연구에서는 압축성 가정하에서 autocompression의 영향을 고려한 자연환기압 계산 fan 및 regulator의 최적 위치 및 용량 결정, 암반 열물성 및 암반 표면으로부터의 증발, 응축에 의한 수분함유량 변화를 고려한 온/습도 계산, 이류확산에 기초한 오염물질 농도 분포 계산 기능을 갖춘 네트워크형 지하공간 환경예측 모델을 개발하였다. 온/습도 예측 모델을 군수물자 지하 저장공간에 적용한 결과 실측값과 상대오차는 건구온도 1.5~2.9%, 습도온도 0.6~6.1%로 나타났다. 도로터널 2개소를 대상으로한 실험결과 외부 입기만에 의한 확산계수는 9.78과 17.35$m^2$/s 큰 편이었으나 차량 운행과 환기설비의 작동시에는 이류확산만을 고려한 경우 CO 및 매연 농도의 상대오차가 5.88과 6.62%로 비교적 작게 나타났다. 이는 대부분의 터널형 지하공간에서의 농도 분포는 이류확산만에 의하여 추정이 가능함을 의미한다.

  • PDF

NaBH4수용액 저장과정 중 안정성에 관한 연구 (Study on the Stability of NaBH4 Solution during Storage Process)

  • 심우종;조재영;최대기;남석우;박권필
    • Korean Chemical Engineering Research
    • /
    • 제48권3호
    • /
    • pp.322-326
    • /
    • 2010
  • 수소발생용으로 사용되는 $NaBH_4$ 수용액의 저장과정 중에 $NaBH_4$ 안정성에 대해 연구하였다. $NaBH_4$의 안정성을 증가시키기 위해 NaOH와 KOH를 사용하였으며, $NaBH_4$의 저장 중 가수분해반응에 미치는 알칼리와 $NaBH_4$ 농도, 온도 그리고 저장 용기 재질의 영향을 실험하였다. 알칼리농도가 증가할수록 $NaBH_4$가 수용액 중에서 안정화되기 때문에 수소발생 속도가 감소하였다. $NaBH_4$ 농도를 10에서 15 wt%로 증가시켰을 때 안정성이 감소하다 15 wt% 이상으로 농도를 증가시켰을 때는 pH의 증가에 의해 안정성이 증가하였다. $NaBH_4$ 농도를 25 wt%, NaOH 3.0 wt%일 때 수소발생 활성화 에너지 값은 115.1 kJ/mol 로 촉매를 사용했을 때보다 활성화 에너지 값이 1.5~4.0배 높았다. 유리나 스텐리스-스틸에 저장된 $NaBH_4$ 용액의 안정성이 플라스틱에 저장된 $NaBH_4$ 용액의 안정성보다 더 높았다.

기능성 음료의 유통기간 예측 (The Prediction of Self-life on Functional Beverage)

  • 이기동;김정옥;김민선;이강표
    • 한국식품저장유통학회지
    • /
    • 제13권2호
    • /
    • pp.154-160
    • /
    • 2006
  • 기능성 음료(CJ(주) 팻다운)의 유통기간을 설정하기 위해 12주 동안 저장하면서 이화학적 및 관능적 특성을 조사하였다. 진공도, 당도, pH 및 산도는 저장기간 동안 거의 변화를 나타내지 않았으며, 총균 또한 검출되지 않아 저장기간 동안 미생물학적으로도 안전한 것으로 나타났다. 관능검사의 전반적인 기호도와 이화학적 특성을 회귀분석한 결과 색도의 b (yellowness)값이 0.9504으로 가장 높은 상관계수를 나타내어 b값을 기능성 음료의 품질지표로 설정하였다. b값은 0차 반응식을 따르는 것으로 나타났으며, 각 온도별 반응상수를 이용하여 $Q_{10}$값을 구하여 유통기간을 산정한 결과 $20^{\circ}C$에서 73.89주, $30^{\circ}C$에서 34.21주, $40^{\circ}C$에서 13.21주로 나타났다. Arrhenius 식을 이용하여 계산된 활성화에너지 15.87 kcal/mol을 이용하여 실험하지 않은 온도, 즉 우리나라의 연평균 기온 $10{\sim}16^{\circ}C$에서의 저장기간을 구한 결과 $107.88{\sim}193.59$주로써 기능성 음료는 상온에서 2년간의 유통이 가능한 것으로 나타났다.

집중형 수문모형을 활용한 홍수유출자료 공간적 확장성 분석 (Spatial Extension of Runoff Data in the Applications of a Lumped Concept Model)

  • 김남원;정용;이정은
    • 한국수자원학회논문집
    • /
    • 제46권9호
    • /
    • pp.921-932
    • /
    • 2013
  • 홍수빈도해석이나 홍수예측과 같은 홍수조절을 위한 필수적인 정보는 유출자료이다. 하지만, 소규모 유역의 경우 유출자료를 측정하지 않는 미계측 유역의 다지점 분석과 총량분석을 위한 정보가 너무 부족한 실정으로 이를 극복하기 위한 방안을 제시하였다. 이를 위해 본 연구에서는 집중형 모델인 저류함수법를 활용하여 충주댐유역을 세분화하여 적용하였다. 충주댐 유역은 22개의 소유역으로 분류하였으며 충주댐 수위관측소의 유출자료의 공간적 확장성을 검증하였다. 홍수사상은 1990년부터 2009년까지의 21개 홍수사상을 활용하여 한 곳(충주댐 유입량)의 자료를 중심으로 22개 소유역의 저류함수법의 수문지형학적 특성에 관여하는 매개변수(k, p, $T_l$)를 고정하고 홍수사상마다 달라지는($f_1$, $R_{sa}$)를 최적화 하며 22개 유역의 유출자료를 생산하였다. 교차검증 지점인 영춘과 판운 수위관측소의 평균 Nash-Sutcliffe Efficiency (NSE)는 충주댐의 유입량이 0.71을 나타낼 때 각각 0.67과 0.52를 나타내 유출자료의 확장성에 있어서 만족(NSE > 0.5)하는 범위에 들어 집중형 모형을 활용한 유출자료의 확장가능성을 보였다.

시료 보관 방법에 따른 이산화탄소 시료의 유실율 평가 (Evaluation for Loss Rate of Carbon Dioxide by Sample Storage Method)

  • 조창상;이시형;임기교;유정화;사재환;전병관;전의찬
    • 한국기후변화학회지
    • /
    • 제2권4호
    • /
    • pp.309-316
    • /
    • 2011
  • 주요 온실기체인 이산화탄소의 시료 보관 방법에 따른 유실율을 평가하였다. 테들러백(tedlar bag)과 알루미늄백(aluminium bag) 용기에서 이산화탄소의 농도별, 시간별 유실율을 확인해 본 결과, 두 용기 모두 6일 경과 후에 5%, 15일 경과 후에 10% 이상의 유실율을 나타내었다. 그리고 시간이 경과됨에 테들러백보다 알루미늄백에서 유실율이 더 큰 경향을 보였고, 12일까지는 두 용기 간에 큰 차이를 보이지 않았지만 15일 경과 후부터는 알루미늄 용기의 유실율이 테들러 용기보다 더 큰 것으로 확인되었다. 습도와 유실율과의 관계를 조사한 결과에서는 72시간까지 습도에 큰 영향을 받지 않았으나 72시간 이후에는 차이를 보였으며, 높은 습도의 테들러백에서 유실율이 습도가 낮은 상태의 테들러백보다 약 5% 정도 높게 나타났다. 이산화탄소에 대한 정확한 배출량 및 배출계수를 산정하기 위해서는 이러한 시료보관 방법에 따른 유실율을 고려해야 분석 결과의 신뢰도를 높일 수 있을 것으로 보인다.

COMSOL Multiphysics®와 PyLith의 순차 적용을 통한 지중 유체 주입과 유발지진 공탄성 수치 모사 기법 연구 (Sequential Use of COMSOL Multiphysics® and PyLith for Poroelastic Modeling of Fluid Injection and Induced Earthquakes)

  • 장찬희;김현나;소병달
    • 지질공학
    • /
    • 제32권4호
    • /
    • pp.643-659
    • /
    • 2022
  • 최근 지중저장기술(예, 온실가스 심지층 처분, 인공지열저류층 발전 등)이 활발히 수행됨에 따라, 유체 주입과 저장부지 안정성 사이의 역학적 관계에 관한 정량적 이해의 중요성이 인지되고 있다. 지중 유체 주입은 공극압 및 지중응력 교란과 지층의 역학적 불안정성을 야기할 수 있어, 유체 주입에 대한 다공탄성 수치 모형 구축이 요구된다. 본 연구에서는 순차적인 COMSOL-PyLith-COMSOL 유체 주입-유발지진 다공탄성 수치 모사를 수행한다. 유한요소 상용 소프트웨어인 COMSOL을 이용해 단층에 가해지는 쿨롱 파괴 응력(CFS) 변화를 시간에 따라 추적하였고, CFS 변화량이 임계값(예, 0.1 MPa)을 초과할 경우, 모형의 정보(기하구조, 물성 등)를 유한요소 오픈소스 코드인 PyLith로 이동시키는 알고리즘을 구축했다. PyLith는 단층의 미끄러짐을 모사하고, 미끌림에 의한 변위장을 획득한다. 이후 변위장을 COMSOL로 이동시켜 지진에 의한 응력 및 표면 변위를 계산한다. 수치 모사 결과, 주입 기간 중엔 주입정 근거리에서 큰 변화(공극압, CFS 변화 등)를 보였고, 주입 종류 후에는 잔류 응력이 원거리 영역으로 확산하는 양상이 나타났다. 이는 주입 종료 후 지속적인 모니터링의 필요성을 제안한다. 또한, 단층과 주입층 물성(예, 투수계수, Biot-Willis 계수)에 따른 CFS 변화량 비교는 주입정 위치 선정 시 주입층 및 주변 지층에 대한 물성 파악이 중요함을 의미한다. 단층 미끄러짐 양에 따른 표면 변위 및 이암층에 가해지는 편차응력은 다양한 단층 미끌림 시나리오 설정의 필요성을 지시한다.

감자의 세척유무 및 저장온도에 따른 녹화 및 상품성 유지 기간 구명 (Determination of Greening and Shelf Life of Potato Based on Washing and Storage Temperature Conditions)

  • 김수정;손황배;홍수영;남정환;장동칠;서종택;김율호
    • 한국작물학회지
    • /
    • 제62권1호
    • /
    • pp.66-72
    • /
    • 2017
  • 감자에서 녹화는 유통과정에서 괴경의 상품성을 좌우하는 매우 중요한 품질 지표이다. 본 연구는 우리나라 대표감자 품종인 '수미'의 수확후 세척유무 및 보관온도에 따른 녹화와의 관련성을 비교 분석하고자 수행되었다. Hunter a값은 세척하지 않은 감자(대조구)에 비해 세척한 감자가 a값의 변화가 심하였으며, 특히 세척감자의 경우 고온($20^{\circ}C$)보다 저온($4^{\circ}C$) 보관할 경우 실온저장 3일부터 -0.8로 시작하여 15일에 -2.5로 떨어져 녹화가 심하였다. 색차값 역시 세척하지 않은 감자(대조구)보다 세척감자에서 실온저장 3일부터 급격히 증가하였다. 저장기간이 길어짐에 따라 엽록소 함량이 모든 처리구에서 증가하였는데, 저온($4^{\circ}C$)에서 1개월 보관한 후 실온에 저장한 세척감자에서 저장 12일에 $26.7mg{\cdot}g-1$로 가장 함량이 많았다. 괴경녹화와 각 녹화평가 요인의 상관성을 피어슨 상관분석한 결과, 엽록소 함량은 Hunter a값와 b값과는 부의 상관관계를 보였고, 색차값과는 정의 상관관계를 보였다. 따라서, 색도, 색차 및 엽록소 함량 등의 결과를 바탕으로 녹화는 세척유무 및 보관온도에 영향을 받는 것으로 판단되었다.