• 제목/요약/키워드: Storage coefficient

검색결과 470건 처리시간 0.027초

Ion Chromatography/Visible Absorbance Detection을 이용한 Cr(VI) 분석의 정확도 및 정밀도 평가 (Accuracy and Precision of Ion Chromatography/Visible Absorbance Detection for Analyzing Hexavalent Chromium Collected on PVC Filter)

  • 신용철;오세민;백남원
    • 한국산업보건학회지
    • /
    • 제7권2호
    • /
    • pp.223-232
    • /
    • 1997
  • The accuracy and precision of a modified method of NIOSH Method 7600 and EPA method 218.6 was determined for analyzing hexavalent chromium, Cr(VI), collected on PVC filter from workplace air. The method was designed to extract from Cr(VI) on PVC filter with a alkali solution, 2% NaOH/3% $Na_2CO_3$, and to analyze it using ion chromatography/visible absorbance detection(IC/VAD). The results and conclusion are as the following. 1. The peak of Cr(VI) was separated sharply on chromatogram and was linearly related with Cr(VI) concentration in sloution. The correlation coefficient was 0.9999 in a calibration curve. The limit of detection was 0.25 $0.25{\mu}g/sample$. 2. The accuracy(% recovery) was 93.3% in a set of sample($9-50{\mu}g$) stored for a day, and 100.1%($10-60{\mu}g$) in another set of samples stored for 2 hours. It is assumed that the difference in recovery by storage time was due to reduction of Cr(VI) to Cr(III). 3. The precision(coefficient of variation, CV) of the method was 0.015 in spiked samples with Cr(VI) standard solution, and 0.010 in spiked samples with plating solution from a chrome electroplating factory. The overall CV in all types of samples was 0.0013. 4. The Cr(VI) was stable in 2% NaOH/3% $Na_2CO_3$ at least for 10 hours. In conclusion, the IC/VAD method is appropriate for determining low-level Cr(VI) in workplace air containing various interferences.

  • PDF

Fe-LiNbO$_3$결정에서 부피형 홀로그램의 회절특성을 이용한 광정보 저장 (Optical information storage using diffraction properties of volume hologram in Fe-LiNbO$_3$ crystal)

  • 안준원;김남;이권연
    • 전자공학회논문지D
    • /
    • 제35D권6호
    • /
    • pp.63-71
    • /
    • 1998
  • 본 논문에서는 Fe가 0.015Wt.%도핑된 LiNbO₃ 결정에서 2광파혼합(TWM:Two-Wave Mixing)을 통한 입사각에 따른 결합계수, 기록빔의 세기비에 따른 이득, 회절효율, 시간응답특성에 대한 해석 및 실험을 통해 고밀도 광메모리 소자로서 응용하기 위한 특성을 제시한다. 실험결과 514.5nm 파장에서 본 결정의 경우 14°에서 최대 결합특성을 보였고 이때의 최대결합계수는 6.9cm/sup -1/이다. 그리고, 632.8nm 파장의 빔으로 판독시 두 결합빔의 세기비가 0.1이고, 입사각이 140 일 때, 54.13%의 최대 회절효율을 얻었으며, 격자고정시 회절효율은 21.4% 이다. 또한, Fe-LiNbO₃ 결정을 높은 회절효율을 갖는 광메모리 소자로 적용하기 위해 가장 우수한 회절특성을 보이는 조건에서 각도 다중화 방식과 공간 광학 변조기를 이용한 광정보 저장응용실험 결과를 제시하였다.

  • PDF

LNG FPSO 액화공정에 적용되는 플레이트 핀 열교환기의 열전달 특성 (Heat Transfer Characteristics of Plate-fin Heat Exchanger Using LNG FPSO Liquefaction Process)

  • 유선일;김현우;정영권;윤정인;박승하;김창수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제34권6호
    • /
    • pp.798-805
    • /
    • 2010
  • LNG FPSO 액화 플랜트와 같은 초저온 분야에서 플레이트 핀 열교환기의 국내 연구 실적은 전무한 상태이다. 본 연구에서는 플레이트 핀 열교환기의 독자적 기술을 확보하기 위해 응축 열전달 특성을 이론 및 실험적으로 검증하였다. 시뮬레이션 결과 Plain fin을 제외한 Serrated, Wavy fin은 압력 69bar, 온도 $-140^{\circ}C$에서 응축되었고, 국소열전달계수는 Serrated, Wavy, Plain fin 순으로 높게 나타났다. 실험결과는 정상상태에서 10분간 데이터를 획득하였고 시뮬레이션 데이터값과 12% 미만의 오차범위를 만족하였다.

진공채혈관의 상태에 따른 평가 (Evaluation of Vacutainer Distribution Conditions)

  • 박창은
    • 대한임상검사과학회지
    • /
    • 제48권2호
    • /
    • pp.109-113
    • /
    • 2016
  • 분석전 변이로 인하여 검사실은 오류에 직면하게 되고 많은 요인들은 환자의 검사결과에 영향을 미치게 된다. 다양한 진공채혈관은 신속하게 분리하고 방치된 검체의 용혈을 방지한다. 그러나 진공채혈관의 상태에 따라 몇 가지 제한점들이 발생하는데 이러한 문제점을 알아보기 위해 다양한 진공채혈관을 이용해 혈구산정검사로 비교 평가하였다. 유통기한별 검사결과에서는 백혈구(WBC)와 혈소판(PLT)의 값에서 0.24, 0.21로 큰 변이계수를 나타냈고 상관성에서는 백혈구(WBC), 혈소판(PLT), 적혈구(RBC)의 값이 유의성을 보였다(p<0.01). 한편 각 3사의 비교평가에서는 백혈구(WBC), 혈소판(PLT)의 값에서 0.27, 0.21로 가장 큰 변이계수를 나타냈고, 상관성에서는 각 3사가 모두 백혈구(WBC), 혈소판(PLT), 혈소판분포폭(PDW)의 값에서 높은 유의한 차이를 보였다(p<0.01) 그러나 G사와 B사는 혈소판(PLT), 혈소판분포폭(PDW)의 값에서는 낮은 유의한 차이를 보였다(p<0.05). 결론적으로 진공채혈관의 상태에 따른 분석의 안정성을 위해 적절한 진공채혈관의 분석평가가 이루어져야 한다.

삶은 국수의 조직감 평가를 위한 층밀림 압출 실험 (Development of Shear Extrusion Test for the Texture Evaluation of Cooked Noddle)

  • 유병승;이철호
    • 한국식품과학회지
    • /
    • 제19권2호
    • /
    • pp.171-175
    • /
    • 1987
  • 삶은 국수의 식미 평가를 위한 객관적 측정 방법으로 레오메타에 특수하게 고안한 test cell을 사용하는 층밀림 압출 시험법을 개발하였다. 층밀립 압출 시험에서 얻어지는 힘-거리 곡선을 분석하여 최초 압출력, 최고 압출력, 압출일, 경사도 등의 파라메타를 구하였다. 17종류의 호주밀로부터 만든 밀국수(건면)에 대한 실험 결과, 최초 압출력 압출일은 삶은 국수의 기호도를 가장 크게 영향하는 단단하고 무른 성질과 쫄깃쫄깃한 성질의 정도를 나타낼 수 있었다. 한편, 경사도는 삶은 국수의 저장중에 일어나는 조직감 변화를 감지할 수 있었다. 이들 파라메타들은 원료 밀가루의 단백질 함량, 수분흡수력, 발전시간(D.T.), 인장도와 높은 삼관관계를 나타내었으나 비스코그램의 최고 점도와는 상관관계를 나타내지 않았다. 비스코스램의 최고 점도와 층밀림 압출 시험의 최고 압출력을 두 독립변수로 한 다중회귀분석 결과 관능적 조직감 기호도와의 상관계수는 최고 압출력만을 사용한 단순회귀분석상관계수보다 크게 증가하지 않았다.

  • PDF

Development of a Real-Time Measurement System for Horizontal Soil Strength

  • Cho, Yongjin;Lee, Dong Hoon;Park, Wonyeop;Lee, Kyou Seung
    • Journal of Biosystems Engineering
    • /
    • 제40권3호
    • /
    • pp.165-177
    • /
    • 2015
  • Purpose: Accurate monitoring of soil strength is a key technology applicable to various precision agricultural practices. Soil strength has been traditionally measured using a cone penetrometer, which is time-consuming and expensive, making it difficult to obtain the spatial data required for precision agriculture. To improve the current, inefficient method of measuring soil strength, our objective was to develop and evaluate an in-situ system that could measure horizontal soil strength in real-time, while moving across a soil bin. Methods: Multiple cone-shape penetrometers were horizontally assembled at the front of a vertical plow blade at intervals of 5 cm. Each penetrometer was directly connected to a load cell, which measured loads of 0-2.54 kN. In order to process the digital signals from every individual transducer concurrently, a microcontroller was embedded into the measurement system. Wireless data communication was used between a data storage device and this real-time horizontal soil strength (RHSS) measurement system travelling at 0.5 m/s through an indoor experimental soil bin. The horizontal soil strength index (HSSI) measured by the developed system was compared with the cone index (CI) measured by a traditional cone penetrometer. Results: The coefficient of determination between the CI and the HSSI at depths of 5 cm and 10 cm ($r^2=0.67$ and 0.88, respectively) were relatively less than those measured below 20 cm ($r^2{\geq}0.93$). Additionally, the measured HSSIs were typically greater than the CIs for a given numbers of compactor operations. For an all-depth regression, the coefficient of determination was 0.94, with a RMSE of 0.23. Conclusions: A HSSI measurement system was evaluated in comparison with the conventional soil strength measurement system, CI. Further study is needed, in the form of field tests, on this real-time measurement and control system, which would be applied to precision agriculture.

이중 완전 Shuffle을 이용한 Radix-4 FFT 프로세서의 설계 (Design of Radix-4 FFT Processor Using Twice Perfect Shuffle)

  • 황명하;황호정
    • 대한전자공학회논문지
    • /
    • 제27권2호
    • /
    • pp.144-150
    • /
    • 1990
  • 본 논문에서는 레딕스(radix)-2 FFT 알고리듬에 이용하였던 완전 셔플(shuffle)을 확장하여 새로이 얻은 이중 와전 셔플을 적용하여 레딕스-4 FFT 프로세서를 설계하였다. 이 FFT 프로세서는 버터플라이 연산 회로, 입, 출력값과 계수의 번지 발생기, 입, 출력값을 일시 저장하는 레지스터와 제어회로로 구성된다. 또한 입, 출력값과 계수를 저장하기 위해 외부 RAM과 ROM을 필요로 한다. 버터플라이 회로는 12개의 곱셈기와 덧셈기, 뺄셈기, 딜레이 시프트 레지스터(delay shift register)로 되어 있다. 25MHz two phase 클럭으로 동작하는 이 프로세서는 256-절 FFT를 6168 클럭, 즉 247 us 에 계산을 하며 또한, 사용자가 4, 16, 64, 256- 점까지 임의의 점을 선택할 수 있는 유연성을 갖는다. 그리고 2-um 이중 메탈 CMOS 공정을 이용하여 28000 여개의 트랜지스터와 55개의 패트를 $8.0{\times}8.2mm^2$면적에 설계할 수 있었다.

  • PDF

화산도서에서 유한차분법을 이용한 지하수 유동해석 (Groundwater Flow Analysis Using Finite Difference Method in Volcanic Island)

  • 최윤영;이순탁
    • 한국수자원학회논문집
    • /
    • 제33권5호
    • /
    • pp.611-622
    • /
    • 2000
  • 본 연구에서는 제주도 서귀포유역의 지하수 유동시스템 해석을 위해 MODFLOW 모델을 이용하였으며 양수량 측정자료를 통한 투수량계수 및 저류계수를 초기치로 선정하여 시행착오법을 통한 대상유역의 최종 매개변수를 얻을 수 있었고 모델의 모의 발생을 한 결과 지하수유동시스템에 대한 적용성이 잘 반영됨을 알 수 있었다. 서귀포 유역은 지형지질을 고려한 관측치 해석, 이(1996)의 연구결과 및 모의발생을 통한 결과로 볼 때 지하수두 분포는 표고 400m이내에서 안정된 지하수 함양에 의한 용출이 이루어지고 있는 것으로 판단된다. 또한, 부정류상태하에서 지하수 유동경로 해석을 위하여 수두분포의 결과치를 이용한 유속벡터 분석을 실시한 결과 유속벡터가 상대적으로 크게 나타난 지역은 II, III 및 Ⅵ지점이었으며 지하수 유동경로는 I, II, III, IV, V, Ⅵ 및 Ⅶ지점의 각 방향으로 분산되어 유출되고 있음을 알 수 있었다.

  • PDF

수분 제거를 위한 식물세포 Taxus chinensis의 마이크로웨이브를 이용한 건조 특성 (Characteristics of Microwave-Assisted Drying of Plant Cells of Taxus chinensis for Moisture Removal)

  • 남현우;김진현
    • 공업화학
    • /
    • 제31권2호
    • /
    • pp.208-214
    • /
    • 2020
  • 본 연구에서는 식물세포 Taxus chinensis로부터 수분 제거를 통한 바이오매스 보관 및 추출 효율 향상을 위하여, 마이크로웨이브를 이용한 건조의 특성 및 메커니즘을 조사하였다. 마이크로웨이브 파워가 100, 200, 300 W로 증가함에 따라 수분의 제거 효율은 증가하였다. 실험 데이터를 대표적 동역학적 건조 모델에 적용할 때, Page 모델과 modified Page 모델이 가장 적합한 것으로 결정되었다. 열역학적 파라미터는 마이크로웨이브를 이용한 건조의 자발적 및 흡열특성을 나타내었으며, 건조 과정에서 무질서도는 증가함을 알 수 있었다. 마이크로웨이브 파워(100~300 W)가 증가함에 따라 수분의 유효확산계수(3.445 × 10-9~7.163 × 10-7 ㎡/s) 및 대류물질전달계수(3.1529 × 10-5~1.2895 × 10-2 m/s)가 증가하였다. 작은 비오트 수(0.3890~0.7198)를 고려할 때, Taxus chinensis의 건조 진행은 외부 확산에 의해 조절됨을 알 수 있었다.

동적 시정수 기반 고성능 절연 저항 계산 기법 (Dynamic Time Constant Based High-Performance Insulation Resistance Calculation Method)

  • 손기범;홍종필
    • 한국정보통신학회논문지
    • /
    • 제24권8호
    • /
    • pp.1058-1063
    • /
    • 2020
  • 본 논문에서는 IT 접지 시스템의 감전 및 화재사고 방지를 위한 새로운 절연 저항 계산 기법을 소개한다. 최근 신재생 에너지와 에너지 저장 장치의 확대 보급으로 태양광 발전 시장이 급속하게 성장하고 있으나 절연이 파괴되어 화재사고가 빈번히 발생함에 따라 IT 접지 방식에도 절연 저항 상태를 감시하는 장치가 필수적으로 요구되고 있다. 제안하는 절연 저항 계산 기법은 기존의 고정된 시정수곱 계수기반의 알고리즘에 비해 절연 임피던스의 조건에 따라 동적시정수곱계수를 적용함으로써 넓은 절연 저항 범위에서 빠른 응답 시간과 높은 정확도를 갖는다. 제안하는 동적 시정수 기반 절연 저항 계산 기법은 기존의 방법에 비해 최대 응답 시간은 39.29초, 오차율은 20.11%를 개선시키는 효과를 보였다.