• Title/Summary/Keyword: Storage Solution

Search Result 1,320, Processing Time 0.027 seconds

Fault Tree Analysis for Risk Assessment of CO2 Leakage from Geologic Storage (지중 저장 이산화탄소의 누출 위험도 평가를 위한 결함수 분석)

  • Lee, Sang Il;Lee, Sang Ki;Hwang, Jin Hwan
    • Journal of Environmental Impact Assessment
    • /
    • v.18 no.6
    • /
    • pp.359-366
    • /
    • 2009
  • CCS (Carbon Capture and Storage) is considered as the most promising interim solution to deal with the greenhouse gas such as $CO_2$ responsible for global warming. Even though carefully chosen geologic formations are known to contain stored gas for a long time period, there are potential risks of leakage. Up to now, applicable risk assessment procedures for the leakage of $CO_2$ are not available. This study presents a basis for risk analysis applicable to a complex geologic storage system. It starts with the classification of potential leakage pathways. Receptors and the leakage effect on them are identified and quantified. Then, a fault tree is constructed, which yields the minimum cut set (i.e., the most vulnerable leakage pathway) and quantifies the probability of the leakage risk through the cut set. The methodology will provide a tool for risk assessment in a CCS project. The outcomes of the assessment will not only ensure the safety of the CCS system but also offer a reliable and efficient monitoring plan.

Hazardous event analysis in drinking water production using aquifer storage transfer and recovery (대수층 저장·이동 및 회수에 의한 음용수 생산과정에서의 위해사건분석)

  • Lee, Sang-Il;Ji, Hyon-Wook
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.29 no.1
    • /
    • pp.23-31
    • /
    • 2015
  • Aquifer storage transfer and recovery (ASTR) is a type of managed aquifer recharge which entails injecting water into a storage well and recovering it from a different well. It has effects of natural purification when injected water passes through aquifer medium, and can be a good way of supplying water especially in a region with poor surface water quality. This study is about an on-going effort to introduce ASTR as a solution to source water problems in coastal areas. A pilot study is being conducted in the delta of the Nakdong River. A proactive management system is incorporated to ensure the water qulity in the process of drinking water process. The system is based on the Hazard Analysis and Critical Control Point (HACCP) which is a tool originated from the food industry in order to assess hazards and establish control systems for the safety of food product. In this paper, we analyze hazardous events which can occur in the entire water supply system using ASTR as a first step to the incorporation of HACCP to drinking water production process.

Effect of Aqueous Chlorine Dioxide Treatment on the Microbial Growth and Qualities of Strawberries During Storage

  • Jin, You-Young;Kim, Yun-Jung;Chung, Kyung-Sook;Won, Mi-Sun;Song, Kyung-Bin
    • Food Science and Biotechnology
    • /
    • v.16 no.6
    • /
    • pp.1018-1022
    • /
    • 2007
  • Effect of aqueous chlorine dioxide treatment on the microbial growth and quality changes of strawberries during storage was examined. Strawberries were treated with 5, 10, and 50 ppm of chlorine dioxide solution, and stored at $4{\pm}1^{\circ}C$. Total aerobic bacteria in strawberries treated at 50 ppm of chlorine dioxide were increased from 1.40 to 2.10 log CFU/g after 7 days, while increasing in the control from 2.75 to 4.32 log CFU/g. Yeasts and molds in strawberries treated at 50 ppm of chlorine dioxide were increased from 1.10 to 1.97 log CFU/g after 7 days, while the control was increased from 2.55 to 4.50 log CFU/g. The pH and titratable acidity of strawberries were not significantly different among treatments. Sensory evaluation results showed that chlorine dioxide-treated strawberries had better sensory scores than the control. These results indicate that chlorine dioxide treatment could be useful in improving the microbial safety and qualities of strawberries during storage.

Simulation of Interim Spent Fuel Storage System with Discrete Event Model (이산 모형을 이용한 사용후 핵연료 중간 저장 시설의 전산기 모사)

  • Yoon, Wan-Ki;Song, Ki-Chan;Lee, Jae-Sol;Park, Hyun-Soo
    • Nuclear Engineering and Technology
    • /
    • v.21 no.3
    • /
    • pp.223-230
    • /
    • 1989
  • This paper describes dynamic simulation of the spent fuel storage system which is described by statistical discrete event models. It visualizes flow and queue of system over time, assesses the operational performance of the system acitivies and establishes the system components and streams. It gives information on system organization and operation policy with reference to the design. System was tested and analyzed over a number of critical parameters to establish the optimal system. Workforce schedule and resources with long processing time dominate process. A combination of two workforce shifts a day and two cooling pits gives the optimal solution of storage system. Discrete system simulation is an useful tool to get information on optimal design and operation of the storage system.

  • PDF

Log Storage Scheme Considering Log Transmission Based on Time-Delayed Key Disclosure (키 지연 노출에 기반을 둔 로그 전송을 고려한 로그 저장 기법)

  • Kang, Seok-Gyu;Park, Chang-Seop
    • Convergence Security Journal
    • /
    • v.15 no.5
    • /
    • pp.37-45
    • /
    • 2015
  • In IT system, logs are an indicator of the previous key events. Therefore, when a security problem occurs in the system, logs are used to find evidence and solution to the problem. So, it is important to ensure the integrity of the stored logs. Existing schemes have been proposed to detect tampering of the stored logs after the key has been exp osed. Existing schemes are designed separately in terms of log transmission and storage. We propose a new log sys tem for integrating log transmission with storage. In addition, we prove the security requirements of the proposed sc heme and computational efficiency with existing schemes.

Feasibility study on realization of high resolution solid immersion lensbased near-field microscopy by use of an annular aperture (광학 필터를 사용한 고해상 고체침지 렌즈 기반 근접장 현미경 적용 가능성에 대한 연구)

  • Moon, H.B.;Yoon, Y.J.;Kim, T.S.;Park, Y.P.;Park, N.C.;Park, K.S.
    • Transactions of the Society of Information Storage Systems
    • /
    • v.6 no.2
    • /
    • pp.79-82
    • /
    • 2010
  • In optical imaging systems, such as microscopes, high resolution exposure systems, and optical storage devices, higher optical resolution is a requirement. One of the promising technologies that is able to satisfy this requirement with relatively simple construction and reliable performance are, solid immersion lens (SIL)-based near-field (NF) optical systems. High NA optical systems using annular apertures have been investigated as one solution to achieve higher resolutions and an extended focal depth. By applying an optimized annular aperture to convention SIL optical head resolution can be increased by approximately 20%. This novel SIL-based near-field optics will be verified through experiments such as measuring focused beam spot profiles and observing the topology of a measurement sample. The studied SIL-based near-field optics can be applicable to not only next generation optical storage device but also high resolution microscopy and pattering technologies.

Nonlinear responses of energy storage pile foundations with fiber reinforced concrete

  • Tulebekova, Saule;Zhang, Dichuan;Lee, Deuckhang;Kim, Jong R.;Barissov, Temirlan;Tsoy, Viktoriya
    • Structural Engineering and Mechanics
    • /
    • v.71 no.4
    • /
    • pp.363-375
    • /
    • 2019
  • A renewable energy storage pile foundation system is being developed through a multi-disciplinary research project. This system intends to use reinforced concrete pile foundations configured with hollowed sections to store renewable energy generated from solar panels attached to building structures in the form of compressed air. However previous research indicates that the compressed air will generate considerable high circumferential tensile stresses in the concrete pile, which requires unrealistic high hoop reinforcement ratio to avoid leakage of the compressed air. One possible solution is to utilize fiber reinforced concrete instead of placing the hoop reinforcement to resist the tensile stress. This paper investigates nonlinear structural responses and post-cracking behavior of the fiber reinforced concrete pile subjected to high air pressure through nonlinear finite element simulations. Concrete damage plasticity models were used in the simulation. Several parameters were considered in the study including concrete grade, fiber content, and thickness of the pile section. The air pressures which the pile can resist at different crack depths along the pile section were identified. Design recommendations were provided for the energy storage pile foundation using the fiber reinforced concrete.

Performance Analysis on a Heat Pump System using Waste Heat (폐열이용 열펌프시스템의 성능에 관한 연구)

  • Park, Youn Cheol;Song, Lei;Ko, Gwang Soo
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.53-60
    • /
    • 2018
  • This study was conducted for analysis of a heat pump system using waste heat in an enclosed space such as a green house. The model was developed with mathematical equations in literature and Engineering Equation Solver (EES) was used to get the solution of the developed equations. The simulation results have 5% of reliability comparing the results with actual test data of heat pump system's dynamic operation. The operating performance of the system was calculated with variation of working fluid temperature in the thermal storage tank such as $25^{\circ}C$, $35^{\circ}C$, $45^{\circ}C$ and $55^{\circ}C$. As a result, the system's the highest total heating capacity shows 280 kWh and the storage tank's operating time decreased as the starting storage tank's temperature was high.

Effect of chitosan coating combined with hypotaurine on the quality of shrimp (Litopenaeus vannamei) during storage

  • Chen, Meiyu;Hu, Lingping;Hu, Zhiheng;Zhou, Yaqi;Li, Gaoshang;Chin, Yaoxian;Hu, Yaqin
    • Fisheries and Aquatic Sciences
    • /
    • v.25 no.2
    • /
    • pp.64-75
    • /
    • 2022
  • This study aimed to investigate the effect of different coating materials on the quality of shrimp (Litopenaeus vannamei) during chilled storage for 10 days. Fresh shrimp were randomly divided into five groups: the control group, the hypotaurine treatment group (2%), the chitosan group (1%), the hypotaurine + chitosan group (2% hypotaurine solution with 1% of chitosan), and the sodium metabisulfite treatment group (1.25%). Compared with other treatments, the lower accumulation of total visible counts (TVC, 5.25 Log10 CFU/g), total volatile basic nitrogen (TVB-N, 22.5 mg/100 g) and thiobarbituric acid values (TBA, 0.58 mg MDA/kg) suggested that coating of chitosan-hypotaurine could retard the microbial activity, protein degradation and lipid oxidation of shrimp. Meanwhile, results demonstrated that the chitosan coating combined with hypotaurine showed an excellent performance in inhibiting quality deterioration (pH 7.5, ∆E 7.0, hardness 393 g, and elasticity 0.69). Furthermore, the melanosis degree of shrimp was alleviated, and the sensory parameters, including appearance, odor and texture, were maintained to the acceptable level by chitosan based hypotaurine treatment during the chilled storage.

Portable Energy Storage System for DC House and Emergency Response in Indonesia

  • Hudaya, Chairul;Aryani, Dwi Riana;Heatubun, Yosca Rose Anggita;Taufiqurahman, Wahyu;Verdianto, Ariono;Garniwa, Iwa;Sung, Yung-Eun
    • Journal of Appropriate Technology
    • /
    • v.5 no.1
    • /
    • pp.33-37
    • /
    • 2019
  • One of main problems in developing electricity grid for archipelago country like Indonesia is the geographical concerns as it consists of many islands. In some rural areas, electricity has not been available yet due to the limited infrastructure access, leading to high investment cost. In this study, a portable energy storage system based on the lithium-ion batteries called Tabung Listrik or TaLis (DC-based power bank) and DC house system were proposed as the solution for providing electricity for rural areas with relatively lower cost. TaLis is designed to be portable so it is easy to carry around as well as it can be used for many purposes. Since 2017, TaLis prototype has been used as the energy storage in a DC house system at Sekolah Master Indonesia, where an array of PV rooftop is functioned as the main DC power supply. Besides, some TaLis were also dispatched for emergency response during the disaster situations in Indonesia, such as during the measles outbreak in Asmat-Papua, the earthquake disaster in Lombok and tsunami in Palu.