• Title/Summary/Keyword: Storage Units

Search Result 310, Processing Time 0.031 seconds

A Simultaneous Hardware Resource Allocation and Binding Algorithm for VLSI Design (VLSI 설계를 위한 동시수행 하드웨어 자원 할당 및 바인딩 알고리듬)

  • 최지영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.25 no.10A
    • /
    • pp.1604-1612
    • /
    • 2000
  • This paper proposes a simultaneous hardware resource allocation and binding algorithm for VLSI design. The proposed algorithm works on scheduled input graph and simultaneously allocates binds functional units, interconnections and registers by considering interdependency between operations and storage elements in each control step, in order to share registers and interconnections connected to functional units, as much as possible. Also, the register allocation is especially executes the allocation optima us-ing graph coloring techniques. Therefore the overall resource is reduced. This paper shows the effectiveness of the proposed algorithm by comparing experiments to determine number of functional unit in advance or to separate executing allocation and binding of existing system.

  • PDF

Experimental validation of the seismic analysis methodology for free-standing spent fuel racks

  • Merino, Alberto Gonzalez;Pena, Luis Costas de la;Gonzalez, Arturo
    • Nuclear Engineering and Technology
    • /
    • v.51 no.3
    • /
    • pp.884-893
    • /
    • 2019
  • Spent fuel racks are steel structures used in the storage of the spent fuel removed from the nuclear power reactor. Rack units are submerged in the depths of the spent fuel pool to keep the fuel cool. Their free-standing design isolates their bases from the pool floor reducing structural stresses in case of seismic event. However, these singular features complicate their seismic analysis which involves a transient dynamic response with geometrical nonlinearities and fluid-structure interactions. An accurate estimation of the response is essential to achieve a safe pool layout and a reliable structural design. An analysis methodology based on the hydrodynamic mass concept and implicit integration algorithms was developed ad-hoc, but some dispersion of results still remains. In order to validate the analysis methodology, vibration tests are carried out on a reduced scale mock-up of a 2-rack system. The two rack mockups are submerged in free-standing conditions inside a rigid pool tank loaded with fake fuel assemblies and subjected to accelerations on a unidirectional shaking table. This article compares the experimental data with the numerical outputs of a finite element model built in ANSYS Mechanical. The in-phase motion of both units is highlighted and the water coupling effect is detailed. Results show a good agreement validating the methodology.

Technology Trends in CXL Memory and Utilization Software (CXL 메모리 및 활용 소프트웨어 기술 동향 )

  • H.Y. Ahn;S.Y. Kim;Y.M. Park;W.J. Han
    • Electronics and Telecommunications Trends
    • /
    • v.39 no.1
    • /
    • pp.62-73
    • /
    • 2024
  • Artificial intelligence relies on data-driven analysis, and the data processing performance strongly depends on factors such as memory capacity, bandwidth, and latency. Fast and large-capacity memory can be achieved by composing numerous high-performance memory units connected via high-performance interconnects, such as Compute Express Link (CXL). CXL is designed to enable efficient communication between central processing units, memory, accelerators, storage, and other computing resources. By adopting CXL, a composable computing architecture can be implemented, enabling flexible server resource configuration using a pool of computing resources. Thus, manufacturers are actively developing hardware and software solutions to support CXL. We present a survey of the latest software for CXL memory utilization and the most recent CXL memory emulation software. The former supports efficient use of CXL memory, and the latter offers a development environment that allows developers to optimize their software for the hardware architecture before commercial release of CXL memory devices. Furthermore, we review key technologies for improving the performance of both the CXL memory pool and CXL-based composable computing architecture along with various use cases.

Block based Smart Carving System for Forgery Analysis and Fragmented File Identification

  • Lee, Hanseong;Lee, Hyung-Woo
    • Journal of Internet Computing and Services
    • /
    • v.21 no.3
    • /
    • pp.93-102
    • /
    • 2020
  • In order for data obtained through all stages of digital crime investigation to be recognized as evidence capability, it must satisfy legal / technical requirements. In this paper, we propose a mechanism and implement software to provide digital forensic evidence by automatically recovering files by scanning / inspecting the unallocated area inside the storage disk block without relying on information provided by the file system. The proposed technique checks / analyzes the RAW disk data of the system under analysis in 512-byte block units based on information on the storage format / file structure of various files stored on the disk without referring to the file system-related information provided by the operating system. The file carving process was implemented, and a smart carving mechanism was proposed to intelligently restore deleted or damaged files in the storage device. As a result, we have provided a block based smart carving method to intelligently identify fragmented and damaged files in storage efficiently for forgery analysis on digital forensic investigation.

Analysis of the Bacterial Community during the Storage of Gorosoe(Acer mono Max.) Sap (고로쇠 수액의 저장 중 세균군집 분석)

  • Oh, Jung-Hwan;Seo, Sang-Tae;Oh, Hye-Young;Hong, Jin-Sung;Kang, Ha-Young
    • The Korean Journal of Food And Nutrition
    • /
    • v.22 no.4
    • /
    • pp.492-496
    • /
    • 2009
  • The composition of the bacterial populations in Gorosoe(Acer mono Max.) sap was characterized during storage with different heat treatments($63^{\circ}C$ for 30 min and $73^{\circ}C$ for 15 sec). The saps were aseptically collected at 0, 15 and 30 days of storage and analyzed by dilution plating and 16S rDNA PCR-DGGE analysis. There were significant differences in the total number of colony forming units(CFUs) of bacteria between heated and nonheated saps. Bacteria of nonheated sap were present at a level of $3.4{\times}10^7CFU/m{\ell}^{-1}$, whereas living bacteria were not detected in the heated sap. According to the 16S rDNA sequence and DGGE analysis, Pseudomonas sp. was the most abundant bacterial strain in the samlpes, and the bacterial community structures become more simplified with time and were composed of the Chryseobacterium sp. with time. These results allowed us to characterize the dominant bacteria involved in Gorosoe sap and to better understand their dynamics throughout storage.

Efficient Storage Management Scheme for Graph Historical Retrieval (그래프 이력 데이터 접근을 위한 효과적인 저장 관리 기법)

  • Kim, Gihoon;Kim, Ina;Choi, Dojin;Kim, Minsoo;Bok, Kyoungsoo;Yoo, Jaesoo
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.2
    • /
    • pp.438-449
    • /
    • 2018
  • Recently, various graph data have been utilized in various fields such as social networks and citation networks. As the graph changes dynamically over time, it is necessary to manage the graph historical data for tracking changes and retrieving point-in-time graphs. Most historical data changes partially according to time, so unchanged data is stored redundantly when data is stored in units of time. In this paper, we propose a graph history storage management method to minimize the redundant storage of time graphs. The proposed method continuously detects the change of the graph and stores the overlapping subgraph in intersection snapshot. Intersection snapshots are connected by a number of delta snapshots to maintain change data over time. It improves space efficiency by collectively managing overlapping data stored in intersection snapshots. We also linked intersection snapshots and delta snapshots to retrieval the graph at that point in time. Various performance evaluations are performed to show the superiority of the proposed scheme.

A Study on Production of Low Storage Capacity of Character Animation for 3D Mobile Games (3D 모바일 게임용 저용량 3D캐릭터 애니메이션 제작에 관한 연구)

  • Lee Ji-Won;Kim Tae-Yul;Kyung Byung-Pyo
    • The Journal of the Korea Contents Association
    • /
    • v.5 no.5
    • /
    • pp.107-114
    • /
    • 2005
  • The next generation of 3D mobile games market is becoming increasingly active, more as a result of improvement in the CPU speed of hardware phone, embarkation of 3D engines and high memory capacity, In response to this trend, popular 3D games of PS2 (PlayStation2) and popular online games are being launched as mobile games. However, mobile units have different hardware characteristics compared to those of other platforms such as the PC or the game console. Therefore, mobile game versions of the popular PC games face many limitations in many aspects such as in battery capacity, size of display, capacity of the game, and other user interface issues. Among these many limitations, study for allowing low capacity storage of the game is becoming important. In addition, realistic animation of the 3D character on the small screen of the mobile unit is more important than any other matter. The purpose of this study is to find a solution to providing realistic 3D character animation, and for decreasing the storage capacity of character animation for application in 3D mobile games.

  • PDF

Development of Guidelines for Indoor Environment in Apartment Remodeling Projects (아파트 리모델링의 실내환경 계획지침 개발)

  • Choi, Yoon-Jung
    • Journal of the Korean housing association
    • /
    • v.20 no.3
    • /
    • pp.1-10
    • /
    • 2009
  • The final aim of this study was to propose guidelines for the indoor environment of apartment remodeling projects. The first task of this study was to understand the major elements and the actual condition of the remodeling for apartment unit by carrying out in-depth interviews on residents and specialists. The open-access interviews were conducted with interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment units. The second task was to evaluate the actual condition of the indoor environment and to analyze the main factors that affect the indoor environment in remodeled apartment units. Field measurements were carried out in twenty apartment units occupied after remodeling, recording indoor environment elements (indoor temperature, globe temperature, relative humidity, $CO_2$, CO, PM10, TVOC, HCHO, illumination, and equivalent noise level). Moreover, resident interviews and researcher observations were carried out to determine the contents of the remodeled unit and to investigate the architectural and living factors(like ventilation characteristics, etc.) related to the indoor environment. The results are as follows. The remodeling elements generally included the changing of lighting fixtures and finishing materials in all the spaces, the integration of the balcony into the children's room, the installation of furniture in the kitchen and the entrance, the changing storage furnitures and equipments in the bathroom. The average levels of each unit of relative humidity, $CO_2$, TVOC, HCHO, equivalent noise level, and illumination were proved to be on the whole in inadequate condition. The factors that affect these indoor elements were classified as remodeling factors (remodeling amounts, extent balcony integration, and lighting fixture exchange), ventilation characteristics, and living factors. According to these results, this research proposed the guidelines for the indoor environment in apartment remodeling projects.

A Study of Efficient Floor Planning and Facility Improvement for Physical Therapy Room of Domestic Long-term Hospitals (국내 요양병원의 물리치료실의 효율적 평면계획 및 시설개선에 관한 연구)

  • Chung, Kwang-Ho
    • Journal of The Korean Digital Architecture Interior Association
    • /
    • v.11 no.4
    • /
    • pp.5-11
    • /
    • 2011
  • The present study investigated the actual conditions of physical therapy rooms at long-term hospitals in Korea and conducted a comparative analysis to develop an efficient floor plan and facility improvement measures. 1. At hospitals surveyed, physical therapy services were used at a high frequency but they did not have enough space for rehab treatment and long paths of patient flow were found to make patient management inconvenient. Therefore, physical therapy units should be conveniently located both in terms of distance and direction so as to be accessible from patient rooms or wards. The space should be organized in a concentrated layout for efficiency of physical therapy, and floor planning for therapy units should ensure the best possible viewing angle to therapists. 2. With regard to the disease characteristics of patients, many physical therapy rooms were in difficult circumstances because of poor facilities, so they need to secure skilled personnel, supplement apparatuses and equipment and have rooms for functional recovery, hydrotherapy and operation treatment. In addition, each of the curtained or partitioned areas for treatment should be set up with consideration for the amount of space taken up by medical equipment. The area under each bed should be designed for patient convenience so that it can be used as storage space for patient's belongings and shoes. 3. Patients complained about the lack of physical therapy space, resting places or exercise areas and demanded the expansion of rehab programs and facilities. Physical therapy facilities need to be improved for patient privacy and effective natural ventilation. 4. At most of the long-term hospitals surveyed, physical therapy units were found to have small areas and treatment equipment and devices were insufficient compared to the number of patients. Therefore, it is required to secure more space (at least 138.24 sq. meters per 100 beds) and improve facilities for better physical therapy services.

A Review of Renal Dialysis Unit Environment for Infection Prevention - Focused on Evidence Based Design (감염 예방을 위한 인공신장실 의료 환경에 대한 고찰 - 근거 기반의 디자인 중심으로)

  • Han, Su Ha;Yoon, Hyungjin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.24 no.3
    • /
    • pp.49-57
    • /
    • 2018
  • Purpose: The increase in patients requiring hemodialysis has resulted in an increase dialysis-associated infections risk. but there are no Renal Dialysis unit design standard meet specified safety and quality standards. Therefore, appropriate Establish standards and legal regulation is important for the provision of initial certification and maintenance of facility, equipment, and human resource quality. Methods: Literature survey on the design guideline and standards of Renal Dialysis unit design in Korea, U.S, Germany, Singapore, Hongkong, Dubai. Results: There are no established standards for facilities in dialysis units in Korea. To prevent infections in dialysis patients, necessary establish standards. Considering the domestic and overseas Health-care facilities standards, the major factors to be considered in the medical environment for Renal Dialysis Unit are as follows. First, planning to separate Clean areas(treatment area) from contaminated areas(medical waste storage area). Second, ensure sufficient space and minimum separation distance. Although there may be differences depending on the circumstances of individual institutions, renal dialysis unit consider the space to prevent droplet transmission. Third, secure infrastructure of infection prevention such as sufficient amount of hand hygiene sinks. Hand washing facilities for staff within the Unit should be readily available. Hand hygiene sinks should be located to prevent water from splashing into the treatment area. Fourth, Heating, ventilation and air conditioning (HVAC) system for Renal Dialysis Unit is all about providing a safer environment for patients and staff. Implications: The results of this paper can be the basic data for the design of the Renal Dialysis Units and relevant regulations.