• 제목/요약/키워드: Storage coefficient

검색결과 470건 처리시간 0.026초

Techno-Economic Optimization of a Grid-Connected Hybrid Energy System Considering Voltage Fluctuation

  • Saib, Samia;Gherbi, Ahmed;Kaabeche, Abdelhamid;Bayindir, Ramazan
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.659-668
    • /
    • 2018
  • This paper proposes an optimization approach of a grid-connected photovoltaic and wind hybrid energy system including energy storage considering voltage fluctuation in the electricity grid. A techno-economic analysis is carried out in order to minimize the size of hybrid system by considering the benefit-cost. Lithium-ion battery type is used for both managing the electricity selling to the grid and reducing voltage fluctuation. A new technique is developed to limit the voltage perturbation caused by the solar irradiance and the wind speed through determining the state-of-charge of battery for every hour of a day. Improved particle swarm optimization (PSO) methods, referred to as FC-VACPSO which combines Fast Convergence Particle Swarm Optimization (FCPSO) method and Variable Acceleration Coefficient Based Particle Swarm Optimization (VACPSO) method are used to solve the optimization problem. A comparative study has been performed between standard PSO method and PSO based methods to extract the best size with the benefit cost. A sensitivity analysis has been studied for different kinds and costs of batteries, by considering variable and constant state-ofcharge of battery. The simulations, performed under Matlab environment, yield good results using the FC-VACPSO method regarding the convergence and the benefit cost of the hybrid system.

태양열 온실 난방에 대한 최척 집열 면적과 경제성 평가 (Optimum Collector Area and Economic Evaluation for the Greenhouse Heating)

  • 박이동;김규인
    • 태양에너지
    • /
    • 제2권1호
    • /
    • pp.49-58
    • /
    • 1982
  • Aim of this study was to obtain the heating performance and the economic evaluation on solar heating system for greenhouse which area of floor was $90m^2$. For heating performance effective solar energy for the greenhouse was compared with overall heating loads including coefficient of heat transfer and conduction. And the economic evaluation solar heating system was evaluated by comparison its initial investiment costing with oil saving cost. Initial investiment costing included collector cost, storage cost, piping cost, control system cost and miscellaneous costs which included pumps, motors etc. The contents of this study included the survey of climate conditions for solar heating, long-term collector performance and optimum collector area of solar heating system in existing greenhouse. The results are follows: 1. Average horizontal radiation during winter was $2,434Kcal/m^2$ day which was the highest value in this country, so the climate conditions of Suwon was suitable for solar heating. 2. Resulting calculation of the optimum collector area was $30m^2$ and the solar energy accounted for 30% of the overall heating load. 3. The capacity of storage tank required 60 liter per unit area ($m^2$) of solar collector.

  • PDF

부유식 석유생산.저장.하역선박의 소음해석 (A Noise Prediction of Floating, Production, Storage and Offloading(FPSO))

  • 김영현;김동해
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.307-310
    • /
    • 2000
  • Recently, the demand for the Floating, Production Storage, and Offloading facility(FPSO) which has some economic and technical advantages, has increased in offshore oil production areas. The basic characteristics of a 343,000 DWT class FPSO which is being built in Hyundai Heavy Industries and shall be installed in offshore Angola, is almost same as that of oil carriers. However, she do not have self-propulsion system, but has additional facilities for oil production and positioning system. Main noise source contributing to the cabin noise of the accommodation, are classified into the machine in the engine room and the deckhouse, HVAC system, and the topside equipments. In general, the noise regulation for the offshore structure is much severer than that of the common commercial ships and the maximum acceptable sound pressure level of cabins is specified in 45dB(A). This paper describes the procedure of noise analysis along with its results. Noise analysis has been carried out for the case of emergency diesel generator running condition and the case of normal production condition and the results has been compared with the measurement results of the first case. Based on the results, proper countermeasures to reduce excessive noise level has been applied considering the characteristics of sources and receiver spaces and can be satisfied the specifications at all spaces.

  • PDF

고속 회전 유연 디스크 시스템에서 곡면 안정기에 가공된 모세관형 오리피스의 감쇠계수 해석 (An Analysis of Damping Coefficients for Capillary Type Orifices on a Curved Stabilizer used in a High Speed Rotating Flexible Optical Disk System)

  • 송기욱;임윤철
    • 정보저장시스템학회논문집
    • /
    • 제7권1호
    • /
    • pp.25-30
    • /
    • 2011
  • In the last couple of years, the flexible optical disk(FOD) system that consists of a thin polycarbonate(PC) film of 95 ${\mu}m$ thick, a rigid stabilizer, and a high speed spindle motor has been spot-lighted as the next-generation optical system for archival use of digital data. The air film between the rotating disk and stabilizer provides a means for damping out the lateral disk vibrations. However, its damping-capability drops significantly as the rotational speed of the disk exceeds a specific limit and, eventually, the disk vibration propagates inward causing the whole span of the disk exhibits large vibration amplitudes. Based on the numerical simulations as well as the experimental results, the present work aims to evaluate the damping coefficient of the air-film near the outer region of the disk where the capillary type orifices are applied to the edge of the curved stabilizer.

Numerical modelling of shelter effect of porous wind fences

  • Janardhan, Prashanth;Narayana, Harish
    • Wind and Structures
    • /
    • 제29권5호
    • /
    • pp.313-321
    • /
    • 2019
  • The wind blowing at high velocity in an open storage yard leads to wind erosion and loss of material. Fence structures can be constructed around the periphery of the storage yard to reduce the erosion. The fence will cause turbulence and recirculation behind it which can be utilized to reduce the wind erosion and loss of material. A properly designed fence system will produce lesser turbulence and longer shelter effect. This paper aims to show the applicability of Support Vector Machine (SVM) to predict the recirculation length. A SVM model was built, trained and tested using the experimental data gathered from the literature. The newly developed model is compared with numerical turbulence model, in particular, modified $k-{\varepsilon}$ model along with the experimental results. From the results, it was observed that the SVM model has a better capability in predicting the recirculation length. The SVM model was able to predict the recirculation length at a lesser time as compared to modified $k-{\varepsilon}$ model. All the results are analyzed in terms of statistical measures, such as root mean square error, correlation coefficient, and scatter index. These examinations demonstrate that SVM has a strong potential as a feasible tool for predicting recirculation length.

고성능 섬유형 슈퍼커패시터를 위한 탄소섬유의 표면 기능화 (Surface Functionalization of Carbon Fiber for High-Performance Fibrous Supercapacitor)

  • 이영근;안건형
    • 한국재료학회지
    • /
    • 제32권2호
    • /
    • pp.107-113
    • /
    • 2022
  • Fibrous supercapacitors (FSs), owing to their high power density, good safety characteristic, and high flexibility, have recently been in the spotlight as energy storage devices for wearable electronics. However, despite these advantages, FCs face many challenges related to their active material of carbon fiber (CF). CF has low surface area and poor wettability between electrode and electrolyte, which result in low capacitance and poor long-term stability at high current densities. To overcome these limits, fibrous supercapacitors made using surface-activated CF (FS-SACF) are here suggested; these materials have improved specific surface area and better wettability, obtained by introducing porous structure and oxygen-containing functional groups on the CF surface, respectively, through surface engineering. The FS-SACF shows an improved ion diffusion coefficient and better electrochemical performance, including high specific capacity of 223.6 mF cm-2 at current density of 10 ㎂ cm-2, high-rate performance of 171.2 mF cm-2 at current density of 50.0 ㎂ cm-2, and remarkable, ultrafast cycling stability (96.2 % after 1,000 cycles at current density of 250.0 ㎂ cm-2). The excellent electrochemical performance is definitely due to the effects of surface functionalization on CF, leading to improved specific surface area and superior ion diffusion capability.

해운.항만산업의 경제적 파급효과 분석 (An Analysis of the Economic Effects of Marine Transport and Port Industry)

  • 정분도;심재희
    • 한국항만경제학회지
    • /
    • 제27권3호
    • /
    • pp.311-329
    • /
    • 2011
  • 해운 항만산업은 수출입의 최전선이자 무한한 부가가치를 창출하는 국가적 산업이다. 최근의 세계 경제위기로 인해 항만물동량이 둔화되는 등 우리의 해운 항만산업의 어려움을 겪고 있다. 이러한 어려움은 이를 어떻게 준비하고 대응하느냐에 따라서 새로운 도약을 위한 기회가 될 수 있다. 해운 항만 업체 스스로 끊임없는 노력을 통해 경쟁력을 강화한다면 머지않아 국내에도 외국 해운 항만업체와 당당하게 경쟁할 수 있는 대표적인 업체가 생겨날 것이다. 따라서 본 연구에서는 국내 해운 항만 산업의 경제적 파급효과를 산업연관표를 이용하여 살펴보고자 한다. 산업연관표를 이용하여 해운 항만산업의 경제적 효과를 요약하면, 첫째, 2005년 생산유발계수는 항만시설이 1.958로 가장 높고 다음으로 연안 및 내륙수상운송 1.857, 하역 1.842, 기타 운수관련서비스 1.768, 보관 및 창고 1.676, 수상운수보조서비스 1.422, 외항운송이 1.283 순으로 나타났다. 둘째, 부가가치유발계수를 살펴보면, 수상운수보조서비스 0.924, 하역, 보관 및 창고 0.902, 기타 운수관련서비스 0.885, 항만시설 0.832, 연안 및 내륙수상운송 0.752, 외항운송이 0.258로 가장 낮게 나타났다. 셋째, 2005년 중 수입유발계수를 보면, 외항운송 0.742, 연안 및 내륙수상운송 0.248, 항만시설 0.168, 기타 운수관련서비스 0.115, 하역, 보관 및 창고 0.098, 수상운수보조서비스가 0.076으로 가장 낮게 나타났다. 넷째, 기타 운수 관련서비스(1.125)와 하역(0.882)의 감응도계수가 높고, 항만시설과 외항운송이 0.514로 감응도계수가 낮다. 항만시설(1.006)과 연안 및 내륙수상운송(0.954), 하역(0.946), 기타 운수관련 서비스(0.908)의 영향력계수가 높고, 반면 외항운송(0.659)의 영향력계수가 낮다.

대용량 이차전지 관리 시스템용 전력형 션트저항의 열기전력 안정화 (Stabilization of Thermo Electromotive Force of Power Type Shunt Resistor for Mass Storage Secondary Battery Management System)

  • 김은민;이선우
    • 한국전기전자재료학회논문지
    • /
    • 제30권6호
    • /
    • pp.376-380
    • /
    • 2017
  • In this paper, we prepared a metal alloy resistor with stable thermal electro motive force (thermal EMF) as well as a low temperature coefficient of resistance (TCR) by adjusting the manganese proportion from 3 to 12 wt% in the Cu-Mn-Ni alloy. Composition of the fabricated metal alloy was investigated using energy dispersive X-ray (EDX) analysis. The TCR of each sample was measured as 44.56, 40.54, 35.60, and 31.56 ppm for Cu-3Mn-2Ni, Cu-5Mn-2Ni, Cu-10Mn-2Ni, and Cu-12Mn-2Ni, respectively. All the resistor samples were available for the F grade (${\pm}1%$ of the allowable error of resistance) high-precision resistor. All the samples satisfied the baseline of high thermal EMF (under 3 mV at $60^{\circ}C$); however, Cu-3Mn-2Ni and Cu-5Mn-2Ni satisfied the baseline of low thermal EMF (under 0.3 mV at $25^{\circ}C$). We were thus able to design and fabricate the metal alloy resistor of Cu-3Mn-2Ni and Cu-5Mn-2Ni to have low TCR and stable thermal EMF at the same time.

평판의 면내 자유진동 해석 (In-Plane Free Vibration Analysis of Plates)

  • 최명수;여동준;변정환;장덕종;문덕홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.291-296
    • /
    • 2007
  • To analyze accurately the free vibration of a structure by using the finite element method (FEM), we model the structure as a numerical model with many degrees-of-freedom. However the FEM needs much computation time and storage in this case. The authors developed the finite element-transfer stiffness coefficient method (FE-TSCM) for overcoming the drawback of the FEM. In this paper, the authors apply the FE-TSCM to the in-plane free vibration analysis of plates with various shapes. Two numerical examples, a rectangular plate and a triangular plate, are used to compare the results of the FE-TSCM and the FEM. Through the numerical calculation, we confirm that the FE-TSCM can be applied to the plates with various shapes and is effective to in-plane free vibration analysis of plates.

  • PDF

Sorption of chlorophenols on geotextile of the geosynthetic clay liners

  • Ahari, M'hamed;Touze-Foltz, Nathalie;Mazeas, Laurent
    • Environmental Engineering Research
    • /
    • 제25권2호
    • /
    • pp.163-170
    • /
    • 2020
  • Knowledge of organic micropollutant transfers in barrier seal materials from waste storage facilities is limited to volatile organic compounds and phenolic compounds at ambient temperature. This study focused on the sorption of chlorophenols (CPs) from various geotextiles from clay geosynthetics under the influence of temperature. Also to study the impact of the polarity or the amount of CPs adsorbed on geotextiles with the partition coefficient. The effect of various parameters such as contact time, effect of temperature, initial CPs concentration and adsorbent dosage has been carried out in this study. The result obtained is non-linear and the data was calculated for affinity with Freundlich isotherm model. An important observation is that the amount of CPs sorbed on geotextiles increases with a growing number of chlorine atoms, ie increases with the partition coefficient (log Kow). During this study, a decrease in adsorbent properties was observed with the rise in temperature from 23℃ to 55℃. The partitioning coefficients for CPs examined range are from 2.4 (R2 = 0.86) to 8.4 mL/g (R2 = 0.90). Among the CPs studied, the highest adsorbed quantity was observed for pentachlorophenol with 0.052 g/g at 23℃, this quantity will decrease with the increase in temperature.